Deepak Pant
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Deepak Pant has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Anvita Sheel
Department of Environmental Sciences, Central University of Himachal Pradesh, Dharamshala, Himachal Pradesh 176215, India
1 shared publication- Pooja Singh
Uttarakhand Technical University
1 shared publication Rajkumar Joshi
Department of Science and Technology
1 shared publicationTenzin Dolker
Department of Environmental Sciences, Central University of Himachal Pradesh, Dharamshala, Himachal Pradesh 176215, India
1 shared publication
Latest Publications
- 1 January 2018
- Published by Elsevier in Bioresource Technology
- Vol. 247, 1189-1192
Recovery of gold from electronic waste using chemical assisted microbial biosorption (hybrid) technique
- 1 January 2018
- Published by Elsevier in Bioresource Technology
- Vol. 247, 1189-1192
Recovery of gold from electronic waste using chemical assisted microbial biosorption (hybrid) technique
- 1 February 2017
- Published by Elsevier in Waste Management
- Vol. 60, 689-695
Green and facile method for the recovery of spent Lithium Nickel Manganese Cobalt Oxide (NMC) based Lithium ion batteries
- 1 February 2017
- Published by Elsevier in Waste Management
- Vol. 60, 689-695
Green and facile method for the recovery of spent Lithium Nickel Manganese Cobalt Oxide (NMC) based Lithium ion batteries
- 27 November 2013
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 21 (4) , 2414-2436
Pollution due to hazardous glass waste
Pollution resulting from hazardous glass (HG) is widespread across the globe, both in terms of quantity and associated health risks. In waste cathode ray tube (CRT) and fluorescent lamp glass, mercury and lead are present as the major pollutants. The current review discusses the issues related to quantity and associated risk from the pollutant present in HG and proposes the chemical, biological, thermal, hybrid, and nanotechniques for its management. The hybrid is one of the upcoming research models involving the compatible combination of two or more techniques for better and efficient remediation. Thermal mercury desorption starts at 100 °C but for efficient removal, the temperature should be >460 °C. Involvement of solar energy for this purpose makes the research more viable and ecofriendly. Nanoparticles such as Fe, Se, Cu, Ni, Zn, Ag, and WS2 alone or with its formulation can immobilize heavy metals present in HG by involving a redox mechanism. Straight-line equation from year-wise sale can provide future sale data in comparison with lifespan which gives future pollutant approximation. Waste compact fluorescent lamps units projected for the year 2015 is 9,300,000,000 units and can emit nearly 9,300 kg of mercury. On the other hand, CRT monitors have been continuously replaced by more improved versions like liquid crystal display and plasma display panel resulting in the production of more waste. Worldwide CRT production was 83,300,000 units in 2002 and can approximately release 83,000 metric tons of lead.
- 27 November 2013
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 21 (4) , 2414-2436
Pollution due to hazardous glass waste
Pollution resulting from hazardous glass (HG) is widespread across the globe, both in terms of quantity and associated health risks. In waste cathode ray tube (CRT) and fluorescent lamp glass, mercury and lead are present as the major pollutants. The current review discusses the issues related to quantity and associated risk from the pollutant present in HG and proposes the chemical, biological, thermal, hybrid, and nanotechniques for its management. The hybrid is one of the upcoming research models involving the compatible combination of two or more techniques for better and efficient remediation. Thermal mercury desorption starts at 100 °C but for efficient removal, the temperature should be >460 °C. Involvement of solar energy for this purpose makes the research more viable and ecofriendly. Nanoparticles such as Fe, Se, Cu, Ni, Zn, Ag, and WS2 alone or with its formulation can immobilize heavy metals present in HG by involving a redox mechanism. Straight-line equation from year-wise sale can provide future sale data in comparison with lifespan which gives future pollutant approximation. Waste compact fluorescent lamps units projected for the year 2015 is 9,300,000,000 units and can emit nearly 9,300 kg of mercury. On the other hand, CRT monitors have been continuously replaced by more improved versions like liquid crystal display and plasma display panel resulting in the production of more waste. Worldwide CRT production was 83,300,000 units in 2002 and can approximately release 83,000 metric tons of lead.
- 31 July 2009
- Published by Elsevier in Waste Management
- Vol. 29 (7) , 2040-2041
Waste glass as absorbent for thin layer chromatography (TLC)
- 31 July 2009
- Published by Elsevier in Waste Management
- Vol. 29 (7) , 2040-2041
Waste glass as absorbent for thin layer chromatography (TLC)