Malcolm R. Smyth
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Malcolm R. Smyth has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Anthony J. Killard
Department of Applied Sciences, University of the West of England, Bristol BS16 1QY, UK
11 shared publications - Aoife Morrin
School of Chemical Sciences, Insight Research Ireland Centre for Data Analytics, Dublin City University, D09 V209, Ireland
8 shared publications - Xiliang Luo
Qingdao University of Science and Technology
5 shared publications - Blánaid White
School of Chemical Sciences, Dublin City University, Dublin 9, Ireland
4 shared publications - Brian Gorey
National Centre for Sensor Research, School of Chemical Sciences, Dublin City University, Dublin 9, Ireland
2 shared publications - Emmanuel Iheanyichukwu Iwuoha
SensorLab (University of the Western Cape Sensor Laboratories) 4th Floor Chemical Sciences Building University of the Western Cape Bellville Cape Town South Africa
2 shared publications
Latest Publications
- 1 December 2014
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 436, 211-217
Fabrication of a 3-dimensional nanostructured binary colloidal crystal within a confined channel
- 1 December 2014
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 436, 211-217
Fabrication of a 3-dimensional nanostructured binary colloidal crystal within a confined channel
- Open Access
- 16 May 2012
- Published by Wiley in Electroanalysis
- Vol. 24 (6) , 1318-1323
Inverse‐Opal Conducting Polymer Monoliths in Microfluidic Channels
- 16 May 2012
- Published by Wiley in Electroanalysis
- Vol. 24 (6) , 1318-1323
Open AccessInverse‐Opal Conducting Polymer Monoliths in Microfluidic Channels
- 15 February 2008
- Published by Elsevier in Journal of Chromatography B
- Vol. 863 (1) , 181-186
Separation of oxidatively damaged DNA nucleobases and nucleosides on packed and monolith C18 columns by HPLC-UV-EC
- 15 February 2008
- Published by Elsevier in Journal of Chromatography B
- Vol. 863 (1) , 181-186
Separation of oxidatively damaged DNA nucleobases and nucleosides on packed and monolith C18 columns by HPLC-UV-EC
- 15 June 2007
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- No. 30,p. 3207-3209
Electrochemical preparation of distinct polyaniline nanostructures by surface charge control of polystyrene nanoparticle templates
A family of nanostructured polyaniline (PANI) materials including polystyrene (PS)/PANI core/shell particles, PANI hollow spheres, PANI/PS nanocomposite and nanoporous PANI, were conveniently prepared by surface charge control of PS nanoparticle templates which resulted in different polymer growth mechanisms when PANI was electropolymerized around the templates.
- 15 June 2007
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- No. 30,p. 3207-3209
Electrochemical preparation of distinct polyaniline nanostructures by surface charge control of polystyrene nanoparticle templates
A family of nanostructured polyaniline (PANI) materials including polystyrene (PS)/PANI core/shell particles, PANI hollow spheres, PANI/PS nanocomposite and nanoporous PANI, were conveniently prepared by surface charge control of PS nanoparticle templates which resulted in different polymer growth mechanisms when PANI was electropolymerized around the templates.
- 12 April 2007
- Published by Wiley in Electroanalysis
- Vol. 19 (7-8) , 876-883
Nanocauliflowers: A Nanostructured Polyaniline‐Modified Screen‐Printed Electrode with a Self‐Assembled Polystyrene Template and Its Application in an Amperometric Enzyme Biosensor
A simple method for the nanostructuring of polyaniline (PANI)‐modified screen‐printed electrodes (SPE) was developed. Polystyrene (PS) nanoparticles were self‐assembled onto a PANI‐modified SPE with the help of the negatively charged polyelectrolyte poly(sodium 4‐styrenesulfonate) (PSS) and positively charged poly(diallyldimethylammonium chloride) (PDDA). The self‐assembled PS nanoparticles could then act as a template for the electropolymerization of an additional layer of PANI. It was found that the additional layer of PANI preferred to grow around the PS nanoparticles, and a highly nodular, ‘cauliflower–like’ nanostructure of PANI was thus formed on the electrode surface, which was characterized by scanning electron microscopy. The SPE modified with the nanostructured PANI (nano‐PANI) was further used for the immobilization of horseradish peroxidase (HRP) and developed into a biosensor for hydrogen peroxide. Under optimized conditions, the proposed biosensor exhibited a fast response time of about 5 s, a linear range from 2.5×10−6 to 1.9×10−4 μM with a detection limit of 0.36 μM, and a high sensitivity of 41.0 μA mM−1 due to the benefits of the nanostructured PANI.
