Petteri Nieminen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Petteri Nieminen has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- Giovanni Santin
ESA/ESTEC Space Environments and Effects Section, ESTEC, Noordwijk, The Netherlands
6 shared publications - Sebastien Incerti
Université de Bordeaux
5 shared publications - Dimitris Emfietzoglou
University of Ioannina
3 shared publications - Ioanna Kyriakou
University of Ioannina
3 shared publications - Ioannis A. Daglis
Department of Physics, National and Kapodistrian University of Athens, Athens, Greece
3 shared publications - Laurent Desorgher
Institute of Radiation Physics, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
3 shared publications
Latest Publications
- Open Access
- 12 February 2026
- Published by Springer Nature in Space Science Reviews
- Vol. 222 (1) , 19
Correction to: The JUICE Radiation Environment Monitor, RADEM
- 12 February 2026
- Published by Springer Nature in Space Science Reviews
- Vol. 222 (1) , 19
Open AccessCorrection to: The JUICE Radiation Environment Monitor, RADEM
- Open Access
- 6 May 2025
- Published by Springer Nature in Space Science Reviews
- Vol. 221 (4) , 1-48
The JUICE Radiation Environment Monitor, RADEM
The RADiation–hard Electron Monitor (RADEM) is an instrument on board the ESA JUpiter ICy moons Explorer (JUICE) deep-space mission launched on April 14th, 2023. As a part of the Cosmic Vision program, RADEM on JUICE will spend over three years exploring the radiation environment of the Jovian system, including its icy moons Ganymede, Callisto, and Europa. The instrument serves as an on-board radiation monitor, providing nonstop information on particle fluxes and their energy spectra. In addition to being a platform subsystem relevant to spacecraft safety and health, RADEM obtains scientifically valuable data on the radiation environment and extends the particle detection range covered by the JUICE Particle Environment Package (PEP) instrument suite to much higher energies, and broadens the energy coverage in the tens to hundreds of MeV range for electrons and protons, compared to past missions. RADEM consists of three detector subunits: the Electron Detector Head, the Proton & Heavy Ion Detector Head, and the Directional Detector Head. Each of them is connected to a separate readout electronics with a dedicated front-end Application–Specific Integrated Circuit (ASIC) designed especially for the JUICE mission. RADEM measures electrons in the 0.3–40 MeV energy range, protons in the 5–250 MeV energy range, and heavy ions within the Linear Energy Transfer range from 0.1 to 10 MeV cm mg −1 . The Directional Detector provides an angular coverage of incoming radiation up to about 35% of the sky. Being a platform device, the monitor operates and delivers data permanently. Therefore, RADEM measurements also cover the radiation environment of the interplanetary space during the mission cruise phase, including long-term studies of the environment between Venus and Mars as well as the detection of the Solar Energetic Particle events that propagate across different locations in the Solar System.
- 6 May 2025
- Published by Springer Nature in Space Science Reviews
- Vol. 221 (4) , 1-48
Open AccessThe JUICE Radiation Environment Monitor, RADEM
The RADiation–hard Electron Monitor (RADEM) is an instrument on board the ESA JUpiter ICy moons Explorer (JUICE) deep-space mission launched on April 14th, 2023. As a part of the Cosmic Vision program, RADEM on JUICE will spend over three years exploring the radiation environment of the Jovian system, including its icy moons Ganymede, Callisto, and Europa. The instrument serves as an on-board radiation monitor, providing nonstop information on particle fluxes and their energy spectra. In addition to being a platform subsystem relevant to spacecraft safety and health, RADEM obtains scientifically valuable data on the radiation environment and extends the particle detection range covered by the JUICE Particle Environment Package (PEP) instrument suite to much higher energies, and broadens the energy coverage in the tens to hundreds of MeV range for electrons and protons, compared to past missions. RADEM consists of three detector subunits: the Electron Detector Head, the Proton & Heavy Ion Detector Head, and the Directional Detector Head. Each of them is connected to a separate readout electronics with a dedicated front-end Application–Specific Integrated Circuit (ASIC) designed especially for the JUICE mission. RADEM measures electrons in the 0.3–40 MeV energy range, protons in the 5–250 MeV energy range, and heavy ions within the Linear Energy Transfer range from 0.1 to 10 MeV cm mg −1 . The Directional Detector provides an angular coverage of incoming radiation up to about 35% of the sky. Being a platform device, the monitor operates and delivers data permanently. Therefore, RADEM measurements also cover the radiation environment of the interplanetary space during the mission cruise phase, including long-term studies of the environment between Venus and Mars as well as the detection of the Solar Energetic Particle events that propagate across different locations in the Solar System.
