WBWilliam M. Bourne

William M. Bourne

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


William M. Bourne has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Corneal Endothelium—Past, Present, and Future

    by William M. Bourne

    To review the history of the growth in knowledge about the corneal endothelium. Publications concerning the corneal endothelium were reviewed. Highpoints in the growth of knowledge about the corneal endothelium include discovery of barrier and pump functions, specular microscopy, reduction in surgical trauma, corneal preservation, and future advances. The highpoints in the history of the growth in knowledge about the corneal endothelium were elucidated.


  • Keratometric Results During the First Year After Keratoplasty: Adjustable Single Running Suture Technique Versus Double Running Suture Technique

    by Manuel Ramirez, David O Hodge, William M Bourne

    * BACKGROUND AND OBJECTIVE: To compare the 3-month and 1-year postoperative keratometric results in a retrospective sequential series of corneal grafts performed with either a double running suture technique or an adjustable single running suture ...


  • Cellular Changes in Transplanted Human Corneas

    by William M. Bourne

    To measure endothelial cell and keratocyte densities in transplanted corneas and the changes in these densities with time. The endothelia of 500 consecutive penetrating corneal transplants were studied longitudinally by specular microscopy for 10 to 20 years. The keratocytes of 36 corneal transplants that varied in postoperative times from 1 month to 20 years were studied cross-sectionally by clinical confocal microscopy. The keratocytes of five transplanted corneas were studied longitudinally by confocal microscopy at 1 day, 1 week, and 1 month postkeratoplasty. Endothelial cell density decreased progressively at an accelerated rate for 20 years after transplantation, with concurrent increases in the coefficient of variation of cell area and corneal thickness and decreases in the percentage of hexagonal cells. Grafts with insufficient endothelial cells developed late endothelial failure, which was the primary cause of graft failure after the first 5 postoperative years. The grafts with late endothelial failure did not lose endothelial cells faster than grafts that did not fail, but instead had fewer cells immediately after transplantation, diminishing to a critically low cell density earlier. The keratocyte density was also decreased in transplanted corneas. Keratocytes became “activated” during the first week after keratoplasty and in grafts with late endothelial failure. It should be possible to prevent or delay late endothelial failure, the primary cause of graft failure, by increasing the number of endothelial cells on transplanted corneas. The status of the keratocytes appears to affect corneal transparency and, thus, visual quality in the grafted eye.


    • 1 November 1999
      • Vol. 40  (12) , 2827-32

    Cell death during corneal storage at 4 degrees C.

    by A Komuro, D O Hodge, G J Gores, W M Bourne

    To evaluate cell death in human donor corneas stored at 4 degrees C, to determine whether terminal deoxynucleotidyl transferase-mediated dUTP-fluorescein nick-end labeling (TUNEL) discriminates between apoptosis and necrosis in corneas stored at 4 degrees C. Ten human corneas were stored in Optisol (Chiron Ophthalmics, Irvine, CA) at 4 degrees C for periods ranging from 0 to 21 days and then fixed for histologic examination. Central corneal sections from each cornea were examined by transmission electron microscopy (TEM) and by the TUNEL assay. Electron micrographs of at least 15 keratocytes each from the anterior, middle, and posterior stroma were examined by three masked observers who graded each cell as normal, apoptotic, or necrotic. Central sections from the same corneas were processed by the TUNEL assay and evaluated with a laser scanning confocal microscope to determine the percentage of apoptotic cells. By TEM, apoptosis occurred in 23% of the keratocytes and necrosis in 12%. By TUNEL assay, apoptosis occurred in 11% of the keratocytes, with the results in individual corneas being similar to the findings by TEM for apoptosis, rather than for necrosis. By TUNEL assay, apoptosis occurred in 13% of the epithelial cells and in 8% of the endothelial cells. The percentage of apoptotic cells and storage time correlated significantly for the epithelium, but not for the keratocytes or endothelium in this small sample. Both apoptosis and necrosis occur in cells during corneal storage at 4 degrees C, with apoptosis appearing to predominate. The TUNEL assay identifies cells undergoing apoptosis, but not necrosis, in corneal tissue. Inhibition of apoptosis in corneas stored at 4 degrees C may prolong acceptable storage times.


