Mohammed Shahid Ali
Research Subjects
Mohammed Shahid Ali has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Mohsin Ghori
Jamjoom Pharmaceuticals Co. Ltd, Industrial Area, Phase-5, PO Box 6267, Jeddah-21442, Saudi Arabia
5 shared publicationsSyed Rafiuddin
Jamjoom Pharmaceuticals Co. Ltd, Industrial Area, Phase-5, PO Box 6267, Jeddah-21442, Saudi Arabia
5 shared publicationsAamer Roshanali Khatri
Jamjoom Pharmaceuticals Company Limited, Jeddah, Saudi Arabia. Fax: +966‐2‐608‐1222
4 shared publicationsAamer Roshanali Kahtri
Jamjoom Pharmaceuticals Co. Ltd, Quality Control, PO Box No. 6267, Jeddah 21442, Saudi Arabia
1 shared publication- Aamer Roshanali Khatri
Jamjoom Pharmaceuticals Co. Ltd
1 shared publication Dalya Abdullah Al‐Jawi
Jamjoom Pharmaceuticals Company Limited, Jeddah, Saudi Arabia. Fax: +966‐2‐608‐1222
1 shared publication
Latest Publications
- Open Access
- 1 September 2008
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 91 (5) , 1025-1036
An Isocratic Reversed-Phase High-Performance Liquid Chromatographic Method for the Simultaneous Determination of Benzoyl Peroxide and the Related Compounds Benzoic Acid, Benzaldehyde, Ethyl Benzoate, Methylparaben, and Propylparaben in Dermal Preparations
A reversed-phase high-performance liquid chromatographic method was developed for the simultaneous determination of benzoyl peroxide and the related compounds benzoic acid (BA), methylparaben, benzaldehyde, propylparaben, and ethyl benzoate. The compounds are separated on a column containing octadecyl silane chemically bonded to porous silica particles. The mobile phase is acetonitrilebuffer (45 + 55, v/v). Solutions are injected into the chromatographic system under isocratic conditions at a constant flow rate of 1.5 mL/min with UV detection at 235 nm. Analysis of stability samples showed rapid accumulation of BA by thermal degradation. A rationale has been established for the acceptable limit of BA in the formulation, which already contains BA (0.2) as a preservative. The proposed method is efficient and determines the active compound and 5 related compounds in a run time of 20 min. The method was validated according to the guidelines of the International Conference on Harmonization and demonstrated good agreement with the validation requirements.
- 1 September 2008
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 91 (5) , 1025-1036
Open AccessAn Isocratic Reversed-Phase High-Performance Liquid Chromatographic Method for the Simultaneous Determination of Benzoyl Peroxide and the Related Compounds Benzoic Acid, Benzaldehyde, Ethyl Benzoate, Methylparaben, and Propylparaben in Dermal Preparations
A reversed-phase high-performance liquid chromatographic method was developed for the simultaneous determination of benzoyl peroxide and the related compounds benzoic acid (BA), methylparaben, benzaldehyde, propylparaben, and ethyl benzoate. The compounds are separated on a column containing octadecyl silane chemically bonded to porous silica particles. The mobile phase is acetonitrilebuffer (45 + 55, v/v). Solutions are injected into the chromatographic system under isocratic conditions at a constant flow rate of 1.5 mL/min with UV detection at 235 nm. Analysis of stability samples showed rapid accumulation of BA by thermal degradation. A rationale has been established for the acceptable limit of BA in the formulation, which already contains BA (0.2) as a preservative. The proposed method is efficient and determines the active compound and 5 related compounds in a run time of 20 min. The method was validated according to the guidelines of the International Conference on Harmonization and demonstrated good agreement with the validation requirements.
- 23 May 2008
- Published by Wiley in Journal of Separation Science
- Vol. 31 (9) , 1645-1650
Stability‐indicating assay of sodium cromoglicate in ophthalmic solution using mixed‐mode hydrophilic interaction chromatography
A hydrophilic interaction chromatographic (HILIC) procedure for the quantification of Sodium Cromoglicate (SCG) in ophthalmic solution is developed. Mobile phase consists of ACN and buffer, 86:14 v/v. Atlantis HILIC–Si column, 25 cm×4.6 mm, is used as stationary phase. Detection is carried out using a variable wavelength UV‐Vis detector at 326 nm. Linearity range and percent recoveries for SCG were 50–400 μg/mL and 100.44%, respectively. The SCG HILIC‐UV assay was validated according to the International Conference on Harmonization guidelines. The method separates two impurities and degradation products resulting from stress environment. Influence of organic solvent, ionic strength and mobile phase pH on the retention of SCG is studied. The paper provides optimization of polar anionic solute (SCG) on unmodified silica by HILIC. Proposed method can be used as a stability‐indicating assay for SGC and can be proved to be beneficial in ESI‐MS for enhanced sensitivity.