- 12 April 2007
- Published by Wiley in Electroanalysis
- Vol. 19 (7-8) , 876-883
Nanocauliflowers: A Nanostructured Polyaniline‐Modified Screen‐Printed Electrode with a Self‐Assembled Polystyrene Template and Its Application in an Amperometric Enzyme Biosensor
A simple method for the nanostructuring of polyaniline (PANI)‐modified screen‐printed electrodes (SPE) was developed. Polystyrene (PS) nanoparticles were self‐assembled onto a PANI‐modified SPE with the help of the negatively charged polyelectrolyte poly(sodium 4‐styrenesulfonate) (PSS) and positively charged poly(diallyldimethylammonium chloride) (PDDA). The self‐assembled PS nanoparticles could then act as a template for the electropolymerization of an additional layer of PANI. It was found that the additional layer of PANI preferred to grow around the PS nanoparticles, and a highly nodular, ‘cauliflower–like’ nanostructure of PANI was thus formed on the electrode surface, which was characterized by scanning electron microscopy. The SPE modified with the nanostructured PANI (nano‐PANI) was further used for the immobilization of horseradish peroxidase (HRP) and developed into a biosensor for hydrogen peroxide. Under optimized conditions, the proposed biosensor exhibited a fast response time of about 5 s, a linear range from 2.5×10−6 to 1.9×10−4 μM with a detection limit of 0.36 μM, and a high sensitivity of 41.0 μA mM−1 due to the benefits of the nanostructured PANI.
- 8 February 2007
- Published by Wiley in Chemistry – A European Journal
- Vol. 13 (7) , 2138-2143
Nanocomposite and Nanoporous Polyaniline Conducting Polymers Exhibit Enhanced Catalysis of Nitrite Reduction
Nanostructured polyaniline (PANI) conducting polymer films were prepared on electrochemically pretreated glassy carbon electrodes, which were previously modified with multilayers of polystyrene (PS) nanoparticles with a diameter of 100 nm. PANI was electropolymerised and grown through the interstitial spaces between the PS nanoparticles, which formed a nanocomposite film of PANI and PS nanoparticles on the electrode surface. Furthermore, a nanoporous PANI film was fabricated through the removal of the PS nanoparticles by dissolution in toluene. As a result of their nanostructure, both of the PANI films (before and after removal of the PS nanoparticles) exhibited enhanced electrocatalytic behaviour towards the reduction of nitrite relative to bulk‐PANI films; however, partial collapse or shrinkage may have occurred with the removal of the nanoparticles and could have resulted in a less enhanced response. Under optimised conditions, the nanocomposite‐film‐modified electrode exhibited a fast response time of 5 s and a linear range from 5.0×10−7 to 1.4×10−3 M for the detection of nitrite; the detection limit was 2.4×10−7 M at a signal‐to‐noise ratio of 3.
