Kiyokatsu Jinno
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kiyokatsu Jinno has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
Yoshihiro Saito
School of Materials Science , Toyohashi University of Technology , Toyohashi, Japan
21 shared publications- Noel S. Quiming
School of Materials Science, Toyohashi University of Technology, Toyohashi, Japan
8 shared publications Nerissa L. Denola
Toyohashi University of Technology
7 shared publicationsMitsuhiro Ogawa
School of Materials Science, Toyohashi University of Technology , Tempaku-cho, Toyohashi, Japan
6 shared publicationsTsutomu Takeichi
School of Materials Science, Toyohashi University of Technology, Toyohashi, Japan. Fax: +81‐532‐48‐5833
6 shared publicationsY. Saito
Toyohashi University of Technology
6 shared publications
Latest Publications
- 17 April 2009
- Published by Taylor & Francis in Journal of Liquid Chromatography & Related Technologies
- Vol. 32 (10) , 1407-1422
Sensitive Micellar Electrokinetic Chromatographic Determination of Salbutamol, Guaifenesin, and Dyphylline in Oral Formulations
A sensitive micellar electrokinetic chromatographic method to analyze salbutamol, guaifenesin, and dyphylline employing 20 µm inner diameter capillaries was developed. Sensitive analysis of the drugs at a concentration range of about 0.5 to 60 µg/mL was demonstrated using large volume sample stacking with 75% acetonitrile as the sample diluent. Using dyphylline as the internal standard, detection limits were 0.07 µg/mL and 0.21 µg/mL for salbutamol and guaifenesin, respectively. Using the standard addition method, accurate determination of salbutamol and guaifenesin in syrup and capsule preparations was achieved. Recovery values were satisfactory (95 to 100%), but matrix interferences affected the reproducibility.
- 17 April 2009
- Published by Taylor & Francis in Journal of Liquid Chromatography & Related Technologies
- Vol. 32 (10) , 1407-1422
Sensitive Micellar Electrokinetic Chromatographic Determination of Salbutamol, Guaifenesin, and Dyphylline in Oral Formulations
A sensitive micellar electrokinetic chromatographic method to analyze salbutamol, guaifenesin, and dyphylline employing 20 µm inner diameter capillaries was developed. Sensitive analysis of the drugs at a concentration range of about 0.5 to 60 µg/mL was demonstrated using large volume sample stacking with 75% acetonitrile as the sample diluent. Using dyphylline as the internal standard, detection limits were 0.07 µg/mL and 0.21 µg/mL for salbutamol and guaifenesin, respectively. Using the standard addition method, accurate determination of salbutamol and guaifenesin in syrup and capsule preparations was achieved. Recovery values were satisfactory (95 to 100%), but matrix interferences affected the reproducibility.
- 6 September 2008
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 393 (1) , 137-153
Modeling of retention of adrenoreceptor agonists and antagonists on polar stationary phases in hydrophilic interaction chromatography: a review
Retention prediction models for reversed-phase liquid chromatography (RPLC) have been extensively studied owing to the fact that RPLC remains the most widely used chromatographic technique especially in the field of pharmaceutical and biomedical analyses. However, RPLC is not always the method of choice for the analysis of some compounds that have high polarity. Hydrophilic interaction chromatography (HILIC) has been gaining interest in the last few years as an alternative option to RPLC for the analysis of polar and hydrophilic analytes. HILIC is a variant of normal-phase liquid chromatography, but utilizes water in a water-miscible organic solvent as the eluent in conjunction with a hydrophilic stationary phase. The present review aims to summarize recent contributions on the development of retention prediction models for a group of basic analytes, namely, the adrenoreceptor agonists and antagonists, on different polar stationary phases. The use of multiple linear regression and artificial neural networks in model building is highlighted.
- 6 September 2008
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 393 (1) , 137-153
Modeling of retention of adrenoreceptor agonists and antagonists on polar stationary phases in hydrophilic interaction chromatography: a review
Retention prediction models for reversed-phase liquid chromatography (RPLC) have been extensively studied owing to the fact that RPLC remains the most widely used chromatographic technique especially in the field of pharmaceutical and biomedical analyses. However, RPLC is not always the method of choice for the analysis of some compounds that have high polarity. Hydrophilic interaction chromatography (HILIC) has been gaining interest in the last few years as an alternative option to RPLC for the analysis of polar and hydrophilic analytes. HILIC is a variant of normal-phase liquid chromatography, but utilizes water in a water-miscible organic solvent as the eluent in conjunction with a hydrophilic stationary phase. The present review aims to summarize recent contributions on the development of retention prediction models for a group of basic analytes, namely, the adrenoreceptor agonists and antagonists, on different polar stationary phases. The use of multiple linear regression and artificial neural networks in model building is highlighted.
