Xing-Zheng Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Xing-Zheng Wu has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Norio Teramae
Department of Chemistry, Graduate School of Science, Tohoku University, Japan
2 shared publicationsSatoshi Terada
Department of Applied Chemistry and Biotechnology, Graduate School of Engineering, University of Fukui, Bunkyo 3-9-1, Fukui-Shi 910-8507, Japan
2 shared publicationsYumiko Tsuji
Department of Materials Science and Engineering, Faculty of Engineering, Fukui University, Bunkyo 3-9-1, Fukui 910-8507, Japan
2 shared publicationsKeiko Akiyama
Department of Materials Science and Engineering, Faculty of Engineering, Fukui University, 3‐9‐1, Bunkyo, Fukui‐shi, 910‐8507, Japan
1 shared publicationKoji Onoda
M&S Techno Systems Inc.,Osaka, Japan
1 shared publicationLuo-Hong Zhang
Department of Materials Scienceand Engineering, Faculty ofEngineering, Fukui University,Fukui, Japan
1 shared publication
Latest Publications
- 28 February 2007
- Published by Elsevier in Reactive and Functional Polymers
- Vol. 67 (2) , 113-119
Optical beam deflection approach for studying ion-exchange reactions occurring at a single ion-exchange resin particle
- 28 February 2007
- Published by Elsevier in Reactive and Functional Polymers
- Vol. 67 (2) , 113-119
Optical beam deflection approach for studying ion-exchange reactions occurring at a single ion-exchange resin particle
- Open Access
- 1 January 2007
- Published by SAGE Publications in Analytical Chemistry Insights
- Vol. 2, 119-124
Hazard Identification on a Single Cell Level Using a Laser Beam
This research shows a novel method for hazard identification of a chemical and UV light on a single cell level with a laser probe beam. The laser probe beam was passed through interface of cell membrane/culture medium of a cultured human hepatoblastoma cell line HepG2. Deflection of the laser probe beam, which was induced by changes in concentration gradients due to the active materials movement across the cell membrane, was monitored. When a toxic hazard existed, a living cell was expected to be killed or injured, or cellular behaviors to be changed greatly. Then, the changing deflection signal from the living cell would become unchanged or altered in a different way. This was successfully demonstrated with cytotoxity of UV light and H2O2. Most of the cultured HepG2 cells showed changing deflection signals after 10 min illumination of UV-visible light longer than 370 nm, while almost all HepG2 cells showed unchanged deflection signal after 10 min illumination of UV-visible light with wavelength longer than 330 nm. The results suggested that UV light between 330-370 nm could kill the cells. Additions of H2O2 solution with different concentrations to the cell cultures caused the changing deflection signal from a living cell either unchanged or changed in different trend, suggesting toxicity of H2O2 to the cells. The results from the beam deflection detection agreed well with those obtained by the conventional trypane blue method.
- 1 January 2007
- Published by SAGE Publications in Analytical Chemistry Insights
- Vol. 2, 119-124
Open AccessHazard Identification on a Single Cell Level Using a Laser Beam
This research shows a novel method for hazard identification of a chemical and UV light on a single cell level with a laser probe beam. The laser probe beam was passed through interface of cell membrane/culture medium of a cultured human hepatoblastoma cell line HepG2. Deflection of the laser probe beam, which was induced by changes in concentration gradients due to the active materials movement across the cell membrane, was monitored. When a toxic hazard existed, a living cell was expected to be killed or injured, or cellular behaviors to be changed greatly. Then, the changing deflection signal from the living cell would become unchanged or altered in a different way. This was successfully demonstrated with cytotoxity of UV light and H2O2. Most of the cultured HepG2 cells showed changing deflection signals after 10 min illumination of UV-visible light longer than 370 nm, while almost all HepG2 cells showed unchanged deflection signal after 10 min illumination of UV-visible light with wavelength longer than 330 nm. The results suggested that UV light between 330-370 nm could kill the cells. Additions of H2O2 solution with different concentrations to the cell cultures caused the changing deflection signal from a living cell either unchanged or changed in different trend, suggesting toxicity of H2O2 to the cells. The results from the beam deflection detection agreed well with those obtained by the conventional trypane blue method.
