Ozhan M. Turan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ozhan M. Turan has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Chris Harman
4 shared publicationsSifa Turan
Department of Obstetrics, Gynecology, and Reproductive Sciences, University of Maryland School of Medicine, 6th Floor, Room 6NE11, 22 South Greene Street, Baltimore, MD, 21201
4 shared publicationsCatalin S. Buhimschi
Department of Obstetrics, Gynecology, and Reproductive Sciences, Yale University School of Medicine, New Haven, Connecticut
3 shared publicationsEdmund F. Funai
Department of Obstetrics, Gynecology, and Reproductive Sciences, Yale University School of Medicine, New Haven, Connecticut
3 shared publications- Irina Alexandra Buhimschi
Department of Obstetrics and Gynecology, University of Illinois Chicago, Chicago, IL, 60612, USA
3 shared publications Joshua A. Copel
Department of Obstetrics, Gynecology, and Reproductive Sciences, Yale University School of Medicine, New Haven, Connecticut
3 shared publications
Latest Publications
- 1 January 2017
- Published by Elsevier in American Journal of Obstetrics and Gynecology
- Vol. 216 (1) , S286-S287
485: Increased fetal epicardial fat deposition: a new sign of altered fetal metabolism
- 1 January 2017
- Published by Elsevier in American Journal of Obstetrics and Gynecology
- Vol. 216 (1) , S286-S287
485: Increased fetal epicardial fat deposition: a new sign of altered fetal metabolism
- 1 January 2017
- Published by Elsevier in American Journal of Obstetrics and Gynecology
- Vol. 216 (1) , S287
486: Fetal epicardial fat thickness: a new tool for assessment of maternal glucose control
- 1 January 2017
- Published by Elsevier in American Journal of Obstetrics and Gynecology
- Vol. 216 (1) , S287
486: Fetal epicardial fat thickness: a new tool for assessment of maternal glucose control
- 1 January 2017
- Published by Elsevier in American Journal of Obstetrics and Gynecology
- Vol. 216 (1) , S303
513: Predicting neonatal hypoglycemia in women with altered glucose metabolism with ultrasound markers
- 1 January 2017
- Published by Elsevier in American Journal of Obstetrics and Gynecology
- Vol. 216 (1) , S303
513: Predicting neonatal hypoglycemia in women with altered glucose metabolism with ultrasound markers
- 13 September 2016
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 45 (2) , 96-104
Longitudinal analysis of head and somatic growth in fetuses with congenital heart defects
Purpose: Fetal head and somatic growth dynamics differs in fetuses with congenital heart defects (CHD). We longitudinally characterized fetal head and somatic growth in relation to the type of CHD.Methods: Four hundred eleven exams from isolated CHD were compared with 1,219 controls. Head and somatic growth was assessed using head circumference (HC), brain volume (BrV = 1/6 × π × (HC/π)3)/2), fetal cephalization index (FCI = BrV/[estimated fetal weight]), and growth percentile. Umbilical and middle cerebral artery Doppler indices were obtained. CHD were grouped as: (1) d‐transposition of great arteries (n = 11); (2) left ventricular outflow tract obstruction with retrograde isthmic flow (n = 18); (3) left ventricular outflow tract obstruction with antegrade isthmic flow (n = 16); (4) pulmonary outflow tract obstructions (n = 22).Results: The smallest head size was seen in group 1. Growth asymmetry was diagnosed in group 2. Brain sparing was seen in groups 2 and 4 (p < 0.0001). HC and BrV percentiles decreased with advancing gestational age (p < 0.001) in group 2, and a significant drop was observed around 28 weeks.Conclusions: d‐Transposition of great arteries and left‐sided CHD leading to isthmic blood flow reversal are associated with delayed head growth. Prenatal evaluation of central hemodynamics in CHD may be contributive for predicting neurodevelopmental risks in CHD and help directing prenatal interventions. © 2016 Wiley Periodicals, Inc. J Clin Ultrasound 45:96–104, 2017;
- 13 September 2016
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 45 (2) , 96-104
Longitudinal analysis of head and somatic growth in fetuses with congenital heart defects
