Patrick W. Serruys
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Patrick W. Serruys has a total of 219 co-authors. Here are the top co-authors by number of shared publications:
Evelyn Regar
From the Division of Cardiology (K.T., P.W.S., P.C.S., W.J.G., P.F., E.R., M.D., J.M.R.L.), Thoraxcenter, Erasmus MC, Rotterdam, the Netherlands; Department of Cardiology/Angiology (E.G., G.S., M.S., R.M.), Heart Center Siegburg, Siegburg, Germany; Cardialysis BV (C.D., B.B.), Rotterdam, the Netherlands; and Boston Scientific Corporation (M.E.R.), Natick, Mass
6 shared publicationsGlenn Van Langenhove
Department of Interventional Cardiology, Thoraxcenter Bd 418, Dr. Molewaterplein 40, Dijkzigt Hospital, Erasmus University, 3015 GD, Rotterdam, The Netherlands
6 shared publicationsMuzaffer Degertekin
Department of Interventional Cardiology, Thoraxcenter, Erasmus Medical Center, Rotterdam, The Netherlands
6 shared publicationsPim de Feyter
Department of Interventional Cardiology, Thoraxcenter, Erasmus Medical Center, Rotterdam, The Netherlands
5 shared publicationsKengo Tanabe
Division of Cardiology, Thoraxcenter, Erasmus MC, Rotterdam, The Netherlands
4 shared publications- William Wijns
The Lambe Institute for Translational Medicine, The Smart Sensors Laboratory and CURAM, University of Galway, Galway, Ireland
4 shared publications
Latest Publications
- Open Access
Sirolimus eluting stent aborted recurrent distal left main in-stent restenosis involving bifurcation
Left main coronary artery stenosis is associated with dismal prognosis when untreated. Coronary artery bypass grafting (CABG) is the standard treatment. Although stent implantation is increasingly performed for de novo left main lesion, CABG is inevitable if in-stent restenosis (ISR) occurs. Recently, use of sirolimus eluting stents has proved effective in reducing restenosis in …
Open AccessSirolimus eluting stent aborted recurrent distal left main in-stent restenosis involving bifurcation
Left main coronary artery stenosis is associated with dismal prognosis when untreated. Coronary artery bypass grafting (CABG) is the standard treatment. Although stent implantation is increasingly performed for de novo left main lesion, CABG is inevitable if in-stent restenosis (ISR) occurs. Recently, use of sirolimus eluting stents has proved effective in reducing restenosis in …
- 9 September 2003
- Published by Wolters Kluwer Health in Circulation
- Vol. 108 (10) , 69-70
Late-Late Occlusion After Intracoronary Brachytherapy
- 9 September 2003
- Published by Wolters Kluwer Health in Circulation
- Vol. 108 (10) , 69-70
Late-Late Occlusion After Intracoronary Brachytherapy
- 1 September 2003
- Published by Elsevier in The American Journal of Cardiology
- Vol. 92 (6) , 718-720
Impact of different anatomical patterns of left main coronary stenting on long-term survival
- 1 September 2003
- Published by Elsevier in The American Journal of Cardiology
- Vol. 92 (6) , 718-720
Impact of different anatomical patterns of left main coronary stenting on long-term survival
- 12 August 2003
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 60 (1) , 9-17
Sonotherapy, antirestenotic therapeutic ultrasound in coronary arteries: The first clinical experience
- 12 August 2003
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 60 (1) , 9-17
Sonotherapy, antirestenotic therapeutic ultrasound in coronary arteries: The first clinical experience
- Open Access
Acquired coronary artery fistula leading to acute myocardial infarction after endomyocardial biopsy
- 15 February 2003
- Published by Elsevier in The American Journal of Cardiology
- Vol. 91 (4) , 479-481
Usefulness of percutaneous left ventricular assistance to support high-risk percutaneous coronary interventions
- 15 February 2003
- Published by Elsevier in The American Journal of Cardiology
- Vol. 91 (4) , 479-481
Usefulness of percutaneous left ventricular assistance to support high-risk percutaneous coronary interventions
- 4 February 2003
- Published by Wolters Kluwer Health in Circulation
- Vol. 107 (4) , 559-564
TAXUS III Trial
