Kerstin Persson Waye
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Kerstin Persson Waye has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Erica E. Ryherd
Woodruff School of Mech. Eng., Georgia Inst. of Technol., Atlanta, GA 30332-0405
6 shared publications - Henrik Møller
Acoustics, Aalborg University, Fredrik Bajers Vej 7 B5, 9220 Aalborg Ø, Denmark
3 shared publications Timothy Y. Hsu
George Woodruff School of Mech. Eng., Georgia Inst. of Technol., 771 Ferst Dr., Atlanta, GA 30332
3 shared publicationsErica Ryherd
Woodruff School of Mech. Eng., Georgia Inst. of Technol., Mech. Eng., Atlanta, GA 30332-0405
2 shared publicationsJeremy Ackerman
Dept. of Emergency Medicine, Emory Univ., Atlanta, GA
2 shared publicationsSteffen Pedersen
2 shared publications
Latest Publications
- 1 April 2015
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 137 (4_Suppleme) , 2247
Prescribing healthy hospital soundscapes
- 1 April 2015
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 137 (4_Suppleme) , 2247
Prescribing healthy hospital soundscapes
- 1 November 2013
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 134 (5_Suppleme) , 4041
The healthcare acoustics research team: Bridging the gap between architecture, engineering, and medicine
- 1 November 2013
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 134 (5_Suppleme) , 4041
The healthcare acoustics research team: Bridging the gap between architecture, engineering, and medicine
- 1 April 2011
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 129 (4_Suppleme) , 2635
Psychoacoustic measures and their relationship to patient physiology in an intensive care unit.
- 1 April 2011
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 129 (4_Suppleme) , 2635
Psychoacoustic measures and their relationship to patient physiology in an intensive care unit.
- 1 October 2010
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 128 (4_Suppleme) , 2285
Relating patient physiology to the hospital sound environment.
Sounds in hospital wards have previously been linked to physiologic changes in patients including sleep disturbance, variation in vital signs, and impaired pain management. However, relationships between sound measurements and variations in physiologic measures remain somewhat unclear. This presentation will discuss a pilot study that focuses on the relationships between acoustic measurements and patient physiology in a Swedish medical‐surgical intensive care unit. Sound measurements as well as physiologic measures including heart rate, oxygen saturation, respiratory rate, and blood pressure were recorded simultaneously for 24‐h periods in 18 patients. Several different analyzes were performed to assess the relationships between the acoustic results and the patients’ physiological measurements. The data demonstrated a statistically significant relationship between the recorded physiological responses and acoustic measurements. The results build upon previous results to further elucidate the relationships between hospital acoustics and patient physiological arousal. This paper is part of a series of studies that evaluates the hospital soundscape and the response of patients and staff members. [Work supported by ASA and Swedish FAS.]
- 1 October 2010
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 128 (4_Suppleme) , 2285
Relating patient physiology to the hospital sound environment.
Sounds in hospital wards have previously been linked to physiologic changes in patients including sleep disturbance, variation in vital signs, and impaired pain management. However, relationships between sound measurements and variations in physiologic measures remain somewhat unclear. This presentation will discuss a pilot study that focuses on the relationships between acoustic measurements and patient physiology in a Swedish medical‐surgical intensive care unit. Sound measurements as well as physiologic measures including heart rate, oxygen saturation, respiratory rate, and blood pressure were recorded simultaneously for 24‐h periods in 18 patients. Several different analyzes were performed to assess the relationships between the acoustic results and the patients’ physiological measurements. The data demonstrated a statistically significant relationship between the recorded physiological responses and acoustic measurements. The results build upon previous results to further elucidate the relationships between hospital acoustics and patient physiological arousal. This paper is part of a series of studies that evaluates the hospital soundscape and the response of patients and staff members. [Work supported by ASA and Swedish FAS.]
- 1 April 2009
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 125 (4_Suppleme) , 2685
Evaluating the intensive care unit soundscape.
- 1 April 2009
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 125 (4_Suppleme) , 2685
Evaluating the intensive care unit soundscape.
- 1 July 2008
- Published by Portico in Noise Notes
- Vol. 7 (3) , 3-26
Indoor Measurements of Noise at Low Frequencies - Problems and Solutions
- 1 July 2008
- Published by Portico in Noise Notes
- Vol. 7 (3) , 3-26
Indoor Measurements of Noise at Low Frequencies - Problems and Solutions
- 1 May 2008
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 123 (5_Suppleme) , 3193
Quantifying the noise environment: effects of the wearer's voice on body-mounted noise dosimeter measurements
The purpose of this project was to investigate the effects of the wearer's voice as a dominant sound source on body‐mounted noise dosimeters in medium‐level acoustic environments. Noise dosimeters provide a convenient method of quantifying an occupant's acoustical exposure. In recent years, interest in personal noise exposure has expanded beyond a necessary safety measure used in industrial settings to be used as a means of documenting a person's exposure to sound pressure levels in lower level environments like hospitals and schools. This study quantifies the contribution of the wearer's voice to the dosimeter measurement in sixteen different office conditions. Statistical analysis was used to determine the effects of the following experimental variables on the measured levels: 1) the type of room in which the measurement is taken, 2) the type of background noise present, 3) the level of background noise. Preliminary statistical results suggest significant main effects of the experimental variables with no significant interaction effects. The statistical effect of the subject's hearing level was also considered. The results of this study can improve the interpretation of dosimeter measurements in medium‐level environments and may provide further motivation for alternate methods of quantifying sound pressure levels associated with body‐mounted measurements.
