Paule M. Charland
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Paule M. Charland has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- L. D. Paniak
4pi Solutions, Inc., Kitchener Ontario N2N 3N3, Canada
2 shared publications Alex F. Bielajew
1 shared publicationBenedick A. Fraass
1 shared publication- Benedick A. Fraass
Department of Radiation Oncology, University of Michigan Medical Center, Ann Arbor, MI 48109-5010, USA
1 shared publication Bryan P. Bednarz
1 shared publication- Daniel L. McShan
Dept. of Radiation Oncology The University of Michigan 48103 Ann Arbor MI
1 shared publication
Latest Publications
- Open Access
- 8 May 2015
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 16 (3) , 99-106
Assessment of Eclipse electron Monte Carlo output prediction for various topologies
Monte Carlo simulation is deemed to be the leading algorithm for accurate dose calculation with electron beams. Patient anatomy (contours and tissue densities) as well as irradiation geometry is accounted for. The accuracy of the Monitor Unit (MU) determination is one essential aspect of a treatment planning system. Patient-specific quality assurance of a Monte Carlo plan usually involves verification of the MUs with an independent simpler calculation approach, in which flat geometry is to be assumed. The magnitude of the discrepancies between flat and varied surfaces for a few scenarios has been investigated in this study. The ability to predict MUs for various surface topologies by the commercial electron Monte Carlo implementation from Varian Eclipse system (Eclipse eMC) has been evaluated and compared to the Generalized Gaussian Pencil Beam (GGPB) algorithm. Ten phantoms with different topologies were constructed of water-equivalent material. Measurements with a parallel plate ionization chamber were performed using these phantoms to gauge their relative impact on outputs for 6, 9, 12, 16, and 20 MeV electron beams from a Varian TrueBeam with cone sizes ranging from to . The corresponding Monte Carlo simulations of the measured geometries were carried out using the CT scans of these phantoms. The results indicated that the Eclipse eMC algorithm can predict these output changes within 3% for most scenarios. However, at the lowest energy, the discrepancy was the greatest, up to 6%. In comparison, the Eclipse GGPB algorithm had much worse agreement, with discrepancies up to 17% at the lowest energies. PACS numbers: 87.55.K-, 87.55.km- 8 May 2015
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 16 (3) , 99-106
Open AccessAssessment of Eclipse electron Monte Carlo output prediction for various topologies
Monte Carlo simulation is deemed to be the leading algorithm for accurate dose calculation with electron beams. Patient anatomy (contours and tissue densities) as well as irradiation geometry is accounted for. The accuracy of the Monitor Unit (MU) determination is one essential aspect of a treatment planning system. Patient-specific quality assurance of a Monte Carlo plan usually involves verification of the MUs with an independent simpler calculation approach, in which flat geometry is to be assumed. The magnitude of the discrepancies between flat and varied surfaces for a few scenarios has been investigated in this study. The ability to predict MUs for various surface topologies by the commercial electron Monte Carlo implementation from Varian Eclipse system (Eclipse eMC) has been evaluated and compared to the Generalized Gaussian Pencil Beam (GGPB) algorithm. Ten phantoms with different topologies were constructed of water-equivalent material. Measurements with a parallel plate ionization chamber were performed using these phantoms to gauge their relative impact on outputs for 6, 9, 12, 16, and 20 MeV electron beams from a Varian TrueBeam with cone sizes ranging from to . The corresponding Monte Carlo simulations of the measured geometries were carried out using the CT scans of these phantoms. The results indicated that the Eclipse eMC algorithm can predict these output changes within 3% for most scenarios. However, at the lowest energy, the discrepancy was the greatest, up to 6%. In comparison, the Eclipse GGPB algorithm had much worse agreement, with discrepancies up to 17% at the lowest energies. PACS numbers: 87.55.K-, 87.55.km - 14 October 2008
- Published by Wiley in Medical Physics
- Vol. 35 (11) , 4967-4973
The Jacobian as a measure of planar dose congruence
We propose a new starting point for comparing planar dose distributions using a Jacobian‐based measure. The measure is normalization independent, i.e., is sensitive to dose patterns while not being biased by global dose scaling. The measure is free of tunable parameters and is bounded between zero and one. We also propose an integrated version of the measure, normalized over the integrated area: the Jacobian index. We demonstrate analytically and verified numerically that the Jacobian index tends to a unique value of when comparing unrelated dose distributions. We present a preliminary demonstration of the sensitivity and general characteristics of this measure. Examples of intensity modulated photon dose distributions from a linac as predicted with the convolution‐superposition algorithm for various scenarios of irradiation mismatch and a film measured distribution are compared.