- 19 May 2005
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 382 (3) , 848-852
In-capillary preconcentration of proteins for capillary electrophoresis using a cellulose acetate-coated porous joint
- 19 May 2005
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 382 (3) , 848-852
In-capillary preconcentration of proteins for capillary electrophoresis using a cellulose acetate-coated porous joint
- 2 February 2005
- Published by Wiley in Electrophoresis
- Vol. 26 (3) , 563-570
Isoelectric focusing sample injection for capillary electrophoresis of proteins
Carrier ampholyte-free isoelectric focusing (IEF) sample injection (concentration) for capillary electrophoresis (CE) is realized in a single capillary. A short section of porous capillary wall was made near the injection end of a capillary by HF etching. In the etching process, an electric voltage was applied across the etching capillary wall and electric current was monitored. When an electric current through the etching capillary was observed, the capillary wall became porous. The etched part was fixed in a vial, where NaOH solution with a certain concentration was added during the sample injection. The whole capillary was filled with pH 3.0 running buffer. The inlet end vial was filled with protein sample dissolved in the running buffer. An electric voltage was applied across the inlet end vial and etched porous wall. A neutralization reaction occurs at the boundary (interface) of the fronts of H+ and OH−. A pH step or sharp pH gradient exists across the boundary. When positive protein ions electromigrate to the boundary from the sample vial, they are isoelectricelly focused at points corresponding to their pH. After a certain period of concentration, a high voltage is applied across the whole capillary and a conventional CE is followed. An over 100-fold concentration factor has been easily obtained for three model proteins (bovine serum albumin, lysozyme, ribonuclease A). Furthermore, the IEF sample concentration and its dynamics have been visually observed with the whole-column imaging technique. Its merits and remaining problem have been discussed, too.
- 2 February 2005
- Published by Wiley in Electrophoresis
- Vol. 26 (3) , 563-570
Isoelectric focusing sample injection for capillary electrophoresis of proteins
Carrier ampholyte-free isoelectric focusing (IEF) sample injection (concentration) for capillary electrophoresis (CE) is realized in a single capillary. A short section of porous capillary wall was made near the injection end of a capillary by HF etching. In the etching process, an electric voltage was applied across the etching capillary wall and electric current was monitored. When an electric current through the etching capillary was observed, the capillary wall became porous. The etched part was fixed in a vial, where NaOH solution with a certain concentration was added during the sample injection. The whole capillary was filled with pH 3.0 running buffer. The inlet end vial was filled with protein sample dissolved in the running buffer. An electric voltage was applied across the inlet end vial and etched porous wall. A neutralization reaction occurs at the boundary (interface) of the fronts of H+ and OH−. A pH step or sharp pH gradient exists across the boundary. When positive protein ions electromigrate to the boundary from the sample vial, they are isoelectricelly focused at points corresponding to their pH. After a certain period of concentration, a high voltage is applied across the whole capillary and a conventional CE is followed. An over 100-fold concentration factor has been easily obtained for three model proteins (bovine serum albumin, lysozyme, ribonuclease A). Furthermore, the IEF sample concentration and its dynamics have been visually observed with the whole-column imaging technique. Its merits and remaining problem have been discussed, too.
- 31 January 2005
- Published by Wiley in Luminescence
- Vol. 20 (1) , 36-40
Chemiluminescence study of active oxygen species produced by TiO2 photocatalytic reaction
Two chemiluminescence approaches have been used for study of active oxygen species produced by the TiO2 photocatalytic reaction. One is based on flow injection analysis (FIA)–luminol chemiluminescence (CL); another is a time‐resolved CL method. In the FIA–CL experiment, an UV‐illuminated TiO2 suspension and water were passed into a mixing cell by two separate flow lines. Luminol solution was injected into the water flow line at different times. The injected luminol reacted with active oxygen species generated by the TiO2 photocatalytic reaction in a mixing coil and produced CL. It was found that the maximum CL was detected at the first injection of luminol. CL intensity decreased with time of injection. When the luminol was injected after 5 min, the CL intensity was almost unchanged. Addition of scavengers of active oxygen species indicated that the CL produced early in the 5 min was caused by O2− and H2O2, while CL after 5 min was only from H2O2. In the time‐resolved CL, the third harmonic wavelength of Nd:YAG laser (355 nm) was used as a UV light source, and CL was detected by a PMT and recorded in a millisecond time scale using a digital oscilloscope. It was found that CL induced by the photocatalytic reaction increased with concentration of the TiO2 suspension. Scavengers of active oxygen species of ·OH, O2− and H2O2 were added to study the involvement of the active oxygen species. Copyright © 2005 John Wiley & Sons, Ltd.
- 31 January 2005
- Published by Wiley in Luminescence
- Vol. 20 (1) , 36-40
Chemiluminescence study of active oxygen species produced by TiO2 photocatalytic reaction
Two chemiluminescence approaches have been used for study of active oxygen species produced by the TiO2 photocatalytic reaction. One is based on flow injection analysis (FIA)–luminol chemiluminescence (CL); another is a time‐resolved CL method. In the FIA–CL experiment, an UV‐illuminated TiO2 suspension and water were passed into a mixing cell by two separate flow lines. Luminol solution was injected into the water flow line at different times. The injected luminol reacted with active oxygen species generated by the TiO2 photocatalytic reaction in a mixing coil and produced CL. It was found that the maximum CL was detected at the first injection of luminol. CL intensity decreased with time of injection. When the luminol was injected after 5 min, the CL intensity was almost unchanged. Addition of scavengers of active oxygen species indicated that the CL produced early in the 5 min was caused by O2− and H2O2, while CL after 5 min was only from H2O2. In the time‐resolved CL, the third harmonic wavelength of Nd:YAG laser (355 nm) was used as a UV light source, and CL was detected by a PMT and recorded in a millisecond time scale using a digital oscilloscope. It was found that CL induced by the photocatalytic reaction increased with concentration of the TiO2 suspension. Scavengers of active oxygen species of ·OH, O2− and H2O2 were added to study the involvement of the active oxygen species. Copyright © 2005 John Wiley & Sons, Ltd.
