David L. Alexoff
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
David L. Alexoff has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Joanna S. Fowler
Brookhaven National Laboratory
6 shared publications - Benjamin A. Babst
Biosciences Department, Brookhaven National Laboratory, Upton, NY 11973-5000, USA
3 shared publications - Dohyun Kim
Brookhaven Natl Lab, Isotope Res & Prod Dept, Upton, NY USA
3 shared publications - Michael J. Schueller
Biological, Environmental, and Climate Sciences Department, Brookhaven National Laboratory, Upton, NY, 11973, USA.
3 shared publications - Nora D. Volkow
National Institute on Alcohol Abuse and Alcoholism, National Institutes of Health, Bethesda, USA
3 shared publications Chandra S. Chaurasia
College of Pharmacy and Allied Health Professions, St. Johns University, Queens, New York
2 shared publications
Latest Publications
- Open Access
- 9 November 2015
- Published by Springer Nature in BMC Plant Biology
- Vol. 15 (1) , 1-11
In vivo quantitative imaging of photoassimilate transport dynamics and allocation in large plants using a commercial positron emission tomography (PET) scanner
Although important aspects of whole-plant carbon allocation in crop plants (e.g., to grain) occur late in development when the plants are large, techniques to study carbon transport and allocation processes have not been adapted for large plants. Positron emission tomography (PET), developed for dynamic imaging in medicine, has been applied in plant studies to measure the transport and allocation patterns of carbohydrates, nutrients, and phytohormones labeled with positron-emitting radioisotopes. However, the cost of PET and its limitation to smaller plants has restricted its use in plant biology. Here we describe the adaptation and optimization of a commercial clinical PET scanner to measure transport dynamics and allocation patterns of 11C-photoassimilates in large crops. Based on measurements of a phantom, we optimized instrument settings, including use of 3-D mode and attenuation correction to maximize the accuracy of measurements. To demonstrate the utility of PET, we measured 11C-photoassimilate transport and allocation in Sorghum bicolor, an important staple crop, at vegetative and reproductive stages (40 and 70 days after planting; DAP). The 11C-photoassimilate transport speed did not change over the two developmental stages. However, within a stem, transport speeds were reduced across nodes, likely due to higher 11C-photoassimilate unloading in the nodes. Photosynthesis in leaves and the amount of 11C that was exported to the rest of the plant decreased as plants matured. In young plants, exported 11C was allocated mostly (88 %) to the roots and stem, but in flowering plants (70 DAP) the majority of the exported 11C (64 %) was allocated to the apex. Our results show that commercial PET scanners can be used reliably to measure whole-plant C-allocation in large plants nondestructively including, importantly, allocation to roots in soil. This capability revealed extreme changes in carbon allocation in sorghum plants, as they advanced to maturity. Further, our results suggest that nodes may be important control points for photoassimilate distribution in crops of the family Poaceae. Quantifying real-time carbon allocation and photoassimilate transport dynamics, as demonstrated here, will be important for functional genomic studies to unravel the mechanisms controlling phloem transport in large crop plants, which will provide crucial insights for improving yields.
- 9 November 2015
- Published by Springer Nature in BMC Plant Biology
- Vol. 15 (1) , 1-11
Open AccessIn vivo quantitative imaging of photoassimilate transport dynamics and allocation in large plants using a commercial positron emission tomography (PET) scanner
Although important aspects of whole-plant carbon allocation in crop plants (e.g., to grain) occur late in development when the plants are large, techniques to study carbon transport and allocation processes have not been adapted for large plants. Positron emission tomography (PET), developed for dynamic imaging in medicine, has been applied in plant studies to measure the transport and allocation patterns of carbohydrates, nutrients, and phytohormones labeled with positron-emitting radioisotopes. However, the cost of PET and its limitation to smaller plants has restricted its use in plant biology. Here we describe the adaptation and optimization of a commercial clinical PET scanner to measure transport dynamics and allocation patterns of 11C-photoassimilates in large crops. Based on measurements of a phantom, we optimized instrument settings, including use of 3-D mode and attenuation correction to maximize the accuracy of measurements. To demonstrate the utility of PET, we measured 11C-photoassimilate transport and allocation in Sorghum bicolor, an important staple crop, at vegetative and reproductive stages (40 and 70 days after planting; DAP). The 11C-photoassimilate transport speed did not change over the two developmental stages. However, within a stem, transport speeds were reduced across nodes, likely due to higher 11C-photoassimilate unloading in the nodes. Photosynthesis in leaves and the amount of 11C that was exported to the rest of the plant decreased as plants matured. In young plants, exported 11C was allocated mostly (88 %) to the roots and stem, but in flowering plants (70 DAP) the majority of the exported 11C (64 %) was allocated to the apex. Our results show that commercial PET scanners can be used reliably to measure whole-plant C-allocation in large plants nondestructively including, importantly, allocation to roots in soil. This capability revealed extreme changes in carbon allocation in sorghum plants, as they advanced to maturity. Further, our results suggest that nodes may be important control points for photoassimilate distribution in crops of the family Poaceae. Quantifying real-time carbon allocation and photoassimilate transport dynamics, as demonstrated here, will be important for functional genomic studies to unravel the mechanisms controlling phloem transport in large crop plants, which will provide crucial insights for improving yields.