- Open Access
- 10 February 2025
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 64 (1) , 117-135
Analytic and Monte Carlo calculations of dose-mean lineal energy for 1 MeV–1 GeV protons with application to radiation protection quality factor
Radiation quality for determining biological effects is commonly linked to the microdosimetric quantity lineal energy ( $$y$$ ) and to the dose-mean lineal energy ( $${y}_{\text{D}}$$ ). Calculations of $${y}_{\text{D}}$$ are typically performed by specialised Monte Carlo track-structure (MCTS) codes, which can be time-intensive. Thus, microdosimetry-based analytic models are potentially useful for practical calculations. Analytic model calculations of proton $${y}_{\text{D}}$$ and radiation protection quality factor ( $$Q$$ ) values in sub-micron liquid water spheres (diameter 10–1000 nm) over a broad energy range (1 MeV–1 GeV) are compared against MCTS simulations by PHITS, RITRACKS, and Geant4-DNA. Additionally, an improved analytic microdosimetry model is proposed. The original analytic model of Xapsos is refined and model parameters are updated based on Geant4-DNA physics model. Direct proton energy deposition is described by an alternative energy-loss straggling distribution and the contribution of secondary electrons is calculated using the dielectric formulation of the relativistic Born approximation. MCTS simulations of proton $${y}_{\text{D}}$$ values using the latest versions of the PHITS, RITRACKS, and Geant4-DNA are reported along with the Monte Carlo Damage Simulation (MCDS) algorithm. The $${y}_{\text{D}}$$ datasets are then used within the Theory of Dual Radiation Action (TDRA) to illustrate variations in $$Q$$ with proton energy. By a careful selection of parameters, overall differences at the ~ 10% level between the proposed analytic model and the MCTS codes can be attained, significantly improving upon existing models. MCDS estimates of $${y}_{\text{D}}$$ are generally much lower than estimates from MCTS simulations. The differences of $$Q$$ among the examined methods are somewhat smaller than those of $${y}_{\text{D}}$$ . Still, estimates of proton $$Q$$ values by the present model are in better agreement with MCTS-based estimates than the existing analytic models. An improved microdosimetry-based analytic model is presented for calculating proton $${y}_{\text{D}}$$ values over a broad range of proton energies (1 MeV–1 GeV) and target sizes (10–1000 nm) in very good agreement with state-of-the-art MCTS simulations. It is envisioned that the proposed model might be used as an alternative to CPU-intensive MCTS simulations and advance practical microdosimetry and quality factor calculations in medical, accelerator, and space radiation applications.- 10 February 2025
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 64 (1) , 117-135
Open AccessAnalytic and Monte Carlo calculations of dose-mean lineal energy for 1 MeV–1 GeV protons with application to radiation protection quality factor
Radiation quality for determining biological effects is commonly linked to the microdosimetric quantity lineal energy ( $$y$$ ) and to the dose-mean lineal energy ( $${y}_{\text{D}}$$ ). Calculations of $${y}_{\text{D}}$$ are typically performed by specialised Monte Carlo track-structure (MCTS) codes, which can be time-intensive. Thus, microdosimetry-based analytic models are potentially useful for practical calculations. Analytic model calculations of proton $${y}_{\text{D}}$$ and radiation protection quality factor ( $$Q$$ ) values in sub-micron liquid water spheres (diameter 10–1000 nm) over a broad energy range (1 MeV–1 GeV) are compared against MCTS simulations by PHITS, RITRACKS, and Geant4-DNA. Additionally, an improved analytic microdosimetry model is proposed. The original analytic model of Xapsos is refined and model parameters are updated based on Geant4-DNA physics model. Direct proton energy deposition is described by an alternative energy-loss straggling distribution and the contribution of secondary electrons is calculated using the dielectric formulation of the relativistic Born approximation. MCTS simulations of proton $${y}_{\text{D}}$$ values using the latest