Ernest J. Feleppa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ernest J. Feleppa has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
Andrew Kalisz
Biomedical Engineering Laboratories Riverside Research Institute 156 William Street New York, NY 10038
4 shared publications- Jeffrey A. Ketterling
Department of Radiology, Weill Cornell Medicine, New York, NY, USA
3 shared publications Stella Urban
Biomedical Engineering Laboratories Riverside Research Institute 156 William Street New York, NY 10038
3 shared publicationsCheng-Shie Wuu
2 shared publicationsChristopher R. Porter
Department of Urology Virginia Mason Medical Center Seattle, WA 98101
2 shared publications- Jonathan Mamou
Riverside Res. Inst., New York, NY
2 shared publications
Latest Publications
- 1 February 2014
- Published by American Society of Clinical Oncology (ASCO) in Journal of Clinical Oncology
- Vol. 32 (4_suppl) , 246
Prospective phase I/II trial of dose-painting prostate brachytherapy guided by cancer-specific ultrasound-based tissue-type imaging (TTI).
246 Background: Standard treatments treat the entire prostate gland uniformly, while focal treatments target only the dominant tumor. We propose an alternative approach wherein tumor areas are treated with an escalated dose of radiation while the remainder of the prostate with dose de-escalation. Tissue-type images (TTIs), which identify intraprostatic tumors via ultrasound spectral analysis, were used to identify tumors. Methods: 14 low risk patients were enrolled. TTIs and standard B-mode ultrasound images were generated and fused intraoperatively. Based on TTIs, plans were developed to deliver 200% prescription dose to the tumors and 100% to the prostate. Doses above 100% to non-tumor regions were minimized and standard normal tissue constraints were respected. Results: 12 patients were successfully treated. Technical problems occurred in the first patient and another received a standard implant due to discordance of TTIs with MRI and biopsy findings. One patient passed away soon after the procedure of unrelated cause. A total of 28 tumors were identified in these 12 patients (median 2 tumors/patient, range 1-4). Mean tumor volume was 0.72cc (range 0.03cc -4.07cc). Tumor dose was significantly higher in TTI-based plans, with mean tumor V200%: TTI vs. standard 97% vs. 48%, p
- 1 February 2014
- Published by American Society of Clinical Oncology (ASCO) in Journal of Clinical Oncology
- Vol. 32 (4_suppl) , 246
Prospective phase I/II trial of dose-painting prostate brachytherapy guided by cancer-specific ultrasound-based tissue-type imaging (TTI).
246 Background: Standard treatments treat the entire prostate gland uniformly, while focal treatments target only the dominant tumor. We propose an alternative approach wherein tumor areas are treated with an escalated dose of radiation while the remainder of the prostate with dose de-escalation. Tissue-type images (TTIs), which identify intraprostatic tumors via ultrasound spectral analysis, were used to identify tumors. Methods: 14 low risk patients were enrolled. TTIs and standard B-mode ultrasound images were generated and fused intraoperatively. Based on TTIs, plans were developed to deliver 200% prescription dose to the tumors and 100% to the prostate. Doses above 100% to non-tumor regions were minimized and standard normal tissue constraints were respected. Results: 12 patients were successfully treated. Technical problems occurred in the first patient and another received a standard implant due to discordance of TTIs with MRI and biopsy findings. One patient passed away soon after the procedure of unrelated cause. A total of 28 tumors were identified in these 12 patients (median 2 tumors/patient, range 1-4). Mean tumor volume was 0.72cc (range 0.03cc -4.07cc). Tumor dose was significantly higher in TTI-based plans, with mean tumor V200%: TTI vs. standard 97% vs. 48%, p
- 23 February 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8320, 832016
Modulus reconstruction from prostate ultrasound images using finite element modeling
In medical diagnosis, use of elastography is becoming increasingly more useful. However, treatments usually assume a planar compression applied to tissue surfaces and measure the deformation. The stress distribution is relatively uniform close to the surface when using a large, flat compressor but it diverges gradually along tissue depth. Generally in prostate elastography, the transrectal probes used for scanning and compression are cylindrical side-fire or rounded end-fire probes, and the force is applied through the rectal wall. These make it very difficult to detect cancer in prostate, since the rounded contact surfaces exaggerate the non-uniformity of the applied stress, especially for the distal, anterior prostate. We have developed a preliminary 2D Finite Element Model (FEM) to simulate prostate deformation in elastography. The model includes a homogeneous prostate with a stiffer tumor in the proximal, posterior region of the gland. A force is applied to the rectal wall to deform the prostate, strain and stress distributions can be computed from the resultant displacements. Then, we assume the displacements as boundary condition and reconstruct the modulus distribution (inverse problem) using linear perturbation method. FEM simulation shows that strain and strain contrast (of the lesion) decrease very rapidly with increasing depth and lateral distance. Therefore, lesions would not be clearly visible if located far away from the probe. However, the reconstructed modulus image can better depict relatively stiff lesion wherever the lesion is located.
