Wybe J. M. van der Kemp
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wybe J. M. van der Kemp has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Vincent Oltman Boer
Centre for Functional and Diagnostic Imaging and Research Danish Research Centre for Magnetic Resonance Copenhagen University Hospital -Amager and Hvidovre Kettegård Allé 30 2650 Hvidovre Denmark
6 shared publications Peter R. Luijten
Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands
4 shared publications- Bertine L. Stehouwer
Department of Radiology and Nuclear Medicine, University Medical Centre Utrecht, P.O. Box 85500, 3508 GA Utrecht, The Netherlands
3 shared publications D. W. J. Klomp
Department of Radiology University Medical Center Utrecht PO Box 85500 3508 GA Utrecht The Netherlands
3 shared publications- Dennis W. J. Klomp
Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands
3 shared publications Dennis W.J. Klomp
Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands
3 shared publications
Latest Publications
- Open Access
- 12 October 2018
- Published by Wiley in NMR in Biomedicine
- Vol. 32 (10) , e4011
Shortening of apparent transverse relaxation time of inorganic phosphate as a breast cancer biomarker
Phosphorus MRS offers a non‐invasive tool for monitoring cell energy and phospholipid metabolism and can be of additional value in diagnosing cancer and monitoring cancer therapy. In this study, we determined the transverse relaxation times of a number of phosphorous metabolites in a group of breast cancer patients by adiabatic multi‐echo spectroscopic imaging at 7 T. The transverse relaxation times of phosphoethanolamine, phosphocholine, inorganic phosphate (Pi), glycerophosphocholine and glycerophosphatidylcholine were 184 ± 8 ms, 203 ± 17 ms, 87 ± 8 ms, 240 ± 56 ms and 20 ± 10 ms, respectively. The transverse relaxation time of Pi in breast cancer tissue was less than half that of healthy fibroglandular tissue. This effect is most likely caused by an up‐regulation of glycolysis in breast cancer tissue that leads to interaction of Pi with the GAPDH enzyme, which forms part of the reversible pathway of exchange of Pi with gamma‐adenosine tri‐phosphate, thus shortening its apparent transverse relaxation time. As healthy breast tissue shows very little glycolytic activity, the apparent T2 shortening of Pi due to malignant transformation could possibly be used as a biomarker for cancer.
- 12 October 2018
- Published by Wiley in NMR in Biomedicine
- Vol. 32 (10) , e4011
Open AccessShortening of apparent transverse relaxation time of inorganic phosphate as a breast cancer biomarker
Phosphorus MRS offers a non‐invasive tool for monitoring cell energy and phospholipid metabolism and can be of additional value in diagnosing cancer and monitoring cancer therapy. In this study, we determined the transverse relaxation times of a number of phosphorous metabolites in a group of breast cancer patients by adiabatic multi‐echo spectroscopic imaging at 7 T. The transverse relaxation times of phosphoethanolamine, phosphocholine, inorganic phosphate (Pi), glycerophosphocholine and glycerophosphatidylcholine were 184 ± 8 ms, 203 ± 17 ms, 87 ± 8 ms, 240 ± 56 ms and 20 ± 10 ms, respectively. The transverse relaxation time of Pi in breast cancer tissue was less than half that of healthy fibroglandular tissue. This effect is most likely caused by an up‐regulation of glycolysis in breast cancer tissue that leads to interaction of Pi with the GAPDH enzyme, which forms part of the reversible pathway of exchange of Pi with gamma‐adenosine tri‐phosphate, thus shortening its apparent transverse relaxation time. As healthy breast tissue shows very little glycolytic activity, the apparent T2 shortening of Pi due to malignant transformation could possibly be used as a biomarker for cancer.
