V. A. Baskov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
V. A. Baskov has a total of 66 co-authors. Here are the top co-authors by number of shared publications:
V. I. Alekseev
Lebedev Physical Institute, Russian Academy of Sciences, Moscow, Russia
20 shared publicationsA. I. L’VOv
Lebedev Physical Institute, Russian Academy of Sciences, Moscow, Russia
18 shared publicationsV. A. Dronov
Lebedev Physical Institute, Russian Academy of Sciences, Moscow, Russia
18 shared publicationsYu. F. Krechetov
Joint Institute for Nuclear Research, Dubna, Russia
17 shared publicationsV. V. Polyansky
Lebedev Physical Institute, Russian Academy of Sciences, Moscow, Russian Federation
16 shared publicationsS. S. Sidorin
Lebedev Physical Institute, Russian Academy of Sciences, Moscow, Russia
15 shared publications
Latest Publications
- 1 October 2025
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 68 (5) , 677-682
An Amplitude−Time Scintillation Spectrometer
A two-channel scintillation spectrometer with a thickness of 0.5X0 has been calibrated on the secondary electron beam at the Pakhra accelerator of the Lebedev Physical Institute, Russian Academy of Sciences. The amplitude and time recording systems of the spectrometer are based on FEU-49 and FEU-85 photomultiplier tubes, respectively. The relative energy resolution of the scintillation spectrometer is ~5% at electron energy E ∼ 30 MeV. The nonlinear dependence of the average channel of the time-resolved spectrum on the electron energy is observed at electron energies E < 40 MeV, and the average channel of the time-resolved spectrum is independent of the energy at E ≥ 40 MeV.
- 1 October 2025
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 68 (5) , 677-682
An Amplitude−Time Scintillation Spectrometer
A two-channel scintillation spectrometer with a thickness of 0.5X0 has been calibrated on the secondary electron beam at the Pakhra accelerator of the Lebedev Physical Institute, Russian Academy of Sciences. The amplitude and time recording systems of the spectrometer are based on FEU-49 and FEU-85 photomultiplier tubes, respectively. The relative energy resolution of the scintillation spectrometer is ~5% at electron energy E ∼ 30 MeV. The nonlinear dependence of the average channel of the time-resolved spectrum on the electron energy is observed at electron energies E < 40 MeV, and the average channel of the time-resolved spectrum is independent of the energy at E ≥ 40 MeV.
- 1 March 2025
- Published by Allerton Press in Bulletin of the Lebedev Physics Institute
- Vol. 52 (3) , 114-118
Two-Channel Scintillation Spectrometer
We report the results of calibration of a two-channel scintillation spectrometer with a thickness of 0.5X0 on the secondary electron beam of the Pakhra acc
- 1 March 2025
- Published by Allerton Press in Bulletin of the Lebedev Physics Institute
- Vol. 52 (3) , 114-118
Two-Channel Scintillation Spectrometer
We report the results of calibration of a two-channel scintillation spectrometer with a thickness of 0.5X0 on the secondary electron beam of the Pakhra acc
- 1 October 2024
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 67 (5) , 870-880
Energy Resolution of a Spectrometer with an Oriented Crystal Converter
A single-crystal converter oriented along the axis is placed in front of an electromagnetic spectrometer to change the response of the spectrometer that measures electrons with energies of several tens of GeV. The relative energy resolution of the spectrometer is improved by 15−80% depending on the orientation, thickness, and type of the crystal converter and the spectrometer thickness at electron energies of 26 and 28 GeV.
- 1 October 2024
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 67 (5) , 870-880
Energy Resolution of a Spectrometer with an Oriented Crystal Converter
A single-crystal converter oriented along the axis is placed in front of an electromagnetic spectrometer to change the response of the spectrometer that measures electrons with energies of several tens of GeV. The relative energy resolution of the spectrometer is improved by 15−80% depending on the orientation, thickness, and type of the crystal converter and the spectrometer thickness at electron energies of 26 and 28 GeV.
- 16 September 2024
- Published by The Russian Academy of Sciences in Приборы и техника эксперимента
- No. 1,p. 20-25
Сцинтилляционный времяпролетный годоскоп
Сцинтилляционный времяпролетный годоскоп Сцинтилляционный времяпролетный годоскоп
- 16 September 2024
- Published by The Russian Academy of Sciences in Приборы и техника эксперимента
- No. 1,p. 20-25
Сцинтилляционный времяпролетный годоскоп
Сцинтилляционный времяпролетный годоскоп Сцинтилляционный времяпролетный годоскоп
- 1 June 2024
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 67 (3) , 439-442
A Scintillation Amplitude−Coordinate Spectrometer
The scintillation amplitude−coordinate spectrometer with a thickness of 0.58X0 has been calibrated using cosmic radiation. The light signals in the spectrometer are detected by FEU-49 and FEU-85 photomultiplier tubes, which determine the amplitude and coordinate systems, respectively. It has been established that the relative amplitude and coordinate resolutions depend on the point of particle incidence on the spectrometer. The relative amplitude and coordinate resolutions measured at the center of the spectrometer appear to be the best, and their values are ~8.7% and ~1.6 cm, respectively.