Purpose: Fetal head and somatic growth dynamics differs in fetuses with congenital heart defects (CHD). We longitudinally characterized fetal head and somatic growth in relation to the type of CHD.Methods: Four hundred eleven exams from isolated CHD were compared with 1,219 controls. Head and somatic growth was assessed using head circumference (HC), brain volume (BrV = 1/6 × π × (HC/π)3)/2), fetal cephalization index (FCI = BrV/[estimated fetal weight]), and growth percentile. Umbilical and middle cerebral artery Doppler indices were obtained. CHD were grouped as: (1) d‐transposition of great arteries (n = 11); (2) left ventricular outflow tract obstruction with retrograde isthmic flow (n = 18); (3) left ventricular outflow tract obstruction with antegrade isthmic flow (n = 16); (4) pulmonary outflow tract obstructions (n = 22).Results: The smallest head size was seen in group 1. Growth asymmetry was diagnosed in group 2. Brain sparing was seen in groups 2 and 4 (p < 0.0001). HC and BrV percentiles decreased with advancing gestational age (p < 0.001) in group 2, and a significant drop was observed around 28 weeks.Conclusions: d‐Transposition of great arteries and left‐sided CHD leading to isthmic blood flow reversal are associated with delayed head growth. Prenatal evaluation of central hemodynamics in CHD may be contributive for predicting neurodevelopmental risks in CHD and help directing prenatal interventions. © 2016 Wiley Periodicals, Inc. J Clin Ultrasound 45:96–104, 2017;
- Open Access
- 1 March 2014
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 44 (5) , 562-567
First‐trimester fetal cardiac examination using spatiotemporal image correlation, tomographic ultrasound and color Doppler imaging for the diagnosis of complex congenital heart disease in high‐risk patients
Objective: A four‐dimensional (4D) fetal echocardiographic technique utilizing spatiotemporal image correlation, tomographic ultrasound imaging display (STIC‐TUI echo) and color Doppler has previously been shown to be effective in displaying the examination planes constituting the extended cardiac examination. The aim of this study was to evaluate the performance of this first‐trimester STIC‐TUI echo technique in identifying complex congenital heart disease (CHD) in high‐risk pregnancies.Methods: This was a prospective study of patients presenting at first‐trimester screening who were at high risk for CHD owing to pregestational diabetes, in‐vitro fertilization (IVF), increased nuchal translucency (NT) thickness, first‐trimester tricuspid regurgitation or reversed ductus venosus (DV) a‐wave, a previous child with CHD or who were on anticonvulsant medication. First‐trimester STIC‐TUI echo was performed, and the findings were correlated with second‐trimester echocardiography and post‐delivery echo findings in survivors.Results: One hundred and sixty‐four fetuses from 152 patients were enrolled (77 diabetics, 38 IVF, 14 with increased NT, 23 cases of tricuspid regurgitation or reversed a‐wave in the DV, 22 with prior CHD and two on anticonvulsants). STIC‐TUI echo was abnormal in 20 (12%), showing atrioventricular canal defect (n = 9), hypoplastic left heart (n = 2), pulmonary stenosis (n = 2), right aortic arch (n = 1), interrupted aortic arch (n = 1), tricuspid atresia (n = 1), heterotaxy (n = 1), persistent truncus arteriosus (n = 1), double outlet right ventricle and ventricular septal defect (n = 1) and double inlet ventricle with transposition of the great arteries (n = 1). 85% of these anomalies were evident in the four‐chamber view plane of the TUI display, and the remainder were diagnosed in the outflow tract planes with color Doppler imaging. In 13, CHD was isolated while seven had extracardiac anomalies. Thirteen fetuses had aneuploidy and all 13 underwent first‐trimester termination of pregnancy. In the remaining seven, second‐trimester echocardiography and neonatal echo/postmortem examination confirmed anomalies (two stillborn neonates, one neonatal death, four live births). Two cases of CHD missed by first‐trimester STIC‐TUI echo were diagnosed on second‐trimester echo. Accordingly, first‐trimester STIC‐TUI echo had 91% sensitivity and 100% specificity for the detection of CHD.Conclusions: First‐trimester 4D echocardiography using a standardized application of STIC, TUI and color Doppler imaging is effective in displaying the imaging planes that are necessary for achieving the diagnosis of complex cardiac anomalies in high‐risk patients. Optimal imaging of the four‐chamber view with two‐dimensional ultrasound is the major determinant of successful volume acquisition. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.
