Qiuping Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Qiuping Wang has a total of 71 co-authors. Here are the top co-authors by number of shared publications:
Ning An
National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230026, China
8 shared publicationsXuewei Du
National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230026, China
7 shared publicationsChao-Yang Li
5 shared publicationsChaoyang Li
China Acad Engn Phys, Mianyang 621900, Sichuan, Peoples R China
5 shared publicationsXue-Wei Du
5 shared publicationsLiangliang Du
Univ Sci & Technol China, Dept Precis Machinery & Precis Instrumentat, Hefei 230029, Anhui, Peoples R China
4 shared publications
Latest Publications
- Open Access
Ultrashort X-ray Free Electron Laser Pulse Manipulation by Optical Matrix
Free electron laser (FEL) is capable of producing ultra-short X-ray pulses. The estimation of X-ray pulse propagation is the key process of X-ray FEL beamline design. By using the Kostenbauder matrix approach, the evolution of an ultra-short pulse in a beamline system can be calculated. Therefore, it is of significant importance to investigate the Kostenbauder matrices of different kinds of X-ray optics. In this work, we derive a unified 6 × 6 optical matrix to describe various kinds of X-ray optical elements, including varied-line-spacing (VLS) toroidal grating, VLS spherical grating, VLS cylindrical grating, VLS plane grating, toroidal grating, spherical grating, cylindrical grating, plane grating, toroidal mirror, spherical mirror, cylindrical mirror, and plane mirror. These optics are usually adopted in soft X-ray regime. We apply this method to describe the transverse focusing, pulse front tilt, and pulse stretching after an X-ray pulse going through a VLS plane grating monochromator (VLS-PGM). We also use this approach to simulate a grating compressor which can be used to compress chirped soft X-ray pulse. This work is helpful in the design and optimization of X-ray beamline systems.
Open AccessUltrashort X-ray Free Electron Laser Pulse Manipulation by Optical Matrix
Free electron laser (FEL) is capable of producing ultra-short X-ray pulses. The estimation of X-ray pulse propagation is the key process of X-ray FEL beamline design. By using the Kostenbauder matrix approach, the evolution of an ultra-short pulse in a beamline system can be calculated. Therefore, it is of significant importance to investigate the Kostenbauder matrices of different kinds of X-ray optics. In this work, we derive a unified 6 × 6 optical matrix to describe various kinds of X-ray optical elements, including varied-line-spacing (VLS) toroidal grating, VLS spherical grating, VLS cylindrical grating, VLS plane grating, toroidal grating, spherical grating, cylindrical grating, plane grating, toroidal mirror, spherical mirror, cylindrical mirror, and plane mirror. These optics are usually adopted in soft X-ray regime. We apply this method to describe the transverse focusing, pulse front tilt, and pulse stretching after an X-ray pulse going through a VLS plane grating monochromator (VLS-PGM). We also use this approach to simulate a grating compressor which can be used to compress chirped soft X-ray pulse. This work is helpful in the design and optimization of X-ray beamline systems.
- 9 November 2018
- Published by Springer Nature in Journal of Applied Spectroscopy
- Vol. 85 (5) , 817-822
Composition and Temperature Monitoring of Molten Metal by a Combined LIBS-IR Thermometry System
- 9 November 2018
- Published by Springer Nature in Journal of Applied Spectroscopy
- Vol. 85 (5) , 817-822
Composition and Temperature Monitoring of Molten Metal by a Combined LIBS-IR Thermometry System
- 1 December 2016
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 838, 62-65
Performance of the undulator based ultraviolet and soft x-ray beamline for catalysis and surface science at National Synchrotron Radiation Laboratory
- 1 December 2016
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 838, 62-65
Performance of the undulator based ultraviolet and soft x-ray beamline for catalysis and surface science at National Synchrotron Radiation Laboratory
- Top Cited Papers
- 16 May 2016
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 23 (4) , 1035-1045
The vacuum ultraviolet beamline/endstations at NSRL dedicated to combustion research
An undulator-based vacuum ultraviolet (VUV) beamline (BL03U), intended for combustion chemistry studies, has been constructed at the National Synchrotron Radiation Laboratory (NSRL) in Hefei, China. The beamline is connected to the newly upgraded Hefei Light Source (HLS II), and could deliver photons in the 5–21 eV range, with a photon flux of 1013 photons s−1at 10 eV when the beam current is 300 mA. The monochromator of the beamline is equipped with two gratings (200 lines mm−1and 400 lines mm−1) and its resolving power is 3900 at 7.3 eV for the 200 lines mm−1grating and 4200 at 14.6 eV for the 400 lines mm−1grating. The beamline serves three endstations which are designed for respective studies of premixed flame, fuel pyrolysis in flow reactor, and oxidation in jet-stirred reactor. Each endstation contains a reactor chamber, an ionization chamber where the molecular beam intersects with the VUV light, and a home-made reflectron time-of-flight mass spectrometer. The performance of the beamline and endstations with some preliminary results is presented here. The ability to detect reactive intermediates (e.g.H, O, OH and hydroperoxides) is advantageous in combustion chemistry research.
