R. Nageswara Rao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
R. Nageswara Rao has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
D. Nagaraju
HPLC/UV Group, Division of Analytical Chemistry, Discovery Laboratory, Indian Institute of Chemical Technology
3 shared publicationsS. Meena
Medicinal Chemistry Research Division, University College of Pharmaceutical Sience, Kakatiya University
2 shared publications- Syed Naseeruddin Alvi
Indian Institute of Chemical Technology
2 shared publications A. Narasaraju
HPLC/UV Group, Division of Analytical Chemistry, Discovery Laboratory, Indian Institute of Chemical Technology
1 shared publicationA. Raghu Ram Rao
University College of Pharmaceutical Sciences, Kakatiya University, Warangal‐506009, India
1 shared publicationA. Raghuram Rao
Medicinal Chemistry Research Division, University College of Pharmaceutical Sience, Kakatiya University
1 shared publication
Latest Publications
- Open Access
- 12 September 2006
- Published by Springer Nature in Analytical Sciences
- Vol. 22 (9) , 1257-1260
Liquid-Chromatographic Separation and Determination of Process-related Impurities, Including a Regio-Specific Isomer of Celecoxib on Reversed-Phase C18 Column Dynamically Coated with Hexamethyldisilazane
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- 12 September 2006
- Published by Springer Nature in Analytical Sciences
- Vol. 22 (9) , 1257-1260
Open AccessLiquid-Chromatographic Separation and Determination of Process-related Impurities, Including a Regio-Specific Isomer of Celecoxib on Reversed-Phase C18 Column Dynamically Coated with Hexamethyldisilazane
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- Open Access
- 12 February 2006
- Published by Springer Nature in Analytical Sciences
- Vol. 22 (2) , 287-292
Rapid Separation and Determination of Process-Related Substances of Paracetamol Using Reversed-Phase HPLC with Photo Diode Array as a Detector
A simple and rapid gradient reversed-phase high-performance liquid chromatographic method for simultaneous separation and determination of paracetamol and its related compounds in bulk drugs and pharmaceutical formulations has been developed. As many as nine process impurities and one degradation product of paracetamol have been separated on a Symmetry C18 column (4.6 × 250 mm i.d., particle size 5 µm) with gradient elution using 0.01 M potassium dihydrogen phosphate buffer (pH 3.0) and acetonitrile as mobile phase and photo diode array detection at 215 nm. The chromatographic behavior of all the compounds was examined under variable compositions of different solvents, temperatures, buffer concentrations and pH values. The correlation coefficients for calibration curves for paracetamol as well as impurities were in the range of 0.9951 - 0.9994. The proposed RP-LC method was successfully applied to the analysis of commercial formulations; the recoveries of paracetamol were in the range of 99 - 101%. The method could be of use not only for rapid and routine evaluation of the quality of paracetamol in bulk drug manufacturing units but also for detection of its impurities in pharmaceutical formulations.
- 12 February 2006
- Published by Springer Nature in Analytical Sciences
- Vol. 22 (2) , 287-292
Open AccessRapid Separation and Determination of Process-Related Substances of Paracetamol Using Reversed-Phase HPLC with Photo Diode Array as a Detector
A simple and rapid gradient reversed-phase high-performance liquid chromatographic method for simultaneous separation and determination of paracetamol and its related compounds in bulk drugs and pharmaceutical formulations has been developed. As many as nine process impurities and one degradation product of paracetamol have been separated on a Symmetry C18 column (4.6 × 250 mm i.d., particle size 5 µm) with gradient elution using 0.01 M potassium dihydrogen phosphate buffer (pH 3.0) and acetonitrile as mobile phase and photo diode array detection at 215 nm. The chromatographic behavior of all the compounds was examined under variable compositions of different solvents, temperatures, buffer concentrations and pH values. The correlation coefficients for calibration curves for paracetamol as well as impurities were in the range of 0.9951 - 0.9994. The proposed RP-LC method was successfully applied to the analysis of commercial formulations; the recoveries of paracetamol were in the range of 99 - 101%. The method could be of use not only for rapid and routine evaluation of the quality of paracetamol in bulk drug manufacturing units but also for detection of its impurities in pharmaceutical formulations.
