Thomas E. Bernard
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Thomas E. Bernard has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Candi D. Ashley
University of South Florida, College of Education , Tampa, Florida
3 shared publicationsVictor Caravello
University of South Florida, Tampa, FL
2 shared publicationsChristina L. Luecke
University of South Florida, College of Public Health , Tampa, Florida
1 shared publicationDonald W. Barker
Florida Power Corp., Crystal River, USA
1 shared publicationK. Scott Kirkland
Progress Energy Florida, Crystal River Nuclear Generation , Crystal River, Florida
1 shared publicationPerry W. Logan
College of Public Health, University of South Florida, Tampa 33612-3805, USA
1 shared publication
Latest Publications
- 1 May 2005
- Published by Taylor & Francis in Journal of Occupational and Environmental Hygiene
- Vol. 2 (5) , 251-256
WBGT Clothing Adjustments for Four Clothing Ensembles Under Three Relative Humidity Levels
Threshold limit values for heat stress and strain are based on an upper limit wet bulb globe temperature (WBGT) for ordinary work clothes, with clothing adjustment factors (CAF) for other clothing ensembles. The purpose of this study was to determine the CAF for four clothing ensembles (Cotton Coveralls, Tyvek® 1424 Coveralls, NexGen® Coveralls, and Tychem QC® Coveralls) against a baseline of cotton work clothes and to determine what effect relative humidity may have. A climatic chamber was used to slowly increase the level of heat stress by increasing air temperature at three levels of relative humidity (20%, 50%, and 70%). Study participants wore one of the five ensembles while walking on a treadmill at a moderate metabolic rate of 155 W m-2 (about 300 W). Physiological data and environmental data were collected. When the participant's core temperature reached a steady state, the dry bulb temperature was increased at constant relative humidity. The point at which the core temperature began to increase was defined as the inflection point. The environmental temperature recorded 5 min before the inflection point was used to calculate the critical WBGT for each ensemble. A three−way analysis of variance with ensemble by humidity protocol interactions and a multiple comparison test were used to make comparisons among the mean values. Only the vapor−barrier ensemble (Tychem QC) demonstrated an interaction with humidity level. The following CAFs are proposed: Cotton Coveralls (0°C–WBGT), Tyvek 1424 Coveralls (+1), NexGen Coveralls (+2), and Tychem QC Coveralls (+10).
- 1 May 2005
- Published by Taylor & Francis in Journal of Occupational and Environmental Hygiene
- Vol. 2 (5) , 251-256
WBGT Clothing Adjustments for Four Clothing Ensembles Under Three Relative Humidity Levels
Threshold limit values for heat stress and strain are based on an upper limit wet bulb globe temperature (WBGT) for ordinary work clothes, with clothing adjustment factors (CAF) for other clothing ensembles. The purpose of this study was to determine the CAF for four clothing ensembles (Cotton Coveralls, Tyvek® 1424 Coveralls, NexGen® Coveralls, and Tychem QC® Coveralls) against a baseline of cotton work clothes and to determine what effect relative humidity may have. A climatic chamber was used to slowly increase the level of heat stress by increasing air temperature at three levels of relative humidity (20%, 50%, and 70%). Study participants wore one of the five ensembles while walking on a treadmill at a moderate metabolic rate of 155 W m-2 (about 300 W). Physiological data and environmental data were collected. When the participant's core temperature reached a steady state, the dry bulb temperature was increased at constant relative humidity. The point at which the core temperature began to increase was defined as the inflection point. The environmental temperature recorded 5 min before the inflection point was used to calculate the critical WBGT for each ensemble. A three−way analysis of variance with ensemble by humidity protocol interactions and a multiple comparison test were used to make comparisons among the mean values. Only the vapor−barrier ensemble (Tychem QC) demonstrated an interaction with humidity level. The following CAFs are proposed: Cotton Coveralls (0°C–WBGT), Tyvek 1424 Coveralls (+1), NexGen Coveralls (+2), and Tychem QC Coveralls (+10).
- 1 May 2004
- Published by Wolters Kluwer Health in Medicine & Science in Sports & Exercise
- Vol. 36 (Supplement) , S316
Predicting Compensable versus Uncompensable Heat Stress from Physiological Strain Index
- 1 May 2004
- Published by Wolters Kluwer Health in Medicine & Science in Sports & Exercise
- Vol. 36 (Supplement) , S316
Predicting Compensable versus Uncompensable Heat Stress from Physiological Strain Index
- 1 May 2004
- Published by Wolters Kluwer Health in Medicine & Science in Sports & Exercise
- Vol. 36 (Supplement) , S316
Predicting Compensable versus Uncompensable Heat Stress from Physiological Strain Index
- 1 May 2004
- Published by Wolters Kluwer Health in Medicine & Science in Sports & Exercise
- Vol. 36 (Supplement) , S316
Predicting Compensable versus Uncompensable Heat Stress from Physiological Strain Index
- 1 September 1999
- Published by Taylor & Francis in AIHA Journal
- Vol. 60 (5) , 659-665
Heat Stress and Strain in an Aluminum Smelter
Studies of worker heat stress and strain in aluminum smelters have found that heat exposure likely to exceed the American Conference of Governmental Industrial Hygienists' threshold limit value (TLV®) and that the dose-response relationship between heat stress and strain was weak. A heat stress model based on climatic data and a task analysis indicated exposures to heat stress in excess of the TLV during the July/August study period. To study the impact of working above the TLV, heat strain data (i.e., oral temperature, recovery heart rate, average heart rate) were collected. Recovery heart rates indicated high strain most of the time, and oral temperatures after peak demands were above the no-strain threshold of 37.5°C about a quarter of the time, indicating that heat stress had an effect. About 95% of the readings were below 38.0°C, the acute oral temperature threshold for a safe exposure. Average heart rates over 6- and 12-hour intervals were generally below acceptable limits of 120 and 110 bpm, respectively. Oral temperature and average heart rates indicated good control of heat stress exposures. Because recovery heart rates were high, some employees were working near their individual limits. The dose-response relationship for recovery heart rate and oral temperature were examined against the level of heat stress above the TLV. There was no relationship between oral temperature and heat stress level. There was an apparent trend toward higher recovery heart rates with heat stress. The lack of a dose-response relationship may be explained by brief periods of very high wet bulb globe temperatures that drove the time-weighted average up out of proportion to the physiological response.