versions of the PHITS, RITRACKS, and Geant4-DNA are reported along with the Monte Carlo Damage Simulation (MCDS) algorithm. The $${y}_{\text{D}}$$ datasets are then used within the Theory of Dual Radiation Action (TDRA) to illustrate variations in $$Q$$ with proton energy. By a careful selection of parameters, overall differences at the ~ 10% level between the proposed analytic model and the MCTS codes can be attained, significantly improving upon existing models. MCDS estimates of $${y}_{\text{D}}$$ are generally much lower than estimates from MCTS simulations. The differences of $$Q$$ among the examined methods are somewhat smaller than those of $${y}_{\text{D}}$$ . Still, estimates of proton $$Q$$ values by the present model are in better agreement with MCTS-based estimates than the existing analytic models. An improved microdosimetry-based analytic model is presented for calculating proton $${y}_{\text{D}}$$ values over a broad range of proton energies (1 MeV–1 GeV) and target sizes (10–1000 nm) in very good agreement with state-of-the-art MCTS simulations. It is envisioned that the proposed model might be used as an alternative to CPU-intensive MCTS simulations and advance practical microdosimetry and quality factor calculations in medical, accelerator, and space radiation applications. - Open Access
- 24 January 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (3) , 1183
Extension of the Discrete Electron Transport Capabilities of the Geant4-DNA Toolkit to MeV Energies
The discrete physics models available in the Geant4-DNA Monte Carlo toolkit are a subject of continuous evolution and improvement in order to meet the needs of state-of-the-art radiobiological research for medical and space applications. The current capabilities of Geant4-DNA for event-by-event electron transport extend up to 1 MeV. In this work, Geant4-DNA’s most accurate electron inelastic model for sub-keV energies is improved and extended up to 10 MeV via the Relativistic Plane Wave Born Approximation and other theoretical considerations. Benchmark simulations of the electronic stopping power and range of electrons in liquid water using the new model show almost excellent agreement (at the few % level) with the recommendations of the International Commission on Radiation Units and Measurements (ICRU) up to 10 MeV, offering notable improvement (by a factor of ~2) over the default Geant4-DNA inelastic model and an order-of-magnitude higher electron limit. The present development will allow Geant4-DNA users to perform electron track-structure simulations up to 10 MeV, thus, covering a wider range of radiotherapeutic applications (including FLASH-RT) as well as space applications involving MeV electrons which are not currently reachable.
- 24 January 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (3) , 1183
Open AccessExtension of the Discrete Electron Transport Capabilities of the Geant4-DNA Toolkit to MeV Energies
The discrete physics models available in the Geant4-DNA Monte Carlo toolkit are a subject of continuous evolution and improvement in order to meet the needs of state-of-the-art radiobiological research for medical and space applications. The current capabilities of Geant4-DNA for event-by-event electron transport extend up to 1 MeV. In this work, Geant4-DNA’s most accurate electron inelastic model for sub-keV energies is improved and extended up to 10 MeV via the Relativistic Plane Wave Born Approximation and other theoretical considerations. Benchmark simulations of the electronic stopping power and range of electrons in liquid water using the new model show almost excellent agreement (at the few % level) with the recommendations of the International Commission on Radiation Units and Measurements (ICRU) up to 10 MeV, offering notable improvement (by a factor of ~2) over the default Geant4-DNA inelastic model and an order-of-magnitude higher electron limit. The present development will allow Geant4-DNA users to perform electron track-structure simulations up to 10 MeV, thus, covering a wider range of radiotherapeutic applications (including FLASH-RT) as well as space applications involving MeV electrons which are not currently reachable.