- 1 March 2014
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 44 (5) , 562-567
Open AccessFirst‐trimester fetal cardiac examination using spatiotemporal image correlation, tomographic ultrasound and color Doppler imaging for the diagnosis of complex congenital heart disease in high‐risk patients
Objective: A four‐dimensional (4D) fetal echocardiographic technique utilizing spatiotemporal image correlation, tomographic ultrasound imaging display (STIC‐TUI echo) and color Doppler has previously been shown to be effective in displaying the examination planes constituting the extended cardiac examination. The aim of this study was to evaluate the performance of this first‐trimester STIC‐TUI echo technique in identifying complex congenital heart disease (CHD) in high‐risk pregnancies.Methods: This was a prospective study of patients presenting at first‐trimester screening who were at high risk for CHD owing to pregestational diabetes, in‐vitro fertilization (IVF), increased nuchal translucency (NT) thickness, first‐trimester tricuspid regurgitation or reversed ductus venosus (DV) a‐wave, a previous child with CHD or who were on anticonvulsant medication. First‐trimester STIC‐TUI echo was performed, and the findings were correlated with second‐trimester echocardiography and post‐delivery echo findings in survivors.Results: One hundred and sixty‐four fetuses from 152 patients were enrolled (77 diabetics, 38 IVF, 14 with increased NT, 23 cases of tricuspid regurgitation or reversed a‐wave in the DV, 22 with prior CHD and two on anticonvulsants). STIC‐TUI echo was abnormal in 20 (12%), showing atrioventricular canal defect (n = 9), hypoplastic left heart (n = 2), pulmonary stenosis (n = 2), right aortic arch (n = 1), interrupted aortic arch (n = 1), tricuspid atresia (n = 1), heterotaxy (n = 1), persistent truncus arteriosus (n = 1), double outlet right ventricle and ventricular septal defect (n = 1) and double inlet ventricle with transposition of the great arteries (n = 1). 85% of these anomalies were evident in the four‐chamber view plane of the TUI display, and the remainder were diagnosed in the outflow tract planes with color Doppler imaging. In 13, CHD was isolated while seven had extracardiac anomalies. Thirteen fetuses had aneuploidy and all 13 underwent first‐trimester termination of pregnancy. In the remaining seven, second‐trimester echocardiography and neonatal echo/postmortem examination confirmed anomalies (two stillborn neonates, one neonatal death, four live births). Two cases of CHD missed by first‐trimester STIC‐TUI echo were diagnosed on second‐trimester echo. Accordingly, first‐trimester STIC‐TUI echo had 91% sensitivity and 100% specificity for the detection of CHD.Conclusions: First‐trimester 4D echocardiography using a standardized application of STIC, TUI and color Doppler imaging is effective in displaying the imaging planes that are necessary for achieving the diagnosis of complex cardiac anomalies in high‐risk patients. Optimal imaging of the four‐chamber view with two‐dimensional ultrasound is the major determinant of successful volume acquisition. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.