- Open Access
- 1 July 2018
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 80 (1) , 29-35
31P T2s of phosphomonoesters, phosphodiesters, and inorganic phosphate in the human brain at 7T
PurposeTo determine the phosphorus-31T(2)s of phosphomonoesters, phosphodiesters, and inorganic phosphate in the healthy human brain at 7T. MethodsA 3D chemical shift imaging multi-echo sequence with composite block pulses for refocusing was used to measure one free induction decay (FID) and seven full echoes with an echo spacing of 45 ms on the brain of nine healthy volunteers (age range 22-45 years; average age 278 years). Spectral fitting was used to determine the change in metabolic signal amplitude with echo time. ResultsThe average apparent T(2)s with their standard deviation were 202 +/- 6 ms, 129 +/- 6 ms, 86 +/- 2 ms, 214 +/- 10 ms, and 213 +/- 11 ms for phosphoethanolamine, phosphocholine, inorganic phosphate, glycerophosphoethanolamine, and glycerophosphocholine, respectively. ConclusionThe determined apparent T-2 for phosphoethanolamine, glycerophosphocholine, and glycerophosphoethanolamine is approximately 200 ms. The lower apparent T-2 value for phosphocholine is attributed to the overlap of this resonance with the 3-phosphorous resonance of 2,3-diphosphoglycerate from blood, with an apparent shorter T-2. Omitting the FID signal and the first echo of phosphocholine leads to a T-2 of 182 +/- 7 ms, whereas a biexponential analysis leads to 203 +/- 4 ms. These values are more in line with phosphoethanolamine and the phosphodiesters. The short T-2 of inorganic phosphate is subscribed to the fast reversible exchange with -adenosine triphosphate, which is mediated by glyceraldehyde-3-phosphate dehydrogenase and phosphoglycerate kinase within the glycolytic pathway. Magn Reson Med 80:29-35, 2018. (c) 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
- 1 July 2018
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 80 (1) , 29-35
Open Access31P T2s of phosphomonoesters, phosphodiesters, and inorganic phosphate in the human brain at 7T
PurposeTo determine the phosphorus-31T(2)s of phosphomonoesters, phosphodiesters, and inorganic phosphate in the healthy human brain at 7T. MethodsA 3D chemical shift imaging multi-echo sequence with composite block pulses for refocusing was used to measure one free induction decay (FID) and seven full echoes with an echo spacing of 45 ms on the brain of nine healthy volunteers (age range 22-45 years; average age 278 years). Spectral fitting was used to determine the change in metabolic signal amplitude with echo time. ResultsThe average apparent T(2)s with their standard deviation were 202 +/- 6 ms, 129 +/- 6 ms, 86 +/- 2 ms, 214 +/- 10 ms, and 213 +/- 11 ms for phosphoethanolamine, phosphocholine, inorganic phosphate, glycerophosphoethanolamine, and glycerophosphocholine, respectively. ConclusionThe determined apparent T-2 for phosphoethanolamine, glycerophosphocholine, and glycerophosphoethanolamine is approximately 200 ms. The lower apparent T-2 value for phosphocholine is attributed to the overlap of this resonance with the 3-phosphorous resonance of 2,3-diphosphoglycerate from blood, with an apparent shorter T-2. Omitting the FID signal and the first echo of phosphocholine leads to a T-2 of 182 +/- 7 ms, whereas a biexponential analysis leads to 203 +/- 4 ms. These values are more in line with phosphoethanolamine and the phosphodiesters. The short T-2 of inorganic phosphate is subscribed to the fast reversible exchange with -adenosine triphosphate, which is mediated by glyceraldehyde-3-phosphate dehydrogenase and phosphoglycerate kinase within the glycolytic pathway. Magn Reson Med 80:29-35, 2018. (c) 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
- Open Access
- 28 December 2016
- Published by Wiley in NMR in Biomedicine
- Vol. 30 (2)
Proton and phosphorus magnetic resonance spectroscopy of the healthy human breast at 7 T