- 1 August 2015
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 102, 48-54
Total cyanide mass measurement with micro-ion selective electrode for determination of specific activity of carbon-11 cyanide
- 1 August 2015
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 102, 48-54
Total cyanide mass measurement with micro-ion selective electrode for determination of specific activity of carbon-11 cyanide
- 1 December 2014
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 94, 338-343
The design and performance of a portable handheld 11CO2 delivery system
- 1 December 2014
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 94, 338-343
The design and performance of a portable handheld 11CO2 delivery system
- 1 September 2014
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 91, 155-160
Radiosynthesis of 3-indolyl[1-11C]acetic acid for phyto-PET-imaging: An improved production procedure and formulation method
- 1 September 2014
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 91, 155-160
Radiosynthesis of 3-indolyl[1-11C]acetic acid for phyto-PET-imaging: An improved production procedure and formulation method
- 28 October 2010
- Published by Elsevier in Nuclear Medicine and Biology
- Vol. 38 (2) , 191-200
PET imaging of thin objects: measuring the effects of positron range and partial-volume averaging in the leaf of Nicotiana tabacum
- 28 October 2010
- Published by Elsevier in Nuclear Medicine and Biology
- Vol. 38 (2) , 191-200
PET imaging of thin objects: measuring the effects of positron range and partial-volume averaging in the leaf of Nicotiana tabacum
- 1 May 2003
- Vol. 44 (5) , 815-22
Reproducibility of 11C-raclopride binding in the rat brain measured with the microPET R4: effects of scatter correction and tracer specific activity.
A new generation of commercial animal PET cameras may accelerate drug development by streamlining preclinical testing in laboratory animals. However, little information on the feasibility of using these machines for quantitative PET in small animals is available. Here we investigate the reproducibility of microPET imaging of (11)C-raclopride in the rat brain and the effects of tracer-specific activity and photon scatter correction on measures of D2 receptor (D2R) availability. Sprague-Dawley rats (422 +/- 29 g; n = 7) were anesthetized with ketamine/xylazine and catheterized for tail vein injection of (11)C-raclopride. Each animal was positioned prone in the microPET, centering the head in the field of view. MicroPET data was collected for 60 min-starting at (11)C-raclopride injection-and binned into 24 time frames (6 x 10 s, 3 x 20 s, 8 x 60 s, 4 x 200 s, 3 x 600 s). In 3 studies, (11)C-raclopride was administered a second time in the same animal, with 2-4 h between injections. In a fourth animal, raclopride (1 mg/kg) was coinjected with (11)C-raclopride for the second injection. Three rats received a single dose of (11)C-raclopride. The range of doses for all studies was 6.11-18.54 MBq (165-501 micro Ci). The specific activity at injection was 4.07-48.1 GBq/ micro mol (0.11-1.3 Ci/ micro mol). Region-of-interest analysis was performed and the distribution volume ratio (DVR) was computed for striatum/cerebellum using sinograms uncorrected and corrected for scatter using a tail-fit method. Test-retest results showed that the (11)C-raclopride microPET DVR was reproducible (change in DVR = -8.3% +/- 4.4%). The average DVR from 6 rats injected with high specific activity (1.5 nmol/kg. Scatter fractions within the rat head were approximately 25%-45% resulting in an average increase of DVR of 3.5% (range, 0%-10%) after correction. This study shows that the (11)C-raclopride microPET-derived DVR is reproducible and suitable for studying D2R availability in the rat brain. MicroPET sensitivity was sufficient to determine reproducible DVRs from (11)C-raclopride injections of 9.25 MBq (approximately 250 micro Ci). However, the effect of tracer mass on the DVR should be considered for studies using more than approximately 1-2 nmol/kg raclopride, and scatter correction has a measurable impact on the results.
- 1 May 2003
- Vol. 44 (5) , 815-22
Reproducibility of 11C-raclopride binding in the rat brain measured with the microPET R4: effects of scatter correction and tracer specific activity.
A new generation of commercial animal PET cameras may accelerate drug development by streamlining preclinical testing in laboratory animals. However, little information on the feasibility of using these machines for quantitative PET in small animals is available. Here we investigate the reproducibility of microPET imaging of (11)C-raclopride in the rat brain and the effects of tracer-specific activity and photon scatter correction on measures of D2 receptor (D2R) availability. Sprague-Dawley rats (422 +/- 29 g; n = 7) were anesthetized with ketamine/xylazine and catheterized for tail vein injection of (11)C-raclopride. Each animal was positioned prone in the microPET, centering the head in the field of view. MicroPET data was collected for 60 min-starting at (11)C-raclopride injection-and binned into 24 time frames (6 x 10 s, 3 x 20 s, 8 x 60 s, 4 x 200 s, 3 x 600 s). In 3 studies, (11)C-raclopride was administered a second time in the same animal, with 2-4 h between injections. In a fourth animal, raclopride (1 mg/kg) was coinjected with (11)C-raclopride for the second injection. Three rats received a single dose of (11)C-raclopride. The range of doses for all studies was 6.11-18.54 MBq (165-501 micro Ci). The specific activity at injection was 4.07-48.1 GBq/ micro mol (0.11-1.3 Ci/ micro mol). Region-of-interest analysis was performed and the distribution volume ratio (DVR) was computed for striatum/cerebellum using sinograms uncorrected and corrected for scatter using a tail-fit method. Test-retest results showed that the (11)C-raclopride microPET DVR was reproducible (change in DVR = -8.3% +/- 4.4%). The average DVR from 6 rats injected with high specific activity (1.5 nmol/kg. Scatter fractions within the rat head were approximately 25%-45% resulting in an average increase of DVR of 3.5% (range, 0%-10%) after correction. This study shows that the (11)C-raclopride microPET-derived DVR is reproducible and suitable for studying D2R availability in the rat brain. MicroPET sensitivity was sufficient to determine reproducible DVRs from (11)C-raclopride injections of 9.25 MBq (approximately 250 micro Ci). However, the effect of tracer mass on the DVR should be considered for studies using more than approximately 1-2 nmol/kg raclopride, and scatter correction has a measurable impact on the results.