- 29 May 2012
- Published by Georg Thieme Verlag KG in American Journal of Perinatology
- Vol. 29 (09) , 673-680
Comparative Analysis of 2-D Versus 3-D Ultrasound Estimation of the Fetal Adrenal Gland Volume and Prediction of Preterm Birth
Objective We aim to test the hypothesis that two-dimensional (2-D) fetal adrenal gland volume (AGV) measurements offer similar volume estimates as volume calculations based on 3-D technique. Methods Fetal AGV was estimated by three-dimensional (3-D) ultrasound (VOCAL) in 93 women with signs/symptoms of preterm labor and 73 controls. Fetal AGV was calculated using an ellipsoid formula derived from 2-D measurements of the same blocks (0.523 × length × width × depth). Comparisons were performed by intraclass correlation coefficient (ICC), coefficient of repeatability, and Bland-Altman method. The corrected AGV (cAGV; AGV/fetal weight) was calculated for both methods and compared for prediction of preterm birth (PTB) within 7 days. Results Among 168 volumes, there was a significant correlation between 3-D and 2-D methods (ICC = 0.979; 95% confidence interval [CI]: 0.971 to 0.984). The coefficient of repeatability for the 3-D was superior to the 2-D method (intraobserver 3-D: 30.8, 2-D:57.6; interobserver 3-D:12.2, 2-D: 15.6). Based on 2-D calculations, cAGV ≥ 433 mm3/kg was best for prediction of PTB (sensitivity: 75%, 95% CI = 59 to 87; specificity: 89%, 95% CI = 82 to 94). Sensitivity and specificity for the 3-D cAGV (cutoff ≥ 420 mm3/kg) was 85% (95% CI = 70 to 94) and 95% (95% CI = 90 to 98), respectively. In receiver-operating-curve curve analysis, 3-D cAGV was superior to 2-D cAGV for prediction of PTB (z = 1.99, p = 0.047). Conclusion 2-D volume estimation of fetal adrenal gland using ellipsoid formula cannot replace 3-D AGV calculations for prediction of PTB.
- 29 May 2012
- Published by Georg Thieme Verlag KG in American Journal of Perinatology
- Vol. 29 (09) , 673-680
Comparative Analysis of 2-D Versus 3-D Ultrasound Estimation of the Fetal Adrenal Gland Volume and Prediction of Preterm Birth
Objective We aim to test the hypothesis that two-dimensional (2-D) fetal adrenal gland volume (AGV) measurements offer similar volume estimates as volume calculations based on 3-D technique. Methods Fetal AGV was estimated by three-dimensional (3-D) ultrasound (VOCAL) in 93 women with signs/symptoms of preterm labor and 73 controls. Fetal AGV was calculated using an ellipsoid formula derived from 2-D measurements of the same blocks (0.523 × length × width × depth). Comparisons were performed by intraclass correlation coefficient (ICC), coefficient of repeatability, and Bland-Altman method. The corrected AGV (cAGV; AGV/fetal weight) was calculated for both methods and compared for prediction of preterm birth (PTB) within 7 days. Results Among 168 volumes, there was a significant correlation between 3-D and 2-D methods (ICC = 0.979; 95% confidence interval [CI]: 0.971 to 0.984). The coefficient of repeatability for the 3-D was superior to the 2-D method (intraobserver 3-D: 30.8, 2-D:57.6; interobserver 3-D:12.2, 2-D: 15.6). Based on 2-D calculations, cAGV ≥ 433 mm3/kg was best for prediction of PTB (sensitivity: 75%, 95% CI = 59 to 87; specificity: 89%, 95% CI = 82 to 94). Sensitivity and specificity for the 3-D cAGV (cutoff ≥ 420 mm3/kg) was 85% (95% CI = 70 to 94) and 95% (95% CI = 90 to 98), respectively. In receiver-operating-curve curve analysis, 3-D cAGV was superior to 2-D cAGV for prediction of PTB (z = 1.99, p = 0.047). Conclusion 2-D volume estimation of fetal adrenal gland using ellipsoid formula cannot replace 3-D AGV calculations for prediction of PTB.
