Jeff Powers
Research Subjects
Jeff Powers has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Christophoros Mannaris
Dept. of Mech. and Manufacturing Eng., Univ. of Cyprus, 75 Kallipoleos, 1678 Nicosia, Cyprus
1 shared publication Frederick Kremkau
Wake Forest University, Winston-Salem, NC 27106, USA
1 shared publicationMatthew Bruce
1 shared publication- Matthew Bruce
Center for Industrial and Medical Ultrasound, University of Washington Applied Physics Lab , Seattle, Washington
1 shared publication - Michalakis A. Averkiou
University of Cyprus/Dept. of Mech. Engineering, 75 Kallipoleos Str., 1678 Nicosia, Cyprus
1 shared publication Michalakis Averkiou
1 shared publication
Latest Publications
- 18 May 2011
- Published by The Royal Society in Interface Focus
- Vol. 1 (4) , 477-489
Medical ultrasound systems
Medical ultrasound imaging has advanced dramatically since its introduction only a few decades ago. This paper provides a short historical background, and then briefly describes many of the system features and concepts required in a modern commercial ultrasound system. The topics addressed include array beam formation, steering and focusing; array and matrix transducers; echo image formation; tissue harmonic imaging; speckle reduction through frequency and spatial compounding, and image processing; tissue aberration; Doppler flow detection; and system architectures. It then describes some of the more practical aspects of ultrasound system design necessary to be taken into account for today's marketplace. It finally discusses the recent explosion of portable and handheld devices and their potential to expand the clinical footprint of ultrasound into regions of the world where medical care is practically non-existent. Throughout the article reference is made to ways in which ultrasound imaging has benefited from advances in the commercial electronics industry. It is meant to be an overview of the field as an introduction to other more detailed papers in this special issue.
- 18 May 2011
- Published by The Royal Society in Interface Focus
- Vol. 1 (4) , 477-489
Medical ultrasound systems
Medical ultrasound imaging has advanced dramatically since its introduction only a few decades ago. This paper provides a short historical background, and then briefly describes many of the system features and concepts required in a modern commercial ultrasound system. The topics addressed include array beam formation, steering and focusing; array and matrix transducers; echo image formation; tissue harmonic imaging; speckle reduction through frequency and spatial compounding, and image processing; tissue aberration; Doppler flow detection; and system architectures. It then describes some of the more practical aspects of ultrasound system design necessary to be taken into account for today's marketplace. It finally discusses the recent explosion of portable and handheld devices and their potential to expand the clinical footprint of ultrasound into regions of the world where medical care is practically non-existent. Throughout the article reference is made to ways in which ultrasound imaging has benefited from advances in the commercial electronics industry. It is meant to be an overview of the field as an introduction to other more detailed papers in this special issue.
- 1 April 2009
- Published by S. Karger AG in Cerebrovascular Diseases
- Vol. 27 (Suppl. 2) , 14-24
Principles of Cerebral Ultrasound Contrast Imaging
Ultrasound contrast is gaining acceptance worldwide as an adjunct to conventional ultrasound imaging. It has clinical applications as diverse as liver disease detection and characterization, myocardial perfusion and wall motion studies, and cerebral vascularity and perfusion imaging. This paper will focus on imaging techniques used for transcranial ultrasound contrast imaging. The interaction of ultrasound with the microbubbles in the contrast agent is complex and nonlinear. This has led to the development of a variety of imaging modes to improve contrast detection over noncontrast optimized modes. This article presents several of these imaging methods in such a way as to help clinical and research users of ultrasound contrast understand this rapidly developing field.
- 1 April 2009
- Published by S. Karger AG in Cerebrovascular Diseases
- Vol. 27 (Suppl. 2) , 14-24
Principles of Cerebral Ultrasound Contrast Imaging
Ultrasound contrast is gaining acceptance worldwide as an adjunct to conventional ultrasound imaging. It has clinical applications as diverse as liver disease detection and characterization, myocardial perfusion and wall motion studies, and cerebral vascularity and perfusion imaging. This paper will focus on imaging techniques used for transcranial ultrasound contrast imaging. The interaction of ultrasound with the microbubbles in the contrast agent is complex and nonlinear. This has led to the development of a variety of imaging modes to improve contrast detection over noncontrast optimized modes. This article presents several of these imaging methods in such a way as to help clinical and research users of ultrasound contrast understand this rapidly developing field.
- 1 May 2008
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 123 (5_Suppleme) , 3110
Nonlinear pulsing schemes for the detection of ultrasound contrast agents
Ultrasoundcontrast agents are used in cardiology for the assessment of myocardial perfusion and in radiology for the detection and characterization of tumors. One widely used approach of imagingcontrast agents is to use a low Mechanical Index (MI) nonlinear imaging technique to avoid bubble destruction and image both the macro‐ and micro‐circulation in real‐time. Various pulsing schemes are employed for the detection of nonlinear echoes from contrastmicrobubbles. The objective of this paper is to evaluate the various pulsing schemes for low MIimaging of contrastmicrobubbles and better understand their similarities and differences. The pulsing schemes considered are pulse inversion, power modulation, and their combination. Emphasis is placed on identifying whether nonlinearity due to propagation in tissue may be discriminated from nonlinearity due to scattering from bubbles. Bubble destruction (use of high MI) and tissue motion were not considered in this work. The evaluation of the different pulsing schemes was performed with numerical simulations from well established theoreticalmodels and experimental data from microbubbles in tissue phantoms and human tissues.
- 1 May 2008
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 123 (5_Suppleme) , 3110
Nonlinear pulsing schemes for the detection of ultrasound contrast agents
Ultrasoundcontrast agents are used in cardiology for the assessment of myocardial perfusion and in radiology for the detection and characterization of tumors. One widely used approach of imagingcontrast agents is to use a low Mechanical Index (MI) nonlinear imaging technique to avoid bubble destruction and image both the macro‐ and micro‐circulation in real‐time. Various pulsing schemes are employed for the detection of nonlinear echoes from contrastmicrobubbles. The objective of this paper is to evaluate the various pulsing schemes for low MIimaging of contrastmicrobubbles and better understand their similarities and differences. The pulsing schemes considered are pulse inversion, power modulation, and their combination. Emphasis is placed on identifying whether nonlinearity due to propagation in tissue may be discriminated from nonlinearity due to scattering from bubbles. Bubble destruction (use of high MI) and tissue motion were not considered in this work. The evaluation of the different pulsing schemes was performed with numerical simulations from well established theoreticalmodels and experimental data from microbubbles in tissue phantoms and human tissues.