- 8 August 2008
- Published by Wiley in Journal of Separation Science
- Vol. 31 (14) , 2701-2706
Effects of alcohols on CE enantioseparation of basic drugs with native γ‐CD as chiral selector
The effects of alcohol on the CE enantioseparation of selected basic drugs with γ‐CD as the chiral selector was investigated. The enantioseparation behavior of the analytes with γ‐CD in the absence and presence of different alcohols specifically methanol, ethanol, 2‐propanol (IPA), and 2‐methyl‐2‐propanol (TBA), the relationship of enantiomeric resolution (Rs) values with either hydrophobicity or bulkiness of the alcohols, as well as the effect of these alcohols on interaction of the analytes with γ‐CD were studied. Results showed that hydrophobicity and/or bulkiness of alcohols have an influence on the enantioresolution of most of the analytes based on the relatively high correlation coefficients (R) obtained between Rs versus log P and between Rs versus ovality (i.e., parameter to indicate bulkiness of a molecule). Comparison of the values of the average binding constants obtained for each enantiomeric pair in the presence and absence of 5% IPA showed that alcohols can increase, decrease, or give a minimal effect on the analyte‐γ‐CD interaction depending on the analyte. Furthermore, the significant enhancement in the enantioresolution of both propranolol and pindolol in the presence of either IPA or TBA led to the baseline enantioresolution of both drugs using 35 mM γ‐CD.
- 8 August 2008
- Published by Wiley in Journal of Separation Science
- Vol. 31 (14) , 2701-2706
Effects of alcohols on CE enantioseparation of basic drugs with native γ‐CD as chiral selector
The effects of alcohol on the CE enantioseparation of selected basic drugs with γ‐CD as the chiral selector was investigated. The enantioseparation behavior of the analytes with γ‐CD in the absence and presence of different alcohols specifically methanol, ethanol, 2‐propanol (IPA), and 2‐methyl‐2‐propanol (TBA), the relationship of enantiomeric resolution (Rs) values with either hydrophobicity or bulkiness of the alcohols, as well as the effect of these alcohols on interaction of the analytes with γ‐CD were studied. Results showed that hydrophobicity and/or bulkiness of alcohols have an influence on the enantioresolution of most of the analytes based on the relatively high correlation coefficients (R) obtained between Rs versus log P and between Rs versus ovality (i.e., parameter to indicate bulkiness of a molecule). Comparison of the values of the average binding constants obtained for each enantiomeric pair in the presence and absence of 5% IPA showed that alcohols can increase, decrease, or give a minimal effect on the analyte‐γ‐CD interaction depending on the analyte. Furthermore, the significant enhancement in the enantioresolution of both propranolol and pindolol in the presence of either IPA or TBA led to the baseline enantioresolution of both drugs using 35 mM γ‐CD.
- 23 May 2008
- Published by Wiley in Journal of Separation Science
- Vol. 31 (9) , 1537-1549
Development of retention prediction models for adrenoreceptor agonists and antagonists on a polyvinyl alcohol‐bonded stationary phase in hydrophilic interaction chromatography
Retention prediction models based on multiple linear regression (MLR) and artificial neural network (ANN) for adrenoreceptor agonists and antagonists chromatographed on a polyvinyl alcohol‐bonded stationary phase under hydrophilic interaction chromatography were described. The models showed the combined effects of solute structure and mobile phase composition on the retention behavior of the analytes. Using stepwise MLR, the retentions of the studied compounds were satisfactorily described by a five‐predictor model; the predictors being the %ACN, the logarithm of the partition coefficient (log D), the number of hydrogen bond donors (HBD), the desolvation energy for octanol (FOct), and the total absolute atomic charge (TAAC). The inclusion of the solute‐related descriptors suggested that hydrophilic interactions such as hydrogen bonding and also ionic interactions are possible mechanisms by which analytes are retained on the studied system. ANN prediction models were also derived using the predictors derived from MLR as inputs and log k as outputs. The best network architectures were found to be 5‐3‐1 for the datasets at pH 3.0 and 4.0, and 5‐4‐1 for the dataset at pH 5.0. The optimized ANNs showed better predictive properties than the MLR models for both training and test sets under all pH conditions.