- 31 January 2012
- Published by Elsevier in American Journal of Obstetrics and Gynecology
- Vol. 206 (1) , S173
370: Timing of arrested fetal brain growth in congenital heart disease (CHD)
- 31 January 2012
- Published by Elsevier in American Journal of Obstetrics and Gynecology
- Vol. 206 (1) , S173
370: Timing of arrested fetal brain growth in congenital heart disease (CHD)
- Open Access
- 28 April 2011
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 38 (3) , 325-331
Decreased fetal cardiac performance in the first trimester correlates with hyperglycemia in pregestational maternal diabetes
Objective: In‐vitroanimal studies suggest that high glucose levels impair fetal cardiac function early in gestation. We aimed to study whether evidence of first‐trimester myocardial dysfunction can be detected in fetuses of women with pregestational diabetes mellitus.Methods: Women with diabetes mellitus underwent fetal echocardiography at 11–14 weeks' gestational age. In fetuses with normal anatomy, the cardiac preload, diastolic function, global myocardial performance and placental afterload were studied by Doppler of the ductus venosus (DV), mitral and tricuspid early/atrial (E/A) ratios, left and right ventricular myocardial performance index (MPI) and umbilical artery (UA) Doppler, respectively. Cases were matched for gestational age and UA and DV Doppler with controls that had no diabetes mellitus.Results: Sixty‐three singleton diabetic pregnancies were matched with 63 controls. Mean gestational age at enrollment was 12.6 (range, 11.1–13.6) weeks. Diabetic mothers had moderate to poor glycemic control (median (range) glycosylated hemoglobin A1 (HbA1c), 7.5 (5.1–12.7)%, and the HbA1c level was ≥ 7% in 37 (59%)). Fetuses of diabetic mothers exhibited worse measures of diastolic dysfunction: the isovolumetric relaxation time (IRT) was significantly prolonged (left ventricle: 36.9 ± 7.4 ms vs. 45.8 ± 6.8 ms; right ventricle: 35.6 ± 8 ms vs. 46.4 ± 7.3 ms,P< 0.0001 for both). The mitral E/A ratio was lower in diabetics (0.55 ± 0.06 vs. 0.51 ± 0.08,P= 0.03), and the global myocardial performance was lower in both ventricles (left ventricle MPI: 0.5 ± 0.08; right ventricle MPI: 0.52 ± 0.08,P= 0.03 andP< 0.0001, respectively). This lower global myocardial performance was caused by a prolonged myocardial relaxation time, which was most marked in diabetics with an HbA1c of ≥ 7% (P< 0.001 vs. controls for both ventricles). There were no significant correlations between cardiac Doppler parameters and DV, UA indices and fetal heart rate (P> 0.05 for all).Conclusions: Fetuses of poorly controlled diabetic mothers demonstrate significant differences in first‐trimester diastolic myocardial function compared with non‐diabetic controls. The decrease in myocardial performance is more marked with increasing HbA1c and appears to be independent of preload and afterload. The ability to document these cardiac functional changes this early in pregnancy opens potential new avenues to understand the consequences of maternal glycemic status. Copyright © 2011 ISUOG. Published by John Wiley & Sons, Ltd.
- 28 April 2011
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 38 (3) , 325-331
Open AccessDecreased fetal cardiac performance in the first trimester correlates with hyperglycemia in pregestational maternal diabetes
Objective: In‐vitroanimal studies suggest that high glucose levels impair fetal cardiac function early in gestation. We aimed to study whether evidence of first‐trimester myocardial dysfunction can be detected in fetuses of women with pregestational diabetes mellitus.Methods: Women with diabetes mellitus underwent fetal echocardiography at 11–14 weeks' gestational age. In fetuses with normal anatomy, the cardiac preload, diastolic function, global myocardial performance and placental afterload were studied by Doppler of the ductus venosus (DV), mitral and tricuspid early/atrial (E/A) ratios, left and right ventricular myocardial performance index (MPI) and umbilical artery (UA) Doppler, respectively. Cases were matched for gestational age and UA and DV Doppler with controls that had no diabetes mellitus.Results: Sixty‐three singleton diabetic pregnancies were matched with 63 controls. Mean gestational age at enrollment was 12.6 (range, 11.1–13.6) weeks. Diabetic mothers had moderate to poor glycemic control (median (range) glycosylated hemoglobin A1 (HbA1c), 7.5 (5.1–12.7)%, and the HbA1c level was ≥ 7% in 37 (59%)). Fetuses of diabetic mothers exhibited worse measures of diastolic dysfunction: the isovolumetric relaxation time (IRT) was significantly prolonged (left ventricle: 36.9 ± 7.4 ms vs. 45.8 ± 6.8 ms; right ventricle: 35.6 ± 8 ms vs. 46.4 ± 7.3 ms,P< 0.0001 for both). The mitral E/A ratio was lower in diabetics (0.55 ± 0.06 vs. 0.51 ± 0.08,P= 0.03), and the global myocardial performance was lower in both ventricles (left ventricle MPI: 0.5 ± 0.08; right ventricle MPI: 0.52 ± 0.08,P= 0.03 andP< 0.0001, respectively). This lower global myocardial performance was caused by a prolonged myocardial relaxation time, which was most marked in diabetics with an HbA1c of ≥ 7% (P< 0.001 vs. controls for both ventricles). There were no significant correlations between cardiac Doppler parameters and DV, UA indices and fetal heart rate (P> 0.05 for all).Conclusions: Fetuses of poorly controlled diabetic mothers demonstrate significant differences in first‐trimester diastolic myocardial function compared with non‐diabetic controls. The decrease in myocardial performance is more marked with increasing HbA1c and appears to be independent of preload and afterload. The ability to document these cardiac functional changes this early in pregnancy opens potential new avenues to understand the consequences of maternal glycemic status. Copyright © 2011 ISUOG. Published by John Wiley & Sons, Ltd.