- 23 February 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8320, 832016
Modulus reconstruction from prostate ultrasound images using finite element modeling
In medical diagnosis, use of elastography is becoming increasingly more useful. However, treatments usually assume a planar compression applied to tissue surfaces and measure the deformation. The stress distribution is relatively uniform close to the surface when using a large, flat compressor but it diverges gradually along tissue depth. Generally in prostate elastography, the transrectal probes used for scanning and compression are cylindrical side-fire or rounded end-fire probes, and the force is applied through the rectal wall. These make it very difficult to detect cancer in prostate, since the rounded contact surfaces exaggerate the non-uniformity of the applied stress, especially for the distal, anterior prostate. We have developed a preliminary 2D Finite Element Model (FEM) to simulate prostate deformation in elastography. The model includes a homogeneous prostate with a stiffer tumor in the proximal, posterior region of the gland. A force is applied to the rectal wall to deform the prostate, strain and stress distributions can be computed from the resultant displacements. Then, we assume the displacements as boundary condition and reconstruct the modulus distribution (inverse problem) using linear perturbation method. FEM simulation shows that strain and strain contrast (of the lesion) decrease very rapidly with increasing depth and lateral distance. Therefore, lesions would not be clearly visible if located far away from the probe. However, the reconstructed modulus image can better depict relatively stiff lesion wherever the lesion is located.
- 3 June 2011
- Published by Springer Nature
- p. 17-27
Ultrasonic Detection of Metastases in Dissected Lymph Nodes of Cancer Patients
- 3 June 2011
- Published by Springer Nature
- p. 17-27
Ultrasonic Detection of Metastases in Dissected Lymph Nodes of Cancer Patients
- 11 November 2008
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 124 (6) , EL347-EL352
Angle-dependent ultrasonic detection and imaging of two types of brachytherapy seeds using singular spectrum analysis
Brachytherapy to treat prostate cancer uses transrectal ultrasound to guide implantation of titanium-shelled radioactive seeds. Transperitoneal implantation allows errors in placement that cause suboptimal dosimetry. Conventional ultrasound cannot reliably image implanted seeds; therefore, seed misplacements cannot be corrected in the operating room. Previously, an algorithm based on singular spectrum analysis was shown to image palladium seeds better than B-mode ultrasound could. The algorithm is now applied to imaging an iodine seed in gel and in beef tissue as a function of seed angle relative to the incident ultrasound. Results indicate that both seed types are imaged reliably by the algorithm.
- 11 November 2008
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 124 (6) , EL347-EL352
Angle-dependent ultrasonic detection and imaging of two types of brachytherapy seeds using singular spectrum analysis
Brachytherapy to treat prostate cancer uses transrectal ultrasound to guide implantation of titanium-shelled radioactive seeds. Transperitoneal implantation allows errors in placement that cause suboptimal dosimetry. Conventional ultrasound cannot reliably image implanted seeds; therefore, seed misplacements cannot be corrected in the operating room. Previously, an algorithm based on singular spectrum analysis was shown to image palladium seeds better than B-mode ultrasound could. The algorithm is now applied to imaging an iodine seed in gel and in beef tissue as a function of seed angle relative to the incident ultrasound. Results indicate that both seed types are imaged reliably by the algorithm.