- 14 October 2008
- Published by Wiley in Medical Physics
- Vol. 35 (11) , 4967-4973
The Jacobian as a measure of planar dose congruence
We propose a new starting point for comparing planar dose distributions using a Jacobian‐based measure. The measure is normalization independent, i.e., is sensitive to dose patterns while not being biased by global dose scaling. The measure is free of tunable parameters and is bounded between zero and one. We also propose an integrated version of the measure, normalized over the integrated area: the Jacobian index. We demonstrate analytically and verified numerically that the Jacobian index tends to a unique value of when comparing unrelated dose distributions. We present a preliminary demonstration of the sensitivity and general characteristics of this measure. Examples of intensity modulated photon dose distributions from a linac as predicted with the convolution‐superposition algorithm for various scenarios of irradiation mismatch and a film measured distribution are compared.
- Open Access
The Jacobian as a measure of planar dose congruence
We propose a new starting point for comparing dose distributions in therapeutic radiation physics using a Jacobian-based measure. The measure is normalization independent, free of tunable parameters, bounded and converges to a unique value when comparing unrelated dose distributions. We present a preliminary demonstration of the sensitivity and general characteristics of this measure.
Open AccessThe Jacobian as a measure of planar dose congruence
We propose a new starting point for comparing dose distributions in therapeutic radiation physics using a Jacobian-based measure. The measure is normalization independent, free of tunable parameters, bounded and converges to a unique value when comparing unrelated dose distributions. We present a preliminary demonstration of the sensitivity and general characteristics of this measure.
- 23 January 2004
- Published by Wiley in Medical Physics
- Vol. 31 (2) , 264-276
Enhanced spectral discrimination through the exploitation of interface effects in photon dose data
The convolution/superposition algorithm for computing dose from photon beams in radiation therapy planning requires knowledge of the energy spectrum. The algorithm can compute the dose for a polyenergetic beam as the weighted sum of the individual dose contributions from monoenergetic beams. In this study we exploit interface effects apparent in the dose distributions to discriminate among spectra of high energy photon beams. We have studied the sensitivity of the depth dose distribution to the energy components using a hypothetical beam for various field sizes and depths in water and water-lung-water media. Six theoretical spectra were simulated. We compared depth dose data from these spectra using three quantitative measures which are inherently free of normalization ambiguities: for homogeneous water, the ratio D20/D10 and a logarithmic derivative in the buildup region LD(build-up) and for inhomogeneous lung/water, the lung correction factor (CF). It was found that the ability of both the CF and the LD(build-up) tests to discriminate between the various theoretical spectra were superior to that of the D20/D10 test. This discriminating power of the CF test decreases with increasing field size due to restored electronic equilibrium. The CF test, though, has some advantages over the LD(build-up) test since it is less prone to electron contamination issues and numerical errors. A practical example with a 15 MV photon beam illustrates the process. Consequently, we suggest that as part of a beam-commissioning methodology, designated electronic disequilibrium test cases be implemented in unambiguously determining the correct energy spectrum to be used.
- 23 January 2004
- Published by Wiley in Medical Physics
- Vol. 31 (2) , 264-276
Enhanced spectral discrimination through the exploitation of interface effects in photon dose data
The convolution/superposition algorithm for computing dose from photon beams in radiation therapy planning requires knowledge of the energy spectrum. The algorithm can compute the dose for a polyenergetic beam as the weighted sum of the individual dose contributions from monoenergetic beams. In this study we exploit interface effects apparent in the dose distributions to discriminate among spectra of high energy photon beams. We have studied the sensitivity of the depth dose distribution to the energy components using a hypothetical beam for various field sizes and depths in water and water-lung-water media. Six theoretical spectra were simulated. We compared depth dose data from these spectra using three quantitative measures which are inherently free of normalization ambiguities: for homogeneous water, the ratio D20/D10 and a logarithmic derivative in the buildup region LD(build-up) and for inhomogeneous lung/water, the lung correction factor (CF). It was found that the ability of both the CF and the LD(build-up) tests to discriminate between the various theoretical spectra were superior to that of the D20/D10 test. This discriminating power of the CF test decreases with increasing field size due to restored electronic equilibrium. The CF test, though, has some advantages over the LD(build-up) test since it is less prone to electron contamination issues and numerical errors. A practical example with a 15 MV photon beam illustrates the process. Consequently, we suggest that as part of a beam-commissioning methodology, designated electronic disequilibrium test cases be implemented in unambiguously determining the correct energy spectrum to be used.