- 1 January 2005
- Published by Wiley in Biotechnology Progress
- Vol. 21 (6) , 1772-1774
Noninvasive Diagnosis of a Single Cell with a Probe Beam
It is important to distinguish a living/dead cell in cell culture, especially in the regenerate medicine field including cell therapy, since those cells are usually in short supply and consequently the ex vivo culture process should be operated strictly. Conventional methods for distinguishing a living from a dead cell usually require labeling with a dye, which spoils the culture of the cell. Here we show a simple noninvasive method for diagnosing a dead or alive cell with a probe beam. If a cell is alive, the active transport of materials across the cell membrane causes a change of concentration gradients, and this change further induces a change of deflection of a probe beam passing through a vicinity of the cell membrane. If a cell is dead, no or little change in deflection of the probe beam is induced because no or little active materials movement across the cell membrane exists. The deflection of the probe beam is monitored, and judgment on whether a cell is dead or alive from the deflection signal agreed with the conventional decision.
- 1 January 2005
- Published by Wiley in Biotechnology Progress
- Vol. 21 (6) , 1772-1774
Noninvasive Diagnosis of a Single Cell with a Probe Beam
It is important to distinguish a living/dead cell in cell culture, especially in the regenerate medicine field including cell therapy, since those cells are usually in short supply and consequently the ex vivo culture process should be operated strictly. Conventional methods for distinguishing a living from a dead cell usually require labeling with a dye, which spoils the culture of the cell. Here we show a simple noninvasive method for diagnosing a dead or alive cell with a probe beam. If a cell is alive, the active transport of materials across the cell membrane causes a change of concentration gradients, and this change further induces a change of deflection of a probe beam passing through a vicinity of the cell membrane. If a cell is dead, no or little change in deflection of the probe beam is induced because no or little active materials movement across the cell membrane exists. The deflection of the probe beam is monitored, and judgment on whether a cell is dead or alive from the deflection signal agreed with the conventional decision.
- 1 March 1991
- Published by Oxford University Press (OUP) in Bulletin of the Chemical Society of Japan
- Vol. 64 (3) , 755-759
Depth Profiling of Ultra Thin Film Using Laser Induced Fluorescence Spectroscopy under Normal Incidence Conditions Based on the Reciprocal Principle
Depth profiling for thin film sample using laser induced fluorescence spectroscopy under normal incidence conditions, based on the principle of reciprocity, was studied. A laminated Langmuir–Blodgett model film sample (187 nm in thickness) with a concentration depth profile which varies as a stair-like function with 20.8 nm steps was prepared. Using this model film sample, observation angle dependence of fluorescence intensity was compared with theoretical results based on the principle of reciprocity, and it was shown that the principle held for the thin film sample having a continuous concentration depth profile. Secondly, these data were used to reconstruct the concentration depth profile by the least square method. The quantitative concentration depth profiling results obtained for the model film sample were satisfactory. This method can be used for film samples thinner than the wavelength of the excitation light and its spatial resolution in the depth direction is estimated to be in the order of a nanometer.
- 1 March 1991
- Published by Oxford University Press (OUP) in Bulletin of the Chemical Society of Japan
- Vol. 64 (3) , 755-759
Depth Profiling of Ultra Thin Film Using Laser Induced Fluorescence Spectroscopy under Normal Incidence Conditions Based on the Reciprocal Principle
Depth profiling for thin film sample using laser induced fluorescence spectroscopy under normal incidence conditions, based on the principle of reciprocity, was studied. A laminated Langmuir–Blodgett model film sample (187 nm in thickness) with a concentration depth profile which varies as a stair-like function with 20.8 nm steps was prepared. Using this model film sample, observation angle dependence of fluorescence intensity was compared with theoretical results based on the principle of reciprocity, and it was shown that the principle held for the thin film sample having a continuous concentration depth profile. Secondly, these data were used to reconstruct the concentration depth profile by the least square method. The quantitative concentration depth profiling results obtained for the model film sample were satisfactory. This method can be used for film samples thinner than the wavelength of the excitation light and its spatial resolution in the depth direction is estimated to be in the order of a nanometer.