Shiyang Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shiyang Li has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Wenwu Cao
Center of Acoustic Functional Materials and Applications, School of Functional Materials and Intelligent Engineering, Nanjing University, Suzhou 215163, China
4 shared publications Limei Zheng
Harbin Institute of Technology 2 Condensed Matter Science and Technology Institute Harbin 150080, China
3 shared publicationsJia Zheng
Shanghai Jiao Tong Univ, Sch Sensing Sci & Engn, Shanghai 200240, Peoples R China
2 shared publications- Ming Yang
Department of Instrument Science and Engineering, Shanghai Jiao Tong University, Shanghai, China
2 shared publications Wenhua Jiang
Materials Research Institute, Pennsylvania State University, University Park 2 , Pennsylvania 16802, USA
2 shared publicationsBin Wang
Shanghai Jiao Tong Univ, Dept Naval Architecture & Ocean Engn, Shanghai 200240, Peoples R China
1 shared publication
Latest Publications
- 28 November 2021
- Published by Springer Nature in Journal of Shanghai Jiaotong University (Science)
- p. 1-10
CFD-Aided Investigation of Combined Flow Conditioners for Gas Ultrasonic Flow Meter
- 28 November 2021
- Published by Springer Nature in Journal of Shanghai Jiaotong University (Science)
- p. 1-10
CFD-Aided Investigation of Combined Flow Conditioners for Gas Ultrasonic Flow Meter
- Open Access
Velocity Control of Traveling-Wave Ultrasonic Motors Based on Stator Vibration Amplitude
Nonlinearity and resonance frequency shift make it difficult to control the operation of the traveling-wave ultrasonic motors (TWUSMs) in a wide velocity and load range. In this paper, a velocity control scheme based on the stator vibration amplitude and the parallel resonance frequency (VCBVF) of TWUSMs is proposed. Then, the stator vibration amplitude (SVA) and parallel resonance frequency ( ) are detected by a transformer ratio-arm bridge. Based on the linear relationship between the velocity and the SVA of TWUSMs, the proposed scheme achieves the control of the mechanical loop and the electrical loop. The linear relationship between the velocity and the SVA makes the mechanical loop achieve the target velocity efficiently, according to the SVA, and the electrical loop could provide the target SVA quickly. Experimental results show that the response time of velocity is 3–4 ms under different load torques and the overshoot is less than 22%. In addition, the proposed scheme improves the efficiency of TWUSMs due to tracking. Due to directing the SVA control, the proposed scheme can heighten the velocity response and the load adaptability of TWUSMs, and promote the application of TWUSMs under various conditions.Open AccessVelocity Control of Traveling-Wave Ultrasonic Motors Based on Stator Vibration Amplitude
Nonlinearity and resonance frequency shift make it difficult to control the operation of the traveling-wave ultrasonic motors (TWUSMs) in a wide velocity and load range. In this paper, a velocity control scheme based on the stator vibration amplitude and the parallel resonance frequency (VCBVF) of TWUSMs is proposed. Then, the stator vibration amplitude (SVA) and parallel resonance frequency ( ) are detected by a transformer ratio-arm bridge. Based on the linear relationship between the velocity and the SVA of TWUSMs, the proposed scheme achieves the control of the mechanical loop and the electrical loop. The linear relationship between the velocity and the SVA makes the mechanical loop achieve the target velocity efficiently, according to the SVA, and the electrical loop could provide the target SVA quickly. Experimental results show that the response time of velocity is 3–4 ms under different load torques and the overshoot is less than 22%. In addition, the proposed scheme improves the efficiency of TWUSMs due to tracking. Due to directing the SVA control, the proposed scheme can heighten the velocity response and the load adaptability of TWUSMs, and promote the application of TWUSMs under various conditions. - 5 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 69 (6) , 2948-2958
Data Fusion Method and Probabilistic Pairing Approach in Elastic Constants Measurement by Resonance Ultrasound Spectroscopy
Resonant ultrasound spectroscopy (RUS) is a nondestructive technique for measuring the stiffness parameters of solid materials. Trying to achieve an improved automatic elastic coefficients measurement via RUS, this work proposes a data fusion method based on Bayesian formulation and a probabilistic pairing approach. Several sets of RUS data have been acquired by measuring a novel piezoelectric crystal Ca3NbAl0.5Ga0.5Si2O14 (CNAGS) with a self-designed RUS measurement system. In order to suppress the influence of the phenomenon of frequency shifting, missing and overlapping, a repeated measurement is executed to achieve the multiple measurement data fusion by using Bayesian formulation, and the posterior distribution of each parameter is estimated by reversible jump Markov chain Monte Carlo (RJMCMC) algorithm. Besides, an automatic probabilistic pairing method is proposed to solve the problem of frequency crossing so as to facilitate the frequency pairing process. The RUS measuring apparatus, the algorithm principle and the calculation process are illustrated systematically in this paper. The algorithm is tested and analyzed based on the measured RUS data and full sets of elastic coefficients of CNAGS specimen has been obtained in this work. Compared to the IEEE standard resonant method, the method proposed in thiswork can accomplish the characterization within a shorter time and the relative error of the results is less than 2%.