- 8 February 2007
- Published by Wiley in Chemistry – A European Journal
- Vol. 13 (7) , 2138-2143
Nanocomposite and Nanoporous Polyaniline Conducting Polymers Exhibit Enhanced Catalysis of Nitrite Reduction
Nanostructured polyaniline (PANI) conducting polymer films were prepared on electrochemically pretreated glassy carbon electrodes, which were previously modified with multilayers of polystyrene (PS) nanoparticles with a diameter of 100 nm. PANI was electropolymerised and grown through the interstitial spaces between the PS nanoparticles, which formed a nanocomposite film of PANI and PS nanoparticles on the electrode surface. Furthermore, a nanoporous PANI film was fabricated through the removal of the PS nanoparticles by dissolution in toluene. As a result of their nanostructure, both of the PANI films (before and after removal of the PS nanoparticles) exhibited enhanced electrocatalytic behaviour towards the reduction of nitrite relative to bulk‐PANI films; however, partial collapse or shrinkage may have occurred with the removal of the nanoparticles and could have resulted in a less enhanced response. Under optimised conditions, the nanocomposite‐film‐modified electrode exhibited a fast response time of 5 s and a linear range from 5.0×10−7 to 1.4×10−3 M for the detection of nitrite; the detection limit was 2.4×10−7 M at a signal‐to‐noise ratio of 3.
- 31 July 2006
- Published by Elsevier in Journal of Inorganic Biochemistry
- Vol. 100 (7) , 1252-1259
Production and characterization of a polyclonal antibody for Os(II) and Ru(II) polypyridyl complexes
- 31 July 2006
- Published by Elsevier in Journal of Inorganic Biochemistry
- Vol. 100 (7) , 1252-1259
Production and characterization of a polyclonal antibody for Os(II) and Ru(II) polypyridyl complexes
- 30 May 2006
- Published by Wiley in Electroanalysis
- Vol. 18 (11) , 1131-1134
Reagentless Glucose Biosensor Based on the Direct Electrochemistry of Glucose Oxidase on Carbon Nanotube‐Modified Electrodes
The direct electrochemistry of glucose oxidase (GOD) was revealed at a carbon nanotube (CNT)‐modified glassy carbon electrode, where the enzyme was immobilized with a chitosan film containing gold nanoparticles. The immobilized GOD displays a pair of redox peaks in pH 7.4 phosphate buffer solutions (PBS) with the formal potential of about −455 mV (vs. Ag/AgCl) and shows a surface‐controlled electrode process. Bioactivity remains good, along with effective catalysis of the reduction of oxygen. In the presence of dissolved oxygen, the reduction peak current decreased gradually with the addition of glucose, which could be used for reagentless detection of glucose with a linear range from 0.04 to 1.0 mM. The proposed glucose biosensor exhibited high sensitivity, good stability and reproducibility, and was also insensitive to common interferences such as ascorbic and uric acid. The excellent performance of the reagentless biosensor is attributed to the effective enhancement of electron transfer between enzyme and electrode surface by CNTs, and the biocompatible environment that the chitosan film containing gold nanoparticles provides for immobilized GOD.
- 30 May 2006
- Published by Wiley in Electroanalysis
- Vol. 18 (11) , 1131-1134
Reagentless Glucose Biosensor Based on the Direct Electrochemistry of Glucose Oxidase on Carbon Nanotube‐Modified Electrodes
The direct electrochemistry of glucose oxidase (GOD) was revealed at a carbon nanotube (CNT)‐modified glassy carbon electrode, where the enzyme was immobilized with a chitosan film containing gold nanoparticles. The immobilized GOD displays a pair of redox peaks in pH 7.4 phosphate buffer solutions (PBS) with the formal potential of about −455 mV (vs. Ag/AgCl) and shows a surface‐controlled electrode process. Bioactivity remains good, along with effective catalysis of the reduction of oxygen. In the presence of dissolved oxygen, the reduction peak current decreased gradually with the addition of glucose, which could be used for reagentless detection of glucose with a linear range from 0.04 to 1.0 mM. The proposed glucose biosensor exhibited high sensitivity, good stability and reproducibility, and was also insensitive to common interferences such as ascorbic and uric acid. The excellent performance of the reagentless biosensor is attributed to the effective enhancement of electron transfer between enzyme and electrode surface by CNTs, and the biocompatible environment that the chitosan film containing gold nanoparticles provides for immobilized GOD.