In vivo water‐ and fat‐suppressed 1H magnetic resonance spectroscopy (MRS) and 31P magnetic resonance adiabatic multi‐echo spectroscopic imaging were performed at 7 T in duplicate in healthy fibroglandular breast tissue of a group of eight volunteers. The transverse relaxation times of 31P metabolites were determined, and the reproducibility of 1H and 31P MRS was investigated. The transverse relaxation times for phosphoethanolamine (PE) and phosphocholine (PC) were fitted bi‐exponentially, with an added short T2 component of 20 ms for adenosine monophosphate, resulting in values of 199 ± 8 and 239 ± 14 ms, respectively. The transverse relaxation time for glycerophosphocholine (GPC) was also fitted bi‐exponentially, with an added short T2 component of 20 ms for glycerophosphatidylethanolamine, which resonates at a similar frequency, resulting in a value of 177 ± 6 ms. Transverse relaxation times for inorganic phosphate, γ‐ATP and glycerophosphatidylcholine mobile phospholipid were fitted mono‐exponentially, resulting in values of 180 ± 4, 19 ± 3 and 20 ± 4 ms, respectively. Coefficients of variation for the duplicate determinations of 1H total choline (tChol) and the 31P metabolites were calculated for the group of volunteers. The reproducibility of inorganic phosphate, the sum of phosphomonoesters and the sum of phosphodiesters with 31P MRS imaging was superior to the reproducibility of 1H MRS for tChol. 1H and 31P data were combined to calculate estimates of the absolute concentrations of PC, GPC and PE in healthy fibroglandular tissue, resulting in upper limits of 0.1, 0.1 and 0.2 mmol/kg of tissue, respectively.
- 28 December 2016
- Published by Wiley in NMR in Biomedicine
- Vol. 30 (2)
Open AccessProton and phosphorus magnetic resonance spectroscopy of the healthy human breast at 7 T
In vivo water‐ and fat‐suppressed 1H magnetic resonance spectroscopy (MRS) and 31P magnetic resonance adiabatic multi‐echo spectroscopic imaging were performed at 7 T in duplicate in healthy fibroglandular breast tissue of a group of eight volunteers. The transverse relaxation times of 31P metabolites were determined, and the reproducibility of 1H and 31P MRS was investigated. The transverse relaxation times for phosphoethanolamine (PE) and phosphocholine (PC) were fitted bi‐exponentially, with an added short T2 component of 20 ms for adenosine monophosphate, resulting in values of 199 ± 8 and 239 ± 14 ms, respectively. The transverse relaxation time for glycerophosphocholine (GPC) was also fitted bi‐exponentially, with an added short T2 component of 20 ms for glycerophosphatidylethanolamine, which resonates at a similar frequency, resulting in a value of 177 ± 6 ms. Transverse relaxation times for inorganic phosphate, γ‐ATP and glycerophosphatidylcholine mobile phospholipid were fitted mono‐exponentially, resulting in values of 180 ± 4, 19 ± 3 and 20 ± 4 ms, respectively. Coefficients of variation for the duplicate determinations of 1H total choline (tChol) and the 31P metabolites were calculated for the group of volunteers. The reproducibility of inorganic phosphate, the sum of phosphomonoesters and the sum of phosphodiesters with 31P MRS imaging was superior to the reproducibility of 1H MRS for tChol. 1H and 31P data were combined to calculate estimates of the absolute concentrations of PC, GPC and PE in healthy fibroglandular tissue, resulting in upper limits of 0.1, 0.1 and 0.2 mmol/kg of tissue, respectively.
- Open Access
- 7 July 2016
- Published by Springer Nature in SpringerPlus
- Vol. 5 (1) , 1012
Erratum to: Dynamic contrast-enhanced breast MRI at 7T and 3T: an intra-individual comparison study
[This corrects the article DOI: 10.1186/s40064-015-1654-7.].
- 7 July 2016
- Published by Springer Nature in SpringerPlus
- Vol. 5 (1) , 1012
Open AccessErratum to: Dynamic contrast-enhanced breast MRI at 7T and 3T: an intra-individual comparison study
[This corrects the article DOI: 10.1186/s40064-015-1654-7.].