- 5 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 69 (6) , 2948-2958
Data Fusion Method and Probabilistic Pairing Approach in Elastic Constants Measurement by Resonance Ultrasound Spectroscopy
Resonant ultrasound spectroscopy (RUS) is a nondestructive technique for measuring the stiffness parameters of solid materials. Trying to achieve an improved automatic elastic coefficients measurement via RUS, this work proposes a data fusion method based on Bayesian formulation and a probabilistic pairing approach. Several sets of RUS data have been acquired by measuring a novel piezoelectric crystal Ca3NbAl0.5Ga0.5Si2O14 (CNAGS) with a self-designed RUS measurement system. In order to suppress the influence of the phenomenon of frequency shifting, missing and overlapping, a repeated measurement is executed to achieve the multiple measurement data fusion by using Bayesian formulation, and the posterior distribution of each parameter is estimated by reversible jump Markov chain Monte Carlo (RJMCMC) algorithm. Besides, an automatic probabilistic pairing method is proposed to solve the problem of frequency crossing so as to facilitate the frequency pairing process. The RUS measuring apparatus, the algorithm principle and the calculation process are illustrated systematically in this paper. The algorithm is tested and analyzed based on the measured RUS data and full sets of elastic coefficients of CNAGS specimen has been obtained in this work. Compared to the IEEE standard resonant method, the method proposed in thiswork can accomplish the characterization within a shorter time and the relative error of the results is less than 2%.
- 6 June 2016
- Published by AIP Publishing in Applied Physics Letters
- Vol. 108 (23) , 232901
Switching 70Pb(Mg1/3Nb2/3)O3-0.30PbTiO3 single crystal by 3 MHz bipolar field
Polarization switching and associated electromechanical property changes at 3.0 MHz were investigated with and without a direct current (dc) bias for [001]c poled 0.70Pb(Mg1/3Nb2/3)O3-0.30PbTiO3 single crystal. The results showed that the coercive field under a bipolar pulse at 3.0 MHz is 2.75 times as large as conventional defined Ec (2.58 kV/cm at 0.1 Hz), and a dc bias can further enlarge the driving field. Our results point to an innovative transducer operating mechanism at high frequencies since one could drive the crystal under much larger fields at high frequencies to produce much stronger signals from a small array element for deeper penetration imaging.
- 6 June 2016
- Published by AIP Publishing in Applied Physics Letters
- Vol. 108 (23) , 232901
Switching 70Pb(Mg1/3Nb2/3)O3-0.30PbTiO3 single crystal by 3 MHz bipolar field
Polarization switching and associated electromechanical property changes at 3.0 MHz were investigated with and without a direct current (dc) bias for [001]c poled 0.70Pb(Mg1/3Nb2/3)O3-0.30PbTiO3 single crystal. The results showed that the coercive field under a bipolar pulse at 3.0 MHz is 2.75 times as large as conventional defined Ec (2.58 kV/cm at 0.1 Hz), and a dc bias can further enlarge the driving field. Our results point to an innovative transducer operating mechanism at high frequencies since one could drive the crystal under much larger fields at high frequencies to produce much stronger signals from a small array element for deeper penetration imaging.