- 1 May 2005
- Published by Elsevier in Journal of Chromatography A
- Vol. 1076 (1-2) , 189-192
Preparative isolation and characterization of some minor impurities of astaxanthin by high-performance liquid chromatography
- 1 May 2005
- Published by Elsevier in Journal of Chromatography A
- Vol. 1076 (1-2) , 189-192
Preparative isolation and characterization of some minor impurities of astaxanthin by high-performance liquid chromatography
- 30 December 2004
- Published by Wiley in Biomedical Chromatography
- Vol. 19 (5) , 362-368
Development and validation of a reversed‐phase liquid chromatographic method for separation and simultaneous determination of COX‐2 inhibitors in pharmaceuticals and its application to biological fluids
An isocratic reversed‐phase high‐performance liquid chromatographic method has been developed for separation and simultaneous determination of COX‐2 inhibitors, viz., celecoxib, rofecoxib, valdecoxib, nimesulide and nabumetone, using 4‐chloro‐2‐nitroaniline as internal standard. Good chromatographic separation was achieved using a reversed‐phase Inertsil C18 column with mobile phase consisting of methanol and 0.05% aqueous glacial acetic acid (68:32 v/v) using photodiode array (PDA) detector at 230 nm. It was validated with respect to accuracy, precision, linearity, limit of detection and quantification. The linearity range was found to be 1.0–20 µg/mL and the percentage recoveries were between 97.55 and 100.14. The method is suitable not only for the estimation of active ingredients in pharmaceutical dosage forms but also in vitro estimations in human plasma. It is simple, rapid, selective and capable of detecting and determining COX‐2 inhibitors with a detection limit of 0.127–1.040 µg/mL simultaneously. Copyright © 2004 John Wiley & Sons, Ltd.
- 30 December 2004
- Published by Wiley in Biomedical Chromatography
- Vol. 19 (5) , 362-368
Development and validation of a reversed‐phase liquid chromatographic method for separation and simultaneous determination of COX‐2 inhibitors in pharmaceuticals and its application to biological fluids
An isocratic reversed‐phase high‐performance liquid chromatographic method has been developed for separation and simultaneous determination of COX‐2 inhibitors, viz., celecoxib, rofecoxib, valdecoxib, nimesulide and nabumetone, using 4‐chloro‐2‐nitroaniline as internal standard. Good chromatographic separation was achieved using a reversed‐phase Inertsil C18 column with mobile phase consisting of methanol and 0.05% aqueous glacial acetic acid (68:32 v/v) using photodiode array (PDA) detector at 230 nm. It was validated with respect to accuracy, precision, linearity, limit of detection and quantification. The linearity range was found to be 1.0–20 µg/mL and the percentage recoveries were between 97.55 and 100.14. The method is suitable not only for the estimation of active ingredients in pharmaceutical dosage forms but also in vitro estimations in human plasma. It is simple, rapid, selective and capable of detecting and determining COX‐2 inhibitors with a detection limit of 0.127–1.040 µg/mL simultaneously. Copyright © 2004 John Wiley & Sons, Ltd.
- Open Access
- 11 December 2004
- Published by Springer Nature in Analytical Sciences
- Vol. 20 (12) , 1745-1748
Separation and Determination of Diastereomers of λ-Cyhalothrin by Normal Phase-Liquid Chromatography Using a CN Column
A simple and rapid normal-phase liquid-chromatographic method for the separation and determination of diastereomers of λ-cyhalothrin using a CN column and detection at UV-230 nm has been developed. This method has the advantage of totally resolving each of the diastereomers from impurities, such as meta-phenoxy benzaldehyde, cyhalothric acid and cyhalothric acid chloride, of technical and formulated materials, allowing one to monitor the low-temperature conversion of diastereomers of λ-cyhalothrin for process development.
- 11 December 2004
- Published by Springer Nature in Analytical Sciences
- Vol. 20 (12) , 1745-1748
Open AccessSeparation and Determination of Diastereomers of λ-Cyhalothrin by Normal Phase-Liquid Chromatography Using a CN Column
A simple and rapid normal-phase liquid-chromatographic method for the separation and determination of diastereomers of λ-cyhalothrin using a CN column and detection at UV-230 nm has been developed. This method has the advantage of totally resolving each of the diastereomers from impurities, such as meta-phenoxy benzaldehyde, cyhalothric acid and cyhalothric acid chloride, of technical and formulated materials, allowing one to monitor the low-temperature conversion of diastereomers of λ-cyhalothrin for process development.
- 19 November 2004
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 36 (4) , 759-767
Development and validation of a liquid chromatographic method for determination of related-substances of mosapride citrate in bulk drugs and pharmaceuticals
- 19 November 2004
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 36 (4) , 759-767
Development and validation of a liquid chromatographic method for determination of related-substances of mosapride citrate in bulk drugs and pharmaceuticals