Dario Marani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Dario Marani has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Camilla Maria Braguglia
Water Research Institute (IRSA), National Research Council (CNR), Strada Provinciale 35d, km 0.7, 00010, Montelibretti, Rome, Italy
2 shared publications R. Passino
Water Research Institute, via Reno 1, 00198 Rome, Italy,;
2 shared publications- R. Ramadori
Istituto di Ricerca Sulle Acque C.N.R., Via Reno 1, 00198 Roma, Italy
2 shared publications A. C. Di Pinto
1 shared publication- A.C. DiPinto
Water Research Institute, via Reno 1, 00198 Rome, Italy,;
1 shared publication C.M Braguglia
1 shared publication
Latest Publications
- 1 November 2005
- Published by IWA Publishing in Water Science & Technology
- Vol. 52 (10-11) , 185-192
Rethinking sewage treatment by enhancing primary settling with low-dosage lime
This work presents a thorough fractionation of COD in raw sewage, followed by pilot plant coagulation tests with low-dosage lime (pH 9). Through a physical separation (sieving and crossflow filtration) total COD in the raw sewage was partitioned among eight size fractions in the range of 150–0.02μm. In addition, respirometric tests were performed to measure the biodegradability of the different size fractions. More than 60% of COD was associated with settleable and supracolloidal particles (size >1μm), which are characterised by slow biodegradability. Coagulation with lime increased COD removal efficiencies in the primary treatment from typical 30–35%, up to 65–70%, suggesting that lime may induce the almost complete removal of the slowly settling, slowly biodegradable supracolloidal particles in the primary treatment. On the basis of these results a non-conventional sewage treatment scheme is proposed, considering that there is plenty of space for improving primary treatment efficiency through sewage coagulation. Higher primary treatment efficiency may present several advantages, including lower aeration energy in the subsequent biological unit and higher energy recovery from sludge digestion.
- 1 November 2005
- Published by IWA Publishing in Water Science & Technology
- Vol. 52 (10-11) , 185-192
Rethinking sewage treatment by enhancing primary settling with low-dosage lime
This work presents a thorough fractionation of COD in raw sewage, followed by pilot plant coagulation tests with low-dosage lime (pH 9). Through a physical separation (sieving and crossflow filtration) total COD in the raw sewage was partitioned among eight size fractions in the range of 150–0.02μm. In addition, respirometric tests were performed to measure the biodegradability of the different size fractions. More than 60% of COD was associated with settleable and supracolloidal particles (size >1μm), which are characterised by slow biodegradability. Coagulation with lime increased COD removal efficiencies in the primary treatment from typical 30–35%, up to 65–70%, suggesting that lime may induce the almost complete removal of the slowly settling, slowly biodegradable supracolloidal particles in the primary treatment. On the basis of these results a non-conventional sewage treatment scheme is proposed, considering that there is plenty of space for improving primary treatment efficiency through sewage coagulation. Higher primary treatment efficiency may present several advantages, including lower aeration energy in the subsequent biological unit and higher energy recovery from sludge digestion.
- 1 December 2004
- Published by IWA Publishing in Water Science & Technology
- Vol. 50 (12) , 79-86
Size fractionation of COD in urban wastewater from a combined sewer system
The objective of this work was to determine the partitioning of the pollutant load in urban wastewater in order to improve the conventional sewage treatment. In addition to settling tests, physical fractionation of COD in the degritted influent of Roma-Nord sewage treatment plant was performed via sequential filtration through sieves and membrane filters of the following pore size: 150-100-50-25-1-0.2 μm, and 100 kD (about 0.02 μm). Biodegradability studies were also performed on the different size fractions. Size fractionation showed that COD in Roma-Nord sewage is predominantly associated with settleable and supracolloidal (> 1 μm) particles, each size range including about 40% of total COD. Biodegradability tests indicated that the large fraction of COD associated with supracolloidal particles, which are not removed in the primary treatment, is characterised by slow degradability. This suggests that removal of these particles prior to biological treatment may greatly improve the overall treatment scheme. Preliminary pilot plant coagulation tests with lime at pH 9 showed that lime-enhanced primary treatment may increase COD removal efficiencies from typical 30-35% up to 65-70%, by inducing almost complete removal of the COD fraction associated with supracolloidal particles.