- Open Access
- 16 April 2023
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 62 (2) , 221-234
Space radiation quality factor for Galactic Cosmic Rays and typical space mission scenarios using a microdosimetric approach
Space radiation exposure from omnipresent Galactic Cosmic Rays (GCRs) in interplanetary space poses a serious carcinogenic risk to astronauts due to the—limited or absent—protective effect of the Earth’s magnetosphere and, in particular, the terrestrial atmosphere. The radiation risk is directly influenced by the quality of the radiation, i.e., its pattern of energy deposition at the micron/DNA scale. For stochastic biological effects, radiation quality is described by the quality factor, $$Q$$ , which can be defined as a function of Linear Energy Transfer (LET) or the microdosimetric lineal energy ( $$y$$ ). In the present work, the average $$Q$$ of GCR for different mission scenarios was calculated using a modified version of the microdosimetric Theory of Dual Radiation Action (TDRA). NASA’s OLTARIS platform was utilized to generate the radiation environment behind different aluminum shielding (0–30 g/cm2) for a typical mission scenario in low-earth orbit (LEO) and in deep space. The microdosimetric lineal energy spectra of ions ( $$Z\ge 1$$ ) in 1 μm liquid water spheres were calculated by a generalized analytical model which considers energy-loss fluctuations and δ-ray transport inside the irradiated medium. The present TDRA-based $$Q$$ -values for the LEO and deep space missions were found to differ by up to 10% and 14% from the corresponding ICRP-based $$Q$$ -values and up to 3% and 6% from NASA’s $$Q$$ -model. In addition, they were found to be in good agreement with the $$Q$$ -values measured in the International Space Station (ISS) and by the Mars Science Laboratory (MSL) Radiation Assessment Detector (RAD) which represent, respectively, a LEO and deep space orbit.- 16 April 2023
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 62 (2) , 221-234
Open AccessSpace radiation quality factor for Galactic Cosmic Rays and typical space mission scenarios using a microdosimetric approach
Space radiation exposure from omnipresent Galactic Cosmic Rays (GCRs) in interplanetary space poses a serious carcinogenic risk to astronauts due to the—limited or absent—protective effect of the Earth’s magnetosphere and, in particular, the terrestrial atmosphere. The radiation risk is directly influenced by the quality of the radiation, i.e., its pattern of energy deposition at the micron/DNA scale. For stochastic biological effects, radiation quality is described by the quality factor, $$Q$$ , which can be defined as a function of Linear Energy Transfer (LET) or the microdosimetric lineal energy ( $$y$$ ). In the present work, the average $$Q$$ of GCR for different mission scenarios was calculated using a modified version of the microdosimetric Theory of Dual Radiation Action (TDRA). NASA’s OLTARIS platform was utilized to generate the radiation environment behind different aluminum shielding (0–30 g/cm2) for a typical mission scenario in low-earth orbit (LEO) and in deep space. The microdosimetric lineal energy spectra of ions ( $$Z\ge 1$$ ) in 1 μm liquid water spheres were calculated by a generalized analytical model which considers energy-loss fluctuations and δ-ray transport inside the irradiated medium. The present TDRA-based $$Q$$ -values for the LEO and deep space missions were found to differ by up to 10% and 14% from the corresponding ICRP-based $$Q$$ -values and up to 3% and 6% from NASA’s $$Q$$ -model. In addition, they were found to be in good agreement with the $$Q$$ -values measured in the International Space Station (ISS) and by the Mars Science Laboratory (MSL) Radiation Assessment Detector (RAD) which represent, respectively, a LEO and deep space orbit. - Open Access
- 4 May 2010
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 514, A21
Using a new set of space-borne particle monitors to investigate solar-terrestrial relations
Context. We investigated the solar origin of Solar Particle Events (SPEs) which occurred during four time periods of the 23rd solar cycle with intense solar activity and were detected by the Standard Radiation Environment Monitor (SREM) onboard the INTEGRAL satellite. SREM is a second generation ESA particle radiation monitor, already flying onboard seven spacecraft.Aims. The present study attempts to establish the association of recorded SPEs by INTEGRAL/SREM with their solar sources and hence evaluate the potential of SREM units as an alarm system for hazardous SPEs.Methods. X-ray, optical and radio data of solar flares and coronal mass ejections (CMEs) that were observed by several space-based instruments during the aforementioned solar cycle were reduced and thoroughly analyzed to establish the corresponding solar origin of the selected SPEs.Results. The analysis produced clear associations with X-class solar flares and respective CMEs for the events of the October–November 2003, January 2005 and December 2006 periods, while for the events that occurred during September 2005, associations with X-class flares are possible but not straightforward due to the complexity of the registered solar particle fluxes.Conclusions. SREM proves to be a new valuable asset for a comprehensive study of SPEs and a useful alert instrument for explosive geoeffective solar events.
- 4 May 2010
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 514, A21
Open AccessUsing a new set of space-borne particle monitors to investigate solar-terrestrial relations
Context. We investigated the solar origin of Solar Particle Events (SPEs) which occurred during four time periods of the 23rd solar cycle with intense solar activity and were detected by the Standard Radiation Environment Monitor (SREM) onboard the INTEGRAL satellite. SREM is a second generation ESA particle radiation monitor, already flying onboard seven spacecraft.Aims. The present study attempts to establish the association of recorded SPEs by INTEGRAL/SREM with their solar sources and hence evaluate the potential of SREM units as an alarm system for hazardous SPEs.Methods. X-ray, optical and radio data of solar flares and coronal mass ejections (CMEs) that were observed by several space-based instruments during the aforementioned solar cycle were reduced and thoroughly analyzed to establish the corresponding solar origin of the selected SPEs.Results. The analysis produced clear associations with X-class solar flares and respective CMEs for the events of the October–November 2003, January 2005 and December 2006 periods, while for the events that occurred during September 2005, associations with X-class flares are possible but not straightforward due to the complexity of the registered solar particle fluxes.Conclusions. SREM proves to be a new valuable asset for a comprehensive study of SPEs and a useful alert instrument for explosive geoeffective solar events.