- 23 May 2008
- Published by Wiley in Journal of Separation Science
- Vol. 31 (9) , 1537-1549
Development of retention prediction models for adrenoreceptor agonists and antagonists on a polyvinyl alcohol‐bonded stationary phase in hydrophilic interaction chromatography
Retention prediction models based on multiple linear regression (MLR) and artificial neural network (ANN) for adrenoreceptor agonists and antagonists chromatographed on a polyvinyl alcohol‐bonded stationary phase under hydrophilic interaction chromatography were described. The models showed the combined effects of solute structure and mobile phase composition on the retention behavior of the analytes. Using stepwise MLR, the retentions of the studied compounds were satisfactorily described by a five‐predictor model; the predictors being the %ACN, the logarithm of the partition coefficient (log D), the number of hydrogen bond donors (HBD), the desolvation energy for octanol (FOct), and the total absolute atomic charge (TAAC). The inclusion of the solute‐related descriptors suggested that hydrophilic interactions such as hydrogen bonding and also ionic interactions are possible mechanisms by which analytes are retained on the studied system. ANN prediction models were also derived using the predictors derived from MLR as inputs and log k as outputs. The best network architectures were found to be 5‐3‐1 for the datasets at pH 3.0 and 4.0, and 5‐4‐1 for the dataset at pH 5.0. The optimized ANNs showed better predictive properties than the MLR models for both training and test sets under all pH conditions.
- 23 May 2008
- Published by Wiley in Journal of Separation Science
- Vol. 31 (9) , 1550-1563
Multiple linear regression and artificial neural network retention prediction models for ginsenosides on a polyamine‐bonded stationary phase in hydrophilic interaction chromatography
The development of retention prediction models for the seven ginsenosides Rf, Rg1, Rd, Re, Rc, Rb2, and Rb1 on a polyamine‐bonded stationary phase in hydrophilic interaction chromatography (HILIC) is presented. The models were derived using multiple linear regression (MLR) and artificial neural network (ANN) using the logarithm of the retention factor (log k) as the dependent variable for four temperature conditions (0, 10, 25, and 40°C). Using stepwise MLR, the retention of the analytes in all the temperature conditions was satisfactorily described by a two‐predictor model wherein the predictors were the percentage of ACN (%ACN) in the mobile phase and local dipole index (LDI) of the compounds. These predictors account for the contribution of the solute‐related variable (LDI) and the influence of the mobile phase composition (%ACN) on the retention behavior of the ginsenosides. A comparison of the models derived from both MLR and ANN revealed that the trained ANNs showed better predictive abilities than the MLR models in all temperature conditions as demonstrated by their higher R2 values for both training and test sets and lower average percentage deviation of the predicted log k from the observed log k of the test compounds. The ANN models also showed excellent performance when applied to the prediction of the seven ginsenosides in different sample matrices.
- 23 May 2008
- Published by Wiley in Journal of Separation Science
- Vol. 31 (9) , 1550-1563
Multiple linear regression and artificial neural network retention prediction models for ginsenosides on a polyamine‐bonded stationary phase in hydrophilic interaction chromatography
The development of retention prediction models for the seven ginsenosides Rf, Rg1, Rd, Re, Rc, Rb2, and Rb1 on a polyamine‐bonded stationary phase in hydrophilic interaction chromatography (HILIC) is presented. The models were derived using multiple linear regression (MLR) and artificial neural network (ANN) using the logarithm of the retention factor (log k) as the dependent variable for four temperature conditions (0, 10, 25, and 40°C). Using stepwise MLR, the retention of the analytes in all the temperature conditions was satisfactorily described by a two‐predictor model wherein the predictors were the percentage of ACN (%ACN) in the mobile phase and local dipole index (LDI) of the compounds. These predictors account for the contribution of the solute‐related variable (LDI) and the influence of the mobile phase composition (%ACN) on the retention behavior of the ginsenosides. A comparison of the models derived from both MLR and ANN revealed that the trained ANNs showed better predictive abilities than the MLR models in all temperature conditions as demonstrated by their higher R2 values for both training and test sets and lower average percentage deviation of the predicted log k from the observed log k of the test compounds. The ANN models also showed excellent performance when applied to the prediction of the seven ginsenosides in different sample matrices.