- 1 December 2004
- Published by IWA Publishing in Water Science & Technology
- Vol. 50 (12) , 79-86
Size fractionation of COD in urban wastewater from a combined sewer system
The objective of this work was to determine the partitioning of the pollutant load in urban wastewater in order to improve the conventional sewage treatment. In addition to settling tests, physical fractionation of COD in the degritted influent of Roma-Nord sewage treatment plant was performed via sequential filtration through sieves and membrane filters of the following pore size: 150-100-50-25-1-0.2 μm, and 100 kD (about 0.02 μm). Biodegradability studies were also performed on the different size fractions. Size fractionation showed that COD in Roma-Nord sewage is predominantly associated with settleable and supracolloidal (> 1 μm) particles, each size range including about 40% of total COD. Biodegradability tests indicated that the large fraction of COD associated with supracolloidal particles, which are not removed in the primary treatment, is characterised by slow degradability. This suggests that removal of these particles prior to biological treatment may greatly improve the overall treatment scheme. Preliminary pilot plant coagulation tests with lime at pH 9 showed that lime-enhanced primary treatment may increase COD removal efficiencies from typical 30-35% up to 65-70%, by inducing almost complete removal of the COD fraction associated with supracolloidal particles.
- 27 May 2004
- Published by Wiley in Annali di Chimica
- Vol. 94 (5-6) , 399-408
Improving Primary Treatment of Urban Wastewater with Lime‐Induced Coagulation
The enhancement of primary treatment efficiency through the coagulation process may yield several advantages, including lower aeration energy in the subsequent biological unit and higher recovery of biogas from sludge digestion. In this work sewage coagulation with lime was studied at pilot plant level, using degritted sewage from the city of Rome. The work aimed at optimising the operating conditions (coagulant dosage or treatment pH, and mixing conditions in the coagulation and flocculation tanks), in order to maximise the efficiency of suspended Chemical Oxygen Demand (COD) removal and to minimise sludge production. Lime dosage optimisation resulted in an optimal treatment pH of 9. Lime addition up to pH 9 may increase COD removal rate in the primary treatment from typical 30‐35% of plain sedimentation up to 55‐70%. Within the velocity gradients experimented in this work (314‐795 s‐1 for the coagulation tank and 13‐46 s‐1 for the flocculation tank), mixing conditions did not significantly affect the lime‐enhanced process, which seems to be controlled by slow lime dissolution. Sludge produced in the limeenhanced process settled and compacted easily, inducing an average 36% decrease in sludge volume with respect to plain settling. However excess sludge was produced, which was not accounted for by the amount of suspended solids removed. This is probably due to incomplete dissolution of lime, which may be partially incorporated in the sludge.
- 27 May 2004
- Published by Wiley in Annali di Chimica
- Vol. 94 (5-6) , 399-408
Improving Primary Treatment of Urban Wastewater with Lime‐Induced Coagulation
The enhancement of primary treatment efficiency through the coagulation process may yield several advantages, including lower aeration energy in the subsequent biological unit and higher recovery of biogas from sludge digestion. In this work sewage coagulation with lime was studied at pilot plant level, using degritted sewage from the city of Rome. The work aimed at optimising the operating conditions (coagulant dosage or treatment pH, and mixing conditions in the coagulation and flocculation tanks), in order to maximise the efficiency of suspended Chemical Oxygen Demand (COD) removal and to minimise sludge production. Lime dosage optimisation resulted in an optimal treatment pH of 9. Lime addition up to pH 9 may increase COD removal rate in the primary treatment from typical 30‐35% of plain sedimentation up to 55‐70%. Within the velocity gradients experimented in this work (314‐795 s‐1 for the coagulation tank and 13‐46 s‐1 for the flocculation tank), mixing conditions did not significantly affect the lime‐enhanced process, which seems to be controlled by slow lime dissolution. Sludge produced in the limeenhanced process settled and compacted easily, inducing an average 36% decrease in sludge volume with respect to plain settling. However excess sludge was produced, which was not accounted for by the amount of suspended solids removed. This is probably due to incomplete dissolution of lime, which may be partially incorporated in the sludge.
