David D. Childs
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
David D. Childs has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Ann Fulcher
Department of Radiology, Virginia Commonwealth University Health, Richmond, USA
1 shared publicationBrenda Holbert
Department of Radiology, Wake Forest University School of Medicine, Medical Center Boulevard, Winston-Salem, NC, 27157, USA
1 shared publication- Brian C. Allen
Department of Radiology, Duke University Medical Center, Durham, NC
1 shared publication - Caio Max Sao Pedro Rocha Lima
Professor, Department of Medicine, Section of Hematology and Oncology
1 shared publication Craig Hall
From the *Department of Radiology, Wake Forest University School of Medicine, Winston-Salem, NC; †Radiology Associates of Daytona Beach, Daytona Beach, FL; and ‡Piedmont Urological Associates, High Point, NC
1 shared publication- Gopi Kota
Wake Forest University School of Medicine
1 shared publication
Latest Publications
- 12 January 2026
- Published by Elsevier in Journal of Minimally Invasive Gynecology
- Vol. 33 (9) , 1222-1223
“Twist of fate”: Parasitized Leiomyoma Causing Recurrent Small Bowel Obstructions
- 12 January 2026
- Published by Elsevier in Journal of Minimally Invasive Gynecology
- Vol. 33 (9) , 1222-1223
“Twist of fate”: Parasitized Leiomyoma Causing Recurrent Small Bowel Obstructions
- 20 November 2023
- Published by Springer Nature in Abdominal Radiology
- Vol. 49 (2) , 384-398
A meta-analysis of the performance of ultrasound, hepatobiliary scintigraphy, CT and MRI in the diagnosis of acute cholecystitis
Purpose To evaluate the recently reported relative diagnostic accuracy of US, CT, MRI, and cholescintigraphy for diagnosing acute cholecystitis. Methods 2 radiologists independently performed systematic electronic searches for articles published between 2000 and 2021 and applied inclusion/exclusion criteria. 2 different radiologists extracted data from the articles and scored each with a methodological quality tool. Pooled estimates of sensitivity and specificity were calculated with a bivariate linear mixed model. A second analysis made head-to-head comparisons (US vs. CT, US vs. cholescintigraphy). Factors were also analyzed for potential confounding effects on diagnostic accuracy. Results Of 6121 initial titles, 22 were included. The prevalence of cholecystitis varied widely across studies (9.4–98%). Pooled sensitivity and specificity estimates were 69% (confidence limit [CL] 62–76%) and 79% (CL 71–86%) for US, 91% (CL 86–94%) and 63% (CL 51–74%) for cholescintigraphy, 78% (CL 69–84%) and 81% (CL 71–88%) for CT, and 91% (CL 78–97%) and 93% (CL 70–99%) for MRI. Regarding head-to-head comparisons, the sensitivity of CT (87.6%, CL 70–96%) was significantly higher than US (66.8%, CL 43–84%), while specificities (81.7% with CL 54–95% for US, 91.9% with CL 67–99% for CT) were similar. The sensitivity of cholescintigraphy (87.4%, CL 76–94%) was significantly greater than US (61.6%, CL 44–77%), while the specificity of US (82%, CL 65–92%) was significantly higher than cholescintigraphy (68%, CL 47–84%). Conclusion Recent data suggests that CT may have a higher sensitivity than US for diagnosing acute cholecystitis, with similar specificity. Cholescintigraphy remains a highly sensitive modality with lower specificity than previously reported. MRI remains under studied, but with promising results.