- 4 November 2008
- Published by SAGE Publications in Cancer Biomarkers
- Vol. 4 (4-5) , 201-212
Ultrasonic tissue-type imaging of the prostate: Implications for biopsy and treatment guidance
Improved means of imaging prostate cancer would enable more-effective biopsy and treatment guidance and potentially would provide a reliable means of monitoring non-surgical therapy. Current, commonly used, conventional means of imaging the prostate
- 4 November 2008
- Published by SAGE Publications in Cancer Biomarkers
- Vol. 4 (4-5) , 201-212
Ultrasonic tissue-type imaging of the prostate: Implications for biopsy and treatment guidance
Improved means of imaging prostate cancer would enable more-effective biopsy and treatment guidance and potentially would provide a reliable means of monitoring non-surgical therapy. Current, commonly used, conventional means of imaging the prostate
- 1 May 2008
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 123 (5_Suppleme) , 3001
High-frequency quantitative ultrasound imaging methods for human lymph nodes characterization ex vivo
High‐frequency (>15 MHz, i.e., wavelength <100 μm) ultrasound has the potential to characterize biological tissues quantitatively at the microscopic level. In this study, quantitative ultrasound (QUS) methods were developed to evaluate freshly excised human lymph nodes from patients with possible metastatic cancer. The objectives were to improve detection of small but clinically significant lymph‐node metastases that often are missed during routine histological evaluation. Three‐dimensional (3D) ultrasounddata acquisition was conducted on freshly excised nodes using a spherically‐focused transducer with a center frequency of 21 MHz. Average scatterer sizes and acoustic concentrations were estimated using QUS methods with a Gaussian scatteringmodel over a bandwidth extending from 11 to 27 MHz. Strategies were developed to recover lymph‐node orientation and size after histological sectioning to allow for spatially matching QUS estimates to histology. The signal‐ and image‐processing aspects of QUS estimation are presented and the preliminary results are shown that demonstrate our ability to acquire 3D ultrasound and histological data, to co‐register them spatially, and to obtain scatterer‐size and acoustic‐concentration estimates for specific tissue types (cancer versus non‐cancer) within the nodes. In future studies, these QUS estimates will be used to identify histologically difficult‐to‐detect micrometastases in lymph‐nodes. [Supported by NIH R01CA100183.]
- 1 May 2008
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 123 (5_Suppleme) , 3001
High-frequency quantitative ultrasound imaging methods for human lymph nodes characterization ex vivo
High‐frequency (>15 MHz, i.e., wavelength <100 μm) ultrasound has the potential to characterize biological tissues quantitatively at the microscopic level. In this study, quantitative ultrasound (QUS) methods were developed to evaluate freshly excised human lymph nodes from patients with possible metastatic cancer. The objectives were to improve detection of small but clinically significant lymph‐node metastases that often are missed during routine histological evaluation. Three‐dimensional (3D) ultrasounddata acquisition was conducted on freshly excised nodes using a spherically‐focused transducer with a center frequency of 21 MHz. Average scatterer sizes and acoustic concentrations were estimated using QUS methods with a Gaussian scatteringmodel over a bandwidth extending from 11 to 27 MHz. Strategies were developed to recover lymph‐node orientation and size after histological sectioning to allow for spatially matching QUS estimates to histology. The signal‐ and image‐processing aspects of QUS estimation are presented and the preliminary results are shown that demonstrate our ability to acquire 3D ultrasound and histological data, to co‐register them spatially, and to obtain scatterer‐size and acoustic‐concentration estimates for specific tissue types (cancer versus non‐cancer) within the nodes. In future studies, these QUS estimates will be used to identify histologically difficult‐to‐detect micrometastases in lymph‐nodes. [Supported by NIH R01CA100183.]