- 1 June 2024
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 67 (3) , 439-442
A Scintillation Amplitude−Coordinate Spectrometer
The scintillation amplitude−coordinate spectrometer with a thickness of 0.58X0 has been calibrated using cosmic radiation. The light signals in the spectrometer are detected by FEU-49 and FEU-85 photomultiplier tubes, which determine the amplitude and coordinate systems, respectively. It has been established that the relative amplitude and coordinate resolutions depend on the point of particle incidence on the spectrometer. The relative amplitude and coordinate resolutions measured at the center of the spectrometer appear to be the best, and their values are ~8.7% and ~1.6 cm, respectively.
- 1 February 2024
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 67 (1) , 13-19
A Scintillation Time-of-Flight Hodoscope
The characteristics of a 50-cm-long module of the scintillation time-of-flight hodoscope have been studied. It has been determined that the coordinate resolution and detection efficiency of the module depend on the voltages applied to the voltage dividers of the photomultiplier tubes and the distance from the hip point of a particle to the photomultiplier tubes. The module has been tested using both a secondary electron beam of the Pakhra accelerator (Lebedev Physical Institute, Russian Academy of Sciences) with an energy of 20 MeV and a 90Sr+90Y radioactive source. The tests show that the minimum values of the coordinate resolution are σx ≈ 0.1 and 1.3 cm, respectively, and the detection efficiency is ε ≈ 53%.
- 1 February 2024
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 67 (1) , 13-19
A Scintillation Time-of-Flight Hodoscope
The characteristics of a 50-cm-long module of the scintillation time-of-flight hodoscope have been studied. It has been determined that the coordinate resolution and detection efficiency of the module depend on the voltages applied to the voltage dividers of the photomultiplier tubes and the distance from the hip point of a particle to the photomultiplier tubes. The module has been tested using both a secondary electron beam of the Pakhra accelerator (Lebedev Physical Institute, Russian Academy of Sciences) with an energy of 20 MeV and a 90Sr+90Y radioactive source. The tests show that the minimum values of the coordinate resolution are σx ≈ 0.1 and 1.3 cm, respectively, and the detection efficiency is ε ≈ 53%.
- 1 January 2024
- Published by Allerton Press in Bulletin of the Lebedev Physics Institute
- Vol. 51 (1) , 21-24
The Prototype of a Magnetic Field Compensator
The paper describes the design of a prototype magnetic field compensator intended to eliminate the influence of the edge magnetic field of the S-25P Pakhra
- 1 January 2024
- Published by Allerton Press in Bulletin of the Lebedev Physics Institute
- Vol. 51 (1) , 21-24
The Prototype of a Magnetic Field Compensator
The paper describes the design of a prototype magnetic field compensator intended to eliminate the influence of the edge magnetic field of the S-25P Pakhra
- 4 December 2023
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 66 (6) , 948-956
Calibration Beam of Low-Energy Secondary Electrons at the Pakhra Accelerator of the Lebedev Physical Institute
The characteristics of the calibration beam of secondary electrons at the Pakhra accelerator based on the SP-3 magnet at the Lebedev Physical Institute are presented. The energy resolution of a beam with a 2-mm-thick copper converter in the electron energy range E = 5–100 MeV is δ ≈ 10%.
- 4 December 2023
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 66 (6) , 948-956
Calibration Beam of Low-Energy Secondary Electrons at the Pakhra Accelerator of the Lebedev Physical Institute
The characteristics of the calibration beam of secondary electrons at the Pakhra accelerator based on the SP-3 magnet at the Lebedev Physical Institute are presented. The energy resolution of a beam with a 2-mm-thick copper converter in the electron energy range E = 5–100 MeV is δ ≈ 10%.
- 1 November 2023
- Published by The Russian Academy of Sciences in Приборы и техника эксперимента
- No. 6,p. 59-68
Калибровочный пучок вторичных электронов низких энергий ускорителя ФИАН “Пахра”
Калибровочный пучок вторичных электронов низких энергий ускорителя ФИАН “Пахра”
- 1 November 2023
- Published by The Russian Academy of Sciences in Приборы и техника эксперимента
- No. 6,p. 59-68
Калибровочный пучок вторичных электронов низких энергий ускорителя ФИАН “Пахра”
Калибровочный пучок вторичных электронов низких энергий ускорителя ФИАН “Пахра”
- 1 August 2023
- Published by Allerton Press in Bulletin of the Lebedev Physics Institute
- Vol. 50 (8) , 354-359
Prototype of the Scintillation Time-of-Flight Hodoscope
The results of studies of the characteristics of the prototype of the scintillation time-of-flight hodoscope 71 cm long are presented. Prototype testing us
- 1 August 2023
- Published by Allerton Press in Bulletin of the Lebedev Physics Institute
- Vol. 50 (8) , 354-359
Prototype of the Scintillation Time-of-Flight Hodoscope
The results of studies of the characteristics of the prototype of the scintillation time-of-flight hodoscope 71 cm long are presented. Prototype testing us