DGD. Gregoratto

D. Gregoratto

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


D. Gregoratto has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Note on the autocorrelation coefficient as a test statistic for assessment of the goodness-of-fit of biokinetic models to multiple bioassay data sets

    by D. Gregoratto, J. W. Marsh

    The European Commission project IDEAS has produced guidelines for internal dose assessments from monitoring data. A key stage in the guidelines requires assessment of the goodness-of-fit of biokinetic models to bioassay data. The present note extends the use of an autocorrelation coefficient to assess the fits of multiple types of bioassay quantity simultaneously.


  • Particle clearance in the alveolar-interstitial region of the human lungs: model validation

    by D. Gregoratto, M. R. Bailey, J. W. Marsh

    New information on particle retention of inhaled insoluble material indicates that the ICRP Human Respiratory Tract Model (HRTM) significantly underestimates long-term retention in the lungs. In a previous paper, the information from three studies was reviewed, and a model developed to predict particle retention in the lungs of coal miners was adapted in order to obtain parameter values for general use to predict particle retention in the alveolar-interstitial (AI) region. The model is physiologically based and simpler than the HRTM, requiring two instead of three compartments to model the AI region. The main difference from the HRTM AI model is that a significant fraction, about 35 %, of the AI deposit of insoluble material remains sequestered in the interstitium. The new model is here applied to the analysis of two well-known contamination cases with several years of follow-up data.


  • Modelling particle retention in the alveolar–interstitial region of the human lungs

    by D Gregoratto, M R Bailey, J W Marsh

    Better information is available now on long-term particle retention in the human lungs than there was in 1994, when the human respiratory tract model (HRTM) was adopted by the International Commission on Radiological Protection (ICRP). Three recent studies are especially useful because they provide such information for groups of people who inhaled very similar aerosols. For all three the HRTM significantly underestimates lung retention of insoluble material. The purpose of this work was to improve the modelling of long-term retention in the deep lung. A simple physiologically based model developed to predict lung and lymph node particle retention in coal miners was found to represent lung retention in these studies adequately. Instead of the three alveolar-interstitial (AI) compartments in the HRTM, it has an alveolar compartment which clears to the bronchial tree and to a second compartment, representing the interstitium, which clears only to lymph nodes. The main difference from the HRTM AI model is that a significant fraction of the AI deposit is sequestered in the interstitium. To obtain default parameter values for general use, the model was fitted to data from the three recent studies, and also the experimental data used in development of the HRTM to define particle transport from the AI region for the first year after intake. The result of the analysis is that about 40% of the AI deposit of insoluble particles is sequestered in the interstitium and the remaining fraction is cleared to the ciliated airways with a half-time of about 300 days. For some long-lived radionuclides in relatively insoluble form (type S), this increased retention increases the lung dose per unit intake by 50-100% compared to the HRTM value.