    • 1 March 1999
      • Vol. 40  (3) , 603-11

    Estimation of corneal endothelial pump function in long-term contact lens wearers.

    by W M Bourne, D O Hodge, J W McLaren

    To study the effects of long-term contact lens wear on morphologic and physiologic properties of corneal endothelial cells. The endothelial permeability to fluorescein and the rate of corneal deswelling from hypoxia-induced edema were measured in 20 long-term (mean, 17+/-9 years; range, 5-33 years) contact lens wearers and 20 age-matched control subjects. From these data, the relative endothelial pump rate in each subject was estimated, based on the pump-leak hypothesis of corneal hydration control. Corneal autofluorescence and the aqueous humor flow rate were determined by fluorescein fluorophotometry. Images of corneal endothelial cells were recorded by using specular microscopy, and morphologic indices (cell density, coefficient of variation of cell area, percentage of hexagonal cells, and skewness) were determined. No statistically significant differences were found between the contact lens and control groups in endothelial permeability, corneal deswelling, relative endothelial pump rate ([mean +/- SD] 1.07+/-0.33 relative pump units versus 1.01+/-0.25 relative pump units; contact lens versus control; P = 0.57), and endothelial cell density. Contact lens wearers had a significantly higher aqueous humor flow rate (3.57+/-1.03 microl/min versus 2.77+/-0.51 microl/min; P = 0.005), coefficient of variation of cell area (0.35+/-0.09 versus 0.28+/-0.04; P = 0.006), and corneal autofluorescence (3.1+/-0.6 ng/ml versus 2.3+/-0.3 ng/ml fluorescein equivalents; P < 0.001) than did non-contact lens wearers. Despite the known effects of long-term contact lens wear on corneal endothelial morphometry, no effect on endothelial function was found.


    • 1 February 1999
      • Vol. 40  (2) , 320-6

    Automated quantification of keratocyte density by using confocal microscopy in vivo.

    by S V Patel, J W McLaren, J J Camp, L R Nelson, W M Bourne

    To compare keratocyte density determined by using confocal microscopy with keratocyte density determined in the same corneas by histology. Digital en face images of central corneas were recorded three times by using confocal microscopy in vivo in six New Zealand White rabbits. Bright objects (keratocyte nuclei) in the images were automatically identified by using a custom algorithm to estimate total and regional stromal keratocyte densities. The corneas were then excised, fixed, and sectioned in a sagittal plane for histology. Keratocyte nuclei were manually counted from digitized images of 50 histologic sections per cornea. Total and regional keratocyte densities were estimated from the histologic sections by using stereologic methods based on nuclei per unit area, mean nuclear diameter, and section thickness. Histologic cell densities were corrected for tissue shrinkage. By confocal microscopy, total keratocyte density was 39,000 +/- 1,200 cells/mm3 (mean +/- SE; n = 6); cell density was 47,100 +/- 1,300 cells/mm3 in the anterior stroma and decreased to 27,900 +/- 2,700 cells/mm3 in the posterior stroma (P = 0.004). Analysis of the three separate confocal images of each cornea produced repeatable total cell densities (mean coefficient of variation = 0.035). By histology, total keratocyte density was 37,800 +/- 1,100 cells/mm3, not significantly different from that estimated by confocal microscopy (P = 0.43); anterior cell density was 48,300 +/- 900 cells/mm3 and decreased to 29,400 +/- 900 cells/mm3 posteriorly (P < 0.001). Rabbit keratocyte density estimated by automated analysis of confocal microscopy images in vivo is repeatable and agrees with keratocyte density estimated from histologic sections.


