David J. Larson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
David J. Larson has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
B.P. Geiser
CAMECA Instruments Inc., 5470 Nobel Drive, Madison, WI53711USA
3 shared publicationsT.J. Prosa
CAMECA Instruments Inc., 5470 Nobel Drive, Madison, WI53711USA
3 shared publicationsBrian P. Geiser
CAMECA Instruments, Inc 5500 Nobel Drive 53711 Madison WI USA
2 shared publicationsD Lawrence
CAMECA Instruments, Inc., 5500 Nobel Drive, Madison, WI 53711 USA
2 shared publicationsD Olson
CAMECA Instruments, Inc., 5500 Nobel Drive, Madison, WI 53711 USA
2 shared publicationsD.A. Reinhard
CAMECA Instruments Inc., 5470 Nobel Drive, Madison, WI53711USA
2 shared publications
Latest Publications
- Open Access
- 22 July 2023
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 29 (Supplement) , 609-610
Improving Analytical Capability via Simultaneous Voltage and Laser Pulsing in Atom Probe Tomography
Voltage and laser pulsing (V+L) in atom probe tomography (APT) [ 1] has been proposed as a means to improve sensitivity and compositional accuracy [ 2, 3]. In this pulsing scheme, background reduction [ 2, 4] and mass spectral peak sharpening [ 3] may be achieved, especially for materials with poor thermal diffusivity. Recently, background reduction was achieved for a variety of materials, including aluminum (∼8X), stainless steel (∼4X), silicon (∼15X), and silicon dioxide (∼2X) [ 4]. This work further explores the phenomenon described in [ 3] with respect to using a voltage pulse to improve the peak shapes from a specimen in order to improve mass resolving power (MRP) and thus improve compositional accuracy.
- 22 July 2023
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 29 (Supplement) , 609-610
Open AccessImproving Analytical Capability via Simultaneous Voltage and Laser Pulsing in Atom Probe Tomography
Voltage and laser pulsing (V+L) in atom probe tomography (APT) [ 1] has been proposed as a means to improve sensitivity and compositional accuracy [ 2, 3]. In this pulsing scheme, background reduction [ 2, 4] and mass spectral peak sharpening [ 3] may be achieved, especially for materials with poor thermal diffusivity. Recently, background reduction was achieved for a variety of materials, including aluminum (∼8X), stainless steel (∼4X), silicon (∼15X), and silicon dioxide (∼2X) [ 4]. This work further explores the phenomenon described in [ 3] with respect to using a voltage pulse to improve the peak shapes from a specimen in order to improve mass resolving power (MRP) and thus improve compositional accuracy.
- 22 July 2022
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 28 (S1) , 718-720
Simultaneous Voltage and Laser Pulsing in Atom Probe Tomography
- 22 July 2022
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 28 (S1) , 718-720
Simultaneous Voltage and Laser Pulsing in Atom Probe Tomography
- 26 January 2019
- Published by Elsevier in Materials Characterization
- Vol. 149, 248
Modeling and simulation in atom probe tomography
- 26 January 2019
- Published by Elsevier in Materials Characterization
- Vol. 149, 248
Modeling and simulation in atom probe tomography
- 1 August 2018
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 24 (S1) , 1084-1085
A High Multiple Hits Correction Factor for Atom Probe Tomography
- 1 August 2018
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 24 (S1) , 1084-1085
A High Multiple Hits Correction Factor for Atom Probe Tomography
- Open Access
- 9 March 2017
- Published by American Society for Clinical Investigation in JCI Insight
- Vol. 2 (5) , e90349
Imaging mass spectrometry demonstrates age-related decline in human adipose plasticity
Quantification of stable isotope tracers has revealed the dynamic state of living tissues. A new form of imaging mass spectrometry quantifies isotope ratios in domains much smaller than a cubic micron, enabling measurement of cell turnover and metabolism with stable isotope tracers at the single-cell level with a methodology we refer to as multi-isotope imaging mass spectrometry. In a first-in-human study, we utilize stable isotope tracers of DNA synthesis and de novo lipogenesis to prospectively measure cell birth and adipocyte lipid turnover. In a study of healthy adults, we elucidate an age-dependent decline in new adipocyte generation and adipocyte lipid turnover. A linear regression model suggests that the aging effect could be mediated by a decline in insulin-like growth factor-1 (IGF-1). This study therefore establishes a method for measurement of cell turnover and metabolism in humans with subcellular resolution while implicating the growth hormone/IGF-1 axis in adipose tissue aging.
- 9 March 2017
- Published by American Society for Clinical Investigation in JCI Insight
- Vol. 2 (5) , e90349
Open AccessImaging mass spectrometry demonstrates age-related decline in human adipose plasticity
Quantification of stable isotope tracers has revealed the dynamic state of living tissues. A new form of imaging mass spectrometry quantifies isotope ratios in domains much smaller than a cubic micron, enabling measurement of cell turnover and metabolism with stable isotope tracers at the single-cell level with a methodology we refer to as multi-isotope imaging mass spectrometry. In a first-in-human study, we utilize stable isotope tracers of DNA synthesis and de novo lipogenesis to prospectively measure cell birth and adipocyte lipid turnover. In a study of healthy adults, we elucidate an age-dependent decline in new adipocyte generation and adipocyte lipid turnover. A linear regression model suggests that the aging effect could be mediated by a decline in insulin-like growth factor-1 (IGF-1). This study therefore establishes a method for measurement of cell turnover and metabolism in humans with subcellular resolution while implicating the growth hormone/IGF-1 axis in adipose tissue aging.