- Open Access
- 1 July 2004
- Published by SAGE Publications in Ultrasonic Imaging
- Vol. 26 (3) , 163-172
Recent Developments in Tissue-Type Imaging (TTI) for Planning and Monitoring Treatment of Prostate Cancer
Because current methods of imaging prostate cancer are inadequate, biopsies cannot be effectively guided and treatment cannot be effectively planned and targeted. Therefore, our research is aimed at ultrasonically characterizing cancerous prostate tissue so that we can image it more effectively and thereby provide improved means of detecting, treating and monitoring prostate cancer. We base our characterization methods on spectrum analysis of radiofrequency (rf) echo signals combined with clinical variables such as prostate-specific antigen (PSA). Tissue typing using these parameters is performed by artificial neural networks. We employed and evaluated different approaches to data partitioning into training, validation, and test sets and different neural network configuration options. In this manner, we sought to determine what neural network configuration is optimal for these data and also to assess possible bias that might exist due to correlations among different data entries among the data for a given patient. The classification efficacy of each neural network configuration and data-partitioning method was measured using relative-operating-characteristic (ROC) methods. Neural network classification based on spectral parameters combined with clinical data generally produced ROC-curve areas of 0.80 compared to curve areas of 0.64 for conventional transrectal ultrasound imaging combined with clinical data. We then used the optimal neural network configuration to generate lookup tables that translate local spectral parameter values and global clinical-variable values into pixel values in tissue-type images (TTIs). TTIs continue to show cancerous regions successfully, and may prove to be particularly useful clinically in combination with other ultrasonic and nonultrasonic methods, e.g., magnetic-resonance spectroscopy.
- 1 July 2004
- Published by SAGE Publications in Ultrasonic Imaging
- Vol. 26 (3) , 163-172
Open AccessRecent Developments in Tissue-Type Imaging (TTI) for Planning and Monitoring Treatment of Prostate Cancer
Because current methods of imaging prostate cancer are inadequate, biopsies cannot be effectively guided and treatment cannot be effectively planned and targeted. Therefore, our research is aimed at ultrasonically characterizing cancerous prostate tissue so that we can image it more effectively and thereby provide improved means of detecting, treating and monitoring prostate cancer. We base our characterization methods on spectrum analysis of radiofrequency (rf) echo signals combined with clinical variables such as prostate-specific antigen (PSA). Tissue typing using these parameters is performed by artificial neural networks. We employed and evaluated different approaches to data partitioning into training, validation, and test sets and different neural network configuration options. In this manner, we sought to determine what neural network configuration is optimal for these data and also to assess possible bias that might exist due to correlations among different data entries among the data for a given patient. The classification efficacy of each neural network configuration and data-partitioning method was measured using relative-operating-characteristic (ROC) methods. Neural network classification based on spectral parameters combined with clinical data generally produced ROC-curve areas of 0.80 compared to curve areas of 0.64 for conventional transrectal ultrasound imaging combined with clinical data. We then used the optimal neural network configuration to generate lookup tables that translate local spectral parameter values and global clinical-variable values into pixel values in tissue-type images (TTIs). TTIs continue to show cancerous regions successfully, and may prove to be particularly useful clinically in combination with other ultrasonic and nonultrasonic methods, e.g., magnetic-resonance spectroscopy.
- 1 May 2004
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 115 (5_Suppleme) , 2410
Novel ultrasonic methods of imaging interstitially implanted brachytherapy seeds
- 1 May 2004
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 115 (5_Suppleme) , 2410
Novel ultrasonic methods of imaging interstitially implanted brachytherapy seeds
- 1 January 2002
- Published by Elsevier in Brachytherapy
- Vol. 1 (1) , 48-53
Ultrasonic spectrum-analysis and neural-network classification as a basis for ultrasonic imaging to target brachytherapy of prostate cancer
- 1 January 2002
- Published by Elsevier in Brachytherapy
- Vol. 1 (1) , 48-53
Ultrasonic spectrum-analysis and neural-network classification as a basis for ultrasonic imaging to target brachytherapy of prostate cancer