  • Morphologic Changes in Corneal Endothelial Cells During 3 Years of Fluorocarbon Contact Lens Wear

    by William M. Bourne, Steven B. Holtan, David O. Hodge

    To record morphologic changes that occur in corneal endothelial cells during daily wear of rigid, gas-permeable fluorocarbon contact lenses during 3 years. Nineteen new wearers and 32 previous wearers were fitted with daily-wear fluorocarbon contact lenses. Photographic images of the central corneal endothelium and central corneal thickness measurements were recorded at baseline, 2 months, and 1, 2, and 3 years after fitting. In the new wearers, an increase in the coefficient of variation of cell area was present by 2 months after lens fitting and increased further over the subsequent 3 years. The increase in coefficient of variation of cell area was correlated with the oxygen transmissibility of the lens. Endothelial cell density was decreased at 2 and 3 years. Corneal thickness did not change. In the previous lens wearers after 3 years, there were no significant changes from baseline in any morphologic value. Corneal thickness was decreased significantly. Although oxygen transmissibility in fluorocarbon contact lenses is improved over previous hard and soft lenses, polymegethism still was induced within 2 months by these lenses, and morphologic changes present from past lens wear did not improve during 3 years of daily wear.


    • 1 January 1998
      • Vol. 39  (1) , 23-9

    Effect of dorzolamide on corneal endothelial function in normal human eyes.

    by C A Egan, D O Hodge, J W McLaren, W M Bourne

    To assess the effects of dorzolamide hydrochloride, a topical carbonic anhydrase inhibitor, on corneal endothelial function. The authors measured the rate of corneal deswelling and the endothelial permeability to fluorescein after 2 hours of hypoxic contact lens wear in 19 normal human subjects. The study was double-masked; one eye of each subject was randomly assigned to receive 2% dorzolamide drops, and the other eye received placebo drops every 8 hours for 24 hours before the study day and twice during the study day. Dorzolamide-treated eyes were not significantly different from placebo-treated eyes in corneal deswelling rate, expressed as the percent recovery per hour (55.7% +/- 13.6% versus 59.6% +/- 14.5%; P > or = 0.10), open eye steady state thickness, swelling induced by hypoxia, and corneal autofluorescence. Endothelial permeability to fluorescein was increased in the dorzolamide eyes (4.40 +/- 0.84 x 10(-4) cm/minute versus 4.10 +/- 0.80 x 10(-4) cm/minute; P = 0.01). As expected, the intraocular pressure and aqueous humor flow rate were decreased in the dorzolamide eyes. Dorzolamide hydrochloride, when topically administered to normal human eyes for 24 hours, had no significant effect on the corneal deswelling rate after hypoxic stress. The corneal endothelial permeability to fluorescein, however, was increased by the drug, although this did not result in increased corneal thickness.


    • 1 March 1997
      • Vol. 38  (3) , 779-82

    Central corneal endothelial cell changes over a ten-year period.

    by W M Bourne, L R Nelson, D O Hodge

    To obtain longitudinal data to estimate long-term morphometric changes in normal human corneal endothelia. Ten years after an initial study, the authors rephotographed the central corneal endothelium of 52 normal subjects with the same contact specular microscope. The findings for the 10 subjects younger than 18 years of age at the initial examination were considered separately. For the remaining 42 adult subjects, the time between examinations averaged 10.6 +/- 0.2 years (range, 10.1 to 11 years). At the recent examination, these subjects' ages averaged 59.5 +/- 16.8 years (range, 30 to 84 years). Outlines of 100 cells for each cornea were digitized. For the 42 adult subjects, the mean endothelial cell density decreased during the 10.6-year interval from 2715 +/- 301 cells/mm2 to 2539 +/- 284 cells/mm2 (P < 0.001). The calculated exponential cell loss rate over this interval was 0.6% +/- 0.5% per year. There was no statistically significant correlation between cell loss rate and age. During the 10.6-year interval, the coefficient of variation of cell area increased from 0.26 +/- 0.05 to 0.29 +/- 0.06 (P < 0.001), and the percentage of hexagonal cells decreased from 67% +/- 8% to 64% +/- 6% (P = 0.003). For the 10 subjects 5 to 15 years of age at the initial examination, the exponential cell loss rate was 1.1% +/- 0.8% per year. Human central endothelial cell density decreases at an average rate of approximately 0.6% per year in normal corneas throughout adult life, with gradual increases in polymegethism and pleomorphism.