Howard M. Richard
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Howard M. Richard has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Alan McMillan
Department of Diagnostic Imaging Division of Interventional Radi- ology (H.M.R., B.J.d.) Division of Magnetic Resonance Imaging (A.M.)
1 shared publication- Bertrand Janne
Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, USA
1 shared publication - Bo Yang
Department of Mechanical Engineering, University of Maryland, MD, USA
1 shared publication David A. Van Echo
1 shared publicationDavid M. Widlus
From the University of Maryland Medical Center, Baltimore, Maryland
1 shared publicationDouglas M. Coldwell
1 shared publication
Latest Publications
- 3 May 2024
- Published by Springer Nature
- p. 443-451
Pelvic and Extremity Trauma
- 13 July 2023
- Published by Springer Nature
- p. 26-27
Percutaneous Iliac Artery Type II Endoleak Embolization Complicated by Active Extravasation
- 13 July 2023
- Published by Springer Nature
- p. 26-27
Percutaneous Iliac Artery Type II Endoleak Embolization Complicated by Active Extravasation
- 30 October 2013
- Published by SAGE Publications in The International Journal of Robotics Research
- Vol. 33 (4) , 616-630
Design, development, and evaluation of a master–slave surgical system for breast biopsy under continuous MRI
Magnetic Resonance Imaging (MRI) provides superior soft-tissue contrast in cancer diagnosis compared to other imaging modalities. However, the strong magnetic field inside the MRI bore along with limited scanner bore size poses significant challenges. Since current approaches in breast biopsy using MR images are primarily blind targeting approaches, it is necessary to develop an MRI-compatible robot that can avoid multiple needle insertions into the breast tissue. This MRI-compatible robotic system could potentially lead to improvement in the targeting accuracy and reduce sampling errors. A master–slave surgical system has been developed comprising a MRI-compatible slave robot which consists of one piezo motor and five pneumatic cylinders connected by long pneumatic transmission lines. The slave robot follows the configuration of the master robot, which provides an intuitive manipulation interface for the physician and operates inside the MRI bore to adjust the needle position and orientation and perform needle insertion tasks. Based on the MRI experiments using the slave robot, there was no significant distortion in the images, and hence the slave robot can be safely operated inside the MRI with minimal loss in signal-to-noise ratio (SNR). Ex vivo and in vivo experiments have been conducted to evaluate the performance of the master–slave surgical system.
- 30 October 2013
- Published by SAGE Publications in The International Journal of Robotics Research
- Vol. 33 (4) , 616-630
Design, development, and evaluation of a master–slave surgical system for breast biopsy under continuous MRI
Magnetic Resonance Imaging (MRI) provides superior soft-tissue contrast in cancer diagnosis compared to other imaging modalities. However, the strong magnetic field inside the MRI bore along with limited scanner bore size poses significant challenges. Since current approaches in breast biopsy using MR images are primarily blind targeting approaches, it is necessary to develop an MRI-compatible robot that can avoid multiple needle insertions into the breast tissue. This MRI-compatible robotic system could potentially lead to improvement in the targeting accuracy and reduce sampling errors. A master–slave surgical system has been developed comprising a MRI-compatible slave robot which consists of one piezo motor and five pneumatic cylinders connected by long pneumatic transmission lines. The slave robot follows the configuration of the master robot, which provides an intuitive manipulation interface for the physician and operates inside the MRI bore to adjust the needle position and orientation and perform needle insertion tasks. Based on the MRI experiments using the slave robot, there was no significant distortion in the images, and hence the slave robot can be safely operated inside the MRI with minimal loss in signal-to-noise ratio (SNR). Ex vivo and in vivo experiments have been conducted to evaluate the performance of the master–slave surgical system.
- 1 November 2012
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 23 (11) , 1539-1542
Real-time MR Imaging Guidance for Percutaneous Core Biopsy of US- and CT-negative Lesion
- 1 November 2012
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 23 (11) , 1539-1542
Real-time MR Imaging Guidance for Percutaneous Core Biopsy of US- and CT-negative Lesion
- 26 May 2011
- Published by Springer Nature in Emergency Radiology
- Vol. 18 (4) , 307-312
Optimizing multidetector CT for visualization of splenic vascular injury. Validation by splenic arteriography in blunt abdominal trauma patients
Nonoperative management of blunt splenic injury is the treatment of choice in hemodynamically stable patients. Detection of vascular injury by multidetector CT (MDCT) is the most significant factor predicting the need for endovascular treatment. This study evaluated the timing of the appearance of vascular lesions during angiography. Images from 20 patients embolized for pseudoaneurysms (PSA) were evaluated. Angiograms were reviewed for phase and timing of PSA. Admission MDCT was reviewed for injury grade and PSA. Initial MDCT evaluation indicated grade III and IV splenic injuries in 9 and 11 patients, respectively. PSA was seen on MDCT in 14/20 (70%) patients. Time from opacification of the aorta to vascular injury was 1.32 s for arterial phase injuries compared with 2.05 s for postcapillary injuries (P = 0.097). Angiography demonstrated 15 vascular injuries during the arterial and 5 in the venous phase. Of injuries seen during arterial phase angiography, 10/15 (66%) were identified on MDCT. Of the five injuries that exhibited postcapillary-phase findings, 4/5 (80%) demonstrated PSA (P = 0.5). Vascular lesions are a better indicator of subsequent clinical deterioration than splenic injury grade. PSAs are more frequently seen in postcapillary vascular injuries than arterial phase lesions with the current timing of MDCT. In a subset of patients in whom splenic injury grades III and IV warrant angiography, PSAs are not initially demonstrated on MDCT. Therefore, alteration of MDCT timing parameters to better correlate with arterial phase angiography may improve initial diagnosis of vascular injury.