- 20 November 2023
- Published by Springer Nature in Abdominal Radiology
- Vol. 49 (2) , 384-398
A meta-analysis of the performance of ultrasound, hepatobiliary scintigraphy, CT and MRI in the diagnosis of acute cholecystitis
Purpose To evaluate the recently reported relative diagnostic accuracy of US, CT, MRI, and cholescintigraphy for diagnosing acute cholecystitis. Methods 2 radiologists independently performed systematic electronic searches for articles published between 2000 and 2021 and applied inclusion/exclusion criteria. 2 different radiologists extracted data from the articles and scored each with a methodological quality tool. Pooled estimates of sensitivity and specificity were calculated with a bivariate linear mixed model. A second analysis made head-to-head comparisons (US vs. CT, US vs. cholescintigraphy). Factors were also analyzed for potential confounding effects on diagnostic accuracy. Results Of 6121 initial titles, 22 were included. The prevalence of cholecystitis varied widely across studies (9.4–98%). Pooled sensitivity and specificity estimates were 69% (confidence limit [CL] 62–76%) and 79% (CL 71–86%) for US, 91% (CL 86–94%) and 63% (CL 51–74%) for cholescintigraphy, 78% (CL 69–84%) and 81% (CL 71–88%) for CT, and 91% (CL 78–97%) and 93% (CL 70–99%) for MRI. Regarding head-to-head comparisons, the sensitivity of CT (87.6%, CL 70–96%) was significantly higher than US (66.8%, CL 43–84%), while specificities (81.7% with CL 54–95% for US, 91.9% with CL 67–99% for CT) were similar. The sensitivity of cholescintigraphy (87.4%, CL 76–94%) was significantly greater than US (61.6%, CL 44–77%), while the specificity of US (82%, CL 65–92%) was significantly higher than cholescintigraphy (68%, CL 47–84%). Conclusion Recent data suggests that CT may have a higher sensitivity than US for diagnosing acute cholecystitis, with similar specificity. Cholescintigraphy remains a highly sensitive modality with lower specificity than previously reported. MRI remains under studied, but with promising results.
- 22 October 2021
- Published by Springer Nature in Abdominal Radiology
- Vol. 47 (1) , 184-195
The imaging diagnosis of cholecystitis in the adult ED: a comparative multi-reader, multivariable analysis of CT and US image features
Purpose The purposes of this study are (1) to utilize multivariable logistic regression in order to evaluate which image feature combination is most predictive in the diagnosis of cholecystitis for computed tomography (CT) and ultrasound (US) in adult ED patients and (2) to use these results to compare the accuracy of CT and US. Methods For RUQ pain patients undergoing US and CT at the same visit, multiple image features were evaluated independently by 2 radiologists blinded to additional data. Inter-reader variability was measured with the Kappa statistic. Sonographic Murphy’s sign (SMS) information was obtained from original reports. Multivariable logistic regression was utilized to develop optimal predictive models for each modality. For US, models with/without SMS were compared to establish its relative value. Results 446 patients met inclusion criteria. For CT, the combination of cholelithiasis, short-axis gallbladder diameter > 3 cm, pericholecystic fluid or inflammation, and mural thickening > 3 mm provided the optimal model for both readers. For US, the optimal model included cholelithiasis, short-axis diameter > 3 cm, mural heterogeneity/striation, and sludge/debris for both readers. Kappa = 0.79–0.96 for included image features. For both readers, CT and US models had equivalent diagnostic performances; the SMS did not contribute significantly to US models. Conclusion For a diagnosis of cholecystitis in the ED, (1) the optimal image feature combination for CT is cholelithiasis, short-axis diameter > 3 cm, pericholecystic fluid or inflammation, mural thickening > 3 mm; and cholelithiasis, short-axis diameter > 3 cm, mural heterogeneity/striation, sludge/debris for US; (2) CT and US have equivalent diagnostic performance; (3) inter-reader reliability is substantial to excellent for utilized image features; (4) the SMS does not affect US model accuracy. Graphic abstract
- 22 October 2021
- Published by Springer Nature in Abdominal Radiology
- Vol. 47 (1) , 184-195
The imaging diagnosis of cholecystitis in the adult ED: a comparative multi-reader, multivariable analysis of CT and US image features