- Top Cited Papers
- 15 February 2006
- Published by Wiley in Electroanalysis
- Vol. 18 (4) , 319-326
Application of Nanoparticles in Electrochemical Sensors and Biosensors
The unique chemical and physical properties of nanoparticles make them extremely suitable for designing new and improved sensing devices, especially electrochemical sensors and biosensors. Many kinds of nanoparticles, such as metal, oxide and semiconductor nanoparticles have been used for constructing electrochemical sensors and biosensors, and these nanoparticles play different roles in different sensing systems. The important functions provided by nanoparticles include the immobilization of biomolecules, the catalysis of electrochemical reactions, the enhancement of electron transfer between electrode surfaces and proteins, labeling of biomolecules and even acting as reactant. This minireview addresses recent advances in nanoparticle‐based electrochemical sensors and biosensors, and summarizes the main functions of nanoparticles in these sensor systems.
- 15 February 2006
- Published by Wiley in Electroanalysis
- Vol. 18 (4) , 319-326
Top Cited PapersApplication of Nanoparticles in Electrochemical Sensors and Biosensors
The unique chemical and physical properties of nanoparticles make them extremely suitable for designing new and improved sensing devices, especially electrochemical sensors and biosensors. Many kinds of nanoparticles, such as metal, oxide and semiconductor nanoparticles have been used for constructing electrochemical sensors and biosensors, and these nanoparticles play different roles in different sensing systems. The important functions provided by nanoparticles include the immobilization of biomolecules, the catalysis of electrochemical reactions, the enhancement of electron transfer between electrode surfaces and proteins, labeling of biomolecules and even acting as reactant. This minireview addresses recent advances in nanoparticle‐based electrochemical sensors and biosensors, and summarizes the main functions of nanoparticles in these sensor systems.
- Open Access
- 9 January 2006
- Published by Wiley in Electroanalysis
- Vol. 18 (1) , 77-81
Development and Characterization of Nickel‐NTA‐Polyaniline Modified Electrodes
The engineered addition of hexa‐histidine sequences to biomolecules such as antibody fragments has been found to be an excellent means of purifying these materials. This tagging methodology has also been extended to its use as a tool for immobilization and orientation of antibodies on transducer surfaces. Polyvinyl sulfonate‐doped polyanilne (PANI/PVS) can be used as a mediator in amperometric biosensors. This short communication looks at the effect of nickel chelate materials and nickel chelation on this conducting polymer and evaluates it as a potential surface for the immobilization of his‐tagged biomolecules. N‐nitrilotriacetic acid (NTA) was doped into the electropolymerized PANI/PVS at a screen‐printed carbon paste electrode. The resulting NTA‐PANI/PVS film was shown to have comparable electrochemical properties of polymer without the chelating agent. When Ni2+ was applied to the electrode, the incorporated NTA was found to efficiently chelate the metal ions at the electrode surface.
- 9 January 2006
- Published by Wiley in Electroanalysis
- Vol. 18 (1) , 77-81
Open AccessDevelopment and Characterization of Nickel‐NTA‐Polyaniline Modified Electrodes
The engineered addition of hexa‐histidine sequences to biomolecules such as antibody fragments has been found to be an excellent means of purifying these materials. This tagging methodology has also been extended to its use as a tool for immobilization and orientation of antibodies on transducer surfaces. Polyvinyl sulfonate‐doped polyanilne (PANI/PVS) can be used as a mediator in amperometric biosensors. This short communication looks at the effect of nickel chelate materials and nickel chelation on this conducting polymer and evaluates it as a potential surface for the immobilization of his‐tagged biomolecules. N‐nitrilotriacetic acid (NTA) was doped into the electropolymerized PANI/PVS at a screen‐printed carbon paste electrode. The resulting NTA‐PANI/PVS film was shown to have comparable electrochemical properties of polymer without the chelating agent. When Ni2+ was applied to the electrode, the incorporated NTA was found to efficiently chelate the metal ions at the electrode surface.