GKGünay Kocasoy

Günay Kocasoy

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Günay Kocasoy has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • Hayat Yalin

    Institute of Environmental Sciences , Boǧaziçi University , Istanbul, Turkey

    1 shared publication
  • Mustafa Balkan

    Institute of Environmental Sciences, Bogazici University, Bebek, Istanbul, Turkey

    1 shared publication
  • Sibel Sezer

    National Programme on Environment and Development, Ministry of Environment, Eskişehir Yolu 8 km, Ankara, Turkey

    1 shared publication
  • Vicdan Şahin

    Boğaziçi University,Institute of Environmental Sciences , Bebek , İstanbul , Turkey

    1 shared publication
  • Zeynep Güvener

    Institute of Environmental Sciences, Bogazici University, Bebek, Istanbul, Turkey

    1 shared publication
  • Zeynep Melda Murat

    Institute of Environmental Sciences , Boğaziçi University , Hisar Campus, Bebek, Istanbul, Turkey

    1 shared publication

Latest Publications

  • Determination of treatment method of leachate by using eluate

    by Günay Kocasoy

    The purpose of the research was to investigate if the treatment method for the leachate generated at the landfills can be determined by using the eluate obtained from the same solid waste to be dumped at the landfill area. The eluate was generated by using the Standard Leaching Test (SLT-3) and was analyzed for pH, Biochemical Oxygen Demand (BOD), Chemical Oxygen Demand (COD), eleven metals and inorganics. Also leachate was sampled from a sanitary landfill and analyzed for the same parameters. The composition of the eluate and the leachate was compared and it was observed that the generated eluate resembles the leachate. Then coagulation and flocculation tests using 8M aluminium sulphate (Al2 (SO4)3) and 1M FeCl3 at acidic and basic media were applied and some of the treated eluate was filtered through activated carbon. The results indicated that although the applied coagulation and flocculation processes in the acidic media were effective in the removal of COD from the eluate, it was not effective in the removal of metal and inorganic elements while the opposite was true at the basic media. High removal efficiency of the metal and inorganic elements was obtained by using 15 mL 1M iron chloride at basic media (pH 9) and then filtering through activated carbon. By the application of the filtration through activated carbon approximately 80 percent removal efficiency for both BOD and COD of the eluate and leachate were obtained. The results of the research indicated that eluate resembling the leachate, which can be obtained by the SLT-3 method using the solid waste to be disposed at the sanitary landfill, can be used for the determination of the treatment method for the treatment of the leachate to be generated later.


  • Comparison of the characteristics of the leachate and the eluates obtained by different methods

    by Günay Kocasoy, Zeynep Melda Murat

    In the research conducted, the interrelation between the leachate and eluates obtained by different methods was determined. The purpose of this research is to determine the optimum method yielding the eluates resembling the leachate generated from the same solid waste. Two reactors filled with solid waste, simulating to a certain extent the sanitary landfill conditions, were used for the generation of leachate. Eluates from the same solid waste that was filled in the reactors were produced by different methods – Standard Leaching Test (SLT), International Unit Conversion System (IUCS) 48 Hours Shaking Test, Minnesota Test and Deutches Institut für Normung (DIN) 38414-S4 Test. Then both the leachate generated in the reactors and the eluates obtained were analyzed for pH, biological oxygen demand (BOD), chemical oxygen demand (COD), 11 metals and inorganic elements and the results obtained were compared. The BOD and COD values of the SLT third day eluation have higher values than the eluates obtained by other methods. pH values of all the eluates are close to each other. The BOD, COD, Cu, Mn, Zn values of eluates obtained by SLT third eluation have the highest conformity to the leachate generated in reactors. The ratios of the average BOD, COD, Cu, Mg, Mn, Ni and Zn values of the leachate generated at the reactors to eluate are 0.9, 1.2, 0.65, 20, 1, 2.5 and 0.5, respectively. The average value of Ca concentration of the same eluate is 35 times lower than the average values of the leachate generated of the reactors. The eluate obtained by DIN 38414-S4 test has closest Fe and Pb values to the values of the leachate, but still Fe value is four times less than the average Fe values of the reactors. The ratio of Pb values of leachate to eluate is 0.6. The results showed that the SLT third day eluation yields the eluate having the closest values to the characteristics of the leachate generated at the reactors.


