Ronald J. Spiegel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ronald J. Spiegel has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
J.L Preston
Hydrogen Source Corporation, 60 Bidwell Road, South Windsor, CT 06074, USA
2 shared publicationsF. Chamú
Statistics Department, University of North Carolina, Chapel Hill, NC 27599, United States
1 shared publicationJ.C Trocciola
ONSI Corporation, 195 Governors Highway, South Windsor, CT 06704, USA
1 shared publicationJ.L. Preston
1 shared publication- M.R. Leadbetter
Statistics Department, University of North Carolina, Chapel Hill, NC 27599, United States
1 shared publication S.A Thorneloe
National Risk Management Research Laboratory, United States Environmental Protection Agency (EPA), Research Triangle Park, NC 27711, USA
1 shared publication
Latest Publications
- 30 June 2005
- Published by Elsevier in Solar Energy
- Vol. 78 (6) , 717-726
Distributed grid-connected photovoltaic power system emission offset assessment: statistical test of simulated- and measured-based data
- 30 June 2005
- Published by Elsevier in Solar Energy
- Vol. 78 (6) , 717-726
Distributed grid-connected photovoltaic power system emission offset assessment: statistical test of simulated- and measured-based data
- 1 January 2003
- Published by Elsevier in Waste Management
- Vol. 23 (8) , 709-717
Technical assessment of fuel cell operation on anaerobic digester gas at the Yonkers, NY, wastewater treatment plant
- 1 January 2003
- Published by Elsevier in Waste Management
- Vol. 23 (8) , 709-717
Technical assessment of fuel cell operation on anaerobic digester gas at the Yonkers, NY, wastewater treatment plant
- 1 January 2001
- Published by SAGE Publications in Wind Engineering
- Vol. 25 (1) , 23-32
Assessment of a Wind Turbine Intelligent Controller for Enhanced Energy Production and Pollution Reduction
This study assessed the enhanced energy production which is possible when variable-speed wind turbines are electronically controlled by an intelligent controller for efficiency optimization and performance improvement. The control system consists of three fuzzy-logic controllers: a controller to track the turbine generator speed with wind speed to extract maximum output power; a controller to optimize the generator airgap flux for efficiency improvement; and a controller to provide robust speed control against wind gusts and oscillatory torque. The paper describes the control system which has been developed; pertinent laboratory-based results; and an estimate of the enhanced energy production that is possible when the device is installed on a wind turbine. Additionally, the overall enhanced wind energy potential for the USA as a whole is provided if this type of controller is widely installed on turbines in the future. Enhanced pollution offsets are given as based on the increased energy production possible with the controller.
- 1 January 2001
- Published by SAGE Publications in Wind Engineering
- Vol. 25 (1) , 23-32
Assessment of a Wind Turbine Intelligent Controller for Enhanced Energy Production and Pollution Reduction
This study assessed the enhanced energy production which is possible when variable-speed wind turbines are electronically controlled by an intelligent controller for efficiency optimization and performance improvement. The control system consists of three fuzzy-logic controllers: a controller to track the turbine generator speed with wind speed to extract maximum output power; a controller to optimize the generator airgap flux for efficiency improvement; and a controller to provide robust speed control against wind gusts and oscillatory torque. The paper describes the control system which has been developed; pertinent laboratory-based results; and an estimate of the enhanced energy production that is possible when the device is installed on a wind turbine. Additionally, the overall enhanced wind energy potential for the USA as a whole is provided if this type of controller is widely installed on turbines in the future. Enhanced pollution offsets are given as based on the increased energy production possible with the controller.
- 31 October 1999
- Published by Elsevier in Waste Management
- Vol. 19 (6) , 389-399
Fuel cell operation on anaerobic digester gas: conceptual design and assessment
- 31 October 1999
- Published by Elsevier in Waste Management
- Vol. 19 (6) , 389-399
Fuel cell operation on anaerobic digester gas: conceptual design and assessment