- 5 March 2008
- Published by Springer Nature in Chromatographia
- Vol. 67 (7-8) , 507-515
Chromatographic Behavior of Uric Acid and Methyl Uric Acids on a Diol Column in HILIC
- 5 March 2008
- Published by Springer Nature in Chromatographia
- Vol. 67 (7-8) , 507-515
Chromatographic Behavior of Uric Acid and Methyl Uric Acids on a Diol Column in HILIC
- 1 October 2007
- Published by Wiley in Electrophoresis
- Vol. 28 (19) , 3542-3552
Simultaneous enantioseparation and sensitivity enhancement of basic drugs using large‐volume sample stacking
Simultaneous enantioseparation with sensitive detection of four basic drugs, namely methoxamine, metaproterenol, terbutaline and carvedilol, using a 20-μm ID capillary with native β-CD as the chiral selector was demonstrated by the large-volume sample stacking method. The procedure included conventional sample loading either hydrodynamically or electrokinetically at longer injection times without polarity switching and EOF manipulation. In comparison to conventional injections, depending on the analyte, about several hundred- and a thousand-fold sensitivity enhancement was achieved with the hydrodynamic and the electrokinetic injections, respectively. The simple method developed was applied to the analysis of racemic analytes in serum samples and better recovery was achieved using hydrodynamic injection than electrokinetic injection.
- 1 October 2007
- Published by Wiley in Electrophoresis
- Vol. 28 (19) , 3542-3552
Simultaneous enantioseparation and sensitivity enhancement of basic drugs using large‐volume sample stacking
Simultaneous enantioseparation with sensitive detection of four basic drugs, namely methoxamine, metaproterenol, terbutaline and carvedilol, using a 20-μm ID capillary with native β-CD as the chiral selector was demonstrated by the large-volume sample stacking method. The procedure included conventional sample loading either hydrodynamically or electrokinetically at longer injection times without polarity switching and EOF manipulation. In comparison to conventional injections, depending on the analyte, about several hundred- and a thousand-fold sensitivity enhancement was achieved with the hydrodynamic and the electrokinetic injections, respectively. The simple method developed was applied to the analysis of racemic analytes in serum samples and better recovery was achieved using hydrodynamic injection than electrokinetic injection.
- 6 September 2007
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 389 (5) , 1477-1488
Retention behavior of ginsenosides on a poly(vinyl alcohol)-bonded stationary phase in hydrophilic interaction chromatography
The influences of the organic component of the mobile phase and the column temperature on the retention of ginsenosides on a poly(vinyl alcohol) (PVA) bonded stationary phase operated under hydrophilic interaction chromatographic mode were investigated. The retention of the ginsenosides was found to increase with increasing amount of acetonitrile (MeCN) in the mobile phase, which is typical of hydrophilic interaction chromatographic behavior. It was also found that the retention of the analytes was highly affected by the type of the organic modifier used. Aqueous MeCN (75–90%) gave the most satisfactory retention and separation of ginsenosides Rf, Rg1, Rd, Re, Rc, Rb2 and Rb1 compared with aqueous methanol, isopropyl alcohol or tetrahydrofuran at the same composition levels. The effects of the different types of organic modifiers on the retention of the analytes were attributed to their solvent strength and hydrogen-bond accepting/donating properties. The effect of temperature on the retention of ginsenoside on the PVA-bonded phase was assessed by constructing van’t Hoff plots for two temperature ranges: subambient (273–293 K) and ambient-elevated (298–333 K) temperatures. van’t Hoff plots for all analytes were linear at the two temperature intervals; however, the slopes of the lines corresponding to ginsenosides Rg1 and Re were completely different from those for the rest of the analytes especially in the subambient temperature range. Enthalpy-entropy compensation (EEC) studies were conducted to verify the difference in thermodynamics observed for ginsenosides Rg1 and Re compared with the other analytes. EEC plots showed that Rf, Rd, Rc, Rb2 and Rb1 were possibly retained by the same retention mechanism, which was completely different from that of Rg1 and Re at subambient temperatures. Retention prediction models were derived using multiple linear regression to identify solute attributes that affected the retention of the analytes on the PVA-bonded phase. The mathematical models derived revealed that the number of hydrogen-bond donors and the ovality of the molecules are important molecular properties that govern the retention of the compounds on the chromatographic system.