Purpose The purposes of this study are (1) to utilize multivariable logistic regression in order to evaluate which image feature combination is most predictive in the diagnosis of cholecystitis for computed tomography (CT) and ultrasound (US) in adult ED patients and (2) to use these results to compare the accuracy of CT and US. Methods For RUQ pain patients undergoing US and CT at the same visit, multiple image features were evaluated independently by 2 radiologists blinded to additional data. Inter-reader variability was measured with the Kappa statistic. Sonographic Murphy’s sign (SMS) information was obtained from original reports. Multivariable logistic regression was utilized to develop optimal predictive models for each modality. For US, models with/without SMS were compared to establish its relative value. Results 446 patients met inclusion criteria. For CT, the combination of cholelithiasis, short-axis gallbladder diameter > 3 cm, pericholecystic fluid or inflammation, and mural thickening > 3 mm provided the optimal model for both readers. For US, the optimal model included cholelithiasis, short-axis diameter > 3 cm, mural heterogeneity/striation, and sludge/debris for both readers. Kappa = 0.79–0.96 for included image features. For both readers, CT and US models had equivalent diagnostic performances; the SMS did not contribute significantly to US models. Conclusion For a diagnosis of cholecystitis in the ED, (1) the optimal image feature combination for CT is cholelithiasis, short-axis diameter > 3 cm, pericholecystic fluid or inflammation, mural thickening > 3 mm; and cholelithiasis, short-axis diameter > 3 cm, mural heterogeneity/striation, sludge/debris for US; (2) CT and US have equivalent diagnostic performance; (3) inter-reader reliability is substantial to excellent for utilized image features; (4) the SMS does not affect US model accuracy. Graphic abstract
- 1 April 2021
- Published by Elsevier in Seminars in Roentgenology
- Vol. 56 (2) , 186-200
Mucin-Containing Rectal Cancer: A Review of Unique Imaging, Pathology, and Therapeutic Response Features
- 1 April 2021
- Published by Elsevier in Seminars in Roentgenology
- Vol. 56 (2) , 186-200
Mucin-Containing Rectal Cancer: A Review of Unique Imaging, Pathology, and Therapeutic Response Features
- 22 August 2019
- Published by Springer Nature in Abdominal Radiology
- Vol. 44 (12) , 3935-3949
Multimodality imaging of the male urethra: trauma, infection, neoplasm, and common surgical repairs
The aim of this article is to describe the indications and proper technique for RUG and MRI, their respective image findings in various disease states, and the common surgical techniques and imaging strategies employed for stricture correction.
- 22 August 2019
- Published by Springer Nature in Abdominal Radiology
- Vol. 44 (12) , 3935-3949
Multimodality imaging of the male urethra: trauma, infection, neoplasm, and common surgical repairs
The aim of this article is to describe the indications and proper technique for RUG and MRI, their respective image findings in various disease states, and the common surgical techniques and imaging strategies employed for stricture correction.
- 30 January 2013
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 36 (5) , 1329-1335
Renal Function Outcomes for Multifocal Renal Neoplasms Managed by Radiofrequency Ablation
To evaluate renal function changes related to radiofrequency ablation (RFA) for the treatment of multifocal renal neoplasms. This is an institutional review board-approved, Health Insurance Portability and Accountability Act compliant retrospective study of all patients treated with computed tomography guided RFA for multifocal renal neoplasms at one institution. Fifty-seven subjects, mean age 70 (range 37-88) years, underwent RFA of 169 renal neoplasms (average size 2.0 cm). Subjects had between 2 and 8 (mean 2.96) neoplasms ablated. Estimated glomerular filtration rate (eGFR) was measured before and after RFA. Complications related to RFA were recorded. eGFR decreased on average of 4.4 % per tumor treated and 6.7 % per ablation session (average 1.76 tumors treated per session). For subjects with the largest neoplasm measuring >3 cm, eGFR decreased an average of 14.5 % during the course of their treatment. If the largest neoplasm measured 2-3 cm, eGFR decreased an average of 7.7 %, and if the largest neoplasm measured <2 cm, eGFR decreased an average of 3.8 %. Subjects with reduced baseline renal function were more likely to have a greater decline in eGFR after RFA. There was a minor complication rate of 6.3 % (6 of 96 sessions), none of which required treatment, and a major complication rate of 4.2 % (4 of 96 sessions). RFA for the treatment of multifocal renal neoplasms results in mild decline of renal function.