  • Heavy metal removal from industrial wastewater by clinoptilolite

    by Günay Kocasoy, Vicdan Şahin

    Clinoptilolite- a natural zeolite has been investigated for the removal of heavy metals from the wastewaters. A pyrex-glass column of 30 mm diameter and 600 mm height was used. The column was filled with the conditioned clinoptilolite of 0.5–1 mm. In the first stage of the research, synthetic wastewater containing single cation 0.02 N and 0.04 N Cu and 0.02 N Fe and Zn solutions were passed through the column. Two liter of 0.02 N Cu and 750 ml of the 0.04 N Cu solution was treated with 100 percent removal efficiency. Clinoptilolite column was regenerated for the reuse when the removal efficiency decreased. The cation exchange capacities were calculated as 1.0663 and 1.5342 meq/g clinoptilolite for 0.02 N and 0.04 N Cu solutions, respectively. In the second stage of this research, the same procedure was repeated with the actual wastewater samples of the equalization and the neutralization tanks of the Telka-Rabak Electrolytic Copper Industry. A volume of 1811 ml of the wastewater of the equalization tank and 180 ml of the neutralization tank wastewater, which had high concentrations of Ni, Zn, Cu and Fe, was treated with 100 percent efficiency. The cation exchange capacities of clinoptilolite for the wastewater of the equalization and the neutralization tanks for Cu were 0.4483 and 0.4274, respectively. It was observed that only one third of the single copper ion solutions were obtained with the actual wastewater having competing ions such as Zn, Fe and Ni. The experimental results also indicate that the clinoptilolite is an effective cation exchanger for the removal of the metals from the wastewater and the removal efficiency is higher when there is not ant competing ions.


  • Industrial Sludge Solidification by Using Clinoptilolite

    by Mustafa Balkan, Günay Kocasoy

    The sludge from metal plating industry is generally considered as “hazardous waste” due to its toxic heavy metal content. Solidification/stabilization techniques which are applied as prior to landfill give good results for the disposal of especially inorganic sludges into the landfill in a safe manner. The research is aimed to investigate an effective and low cost solidification technique for the sludge of a metal plating factory by using different particle sizes of clinoptilolite. Clinoptilolite is a kind of natural zeolite and it was used due to its good pozzolanic characteristic and its abundant reserves in Turkey. According to the results, clinoptilolite was found as a successful solidification additive yielding products with high unconfined compressive strength and low leaching.


  • Determination of Carboxyhemoglobin Levels and Health Effects on Officers Working at the Istanbul Bosphorus Bridge

    by Günay Kocasoy, Hayat Yalin

    Urban air pollution is a problem throughout the world. Carbon monoxide (CO), one of the major air pollutants, is an odorless, colorless, tasteless, and toxic gas, which is mainly produced by incomplete combustion of the fossil fuels such as gasoline and kerosene. The main outdoor sources of CO gas are vehicle exhausts, industrial effluents, and fires. When inhaled CO gas causes occupational hazards especially on workers who work at the junctions of heavy traffic roads and at the inefficiently ventilated closed areas such as parking garages and car repair shops. The purpose of this research was to determine the relation between carboxyhemoglobin (COHb) and CO levels and its health effects on cashiers working at the Istanbul Bosphorus Bridge. In the research the carbon monoxide and carboxyhemoglobin levels in the alveolar air of the numbers of the test group and the control group were measured and a questionnaire consisting of questions related to the personal information, their habitats as smoking or not smoking and the health conditions of the test and control group members were filled by interviewing them. The data obtained was analyzed by using Microsoft Excel Table Graphic Program, Chi-Square (2) Test and the Student-t Test. The results indicated that smokers are affected more by the CO than the nonsmokers.


  • Preface

    by Günay Kocasoy