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2 (10823654) , 796-802
Monte Carlo Simulation of Electromagnetic Interactions of Radiation with Liquid Water in the Framework of the Geant4-DNA Project
A set of processes specialized for the simulation of particle interactions with water has been developed in the Geant4 Low Energy Electromagnetic package. The models cover the interactions of electrons, protons and light ions down to the electronvolt energy scale. They address a physics domain relevant to the simulation of radiation effects in biological systems, where water represents an important component. The software design, the physics models implemented and an overview of their tests are described.
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2 (10823654) , 796-802
Monte Carlo Simulation of Electromagnetic Interactions of Radiation with Liquid Water in the Framework of the Geant4-DNA Project
A set of processes specialized for the simulation of particle interactions with water has been developed in the Geant4 Low Energy Electromagnetic package. The models cover the interactions of electrons, protons and light ions down to the electronvolt energy scale. They address a physics domain relevant to the simulation of radiation effects in biological systems, where water represents an important component. The software design, the physics models implemented and an overview of their tests are described.
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1 (10823654) , 642-647
Geant4 model for the stopping power of low energy negatively charged hadrons
An original model is presented for the simulation of the energy loss of negatively charged hadrons; it calculates the stopping power of these negatively charged particles by regarding the target atoms as an ensemble of quantum harmonic oscillators. Antiproton stopping powers calculated with this model for different elements are shown to be in satisfactory agreement with experimental data.
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1 (10823654) , 642-647
Geant4 model for the stopping power of low energy negatively charged hadrons
An original model is presented for the simulation of the energy loss of negatively charged hadrons; it calculates the stopping power of these negatively charged particles by regarding the target atoms as an ensemble of quantum harmonic oscillators. Antiproton stopping powers calculated with this model for different elements are shown to be in satisfactory agreement with experimental data.
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2 (10823654) , 803-805
Models of biological effects of radiation in the Geant4 Toolkit
A project, named Geant4-DNA, is in progress to extend the Geant4 simulation toolkit to model the effects of radiation with biological systems at cellular and DNA level. The first component implemented in the first development cycle of the project describes the fractional survival of a population of cells irradiated with photons or charged particles. The software system developed provides the user the option to choose among a small set of alternative models for the calculation of mammalian cell survival after irradiation. The flexible design adopted makes the system open to further extension to implement other cell survival models available in literature. The preliminary design of a prototype of the cell survival models implemented and preliminary results in some selected cell lines are described.
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2 (10823654) , 803-805
Models of biological effects of radiation in the Geant4 Toolkit
A project, named Geant4-DNA, is in progress to extend the Geant4 simulation toolkit to model the effects of radiation with biological systems at cellular and DNA level. The first component implemented in the first development cycle of the project describes the fractional survival of a population of cells irradiated with photons or charged particles. The software system developed provides the user the option to choose among a small set of alternative models for the calculation of mammalian cell survival after irradiation. The flexible design adopted makes the system open to further extension to implement other cell survival models available in literature. The preliminary design of a prototype of the cell survival models implemented and preliminary results in some selected cell lines are described.
- 1 September 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2005 8th European Conference on Radiation and Its Effects on Components and Systems
- No. 03796566,p. PH4-1-PH4-4
Monte Carlo Analysis of Effects to Components: New Developments and Trends Enabling Systematic Detailed 3D Studies
Detailed studies of underlying phenomena in radiation interaction with spacecraft devices are enabled by the development of a new Geant4-based application for SEE, degradation and background analyses in 3D geometries with simple user-interfaces.
- 1 September 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2005 8th European Conference on Radiation and Its Effects on Components and Systems
- No. 03796566,p. PH4-1-PH4-4
Monte Carlo Analysis of Effects to Components: New Developments and Trends Enabling Systematic Detailed 3D Studies
Detailed studies of underlying phenomena in radiation interaction with spacecraft devices are enabled by the development of a new Geant4-based application for SEE, degradation and background analyses in 3D geometries with simple user-interfaces.