- 1 March 2015
- Published by Elsevier in Ultrasonics
- Vol. 57, 159-166
Temperature evaluation of traveling-wave ultrasonic motor considering interaction between temperature rise and motor parameters
- 1 March 2015
- Published by Elsevier in Ultrasonics
- Vol. 57, 159-166
Temperature evaluation of traveling-wave ultrasonic motor considering interaction between temperature rise and motor parameters
- 7 July 2014
- Published by AIP Publishing in Applied Physics Letters
- Vol. 105 (1) , 012901
Determination of full set material constants of [011]c poled 0.72Pb(Mg1/3Nb2/3)O3-0.28PbTiO3 single crystal from one sample
0.72Pb(Mg1/3Nb2/3)O3-0.28PbTiO3 single crystals poled along [011]c have macroscopic orthorhombic mm2 symmetry. There are total 17 independent material coefficients for this symmetry so that the determination of self-consistent full matrix data is extremely difficult because many samples are needed and there is a large property variation from sample to sample. To overcome this self-consistency difficulty, we have developed a combined ultrasonic pulse-echo and impedance spectroscopy method, which can extract all coefficients from only one small sample. This method is especially useful for piezoelectric materials whose properties are strongly dependent on geometry and for crystals with only limited size available.
- 7 July 2014
- Published by AIP Publishing in Applied Physics Letters
- Vol. 105 (1) , 012901
Determination of full set material constants of [011]c poled 0.72Pb(Mg1/3Nb2/3)O3-0.28PbTiO3 single crystal from one sample
0.72Pb(Mg1/3Nb2/3)O3-0.28PbTiO3 single crystals poled along [011]c have macroscopic orthorhombic mm2 symmetry. There are total 17 independent material coefficients for this symmetry so that the determination of self-consistent full matrix data is extremely difficult because many samples are needed and there is a large property variation from sample to sample. To overcome this self-consistency difficulty, we have developed a combined ultrasonic pulse-echo and impedance spectroscopy method, which can extract all coefficients from only one small sample. This method is especially useful for piezoelectric materials whose properties are strongly dependent on geometry and for crystals with only limited size available.
- Open Access
Nonlinearity Analysis and Parameters Optimization for an Inductive Angle Sensor
Using the finite element method (FEM) and particle swarm optimization (PSO), a nonlinearity analysis based on parameter optimization is proposed to design an inductive angle sensor. Due to the structure complexity of the sensor, understanding the influences of structure parameters on the nonlinearity errors is a critical step in designing an effective sensor. Key parameters are selected for the design based on the parameters’ effects on the nonlinearity errors. The finite element method and particle swarm optimization are combined for the sensor design to get the minimal nonlinearity error. In the simulation, the nonlinearity error of the optimized sensor is 0.053% in the angle range from −60° to 60°. A prototype sensor is manufactured and measured experimentally, and the experimental nonlinearity error is 0.081% in the angle range from −60° to 60°.
Open AccessNonlinearity Analysis and Parameters Optimization for an Inductive Angle Sensor
Using the finite element method (FEM) and particle swarm optimization (PSO), a nonlinearity analysis based on parameter optimization is proposed to design an inductive angle sensor. Due to the structure complexity of the sensor, understanding the influences of structure parameters on the nonlinearity errors is a critical step in designing an effective sensor. Key parameters are selected for the design based on the parameters’ effects on the nonlinearity errors. The finite element method and particle swarm optimization are combined for the sensor design to get the minimal nonlinearity error. In the simulation, the nonlinearity error of the optimized sensor is 0.053% in the angle range from −60° to 60°. A prototype sensor is manufactured and measured experimentally, and the experimental nonlinearity error is 0.081% in the angle range from −60° to 60°.