- 6 September 2007
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 389 (5) , 1477-1488
Retention behavior of ginsenosides on a poly(vinyl alcohol)-bonded stationary phase in hydrophilic interaction chromatography
The influences of the organic component of the mobile phase and the column temperature on the retention of ginsenosides on a poly(vinyl alcohol) (PVA) bonded stationary phase operated under hydrophilic interaction chromatographic mode were investigated. The retention of the ginsenosides was found to increase with increasing amount of acetonitrile (MeCN) in the mobile phase, which is typical of hydrophilic interaction chromatographic behavior. It was also found that the retention of the analytes was highly affected by the type of the organic modifier used. Aqueous MeCN (75–90%) gave the most satisfactory retention and separation of ginsenosides Rf, Rg1, Rd, Re, Rc, Rb2 and Rb1 compared with aqueous methanol, isopropyl alcohol or tetrahydrofuran at the same composition levels. The effects of the different types of organic modifiers on the retention of the analytes were attributed to their solvent strength and hydrogen-bond accepting/donating properties. The effect of temperature on the retention of ginsenoside on the PVA-bonded phase was assessed by constructing van’t Hoff plots for two temperature ranges: subambient (273–293 K) and ambient-elevated (298–333 K) temperatures. van’t Hoff plots for all analytes were linear at the two temperature intervals; however, the slopes of the lines corresponding to ginsenosides Rg1 and Re were completely different from those for the rest of the analytes especially in the subambient temperature range. Enthalpy-entropy compensation (EEC) studies were conducted to verify the difference in thermodynamics observed for ginsenosides Rg1 and Re compared with the other analytes. EEC plots showed that Rf, Rd, Rc, Rb2 and Rb1 were possibly retained by the same retention mechanism, which was completely different from that of Rg1 and Re at subambient temperatures. Retention prediction models were derived using multiple linear regression to identify solute attributes that affected the retention of the analytes on the PVA-bonded phase. The mathematical models derived revealed that the number of hydrogen-bond donors and the ovality of the molecules are important molecular properties that govern the retention of the compounds on the chromatographic system.
- 1 September 2007
- Published by Taylor & Francis in Journal of Liquid Chromatography & Related Technologies
- Vol. 30 (19) , 2835-2849
Separation of Ginsenosides at Elevated Temperature by Ultra High Pressure Liquid Chromatography
Separation of seven ginsenosides at elevated temperature by ultra high pressure liquid chromatography (UHPLC) on reversed phase C18‐ bonded silica stationary phase was studied. All separations were carried out with a binary mobile phase consisting of CH3CN/H2O in isocratic elution mode. It was found that increasing the column temperature resulted in efficient separation and complete resolution of seven ginsenosides. Generally, the separation efficiency increased as a function of temperature. The effect of the mobile phase velocity on the separation efficiency was also investigated.
- 1 September 2007
- Published by Taylor & Francis in Journal of Liquid Chromatography & Related Technologies
- Vol. 30 (19) , 2835-2849
Separation of Ginsenosides at Elevated Temperature by Ultra High Pressure Liquid Chromatography
Separation of seven ginsenosides at elevated temperature by ultra high pressure liquid chromatography (UHPLC) on reversed phase C18‐ bonded silica stationary phase was studied. All separations were carried out with a binary mobile phase consisting of CH3CN/H2O in isocratic elution mode. It was found that increasing the column temperature resulted in efficient separation and complete resolution of seven ginsenosides. Generally, the separation efficiency increased as a function of temperature. The effect of the mobile phase velocity on the separation efficiency was also investigated.