Background—The first clinical study of paclitaxel-eluting stent for de novo lesions showed promising results. We performed the TAXUS III trial to evaluate the feasibility and safety of paclitaxel-eluting stent for the treatment of in-stent restenosis (ISR).Methods and Results—The TAXUS III trial was a single-arm, 2-center study that enrolled 28 patients with ISR meeting the criteria of lesion length ≤30 mm, 50% to 99% diameter stenosis, and vessel diameter 3.0 to 3.5 mm. They were treated with one or more TAXUS NIRx paclitaxel-eluting stents. Twenty-five patients completed the angiographic follow-up at 6 months, and 17 of these underwent intravascular ultrasound (IVUS) examination. No subacute stent thrombosis occurred up to 12 months, but there was one late chronic total occlusion, and additional 3 patients showed angiographic restenosis. The mean late loss was 0.54 mm, with neointimal hyperplasia volume of 20.3 mm3. The major adverse cardiac event rate was 29% (8 patients; 1 non-Q-wave myocardial infarction, 1 coronary artery bypass grafting, and 6 target lesion revascularization [TLR]). Of the patients with TLR, 1 had restenosis in a bare stent implanted for edge dissection and 2 had restenosis in a gap between 2 paclitaxel-eluting stents. Two patients without angiographic restenosis underwent TLR as a result of the IVUS assessment at follow-up (1 incomplete apposition and 1 insufficient expansion of the stent).Conclusions—Paclitaxel-eluting stent implantation is considered safe and potentially efficacious in the treatment of ISR. IVUS guidance to ensure good stent deployment with complete coverage of target lesion may reduce reintervention.
- 4 February 2003
- Published by Wolters Kluwer Health in Circulation
- Vol. 107 (4) , 559-564
TAXUS III Trial
Background—The first clinical study of paclitaxel-eluting stent for de novo lesions showed promising results. We performed the TAXUS III trial to evaluate the feasibility and safety of paclitaxel-eluting stent for the treatment of in-stent restenosis (ISR).Methods and Results—The TAXUS III trial was a single-arm, 2-center study that enrolled 28 patients with ISR meeting the criteria of lesion length ≤30 mm, 50% to 99% diameter stenosis, and vessel diameter 3.0 to 3.5 mm. They were treated with one or more TAXUS NIRx paclitaxel-eluting stents. Twenty-five patients completed the angiographic follow-up at 6 months, and 17 of these underwent intravascular ultrasound (IVUS) examination. No subacute stent thrombosis occurred up to 12 months, but there was one late chronic total occlusion, and additional 3 patients showed angiographic restenosis. The mean late loss was 0.54 mm, with neointimal hyperplasia volume of 20.3 mm3. The major adverse cardiac event rate was 29% (8 patients; 1 non-Q-wave myocardial infarction, 1 coronary artery bypass grafting, and 6 target lesion revascularization [TLR]). Of the patients with TLR, 1 had restenosis in a bare stent implanted for edge dissection and 2 had restenosis in a gap between 2 paclitaxel-eluting stents. Two patients without angiographic restenosis underwent TLR as a result of the IVUS assessment at follow-up (1 incomplete apposition and 1 insufficient expansion of the stent).Conclusions—Paclitaxel-eluting stent implantation is considered safe and potentially efficacious in the treatment of ISR. IVUS guidance to ensure good stent deployment with complete coverage of target lesion may reduce reintervention.
- 8 October 2002
- Published by Wolters Kluwer Health in Circulation
- Vol. 106 (15) , 1949-1956
Angiographic Findings of the Multicenter Randomized Study With the Sirolimus-Eluting Bx Velocity Balloon-Expandable Stent (RAVEL)
Background— Restenosis remains the major limitation of coronary catheter-based intervention. In small vessels, the amount of neointimal tissue is disproportionately greater than the vessel caliber, resulting in higher restenosis rates. In the Randomized Study With the Sirolimus-Eluting Bx Velocity Balloon-Expandable Stent (RAVEL) trial, ≈40% of the vessels were small ( Methods and Results— Patients were randomized to receive either an 18-mm bare metal Bx VELOCITY (BS group, n=118), or a sirolimus-eluting Bx VELOCITY stent (SES group, n=120). Subgroups were stratified into terciles according to their reference diameter (RD; stratum I, RD 2.84 mm). At 6-month follow-up, the restenosis rate in the SES group was 0% in all strata (versus 35%, 26%, and 20%, respectively, in the BS group). In-stent late loss was 0.01±0.25 versus 0.80±0.43 mm in stratum I, 0.01±0.38 versus 0.88±0.57 mm in stratum II, and −0.06±0.35 versus 0.74±0.57 mm in stratum III (SES versus BS). In SES, the minimal lumen diameter (MLD) remained unchanged (Δ −0.72 to 0.72 mm) in 97% of the lesions and increased (=late gain, ΔMLD <−0.72 mm) in 3% of the lesions. Multivariate predictors for late loss were treatment allocation ( P P = 0.008). Conclusions— Sirolimus-eluting stents prevent neointimal proliferation and late lumen loss irrespective of the vessel diameter. The classic inverse relationship between vessel diameter and restenosis rate was seen in the bare stent group but not in the sirolimus-eluting stent group.