- 23 May 2008
- Published by Wiley in Journal of Separation Science
- Vol. 31 (9) , 1645-1650
Stability‐indicating assay of sodium cromoglicate in ophthalmic solution using mixed‐mode hydrophilic interaction chromatography
A hydrophilic interaction chromatographic (HILIC) procedure for the quantification of Sodium Cromoglicate (SCG) in ophthalmic solution is developed. Mobile phase consists of ACN and buffer, 86:14 v/v. Atlantis HILIC–Si column, 25 cm×4.6 mm, is used as stationary phase. Detection is carried out using a variable wavelength UV‐Vis detector at 326 nm. Linearity range and percent recoveries for SCG were 50–400 μg/mL and 100.44%, respectively. The SCG HILIC‐UV assay was validated according to the International Conference on Harmonization guidelines. The method separates two impurities and degradation products resulting from stress environment. Influence of organic solvent, ionic strength and mobile phase pH on the retention of SCG is studied. The paper provides optimization of polar anionic solute (SCG) on unmodified silica by HILIC. Proposed method can be used as a stability‐indicating assay for SGC and can be proved to be beneficial in ESI‐MS for enhanced sensitivity.
- 5 March 2008
- Published by Springer Nature in Chromatographia
- Vol. 67 (7-8) , 517-525
Simultaneous Determination of Metformin Hydrochloride, Cyanoguanidine and Melamine in Tablets by Mixed-Mode HILIC
- 5 March 2008
- Published by Springer Nature in Chromatographia
- Vol. 67 (7-8) , 517-525
Simultaneous Determination of Metformin Hydrochloride, Cyanoguanidine and Melamine in Tablets by Mixed-Mode HILIC
- Open Access
- 1 January 2007
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 90 (1) , 82-93
Simultaneous Determination of Paracetamol, Chlorzoxazone, and Related Impurities 4-Aminophenol, 4'-Chloroacetanilide, and p-Chlorophenol in Pharmaceutical Preparations by High-Performance Liquid Chromatography
This paper presents a simple, specific, and precise high-performance liquid chromatographic method for the simultaneous determination of paracetamol (PCM), chlorzoxazone (CXZ), and their related impurities in bulk raw materials and solid dosage forms. The mobile phase consisted of water methanolglacial acetic acid (60 + 40 2, v/v/v). A column containing octadecylsilane chemically bonded to porous silica particles (Spherisorb ODS 1, 25 cm × 4.6 mm, 5 μm) was used as stationary phase. Detection was performed using a variable wavelength ultraviolet-visible detector set at 272 nm for all compounds. Solutions were injected into the chromatograph under isocratic condition at a constant flow rate of 1.2 mL/min. The method was validated according to International Conference on Harmonization requirements and demonstrates good accuracy and precision and a wide linearity range. The method separates PCM, CXZ, and 3 major impurities 4-aminophenol (4AP), 4'-chloracetanilide (4CA), and p-chlorophenol (PCP) with fair resolution in less than 15 min. The developed method is rapid and sensitive (limit of detection for 4AP, 4CA, and PCP established at 31.25, 39.06, and 65.16 ng/mL, respectively) and, therefore, suitable for quality control and stability studies of these compounds in dosage forms.
- 1 January 2007
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 90 (1) , 82-93
Open AccessSimultaneous Determination of Paracetamol, Chlorzoxazone, and Related Impurities 4-Aminophenol, 4'-Chloroacetanilide, and p-Chlorophenol in Pharmaceutical Preparations by High-Performance Liquid Chromatography
This paper presents a simple, specific, and precise high-performance liquid chromatographic method for the simultaneous determination of paracetamol (PCM), chlorzoxazone (CXZ), and their related impurities in bulk raw materials and solid dosage forms. The mobile phase consisted of water methanolglacial acetic acid (60 + 40 2, v/v/v). A column containing octadecylsilane chemically bonded to porous silica particles (Spherisorb ODS 1, 25 cm × 4.6 mm, 5 μm) was used as stationary phase. Detection was performed using a variable wavelength ultraviolet-visible detector set at 272 nm for all compounds. Solutions were injected into the chromatograph under isocratic condition at a constant flow rate of 1.2 mL/min. The method was validated according to International Conference on Harmonization requirements and demonstrates good accuracy and precision and a wide linearity range. The method separates PCM, CXZ, and 3 major impurities 4-aminophenol (4AP), 4'-chloracetanilide (4CA), and p-chlorophenol (PCP) with fair resolution in less than 15 min. The developed method is rapid and sensitive (limit of detection for 4AP, 4CA, and PCP established at 31.25, 39.06, and 65.16 ng/mL, respectively) and, therefore, suitable for quality control and stability studies of these compounds in dosage forms.
- 1 January 2007
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 43 (1) , 158-167
A new hydrophilic interaction liquid chromatographic (HILIC) procedure for the simultaneous determination of pseudoephedrine hydrochloride (PSH), diphenhydramine hydrochloride (DPH) and dextromethorphan hydrobromide (DXH) in cough-cold formulations
- 1 January 2007
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 43 (1) , 158-167
A new hydrophilic interaction liquid chromatographic (HILIC) procedure for the simultaneous determination of pseudoephedrine hydrochloride (PSH), diphenhydramine hydrochloride (DPH) and dextromethorphan hydrobromide (DXH) in cough-cold formulations