- 25 March 2003
- Published by Wiley in Medical Physics
- Vol. 30 (4) , 563-573
Photon beam relative dose validation of the DPM Monte Carlo code in lung‐equivalent media
Validation experiments have been conducted using 6 and 15 MV photons in inhomogeneous (water/lung/water) media to benchmark the accuracy of the DPM Monte Carlo code for photon beam dose calculations. Small field sizes (down to 2 x 2 cm2) and low-density media were chosen for this investigation because the intent was to test the DPM code under conditions where lateral electronic disequilibrium effects are emphasized. The treatment head components of a Varian 21EX linear accelerator, including the jaws (defining field sizes of 2 x 2, 3 x 3 and 10 x 10 cm2), were simulated using the BEAMnrc code. The phase space files were integrated within the DPM code system, and central axis depth dose and profile calculations were compared against diode measurements in a homogeneous water phantom in order to validate the phase space. Results of the homogeneous phantom study indicated that the relative differences between DPM calculations and measurements were within +/- 1% (based on the rms deviation) for the depth dose curves; relative profile dose differences were on average within +/- 1%/1 mm. Depth dose and profile measurements were carried out using an ion-chamber and film, within an inhomogeneous phantom consisting of a 6 cm slab of lung-equivalent material embedded within solid water. For the inhomogeneous phantom experiment, DPM depth dose calculations were within +/- 1% (based on the rms deviation) of measurements; relative profile differences at depths within and beyond the lung were, on average, within +/- 2% in the inner and outer beam regions, and within 1-2 mm distance-to-agreement within the penumbral region. Relative point differences on the order of 2-3% were within the estimated experimental uncertainties. This work demonstrates that the DPM Monte Carlo code is capable of accurate photon beam dose calculations in situations where lateral electron disequilibrium effects are pronounced.
- 25 March 2003
- Published by Wiley in Medical Physics
- Vol. 30 (4) , 563-573
Photon beam relative dose validation of the DPM Monte Carlo code in lung‐equivalent media
Validation experiments have been conducted using 6 and 15 MV photons in inhomogeneous (water/lung/water) media to benchmark the accuracy of the DPM Monte Carlo code for photon beam dose calculations. Small field sizes (down to 2 x 2 cm2) and low-density media were chosen for this investigation because the intent was to test the DPM code under conditions where lateral electronic disequilibrium effects are emphasized. The treatment head components of a Varian 21EX linear accelerator, including the jaws (defining field sizes of 2 x 2, 3 x 3 and 10 x 10 cm2), were simulated using the BEAMnrc code. The phase space files were integrated within the DPM code system, and central axis depth dose and profile calculations were compared against diode measurements in a homogeneous water phantom in order to validate the phase space. Results of the homogeneous phantom study indicated that the relative differences between DPM calculations and measurements were within +/- 1% (based on the rms deviation) for the depth dose curves; relative profile dose differences were on average within +/- 1%/1 mm. Depth dose and profile measurements were carried out using an ion-chamber and film, within an inhomogeneous phantom consisting of a 6 cm slab of lung-equivalent material embedded within solid water. For the inhomogeneous phantom experiment, DPM depth dose calculations were within +/- 1% (based on the rms deviation) of measurements; relative profile differences at depths within and beyond the lung were, on average, within +/- 2% in the inner and outer beam regions, and within 1-2 mm distance-to-agreement within the penumbral region. Relative point differences on the order of 2-3% were within the estimated experimental uncertainties. This work demonstrates that the DPM Monte Carlo code is capable of accurate photon beam dose calculations in situations where lateral electron disequilibrium effects are pronounced.