- 16 May 2016
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 23 (4) , 1035-1045
Top Cited PapersThe vacuum ultraviolet beamline/endstations at NSRL dedicated to combustion research
An undulator-based vacuum ultraviolet (VUV) beamline (BL03U), intended for combustion chemistry studies, has been constructed at the National Synchrotron Radiation Laboratory (NSRL) in Hefei, China. The beamline is connected to the newly upgraded Hefei Light Source (HLS II), and could deliver photons in the 5–21 eV range, with a photon flux of 1013 photons s−1at 10 eV when the beam current is 300 mA. The monochromator of the beamline is equipped with two gratings (200 lines mm−1and 400 lines mm−1) and its resolving power is 3900 at 7.3 eV for the 200 lines mm−1grating and 4200 at 14.6 eV for the 400 lines mm−1grating. The beamline serves three endstations which are designed for respective studies of premixed flame, fuel pyrolysis in flow reactor, and oxidation in jet-stirred reactor. Each endstation contains a reactor chamber, an ionization chamber where the molecular beam intersects with the VUV light, and a home-made reflectron time-of-flight mass spectrometer. The performance of the beamline and endstations with some preliminary results is presented here. The ability to detect reactive intermediates (e.g.H, O, OH and hydroperoxides) is advantageous in combustion chemistry research.
- 12 February 2016
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 70 (4) , 702-708
Quantitative Analysis of Carbon Steel with Multi-Line Internal Standard Calibration Method Using Laser-Induced Breakdown Spectroscopy
A multi-line internal standard calibration method is proposed for the quantitative analysis of carbon steel using laser-induced breakdown spectroscopy (LIBS). A procedure based on the method was adopted to select the best calibration curves and the corresponding emission lines pairs automatically. Laser-induced breakdown spectroscopy experiments with carbon steel samples were performed, and C, Cr, and Mn were analyzed via the proposed method. Calibration curves of these elements were constructed via a traditional single line internal standard calibration method and a multi-line internal standard calibration method. The calibration curves obtained were evaluated with the determination coefficient, the root mean square error of cross-validation, and the average relative error of cross-validation. All of the parameters were improved significantly with the proposed method. The results show that accurate and stable calibration curves can be obtained efficiently via the multi-line internal standard calibration method.
- 12 February 2016
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 70 (4) , 702-708
Quantitative Analysis of Carbon Steel with Multi-Line Internal Standard Calibration Method Using Laser-Induced Breakdown Spectroscopy
A multi-line internal standard calibration method is proposed for the quantitative analysis of carbon steel using laser-induced breakdown spectroscopy (LIBS). A procedure based on the method was adopted to select the best calibration curves and the corresponding emission lines pairs automatically. Laser-induced breakdown spectroscopy experiments with carbon steel samples were performed, and C, Cr, and Mn were analyzed via the proposed method. Calibration curves of these elements were constructed via a traditional single line internal standard calibration method and a multi-line internal standard calibration method. The calibration curves obtained were evaluated with the determination coefficient, the root mean square error of cross-validation, and the average relative error of cross-validation. All of the parameters were improved significantly with the proposed method. The results show that accurate and stable calibration curves can be obtained efficiently via the multi-line internal standard calibration method.
- 1 January 2016
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1741 (1) , 040039
Two-dimensional groove density measurement for gratings by diffraction method
A grating groove density measuring system based on diffraction method has been developed to measure the two-dimensional groove density variations of the VLS gratings at NSRL. The measuring system can provide not only the basic data of the two-dimensional groove density variations for evaluating the imaging properties of grating, but also an important tool for improving the grating manufacturing technology. A commercially available concave grating with a curvature radius of 750 mm was measured to test the accuracy of the measuring system. Results show that the system has a measuring accuracy (ΔN/N) of about 5 × 10−5. Then the groove density variation parameters of the 1200lines/mm VLS plane grating used in NSRL is measured by the system. The groove curvature of the VLS plane grating has been observed.
- 1 January 2016
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1741 (1) , 040039
Two-dimensional groove density measurement for gratings by diffraction method
A grating groove density measuring system based on diffraction method has been developed to measure the two-dimensional groove density variations of the VLS gratings at NSRL. The measuring system can provide not only the basic data of the two-dimensional groove density variations for evaluating the imaging properties of grating, but also an important tool for improving the grating manufacturing technology. A commercially available concave grating with a curvature radius of 750 mm was measured to test the accuracy of the measuring system. Results show that the system has a measuring accuracy (ΔN/N) of about 5 × 10−5. Then the groove density variation parameters of the 1200lines/mm VLS plane grating used in NSRL is measured by the system. The groove curvature of the VLS plane grating has been observed.