- 8 October 2002
- Published by Wolters Kluwer Health in Circulation
- Vol. 106 (15) , 1949-1956
Angiographic Findings of the Multicenter Randomized Study With the Sirolimus-Eluting Bx Velocity Balloon-Expandable Stent (RAVEL)
Background— Restenosis remains the major limitation of coronary catheter-based intervention. In small vessels, the amount of neointimal tissue is disproportionately greater than the vessel caliber, resulting in higher restenosis rates. In the Randomized Study With the Sirolimus-Eluting Bx Velocity Balloon-Expandable Stent (RAVEL) trial, ≈40% of the vessels were small ( Methods and Results— Patients were randomized to receive either an 18-mm bare metal Bx VELOCITY (BS group, n=118), or a sirolimus-eluting Bx VELOCITY stent (SES group, n=120). Subgroups were stratified into terciles according to their reference diameter (RD; stratum I, RD 2.84 mm). At 6-month follow-up, the restenosis rate in the SES group was 0% in all strata (versus 35%, 26%, and 20%, respectively, in the BS group). In-stent late loss was 0.01±0.25 versus 0.80±0.43 mm in stratum I, 0.01±0.38 versus 0.88±0.57 mm in stratum II, and −0.06±0.35 versus 0.74±0.57 mm in stratum III (SES versus BS). In SES, the minimal lumen diameter (MLD) remained unchanged (Δ −0.72 to 0.72 mm) in 97% of the lesions and increased (=late gain, ΔMLD <−0.72 mm) in 3% of the lesions. Multivariate predictors for late loss were treatment allocation ( P P = 0.008). Conclusions— Sirolimus-eluting stents prevent neointimal proliferation and late lumen loss irrespective of the vessel diameter. The classic inverse relationship between vessel diameter and restenosis rate was seen in the bare stent group but not in the sirolimus-eluting stent group.
- 24 September 2002
- Published by Wolters Kluwer Health in Circulation
- Vol. 106 (13) , 1610-1613
Persistent Inhibition of Neointimal Hyperplasia After Sirolimus-Eluting Stent Implantation
Background— Early results of sirolimus-eluting stent implantation showed a nearly complete abolition of neointimal hyperplasia. The question remains, however, whether the early promising results will still be evident at long-term follow-up. The objective of our study was to evaluate the efficiency of sirolimus-eluting stent implantation for up to 2 years of follow-up. Methods and Results— Fifteen patients with de novo coronary artery disease were treated with 18-mm sirolimus-eluting Bx-Velocity stents (Cordis) loaded with 140 μg sirolimus/cm 2 metal surface area in a slow release formulation. Quantitative angiography (QCA) and intravascular ultrasound (IVUS) were performed according to standard protocol. Sirolimus-eluting stent implantation was successful in all 15 patients. During the in-hospital course, 1 patient died of cerebral hemorrhage after periprocedural administration of abciximab, and 1 patient underwent repeat stenting after 2 hours because of edge dissection that led to acute occlusion. Through 6 months and up to 2 years of follow-up, no additional events occurred. QCA analysis revealed no significant change in stent minimal lumen diameter or percent diameter stenosis, and 3-dimensional IVUS showed no significant deterioration in lumen volume. In 2 patients, additional stenting was performed because of significant lesion progression remote from the sirolimus-eluting stent. Conclusion— Sirolimus-eluting stents showed persistent inhibition of neointimal hyperplasia for up to 2 years of follow-up.