- 1 May 2008
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 123 (5_Suppleme) , 3193
Quantifying the noise environment: effects of the wearer's voice on body-mounted noise dosimeter measurements
The purpose of this project was to investigate the effects of the wearer's voice as a dominant sound source on body‐mounted noise dosimeters in medium‐level acoustic environments. Noise dosimeters provide a convenient method of quantifying an occupant's acoustical exposure. In recent years, interest in personal noise exposure has expanded beyond a necessary safety measure used in industrial settings to be used as a means of documenting a person's exposure to sound pressure levels in lower level environments like hospitals and schools. This study quantifies the contribution of the wearer's voice to the dosimeter measurement in sixteen different office conditions. Statistical analysis was used to determine the effects of the following experimental variables on the measured levels: 1) the type of room in which the measurement is taken, 2) the type of background noise present, 3) the level of background noise. Preliminary statistical results suggest significant main effects of the experimental variables with no significant interaction effects. The statistical effect of the subject's hearing level was also considered. The results of this study can improve the interpretation of dosimeter measurements in medium‐level environments and may provide further motivation for alternate methods of quantifying sound pressure levels associated with body‐mounted measurements.
- 1 May 2008
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 123 (5_Suppleme) , 3193
Relating the hospital sound environment to occupant psychological and physiological response
Examining the relationship between specific acoustical characteristics of noise and occupant response is a fundamental step in determining the current hospital soundscape. Hospitals should be conducive to patient recovery and safety as well as employee health and productivity. Therefore, the sound environment that occupants are exposed to should be attended to from a health standpoint. Previous research on hospital patients has indicated negative effects of hospital sounds such as sleep disturbance, cardiovascular response, increased incidence of rehospitalization, extended hospital stay, and increased dosages of pain medication. There is some evidence that overall levels of hospital noise may impact staff mental efficiency, short‐term memory and stress. A series of studies are currently being conducted by the authors to evaluate the modern hospital soundscape and the associated psycho‐physiological responses of occupants, incorporating both quantitative and qualitative approaches. One phase in which detailed soundmeasurements, staff evaluations, and patient physiological measurements were conducted in a general intensive care unit will be highlighted, focusing also on methodological aspects related to physiological measurements. This phase also includes evaluation of patient ICU delirium, a condition that may negatively impact patient health and length of stay in the hospital. [Work supported by ASA and Swedish FAS].
- 1 May 2008
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 123 (5_Suppleme) , 3193
Relating the hospital sound environment to occupant psychological and physiological response
Examining the relationship between specific acoustical characteristics of noise and occupant response is a fundamental step in determining the current hospital soundscape. Hospitals should be conducive to patient recovery and safety as well as employee health and productivity. Therefore, the sound environment that occupants are exposed to should be attended to from a health standpoint. Previous research on hospital patients has indicated negative effects of hospital sounds such as sleep disturbance, cardiovascular response, increased incidence of rehospitalization, extended hospital stay, and increased dosages of pain medication. There is some evidence that overall levels of hospital noise may impact staff mental efficiency, short‐term memory and stress. A series of studies are currently being conducted by the authors to evaluate the modern hospital soundscape and the associated psycho‐physiological responses of occupants, incorporating both quantitative and qualitative approaches. One phase in which detailed soundmeasurements, staff evaluations, and patient physiological measurements were conducted in a general intensive care unit will be highlighted, focusing also on methodological aspects related to physiological measurements. This phase also includes evaluation of patient ICU delirium, a condition that may negatively impact patient health and length of stay in the hospital. [Work supported by ASA and Swedish FAS].
- 1 May 2008
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 123 (5_Suppleme) , 3164
Effect of recording/playback technique and experimental method on assessments of noise
- 1 May 2008
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 123 (5_Suppleme) , 3164
Effect of recording/playback technique and experimental method on assessments of noise
- 1 May 2008
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 123 (5_Suppleme) , 3139
Measuring low-frequency noise indoors
At low frequencies, the sound pressure level may vary 20‐30 dB in a room due to standing waves. For assessment of annoyance, mainly areas with the highest occurring levels are relevant, since persons present in such areas are not helped by the existence of lower levels in other areas. The level that is exceeded in 10% of the volume of a room L 10 is proposed as a rational and objective target for a measurement method. In Sweden and Denmark rules exist for measuring low‐frequency noise indoors. The performance of these procedures was investigated in three rooms. The results from the Swedish method were close to the L 10 target, but, due to a doubtful use of C‐weighting in the scanning, it may give too low results in case of complex sounds. The Danish method was found to have a high risk of giving results substantially below the target, unless complainants can precisely appoint measurement positions, where the sound is loudest/most annoying ‐ which they often cannot. An alternative method using measurements in four three‐dimensional corners of the room is proposed. This easy and straightforward method seems to give reliable results close to the proposed target.
- 1 May 2008
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 123 (5_Suppleme) , 3139
Measuring low-frequency noise indoors
At low frequencies, the sound pressure level may vary 20‐30 dB in a room due to standing waves. For assessment of annoyance, mainly areas with the highest occurring levels are relevant, since persons present in such areas are not helped by the existence of lower levels in other areas. The level that is exceeded in 10% of the volume of a room L 10 is proposed as a rational and objective target for a measurement method. In Sweden and Denmark rules exist for measuring low‐frequency noise indoors. The performance of these procedures was investigated in three rooms. The results from the Swedish method were close to the L 10 target, but, due to a doubtful use of C‐weighting in the scanning, it may give too low results in case of complex sounds. The Danish method was found to have a high risk of giving results substantially below the target, unless complainants can precisely appoint measurement positions, where the sound is loudest/most annoying ‐ which they often cannot. An alternative method using measurements in four three‐dimensional corners of the room is proposed. This easy and straightforward method seems to give reliable results close to the proposed target.