- 1 September 1999
- Published by Taylor & Francis in AIHA Journal
- Vol. 60 (5) , 659-665
Heat Stress and Strain in an Aluminum Smelter
Studies of worker heat stress and strain in aluminum smelters have found that heat exposure likely to exceed the American Conference of Governmental Industrial Hygienists' threshold limit value (TLV®) and that the dose-response relationship between heat stress and strain was weak. A heat stress model based on climatic data and a task analysis indicated exposures to heat stress in excess of the TLV during the July/August study period. To study the impact of working above the TLV, heat strain data (i.e., oral temperature, recovery heart rate, average heart rate) were collected. Recovery heart rates indicated high strain most of the time, and oral temperatures after peak demands were above the no-strain threshold of 37.5°C about a quarter of the time, indicating that heat stress had an effect. About 95% of the readings were below 38.0°C, the acute oral temperature threshold for a safe exposure. Average heart rates over 6- and 12-hour intervals were generally below acceptable limits of 120 and 110 bpm, respectively. Oral temperature and average heart rates indicated good control of heat stress exposures. Because recovery heart rates were high, some employees were working near their individual limits. The dose-response relationship for recovery heart rate and oral temperature were examined against the level of heat stress above the TLV. There was no relationship between oral temperature and heat stress level. There was an apparent trend toward higher recovery heart rates with heat stress. The lack of a dose-response relationship may be explained by brief periods of very high wet bulb globe temperatures that drove the time-weighted average up out of proportion to the physiological response.
- 1 January 1999
- Published by Taylor & Francis in AIHA Journal
- Vol. 60 (1) , 32-37
Thermal Characteristics of Clothing Ensembles for Use in Heat Stress Analysis
The Heat Stress Index was an early model for the assessment of heat stress. The International Organization for Standardization (ISO) standard for required sweat rate is the current generation of heat balance methods for occupational heat stress. The method assumes cotton clothing and works adequately for cotton/polyester blends. To extend the usefulness of the model, the thermal characteristics of a variety of commercially available and prototype protective clothing ensembles have been determined for application in the ISO method. The fundamental principle for assessing thermal characteristics of work clothing is establishing the critical environmental conditions in which test subjects were just able to maintain thermal equilibrium. Critical conditions were found for warm, humid conditions; hot, dry conditions; intermediate conditions of temperature and humidity; and/or moderate conditions in which metabolic rate was increased to a limiting thermal load. Typically, five subjects at each condition for each ensemble were used. Metabolic rate, average skin temperature, and the environmental conditions (air temperature and vapor pressure) were noted at the critical conditions, and the total insulation was estimated for each ensemble. From these values, the total evaporative resistance, the clothing factor for dry heat exchange (CFcl), and the clothing factor for evaporative cooling (CFpcl) were determined. When compared with reports of others on thermal characteristics the results agreed when pumping factors and clothing wetness were considered. The result was higher than expected values for CFcl and lower values for CFpcl.
- 1 January 1999
- Published by Taylor & Francis in AIHA Journal
- Vol. 60 (1) , 32-37
Thermal Characteristics of Clothing Ensembles for Use in Heat Stress Analysis
The Heat Stress Index was an early model for the assessment of heat stress. The International Organization for Standardization (ISO) standard for required sweat rate is the current generation of heat balance methods for occupational heat stress. The method assumes cotton clothing and works adequately for cotton/polyester blends. To extend the usefulness of the model, the thermal characteristics of a variety of commercially available and prototype protective clothing ensembles have been determined for application in the ISO method. The fundamental principle for assessing thermal characteristics of work clothing is establishing the critical environmental conditions in which test subjects were just able to maintain thermal equilibrium. Critical conditions were found for warm, humid conditions; hot, dry conditions; intermediate conditions of temperature and humidity; and/or moderate conditions in which metabolic rate was increased to a limiting thermal load. Typically, five subjects at each condition for each ensemble were used. Metabolic rate, average skin temperature, and the environmental conditions (air temperature and vapor pressure) were noted at the critical conditions, and the total insulation was estimated for each ensemble. From these values, the total evaporative resistance, the clothing factor for dry heat exchange (CFcl), and the clothing factor for evaporative cooling (CFpcl) were determined. When compared with reports of others on thermal characteristics the results agreed when pumping factors and clothing wetness were considered. The result was higher than expected values for CFcl and lower values for CFpcl.