- 8 January 2016
- Published by Springer Nature in MRS Bulletin
- Vol. 41 (1) , 30-34
Atom probe tomography of nanoscale electronic materials
- 8 January 2016
- Published by Springer Nature in MRS Bulletin
- Vol. 41 (1) , 30-34
Atom probe tomography of nanoscale electronic materials
- Open Access
Atom Probe Tomography Spatial Reconstruction: Status and Directions
In this review we present an overview of the current atom probe tomography spatial data reconstruction paradigm, and explore some of potential routes to improve the current methodology in order to yield a more accurate representation of nanoscale microstructure. Many of these potential improvement methods are directly tied to extensive application of advanced numerical methods, which are also very briefly reviewed. We have described effects resulting from the application of the standard model and then introduced several potential improvements, first in the far field, and, second, in the near field. The issues encountered in both cases are quite different but ultimately they combine to determine the spatial resolution of the technique.
Open AccessAtom Probe Tomography Spatial Reconstruction: Status and Directions
In this review we present an overview of the current atom probe tomography spatial data reconstruction paradigm, and explore some of potential routes to improve the current methodology in order to yield a more accurate representation of nanoscale microstructure. Many of these potential improvement methods are directly tied to extensive application of advanced numerical methods, which are also very briefly reviewed. We have described effects resulting from the application of the standard model and then introduced several potential improvements, first in the far field, and, second, in the near field. The issues encountered in both cases are quite different but ultimately they combine to determine the spatial resolution of the technique.
- Open Access
- 29 November 2013
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 471 (1) , 012030
Atom probe tomography of a commercial light emitting diode
The atomic-scale analysis of a commercial light emitting diode device purchased at retail is demonstrated using a local electrode atom probe. Some of the features are correlated with transmission electron microscopy imaging. Subtle details of the structure that are revealed have potential significance for the design and performance of this device.
- 29 November 2013
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 471 (1) , 012030
Open AccessAtom probe tomography of a commercial light emitting diode
The atomic-scale analysis of a commercial light emitting diode device purchased at retail is demonstrated using a local electrode atom probe. Some of the features are correlated with transmission electron microscopy imaging. Subtle details of the structure that are revealed have potential significance for the design and performance of this device.
- 12 October 2012
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 18 (5) , 953-963
On the Use of Simulated Field-Evaporated Specimen Apex Shapes in Atom Probe Tomography Data Reconstruction
The ability to accurately reconstruct original spatial positions of field-evaporated ions emitted from a surface is fundamental to the success of atom probe tomography. As such, a clear understanding of the evolution of specimen shape and the resultant ions' trajectories during field evaporation plays an important role in improving reconstruction accuracy. To further this understanding, field-evaporation simulations of a bilayer specimen composed of two materials having an evaporation field difference of 20% were performed. The simulated field-evaporation patterns qualitatively compare favorably with experimental data, which provides confidence in the accuracy of specimen shapes predicted by the simulation. Correlations of known original atom positions with detector hit positions as a function of lateral detector position and evaporated depth were derived from the simulation. These correlations are contrasted with the current state-of-the-art reconstruction method thus outlining limitations of the current methodology. A pair of transformations are defined that take into account field-evaporated specimen shapes, and the resulting radial magnifications, to relate recorded ion positions in detector space to reconstructed atomic positions in specimen space. This novel process, when applied to simulated data, results in approximately a factor of 2 improvement in accuracy for reconstructions of interfaces with unequal fields (most general interfaces). This method is not constrained by the fundamental assumption of a hemispherical specimen shape.
- 12 October 2012
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 18 (5) , 953-963
On the Use of Simulated Field-Evaporated Specimen Apex Shapes in Atom Probe Tomography Data Reconstruction
The ability to accurately reconstruct original spatial positions of field-evaporated ions emitted from a surface is fundamental to the success of atom probe tomography. As such, a clear understanding of the evolution of specimen shape and the resultant ions' trajectories during field evaporation plays an important role in improving reconstruction accuracy. To further this understanding, field-evaporation simulations of a bilayer specimen composed of two materials having an evaporation field difference of 20% were performed. The simulated field-evaporation patterns qualitatively compare favorably with experimental data, which provides confidence in the accuracy of specimen shapes predicted by the simulation. Correlations of known original atom positions with detector hit positions as a function of lateral detector position and evaporated depth were derived from the simulation. These correlations are contrasted with the current state-of-the-art reconstruction method thus outlining limitations of the current methodology. A pair of transformations are defined that take into account field-evaporated specimen shapes, and the resulting radial magnifications, to relate recorded ion positions in detector space to reconstructed atomic positions in specimen space. This novel process, when applied to simulated data, results in approximately a factor of 2 improvement in accuracy for reconstructions of interfaces with unequal fields (most general interfaces). This method is not constrained by the fundamental assumption of a hemispherical specimen shape.
- 17 February 2012
- Published by Springer Nature in MRS Bulletin
- Vol. 37 (2) , 150-158
The second revolution in atom probe tomography
- 17 February 2012
- Published by Springer Nature in MRS Bulletin
- Vol. 37 (2) , 150-158
The second revolution in atom probe tomography