- 30 January 2013
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 36 (5) , 1329-1335
Renal Function Outcomes for Multifocal Renal Neoplasms Managed by Radiofrequency Ablation
To evaluate renal function changes related to radiofrequency ablation (RFA) for the treatment of multifocal renal neoplasms. This is an institutional review board-approved, Health Insurance Portability and Accountability Act compliant retrospective study of all patients treated with computed tomography guided RFA for multifocal renal neoplasms at one institution. Fifty-seven subjects, mean age 70 (range 37-88) years, underwent RFA of 169 renal neoplasms (average size 2.0 cm). Subjects had between 2 and 8 (mean 2.96) neoplasms ablated. Estimated glomerular filtration rate (eGFR) was measured before and after RFA. Complications related to RFA were recorded. eGFR decreased on average of 4.4 % per tumor treated and 6.7 % per ablation session (average 1.76 tumors treated per session). For subjects with the largest neoplasm measuring >3 cm, eGFR decreased an average of 14.5 % during the course of their treatment. If the largest neoplasm measured 2-3 cm, eGFR decreased an average of 7.7 %, and if the largest neoplasm measured <2 cm, eGFR decreased an average of 3.8 %. Subjects with reduced baseline renal function were more likely to have a greater decline in eGFR after RFA. There was a minor complication rate of 6.3 % (6 of 96 sessions), none of which required treatment, and a major complication rate of 4.2 % (4 of 96 sessions). RFA for the treatment of multifocal renal neoplasms results in mild decline of renal function.
- 1 January 2013
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 37 (1) , 29-36
Contrast-Enhanced Magnetic Resonance Urography at 3T
Objective The objective of this study was to assess the feasibility of performing diagnostic-quality contrast-enhanced excretory magnetic resonance urography (eMRU) at 3T, examining both image quality and diagnostic accuracy for a range of urinary tract abnormalities. Methods The diuretic-enhanced 3T eMRUs of 37 patients were reviewed to assess for the diagnostic conspicuity of urinary tract abnormalities, extent of urinary tract visualization on excretory images, and presence and severity of image artifacts. Results Excretory images allowed greater than 75% visualization in 90.8% of renal collecting systems, 90.8% of ureters, and 82.3% of bladders. Common artifacts included susceptibility (21.3%), contrast mixing (21.3%), patient motion (20.4%), signal inhomogeneity (19.4%), and peristaltic motion (17.6%). Severe artifacts occurred in 21.6% of studies. Five of 8 urothelial neoplasms were detected, with 1 false-positive lesion in the bladder. Urolithiasis was correctly diagnosed in 7 of 9 patients. Conclusions Although image artifacts can hamper eMRU at 3T, initial results are promising for evaluation of the urothelium.
- 1 January 2013
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 37 (1) , 29-36
Contrast-Enhanced Magnetic Resonance Urography at 3T
Objective The objective of this study was to assess the feasibility of performing diagnostic-quality contrast-enhanced excretory magnetic resonance urography (eMRU) at 3T, examining both image quality and diagnostic accuracy for a range of urinary tract abnormalities. Methods The diuretic-enhanced 3T eMRUs of 37 patients were reviewed to assess for the diagnostic conspicuity of urinary tract abnormalities, extent of urinary tract visualization on excretory images, and presence and severity of image artifacts. Results Excretory images allowed greater than 75% visualization in 90.8% of renal collecting systems, 90.8% of ureters, and 82.3% of bladders. Common artifacts included susceptibility (21.3%), contrast mixing (21.3%), patient motion (20.4%), signal inhomogeneity (19.4%), and peristaltic motion (17.6%). Severe artifacts occurred in 21.6% of studies. Five of 8 urothelial neoplasms were detected, with 1 false-positive lesion in the bladder. Urolithiasis was correctly diagnosed in 7 of 9 patients. Conclusions Although image artifacts can hamper eMRU at 3T, initial results are promising for evaluation of the urothelium.
- 1 January 2013
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 37 (6) , 843
Introductory Statement
- 1 January 2013
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 37 (6) , 843
Introductory Statement