- Open Access
- 15 February 2016
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 6, 29
Glycerophosphocholine and Glycerophosphoethanolamine Are Not the Main Sources of the In Vivo31P MRS Phosphodiester Signals from Healthy Fibroglandular Breast Tissue at 7 T
Purpose: The identification of the phosphodiester 31P MR signals in the healthy human breast at ultra-high field. Methods:In vivo 31P MRS measurements at 7 tesla of the phosphodiester signals in the breast were performed investigating the chemical shifts, the transverse- and the longitudinal relaxation times. Chemical shifts and transverse relaxation times were compared with non-ambiguous phosphodiester signals from the liver. Results: The chemical shifts of the phosphodiester signals are shifted -0.5 ppm with respect to glycerophosphocholine and -ethanolamine, and the transverse and longitudinal relaxation times for these signals are a factor 3 to 4 shorter than expected for aqueous glycerophosphocholine and -ethanolamine. Conclusions: The available experimental evidence suggests that glycerophosphocholine and –ethanolamine are not the main source of the phosphodiester signals measured in fibroglandular breast tissue at 7 tesla. These signals may predominantly originate from mobile phospholipids.
- 15 February 2016
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 6, 29
Open AccessGlycerophosphocholine and Glycerophosphoethanolamine Are Not the Main Sources of the In Vivo31P MRS Phosphodiester Signals from Healthy Fibroglandular Breast Tissue at 7 T
Purpose: The identification of the phosphodiester 31P MR signals in the healthy human breast at ultra-high field. Methods:In vivo 31P MRS measurements at 7 tesla of the phosphodiester signals in the breast were performed investigating the chemical shifts, the transverse- and the longitudinal relaxation times. Chemical shifts and transverse relaxation times were compared with non-ambiguous phosphodiester signals from the liver. Results: The chemical shifts of the phosphodiester signals are shifted -0.5 ppm with respect to glycerophosphocholine and -ethanolamine, and the transverse and longitudinal relaxation times for these signals are a factor 3 to 4 shorter than expected for aqueous glycerophosphocholine and -ethanolamine. Conclusions: The available experimental evidence suggests that glycerophosphocholine and –ethanolamine are not the main source of the phosphodiester signals measured in fibroglandular breast tissue at 7 tesla. These signals may predominantly originate from mobile phospholipids.
- Open Access
- 5 January 2016
- Published by Springer Nature in SpringerPlus
- Vol. 5 (1) , 1-12
Dynamic contrast-enhanced breast MRI at 7T and 3T: an intra-individual comparison study
The aim of this study is to compare the current state of lesion identification, the BI-RADS classification and the contrast-enhancement behavior at 7T and 3T breast MRI in the same patient group. Twenty-seven patients with thirty suspicious lesions were selected for this prospective study and underwent both 7T and 3T MRI. All examinations were rated by two radiologists (R1 and R2) independently on image quality, lesion identification and BI-RADS classification. We assessed sensitivity, specificity, NPV and PPV, observer agreement, lesion sizes, and contrast-enhancement-to-noise ratios (CENRs) of mass lesions. Fifteen of seventeen histopathological proven malignant lesions were detected at both field strengths. Image quality of the dynamic series was good at 7T, and excellent at 3T (P = 0.001 for R1 and P = 0.88 for R2). R1 found higher rates of specificity, NPV and PPV at 7T when compared to 3T, while R2 found the same results for sensitivity, specificity, NPV and PPV for both field strengths. The observers showed excellent agreement for BI-RADS categories at 7T (κ = 0.86) and 3T (κ = 0.93). CENRs were higher at 7T (P = 0.015). Lesion sizes were bigger at 7T according to R2 (P = 0.039). Our comparison study shows that 7T MRI allows BI-RADS conform analysis. Technical improvements, such as acquisition of T2w sequences and adjustment of B1+ field inhomogeneity, are still necessary to allow clinical use of 7T breast MRI.