- 1 January 2016
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1741 (1) , 030037
Construction and performance of combustion beamline at NSRL
An undulator-based VUV beamline BL03U is constructed at the National Synchrotron Radiation Laboratory. Optical design and performance test results are presented in this paper. The monochromator is a Czerny–Turner configuration with a toroidal collimating mirror, two plane gratings, and a toroidal focusing mirror. Plane gratings with line densities of 200 and 400 l/mm are used to cover the photon energy range of 5–21 eV. A gas absorption spectrum is used to evaluate the beamline performance. The photon energy resolving power (E/ΔE) of the beamline is approximately 3900 at 7.3 eV for the 200 l/mm grating and 4200 at 14.6 eV for the 400 l/mm grating. The photon flux is approximately 5×1012 photons/s/300 mA at energy of 10 eV.
- 1 January 2016
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1741 (1) , 030037
Construction and performance of combustion beamline at NSRL
An undulator-based VUV beamline BL03U is constructed at the National Synchrotron Radiation Laboratory. Optical design and performance test results are presented in this paper. The monochromator is a Czerny–Turner configuration with a toroidal collimating mirror, two plane gratings, and a toroidal focusing mirror. Plane gratings with line densities of 200 and 400 l/mm are used to cover the photon energy range of 5–21 eV. A gas absorption spectrum is used to evaluate the beamline performance. The photon energy resolving power (E/ΔE) of the beamline is approximately 3900 at 7.3 eV for the 200 l/mm grating and 4200 at 14.6 eV for the 400 l/mm grating. The photon flux is approximately 5×1012 photons/s/300 mA at energy of 10 eV.
- 1 June 2015
- Vol. 35 (6) , 1751-5
[Development of a High Spectral Resolution UV Flat-Field Spectrograph].
As an important optical splitting element, grating is used in many different spectrometers and spectrographs. Spherical varied-line-spacing grating (SVLSG) is easily combined with array detectors to get a wide wavelength range of spectrums in one time, because it can focus the spectrums in approximately a plane. Therefore, it's widely used in many spectral instruments. We usually only know the central groove density of a commercial grating and its mounting parameters, while its line spacing parameters are unknown. Moreover, the mounting parameters are optimized within the whole using wavelength range of the grating. However, in most circumstances only part of the wavelength range is used. Therefore, the mounting parameters are not optimized for the needed wavelength range. Under this condition, in this article we developed a method based on the focusing theory of the flat-field grating and the mounting parameters the manufacture provided to deduce the line spacing parameters of the grating. With these parameters, we can optimize the detector position according to the wavelength range we need and ray tracing can be done to test the optical system. In this article we developed a high spectral resolution ultraviolet spectrograph, covering a wavelength range of 230-280 nm. The grating used in this spectrograph has a central groove density of 1 200 lines x mm(-1) and a designed wavelength range of 170-500 nm. We deduced the line spacing parameters of the grating and optimized the detector mounting parameters. Hollow cathode lamps of different elements were used to calibrate the spectrograph and test the spectral resolution of it. Wavelength calibration of the spectrograph has been done with the parameter fitting method, and the calibration accuracy is better than 0.01 nm. Results show the spectral resolution of the spectral graph is about 0.08 nm at 280.20 nm.
- 1 June 2015
- Vol. 35 (6) , 1751-5
[Development of a High Spectral Resolution UV Flat-Field Spectrograph].
As an important optical splitting element, grating is used in many different spectrometers and spectrographs. Spherical varied-line-spacing grating (SVLSG) is easily combined with array detectors to get a wide wavelength range of spectrums in one time, because it can focus the spectrums in approximately a plane. Therefore, it's widely used in many spectral instruments. We usually only know the central groove density of a commercial grating and its mounting parameters, while its line spacing parameters are unknown. Moreover, the mounting parameters are optimized within the whole using wavelength range of the grating. However, in most circumstances only part of the wavelength range is used. Therefore, the mounting parameters are not optimized for the needed wavelength range. Under this condition, in this article we developed a method based on the focusing theory of the flat-field grating and the mounting parameters the manufacture provided to deduce the line spacing parameters of the grating. With these parameters, we can optimize the detector position according to the wavelength range we need and ray tracing can be done to test the optical system. In this article we developed a high spectral resolution ultraviolet spectrograph, covering a wavelength range of 230-280 nm. The grating used in this spectrograph has a central groove density of 1 200 lines x mm(-1) and a designed wavelength range of 170-500 nm. We deduced the line spacing parameters of the grating and optimized the detector mounting parameters. Hollow cathode lamps of different elements were used to calibrate the spectrograph and test the spectral resolution of it. Wavelength calibration of the spectrograph has been done with the parameter fitting method, and the calibration accuracy is better than 0.01 nm. Results show the spectral resolution of the spectral graph is about 0.08 nm at 280.20 nm.
- 1 March 2015
- Published by IOP Publishing in Plasma Science and Technology
- Vol. 17 (3) , 183-187
Impurity Emission Behavior in the Soft X-Ray and Extreme Ultraviolet Range on EAST
- 1 March 2015
- Published by IOP Publishing in Plasma Science and Technology
- Vol. 17 (3) , 183-187
Impurity Emission Behavior in the Soft X-Ray and Extreme Ultraviolet Range on EAST