- 22 June 2007
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 388 (8) , 1693-1706
Retention prediction of adrenoreceptor agonists and antagonists on unmodified silica phase in hydrophilic interaction chromatography
The development of retention prediction models for adrenoreceptor agonists and antagonists chromatographed on an unmodified silica stationary phase under the hydrophilic interaction chromatographic (HILIC) mode at three pH conditions (3.0, 4.0 and 5.0) is described. The models were derived using multiple linear regression (MLR) and an artificial neural network (ANN) using the logarithm of the retention factor (log k) as the dependent variable. In addition to the effects of the solute-related variables (molecular descriptors), the percentage of acetonitrile (%ACN) was also used as a predictor to gauge the influence of the mobile phase on the retention behavior of the analytes. Using stepwise MLR, the retention behavior of the studied compounds at pH 3.0 were satisfactorily described by a four-predictor model; the predictors being the %ACN, the logarithm of the partition coefficient (log D), the number of hydrogen bond acceptors (HBA), and the magnitude of the dipole moment (DipolMag). In addition to these four predictors, the total absolute atomic charge (TAAC) was found to be a significant predictor of retention at pH 4.0 and 5.0. Among the five descriptors, %ACN had the strongest effect on the retention, as indicated by its higher standardized coefficient than those obtained for the other four predictors. The inclusion of these four predictors which are related to the molecular properties of the compounds (log D, HBA, DipolMag, and TAAC) suggested that hydrophilic interactions, hydrogen bonding and ionic interactions are possible mechanisms by which analytes are retained on the studied system. The reliability and predictive ability of the derived MLR equations were tested using cross-validation and a test set which was not used when fitting the model. The models derived from MLR produced adequate fits, as proven by the high R 2 values obtained for all calibration and training sets (0.9497 and above), and their good predictive power, as indicated by the high cross-validated q 2 (0.9465 and above) and high R 2 (0.9305 and above) values obtained for the test sets. ANN prediction models were also derived using the predictors derived from MLR as inputs and log k as output. A comparison of the models derived from both ANN and MLR revealed that the trained ANNs showed better predictive abilities than the MLR models, as indicated by their higher R 2 values and their lower root mean square error of predictions (RMSEP) for both training and test sets under all pH conditions. The derived models can be used as references and they provide a useful tool for method development and the optimization of chromatographic conditions for the separation of adrenoreceptor agonists and antagonists.
- 22 June 2007
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 388 (8) , 1693-1706
Retention prediction of adrenoreceptor agonists and antagonists on unmodified silica phase in hydrophilic interaction chromatography
The development of retention prediction models for adrenoreceptor agonists and antagonists chromatographed on an unmodified silica stationary phase under the hydrophilic interaction chromatographic (HILIC) mode at three pH conditions (3.0, 4.0 and 5.0) is described. The models were derived using multiple linear regression (MLR) and an artificial neural network (ANN) using the logarithm of the retention factor (log k) as the dependent variable. In addition to the effects of the solute-related variables (molecular descriptors), the percentage of acetonitrile (%ACN) was also used as a predictor to gauge the influence of the mobile phase on the retention behavior of the analytes. Using stepwise MLR, the retention behavior of the studied compounds at pH 3.0 were satisfactorily described by a four-predictor model; the predictors being the %ACN, the logarithm of the partition coefficient (log D), the number of hydrogen bond acceptors (HBA), and the magnitude of the dipole moment (DipolMag). In addition to these four predictors, the total absolute atomic charge (TAAC) was found to be a significant predictor of retention at pH 4.0 and 5.0. Among the five descriptors, %ACN had the strongest effect on the retention, as indicated by its higher standardized coefficient than those obtained for the other four predictors. The inclusion of these four predictors which are related to the molecular properties of the compounds (log D, HBA, DipolMag, and TAAC) suggested that hydrophilic interactions, hydrogen bonding and ionic interactions are possible mechanisms by which analytes are retained on the studied system. The reliability and predictive ability of the derived MLR equations were tested using cross-validation and a test set which was not used when fitting the model. The models derived from MLR produced adequate fits, as proven by the high R 2 values obtained for all calibration and training sets (0.9497 and above), and their good predictive power, as indicated by the high cross-validated q 2 (0.9465 and above) and high R 2 (0.9305 and above) values obtained for the test sets. ANN prediction models were also derived using the predictors derived from MLR as inputs and log k as output. A comparison of the models derived from both ANN and MLR revealed that the trained ANNs showed better predictive abilities than the MLR models, as indicated by their higher R 2 values and their lower root mean square error of predictions (RMSEP) for both training and test sets under all pH conditions. The derived models can be used as references and they provide a useful tool for method development and the optimization of chromatographic conditions for the separation of adrenoreceptor agonists and antagonists.