- 1 April 2011
- Published by Elsevier in American Journal of Obstetrics and Gynecology
- Vol. 204 (4) , 311.e1-311.e10
Ultrasound measurement of fetal adrenal gland enlargement: an accurate predictor of preterm birth
- 1 April 2011
- Published by Elsevier in American Journal of Obstetrics and Gynecology
- Vol. 204 (4) , 311.e1-311.e10
Ultrasound measurement of fetal adrenal gland enlargement: an accurate predictor of preterm birth
- 1 April 2007
- Published by Wolters Kluwer Health in Obstetrics & Gynecology
- Vol. 109 (4) , 855-862
Fetal Adrenal Gland Volume
To investigate the risk of preterm birth (delivery at less than 37 weeks of gestation) by evaluating the fetal adrenal gland volume, hallmark of activation of the fetal hypothalamic-pituitary-adrenal axis, measured by 3-dimensional ultrasonography. We performed 3-dimensional ultrasound examination of the fetal adrenal gland volume in 126 singleton fetuses, prospectively comparing those born to mothers with signs or symptoms of preterm labor (n=53) to control subjects (n=73). Multiplanar technique with rotational methods for measurement of fetal adrenal gland volume was performed by using Virtual Organ Computer-Aided Analysis (VOCAL) technology. The fetal adrenal gland volume was successfully examined in 86.5% of the cases. There was a direct relationship between the fetal adrenal gland volume and estimated fetal weight. A corrected adrenal gland volume of greater than 422 mm3/kg was best in predicting preterm birth within 5 days from the time of the measurement. The sensitivity, specificity, and positive and negative likelihood ratios were 92%, 99%, 93.5, and 0.08, respectively. Multiple logistic regression analysis showed that the corrected adrenal gland volume was the only significant independent predictor factor of preterm birth within 5 days of measurement. Corrected adrenal gland volume measurement may identify women at risk for impending preterm birth. This information can be generated noninvasively and in time for clinical decision making. II.
- 1 April 2007
- Published by Wolters Kluwer Health in Obstetrics & Gynecology
- Vol. 109 (4) , 855-862
Fetal Adrenal Gland Volume
To investigate the risk of preterm birth (delivery at less than 37 weeks of gestation) by evaluating the fetal adrenal gland volume, hallmark of activation of the fetal hypothalamic-pituitary-adrenal axis, measured by 3-dimensional ultrasonography. We performed 3-dimensional ultrasound examination of the fetal adrenal gland volume in 126 singleton fetuses, prospectively comparing those born to mothers with signs or symptoms of preterm labor (n=53) to control subjects (n=73). Multiplanar technique with rotational methods for measurement of fetal adrenal gland volume was performed by using Virtual Organ Computer-Aided Analysis (VOCAL) technology. The fetal adrenal gland volume was successfully examined in 86.5% of the cases. There was a direct relationship between the fetal adrenal gland volume and estimated fetal weight. A corrected adrenal gland volume of greater than 422 mm3/kg was best in predicting preterm birth within 5 days from the time of the measurement. The sensitivity, specificity, and positive and negative likelihood ratios were 92%, 99%, 93.5, and 0.08, respectively. Multiple logistic regression analysis showed that the corrected adrenal gland volume was the only significant independent predictor factor of preterm birth within 5 days of measurement. Corrected adrenal gland volume measurement may identify women at risk for impending preterm birth. This information can be generated noninvasively and in time for clinical decision making. II.