- 26 May 2011
- Published by Springer Nature in Emergency Radiology
- Vol. 18 (4) , 307-312
Optimizing multidetector CT for visualization of splenic vascular injury. Validation by splenic arteriography in blunt abdominal trauma patients
Nonoperative management of blunt splenic injury is the treatment of choice in hemodynamically stable patients. Detection of vascular injury by multidetector CT (MDCT) is the most significant factor predicting the need for endovascular treatment. This study evaluated the timing of the appearance of vascular lesions during angiography. Images from 20 patients embolized for pseudoaneurysms (PSA) were evaluated. Angiograms were reviewed for phase and timing of PSA. Admission MDCT was reviewed for injury grade and PSA. Initial MDCT evaluation indicated grade III and IV splenic injuries in 9 and 11 patients, respectively. PSA was seen on MDCT in 14/20 (70%) patients. Time from opacification of the aorta to vascular injury was 1.32 s for arterial phase injuries compared with 2.05 s for postcapillary injuries (P = 0.097). Angiography demonstrated 15 vascular injuries during the arterial and 5 in the venous phase. Of injuries seen during arterial phase angiography, 10/15 (66%) were identified on MDCT. Of the five injuries that exhibited postcapillary-phase findings, 4/5 (80%) demonstrated PSA (P = 0.5). Vascular lesions are a better indicator of subsequent clinical deterioration than splenic injury grade. PSAs are more frequently seen in postcapillary vascular injuries than arterial phase lesions with the current timing of MDCT. In a subset of patients in whom splenic injury grades III and IV warrant angiography, PSAs are not initially demonstrated on MDCT. Therefore, alteration of MDCT timing parameters to better correlate with arterial phase angiography may improve initial diagnosis of vascular injury.
- 1 November 2008
- Published by Wolters Kluwer Health in Journal of Trauma: Injury, Infection & Critical Care
- Vol. 65 (5) , 1072-1077
Percutaneous Fluoroscopically Guided Jejunostomy Placement
Purpose: To describe our experience with fluoroscopically guided direct jejunostomy placement in patients with enterocutaneous fistula, or neoplastic or postsurgical changes of the stomach or duodenum that preclude traditional gastrostomy placement. Materials: Nineteen patients underwent percutaneous direct jejunostomy tube placement with fluoroscopic guidance from August 2004 through March 2006. There were 15 men and four women whose ages ranged from 28 to 82 years (mean, 54 years). Seven patients had surgical changes to the stomach that precluded traditional gastrostomy access, one patient had a duodenal tumor, two had unresectable gastric tumors, and nine had small bowel pathology that required distal access. Results: Jejunal access was initially successful in 18 of 19 (95%) procedures. Follow-up ranged from 10 days to 509 days. Two catheters were removed as they were no longer needed. Seven patients’ initial tubes were still functioning at the end of their follow-up. One tube was removed secondary to pain and irritation at the insertion site. Three tubes were occluded. One patients’ tube was inadvertently pulled out. In two patients, feeding was not tolerated secondary to fistula distal to the jejunostomy. Two patients died with their initial tubes. Primary patency was 285 days (95% CI 162–407). One death occurred 10 days postprocedure for a 30-day mortality of 1 of 19 (5%). Conclusions: Percutaneous direct jejunostomy placement is a relatively safe and effective means of gaining enteral access in patients who have enterocutaneous fistula or who have either postsurgical or neoplastic changes of the stomach that preclude traditional gastrostomy placement.
- 1 November 2008
- Published by Wolters Kluwer Health in Journal of Trauma: Injury, Infection & Critical Care
- Vol. 65 (5) , 1072-1077
Percutaneous Fluoroscopically Guided Jejunostomy Placement
Purpose: To describe our experience with fluoroscopically guided direct jejunostomy placement in patients with enterocutaneous fistula, or neoplastic or postsurgical changes of the stomach or duodenum that preclude traditional gastrostomy placement. Materials: Nineteen patients underwent percutaneous direct jejunostomy tube placement with fluoroscopic guidance from August 2004 through March 2006. There were 15 men and four women whose ages ranged from 28 to 82 years (mean, 54 years). Seven patients had surgical changes to the stomach that precluded traditional gastrostomy access, one patient had a duodenal tumor, two had unresectable gastric tumors, and nine had small bowel pathology that required distal access. Results: Jejunal access was initially successful in 18 of 19 (95%) procedures. Follow-up ranged from 10 days to 509 days. Two catheters were removed as they were no longer needed. Seven patients’ initial tubes were still functioning at the end of their follow-up. One tube was removed secondary to pain and irritation at the insertion site. Three tubes were occluded. One patients’ tube was inadvertently pulled out. In two patients, feeding was not tolerated secondary to fistula distal to the jejunostomy. Two patients died with their initial tubes. Primary patency was 285 days (95% CI 162–407). One death occurred 10 days postprocedure for a 30-day mortality of 1 of 19 (5%). Conclusions: Percutaneous direct jejunostomy placement is a relatively safe and effective means of gaining enteral access in patients who have enterocutaneous fistula or who have either postsurgical or neoplastic changes of the stomach that preclude traditional gastrostomy placement.
- 1 July 2005
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 16 (7) , 1039-1041
Retrieval of Bard Recovery Filter from Left-sided Inferior Vena Cava
- 1 July 2005
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 16 (7) , 1039-1041
Retrieval of Bard Recovery Filter from Left-sided Inferior Vena Cava
- 1 March 2001
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 12 (3) , 373-375
Pleurx Tunneled Catheter in the Management of Malignant Ascites
- 1 March 2001
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 12 (3) , 373-375
Pleurx Tunneled Catheter in the Management of Malignant Ascites