- 5 January 2016
- Published by Springer Nature in SpringerPlus
- Vol. 5 (1) , 1-12
Open AccessDynamic contrast-enhanced breast MRI at 7T and 3T: an intra-individual comparison study
The aim of this study is to compare the current state of lesion identification, the BI-RADS classification and the contrast-enhancement behavior at 7T and 3T breast MRI in the same patient group. Twenty-seven patients with thirty suspicious lesions were selected for this prospective study and underwent both 7T and 3T MRI. All examinations were rated by two radiologists (R1 and R2) independently on image quality, lesion identification and BI-RADS classification. We assessed sensitivity, specificity, NPV and PPV, observer agreement, lesion sizes, and contrast-enhancement-to-noise ratios (CENRs) of mass lesions. Fifteen of seventeen histopathological proven malignant lesions were detected at both field strengths. Image quality of the dynamic series was good at 7T, and excellent at 3T (P = 0.001 for R1 and P = 0.88 for R2). R1 found higher rates of specificity, NPV and PPV at 7T when compared to 3T, while R2 found the same results for sensitivity, specificity, NPV and PPV for both field strengths. The observers showed excellent agreement for BI-RADS categories at 7T (κ = 0.86) and 3T (κ = 0.93). CENRs were higher at 7T (P = 0.015). Lesion sizes were bigger at 7T according to R2 (P = 0.039). Our comparison study shows that 7T MRI allows BI-RADS conform analysis. Technical improvements, such as acquisition of T2w sequences and adjustment of B1+ field inhomogeneity, are still necessary to allow clinical use of 7T breast MRI.
- 29 September 2015
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 76 (2) , 402-407
Saturation-transfer effects and longitudinal relaxation times of 31 P metabolites in fibroglandular breast tissue at 7T
- 29 September 2015
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 76 (2) , 402-407
Saturation-transfer effects and longitudinal relaxation times of 31 P metabolites in fibroglandular breast tissue at 7T
- Open Access
- 27 October 2014
- Published by Springer Nature in SpringerPlus
- Vol. 3 (1) , 634
Detection of alterations in membrane metabolism during neoadjuvant chemotherapy in patients with breast cancer using phosphorus magnetic resonance spectroscopy at 7 Tesla
Here we investigate the feasibility of tumor metabolism monitoring in T1c to T3 breast cancer during neoadjuvant chemotherapy by means of phosphorus (31P) magnetic resonance spectroscopy at 7 tesla (T). Five breast cancer patients were examined using a 31P MRSI sequence, prior to-, halfway-, and after neoadjuvant chemotherapy. The 31P MRSI data were analyzed on group and individual level and compared to a spectrum of a group of healthy volunteers. Ratios of phosphomonoesters (PME) to phosphodiesters (PDE) and phosphomonoesters to inorganic phosphate (Pi) were determined. Histopathologic assessment showed four partial responders and one complete responder to chemotherapy. The 31P spectrum of the patient group was distinctly different from the 31P spectrum of healthy volunteers and transformed its shape during the course of chemotherapy towards the shape of the spectrum of the healthy volunteers. Prior to chemotherapy the PME to PDE signal ratio and the PME to Pi signal ratio were high, and during the course of the chemotherapy these ratios normalized to the value of the healthy volunteers. Metabolite T2 values in tumor tissue tended to be lower than those for healthy glandular tissue. Assessment of individual patients showed that four out of five had a significant drop of the PME to Pi ratio by a factor of 2 or more. On average, the pH of the tumor, calculated from chemical shift variation of Pi, was 0.19 units lower before chemotherapy. We have demonstrated that the sensitivity of 31P MRSI in breast cancer at 7 T is sufficient to detect alterations in membrane metabolism during neoadjuvant chemotherapy, which may be used for early assessment of treatment efficacy.