- 24 September 2002
- Published by Wolters Kluwer Health in Circulation
- Vol. 106 (13) , 1610-1613
Persistent Inhibition of Neointimal Hyperplasia After Sirolimus-Eluting Stent Implantation
Background— Early results of sirolimus-eluting stent implantation showed a nearly complete abolition of neointimal hyperplasia. The question remains, however, whether the early promising results will still be evident at long-term follow-up. The objective of our study was to evaluate the efficiency of sirolimus-eluting stent implantation for up to 2 years of follow-up. Methods and Results— Fifteen patients with de novo coronary artery disease were treated with 18-mm sirolimus-eluting Bx-Velocity stents (Cordis) loaded with 140 μg sirolimus/cm 2 metal surface area in a slow release formulation. Quantitative angiography (QCA) and intravascular ultrasound (IVUS) were performed according to standard protocol. Sirolimus-eluting stent implantation was successful in all 15 patients. During the in-hospital course, 1 patient died of cerebral hemorrhage after periprocedural administration of abciximab, and 1 patient underwent repeat stenting after 2 hours because of edge dissection that led to acute occlusion. Through 6 months and up to 2 years of follow-up, no additional events occurred. QCA analysis revealed no significant change in stent minimal lumen diameter or percent diameter stenosis, and 3-dimensional IVUS showed no significant deterioration in lumen volume. In 2 patients, additional stenting was performed because of significant lesion progression remote from the sirolimus-eluting stent. Conclusion— Sirolimus-eluting stents showed persistent inhibition of neointimal hyperplasia for up to 2 years of follow-up.
- 13 August 2002
- Published by Wolters Kluwer Health in Circulation
- Vol. 106 (7) , 798-803
Intravascular Ultrasound Findings in the Multicenter, Randomized, Double-Blind RAVEL (RAndomized study with the sirolimus-eluting VElocity balloon-expandable stent in the treatment of patients with de novo native coronary artery Lesions) Trial
Background—The goal of this intravascular ultrasound investigation was to provide a more detailed morphological analysis of the local biological effects of the implantation of a sirolimus-eluting stent compared with an uncoated stent.Methods and Results—In the RAVEL trial, 238 patients with single de novo lesions were randomized to receive either an 18-mm sirolimus-eluting stent (Bx VELOCITY stent, Cordis) or an uncoated stent (Bx VELOCITY stent). In a subset of 95 patients (sirolimus-eluting stent=48, uncoated stent=47), motorized intravascular ultrasound pullback (0.5 mm/s) was performed at a 6-month follow-up. Stent volumes, total vessel volumes, and plaque-behind-stent volumes were comparable. However, the difference in neointimal hyperplasia (2±5 versus 37±28 mm3) and percent of volume obstruction (1±3% versus 29±20%) at 6 months between the 2 groups was highly significant (PPConclusions—Sirolimus-eluting stents are effective in preventing neointimal hyperplasia without creating edge effect and without affecting the plaque burden behind the struts.
- 13 August 2002
- Published by Wolters Kluwer Health in Circulation
- Vol. 106 (7) , 798-803
Intravascular Ultrasound Findings in the Multicenter, Randomized, Double-Blind RAVEL (RAndomized study with the sirolimus-eluting VElocity balloon-expandable stent in the treatment of patients with de novo native coronary artery Lesions) Trial
Background—The goal of this intravascular ultrasound investigation was to provide a more detailed morphological analysis of the local biological effects of the implantation of a sirolimus-eluting stent compared with an uncoated stent.Methods and Results—In the RAVEL trial, 238 patients with single de novo lesions were randomized to receive either an 18-mm sirolimus-eluting stent (Bx VELOCITY stent, Cordis) or an uncoated stent (Bx VELOCITY stent). In a subset of 95 patients (sirolimus-eluting stent=48, uncoated stent=47), motorized intravascular ultrasound pullback (0.5 mm/s) was performed at a 6-month follow-up. Stent volumes, total vessel volumes, and plaque-behind-stent volumes were comparable. However, the difference in neointimal hyperplasia (2±5 versus 37±28 mm3) and percent of volume obstruction (1±3% versus 29±20%) at 6 months between the 2 groups was highly significant (PPConclusions—Sirolimus-eluting stents are effective in preventing neointimal hyperplasia without creating edge effect and without affecting the plaque burden behind the struts.