- 1 January 2003
- Published by Elsevier in Waste Management
- Vol. 23 (2) , 117-124
Behaviour of Cd, Cr, Mn, Ni, Pb, and Zn in sewage sludge incineration by fluidised bed furnace
- 1 January 2003
- Published by Elsevier in Waste Management
- Vol. 23 (2) , 117-124
Behaviour of Cd, Cr, Mn, Ni, Pb, and Zn in sewage sludge incineration by fluidised bed furnace
- 1 April 2000
- Published by IWA Publishing in Water Science & Technology
- Vol. 41 (8) , 61-68
Partitioning of Cr, Cu, Pb and Zn in sewage sludge incineration by rotary kiln and fluidized bed furnaces
The behaviour of four metals (Cr, Cu, Pb, Zn) during sewage sludge incineration was studied in eight pilot plant tests performed with a rotary kiln (RK) and a fluidised bed (FB) furnace. To simulate sludge co-incineration with hazardous wastes, in three FB tests feed sludge was mixed with chlorinated organic compounds. Chromium and copper showed similar concentrations both in bottom or cyclone ash and in fly ash, even at high chlorine input and high combustion temperature. In contrast, zinc and lead concentrations in fly ash produced in RK tests are one or two orders of magnitude higher than those in bottom ash. However, not even these two metals showed significant enrichment in FB tests carried out at high chlorine input. The predictive capability of a thermodynamic model was checked by comparing predicted metal volatilisation in the combustion chamber with experimental metal enrichment in the fly ash. Large discrepancies were observed in FB tests carried out at high chlorine content, where Pb, Zn, and Cu are predicted to volatilise in great extent, andin RK tests where zinc volatilisation is not predicted. Likely explanations of these discrepancies are the very short solid residence times in the FB furnace (non equilibrium conditions) and the incomplete mixing conditions in the RK furnace (pyrolysis pockets). From the environmental impact point of view, the pilot tests suggest that sludge incineration with fluidised bed furnace is safer than the one using rotary kiln furnace.
- 1 April 2000
- Published by IWA Publishing in Water Science & Technology
- Vol. 41 (8) , 61-68
Partitioning of Cr, Cu, Pb and Zn in sewage sludge incineration by rotary kiln and fluidized bed furnaces
The behaviour of four metals (Cr, Cu, Pb, Zn) during sewage sludge incineration was studied in eight pilot plant tests performed with a rotary kiln (RK) and a fluidised bed (FB) furnace. To simulate sludge co-incineration with hazardous wastes, in three FB tests feed sludge was mixed with chlorinated organic compounds. Chromium and copper showed similar concentrations both in bottom or cyclone ash and in fly ash, even at high chlorine input and high combustion temperature. In contrast, zinc and lead concentrations in fly ash produced in RK tests are one or two orders of magnitude higher than those in bottom ash. However, not even these two metals showed significant enrichment in FB tests carried out at high chlorine input. The predictive capability of a thermodynamic model was checked by comparing predicted metal volatilisation in the combustion chamber with experimental metal enrichment in the fly ash. Large discrepancies were observed in FB tests carried out at high chlorine content, where Pb, Zn, and Cu are predicted to volatilise in great extent, andin RK tests where zinc volatilisation is not predicted. Likely explanations of these discrepancies are the very short solid residence times in the FB furnace (non equilibrium conditions) and the incomplete mixing conditions in the RK furnace (pyrolysis pockets). From the environmental impact point of view, the pilot tests suggest that sludge incineration with fluidised bed furnace is safer than the one using rotary kiln furnace.
- 1 February 1997
- Published by Taylor & Francis in Environmental Technology
- Vol. 18 (2) , 225-230
Phosphate Removal from Municipal Wastewater with Low Lime Dosage
The potential use of lime in the pre-treatment of municipal wastewater before the biological process was investigated. The aim of this work was to develop an equilibrium model for predicting optimal treatment conditions to assure satisfactory P removal efficiency and to minimize carbonate precipitation, that causes high lime dosage and excessive sludge production. Model calibration was performed with the results of lime addition tests to actual sewage. The proposed equilibrium model for lime addition to municipal wastewater assumes phosphate and carbonate solubility controlled by metastable Ca4H(PO4)3 and amorphous CaCO3, respectively. Model predictions suggest that lime addition up to pH 9 may assure efficient removal of phosphorus and prevent carbonate precipitation, even in wastewater with high alkalinity content.
- 1 February 1997
- Published by Taylor & Francis in Environmental Technology
- Vol. 18 (2) , 225-230
Phosphate Removal from Municipal Wastewater with Low Lime Dosage
The potential use of lime in the pre-treatment of municipal wastewater before the biological process was investigated. The aim of this work was to develop an equilibrium model for predicting optimal treatment conditions to assure satisfactory P removal efficiency and to minimize carbonate precipitation, that causes high lime dosage and excessive sludge production. Model calibration was performed with the results of lime addition tests to actual sewage. The proposed equilibrium model for lime addition to municipal wastewater assumes phosphate and carbonate solubility controlled by metastable Ca4H(PO4)3 and amorphous CaCO3, respectively. Model predictions suggest that lime addition up to pH 9 may assure efficient removal of phosphorus and prevent carbonate precipitation, even in wastewater with high alkalinity content.
- 1 January 1988
- Published by Elsevier
- p. 109-118
Synthesis and Characterization of Cellulose Xanthate Chelating Exchangers for Heavy Metal Removal and Recovery from Wastewaters
- 1 January 1988
- Published by Elsevier
- p. 109-118
Synthesis and Characterization of Cellulose Xanthate Chelating Exchangers for Heavy Metal Removal and Recovery from Wastewaters