- 27 October 2014
- Published by Springer Nature in SpringerPlus
- Vol. 3 (1) , 634
Open AccessDetection of alterations in membrane metabolism during neoadjuvant chemotherapy in patients with breast cancer using phosphorus magnetic resonance spectroscopy at 7 Tesla
Here we investigate the feasibility of tumor metabolism monitoring in T1c to T3 breast cancer during neoadjuvant chemotherapy by means of phosphorus (31P) magnetic resonance spectroscopy at 7 tesla (T). Five breast cancer patients were examined using a 31P MRSI sequence, prior to-, halfway-, and after neoadjuvant chemotherapy. The 31P MRSI data were analyzed on group and individual level and compared to a spectrum of a group of healthy volunteers. Ratios of phosphomonoesters (PME) to phosphodiesters (PDE) and phosphomonoesters to inorganic phosphate (Pi) were determined. Histopathologic assessment showed four partial responders and one complete responder to chemotherapy. The 31P spectrum of the patient group was distinctly different from the 31P spectrum of healthy volunteers and transformed its shape during the course of chemotherapy towards the shape of the spectrum of the healthy volunteers. Prior to chemotherapy the PME to PDE signal ratio and the PME to Pi signal ratio were high, and during the course of the chemotherapy these ratios normalized to the value of the healthy volunteers. Metabolite T2 values in tumor tissue tended to be lower than those for healthy glandular tissue. Assessment of individual patients showed that four out of five had a significant drop of the PME to Pi ratio by a factor of 2 or more. On average, the pH of the tumor, calculated from chemical shift variation of Pi, was 0.19 units lower before chemotherapy. We have demonstrated that the sensitivity of 31P MRSI in breast cancer at 7 T is sufficient to detect alterations in membrane metabolism during neoadjuvant chemotherapy, which may be used for early assessment of treatment efficacy.
- 22 August 2014
- Published by Wiley in NMR in Biomedicine
- Vol. 27 (10) , 1248-1255
Increased sensitivity of 31P MRSI using direct detection integrated with multi‐echo polarization transfer (DIMEPT)
Here, we show that the sensitivity of 31P MRSI of 31P spins J‐coupled to protons can be increased by almost a factor of three when compared with an optimal direct detection free induction decay. By direct detection integrated with multi‐echo polarization transfer (DIMEPT), multiple signals from polarization transfer and direct detection can be acquired in one repetition time, with minimal mutual interference, provided that the number of refocusing pulses in the multi‐echo polarization transfer part is even. The DIMEPT sequence was implemented on a 7‐T body scanner and tested on a phantom and on the breasts of five healthy volunteers. The in vivo signal‐to‐noise ratio (SNR) enhancement for the J‐coupled phosphomonoesters was 270% when compared with an Ernst angle pulse‐acquire sequence. However, the phosphodiester signals, presumably mainly mobile phospholipids, had T2 values that were too short to be enhanced. Uncoupled 31P spins, with sufficiently long T2 values, such as inorganic phosphate, were SNR enhanced by a factor of 1.9 relative to an Ernst‐angle excitation pulse‐acquire sequence by multi‐echo direct detection. Copyright © 2014 John Wiley & Sons, Ltd.
- 22 August 2014
- Published by Wiley in NMR in Biomedicine
- Vol. 27 (10) , 1248-1255
Increased sensitivity of 31P MRSI using direct detection integrated with multi‐echo polarization transfer (DIMEPT)
Here, we show that the sensitivity of 31P MRSI of 31P spins J‐coupled to protons can be increased by almost a factor of three when compared with an optimal direct detection free induction decay. By direct detection integrated with multi‐echo polarization transfer (DIMEPT), multiple signals from polarization transfer and direct detection can be acquired in one repetition time, with minimal mutual interference, provided that the number of refocusing pulses in the multi‐echo polarization transfer part is even. The DIMEPT sequence was implemented on a 7‐T body scanner and tested on a phantom and on the breasts of five healthy volunteers. The in vivo signal‐to‐noise ratio (SNR) enhancement for the J‐coupled phosphomonoesters was 270% when compared with an Ernst angle pulse‐acquire sequence. However, the phosphodiester signals, presumably mainly mobile phospholipids, had T2 values that were too short to be enhanced. Uncoupled 31P spins, with sufficiently long T2 values, such as inorganic phosphate, were SNR enhanced by a factor of 1.9 relative to an Ernst‐angle excitation pulse‐acquire sequence by multi‐echo direct detection. Copyright © 2014 John Wiley & Sons, Ltd.