- 12 September 2013
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 114 (10) , 104505
Characterization of full set material constants of piezoelectric materials based on ultrasonic method and inverse impedance spectroscopy using only one sample
The most difficult task in the characterization of complete set material properties for piezoelectric materials is self-consistency. Because there are many independent elastic, dielectric, and piezoelectric constants, several samples are needed to obtain the full set constants. Property variation from sample to sample often makes the obtained data set lack of self-consistency. Here, we present a method, based on pulse-echo ultrasound and inverse impedance spectroscopy, to precisely determine the full set physical properties of piezoelectric materials using only one small sample, which eliminated the sample to sample variation problem to guarantee self-consistency. The method has been applied to characterize the [001]C poled Mn modified 0.27Pb(In1/2Nb1/2)O3-0.46Pb(Mg1/3Nb2/3)O3-0.27PbTiO3 single crystal and the validity of the measured data is confirmed by a previously established method. For the inverse calculations using impedance spectrum, the stability of reconstructed results is analyzed by fluctuation analysis of input data. In contrast to conventional regression methods, our method here takes the full advantage of both ultrasonic and inverse impedance spectroscopy methods to extract all constants from only one small sample. The method provides a powerful tool for assisting novel piezoelectric materials of small size and for generating needed input data sets for device designs using finite element simulations.
- 12 September 2013
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 114 (10) , 104505
Characterization of full set material constants of piezoelectric materials based on ultrasonic method and inverse impedance spectroscopy using only one sample
The most difficult task in the characterization of complete set material properties for piezoelectric materials is self-consistency. Because there are many independent elastic, dielectric, and piezoelectric constants, several samples are needed to obtain the full set constants. Property variation from sample to sample often makes the obtained data set lack of self-consistency. Here, we present a method, based on pulse-echo ultrasound and inverse impedance spectroscopy, to precisely determine the full set physical properties of piezoelectric materials using only one small sample, which eliminated the sample to sample variation problem to guarantee self-consistency. The method has been applied to characterize the [001]C poled Mn modified 0.27Pb(In1/2Nb1/2)O3-0.46Pb(Mg1/3Nb2/3)O3-0.27PbTiO3 single crystal and the validity of the measured data is confirmed by a previously established method. For the inverse calculations using impedance spectrum, the stability of reconstructed results is analyzed by fluctuation analysis of input data. In contrast to conventional regression methods, our method here takes the full advantage of both ultrasonic and inverse impedance spectroscopy methods to extract all constants from only one small sample. The method provides a powerful tool for assisting novel piezoelectric materials of small size and for generating needed input data sets for device designs using finite element simulations.
- 6 May 2013
- Published by AIP Publishing in Applied Physics Letters
- Vol. 102 (18)
A face-shear mode single crystal ultrasonic motor
We report a face-shear mode ultrasonic motor (USM) made of [011]c poled Zt ± 45° cut 0.24Pb(In1/2Nb1/2)O3-0.46Pb(Mg1/3Nb2/3)O3-0.30PbTiO3 single crystal, which takes advantage of the extremely large d36 = 2368 pC/N. This motor has a maximum no-load linear velocity of 182.5 mm/s and a maximum output force of 1.03 N under the drive of Vp = 50 V, f = 72 kHz. Compared with the k31 mode USM made of Pb(Zr,Ti)O3 (PZT), our USM has simpler structure, lower driving frequency, much higher electromechanical coupling factor, and twice power density. This USM can be used for low frequency operation as well as cryogenic actuation with a large torque.
- 6 May 2013
- Published by AIP Publishing in Applied Physics Letters
- Vol. 102 (18)
A face-shear mode single crystal ultrasonic motor
We report a face-shear mode ultrasonic motor (USM) made of [011]c poled Zt ± 45° cut 0.24Pb(In1/2Nb1/2)O3-0.46Pb(Mg1/3Nb2/3)O3-0.30PbTiO3 single crystal, which takes advantage of the extremely large d36 = 2368 pC/N. This motor has a maximum no-load linear velocity of 182.5 mm/s and a maximum output force of 1.03 N under the drive of Vp = 50 V, f = 72 kHz. Compared with the k31 mode USM made of Pb(Zr,Ti)O3 (PZT), our USM has simpler structure, lower driving frequency, much higher electromechanical coupling factor, and twice power density. This USM can be used for low frequency operation as well as cryogenic actuation with a large torque.