- 2 April 2013
- Published by Wiley in NMR in Biomedicine
- Vol. 26 (10) , 1299-1307
Adiabatic multi‐echo 31P spectroscopic imaging (AMESING) at 7 T for the measurement of transverse relaxation times and regaining of sensitivity in tissues with short T2* values
An adiabatic multi‐echo spectroscopic imaging (AMESING) sequence, used for 31P MRSI, with spherical k‐space sampling and compensated phase‐encoding gradients, was implemented on a whole‐body 7‐T MR system. One free induction decay (FID) and up to five symmetric echoes can be acquired with this sequence. In tissues with low T2* and high T2, this can theoretically lead to a potential maximum signal‐to‐noise ratio (SNR) increase of almost a factor of three, compared with a conventional FID acquisition with Ernst‐angle excitation. However, with T2 values being, in practice, ≤400 ms, a maximum enhancement of approximately two compared with low flip Ernst‐angle excitation should be feasible. The multi‐echo sequence enables the determination of localized T2 values, and was validated with 31P three‐dimensional MRSI on the calf muscle and breast of a healthy volunteer, and subsequently applied in a patient with breast cancer. The T2 values of phosphocreatine, phosphodiesters (PDE) and inorganic phosphate in calf muscle were 193 ± 5 ms, 375 ± 44 ms and 96 ± 10 ms, respectively, and the apparent T2 value of γ‐ATP was 25 ± 6 ms. A T2 value of 136 ± 15 ms for inorganic phosphate was measured in glandular breast tissue of a healthy volunteer. The T2 values of phosphomonoesters (PME) and PDE in breast cancer tissue (ductulolobular carcinoma) ranged between 170 and 210 ms, and the PME to PDE ratios were calculated to be phosphoethanolamine/glycerophosphoethanolamine = 2.7, phosphocholine/glycerophosphocholine = 1.8 and PME/PDE = 2.3. Considering the relatively short T2* values of the metabolites in breast tissue at 7 T, the echo spacing can be short without compromising spectral resolution, whilst maximizing the sensitivity. Copyright © 2013 John Wiley & Sons, Ltd.
- 2 April 2013
- Published by Wiley in NMR in Biomedicine
- Vol. 26 (10) , 1299-1307
Adiabatic multi‐echo 31P spectroscopic imaging (AMESING) at 7 T for the measurement of transverse relaxation times and regaining of sensitivity in tissues with short T2* values
An adiabatic multi‐echo spectroscopic imaging (AMESING) sequence, used for 31P MRSI, with spherical k‐space sampling and compensated phase‐encoding gradients, was implemented on a whole‐body 7‐T MR system. One free induction decay (FID) and up to five symmetric echoes can be acquired with this sequence. In tissues with low T2* and high T2, this can theoretically lead to a potential maximum signal‐to‐noise ratio (SNR) increase of almost a factor of three, compared with a conventional FID acquisition with Ernst‐angle excitation. However, with T2 values being, in practice, ≤400 ms, a maximum enhancement of approximately two compared with low flip Ernst‐angle excitation should be feasible. The multi‐echo sequence enables the determination of localized T2 values, and was validated with 31P three‐dimensional MRSI on the calf muscle and breast of a healthy volunteer, and subsequently applied in a patient with breast cancer. The T2 values of phosphocreatine, phosphodiesters (PDE) and inorganic phosphate in calf muscle were 193 ± 5 ms, 375 ± 44 ms and 96 ± 10 ms, respectively, and the apparent T2 value of γ‐ATP was 25 ± 6 ms. A T2 value of 136 ± 15 ms for inorganic phosphate was measured in glandular breast tissue of a healthy volunteer. The T2 values of phosphomonoesters (PME) and PDE in breast cancer tissue (ductulolobular carcinoma) ranged between 170 and 210 ms, and the PME to PDE ratios were calculated to be phosphoethanolamine/glycerophosphoethanolamine = 2.7, phosphocholine/glycerophosphocholine = 1.8 and PME/PDE = 2.3. Considering the relatively short T2* values of the metabolites in breast tissue at 7 T, the echo spacing can be short without compromising spectral resolution, whilst maximizing the sensitivity. Copyright © 2013 John Wiley & Sons, Ltd.