DCDavid P. Crabb

David P. Crabb

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


David P. Crabb has a total of 19 co-authors. Here are the top co-authors by number of shared publications:

  • David Frcophth Garway-Heath

    NIHR Biomedical Research Centre, Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology, London, United Kingdom

    4 shared publications
  • Haogang Zhu

    Department of Optometry and Visual Science, City University London, London, UK

    3 shared publications
  • Nicholas D. Smith

    Department of Optometry and Visual Science, School of Health Sciences, City University London, London, UK

    3 shared publications
  • Robyn Burton

    Department of Optometry and Visual Science, City University London, Northampton Square, London, EC1V 0HB, UK

    2 shared publications
  • Caroline J Doré

    UCL Comprehensive Clinical Trials Unit, University College London, London, UK

    1 shared publication
  • Catey Bunce

    Epidemiology and Population Health, London School of Hygiene & Tropical Medicine, London, UK

    1 shared publication

Latest Publications

  • Open Access

    Measurement Precision in a Series of Visual Fields Acquired by the Standard and Fast Versions of the Swedish Interactive Thresholding Algorithm

    by Luke J. Saunders, Richard A. Russell, David P. Crabb

    Progression of glaucoma needs to be monitored carefully to ensure appropriate treatment can be given to prevent sight loss. Visual field (VF) testing is the only direct means of measuring functional impairment in glaucoma but yields highly variable measurements. Moreover, measurement variability increases with declining VF sensitivity.1-3 As a result, detecting VF progression is far from straightforward, with significant potential for detecting false change or failing to detect definite change.


  • Open Access

    Ophthalmic statistics note 5: diagnostic tests—sensitivity and specificity

    by Luke J Saunders, Haogang Zhu, Catey Bunce, Caroline J Doré, Nick Freemantle, David P Crabb, This fifth note from the Ophthalmic Statistics Group illustrates the utility of measurements of sensitivity and specificity in assessing the usefulness of a test for predicting the presence of pathology

    This is the fifth statistics note produced by the Ophthalmic Statistics Group (OSG) which is designed to be a simple guide to ophthalmic researchers on a statistical issue with an applied ophthalmic example. The OSG is a collaborative group of statisticians who have come together with a desire to raise the statistical standards of ophthalmic researcher by increasing statistical awareness of common issues.


  • Open Access

    What's on TV? Detecting age-related neurodegenerative eye disease using eye movement scanpaths

    by David P. Crabb, Nicholas D. Smith, Haogang Zhu

    Purpose: We test the hypothesis that age-related neurodegenerative eye disease can be detected by examining patterns of eye movement recorded whilst a person naturally watches a movie. Methods: Thirty-two elderly people with healthy vision (median age: 70, interquartile range [IQR] 64 to 75 yrs) and 44 patients with a clinical diagnosis of glaucoma (median age: 69, IQR 63 to 77 yrs) had standard vision examinations including automated perimetry. Disease severity was measured using a standard clinical measure (visual field mean deviation; MD). All study participants viewed three unmodified TV and film clips on a computer set up incorporating the Eyelink 1000 eyetracker (SR Research, Ontario, Canada). Eye movement scanpaths were plotted using novel methods that first filtered the data and then generated saccade density maps. Maps were then subjected to a feature extraction analysis using kernel principal component analysis (KPCA). Features from the KPCA were then classified using a standard machine based classifier trained and tested by a 10-fold cross validation which was repeated 100 times to estimate the confidence interval (CI) of classification sensitivity and specificity. Results: Patients had a range of disease severity from early to advanced (median [IQR] right eye and left eye MD was -7 [-13 to -5] dB and -9 [-15 to -4] dB respectively). Average sensitivity for correctly identifying a glaucoma patient at a fixed specificity of 90% was 79% (95% CI: 58 to 86%). The area under the Receiver Operating Characteristic curve was 0.84 (95% CI: 0.82 to 0.87). Conclusions: Huge data from scanpaths of eye movements recorded whilst people freely watch TV type films can be processed into maps that contain a signature of vision loss. In this proof of principle study we have demonstrated that a group of patients with age-related neurodegenerative eye disease can be reasonably well separated from a group of healthy peers by considering these eye movement signatures alone.


  • Eye movements and reading in glaucoma: observations on patients with advanced visual field loss

    by Robyn Burton, Nicholas D. Smith, David P. Crabb

    To investigate the relationship between reading speed and eye movements in patients with advanced glaucomatous visual field (VF) defects and age-similar visually healthy people. Eighteen patients with advanced bilateral VF defects (mean age: 71, standard deviation [SD]: 7 years) and 39 controls (mean age: 67, SD: 8 years) had reading speed measured using short passages of text on a computer set-up incorporating eye tracking. Scanpaths were plotted and analysed from these experiments to derive measures of ‘perceptual span’ (total number of letters read per number of saccades) and ‘text saturation’ (the distance between the first and last fixation on lines of text). Another eye movement measure, termed ‘saccadic frequency’ (total number of saccades made to read a single word), was derived from a separate lexical decision task, where words were presented in isolation. Significant linear association was demonstrated between perceptual span and reading speed in patients (R 2 = 0.42) and controls (R 2 = 0.56). Linear association between saccadic frequency during the LDT and reading speed was also found in patients (R 2 = 0.42), but not in controls (R 2 = 0.02). Patients also exhibited greater average text saturation than controls (P = 0.004). Some, but not all, patients with advanced VF defects read slower than controls using short text passages. Differences in eye movement behaviour may partly account for this variability in patients. These patients were shown to saturate lines of text more during reading, which may explain previously-reported difficulties with sustained reading.


  • Open Access

    How Does Glaucoma Look?

    by David P. Crabb, Nicholas D. Smith, Fiona C. Glen, Robyn Burton, David F. Garway-Heath


  • Open Access

    Intervals between Visual Field Tests When Monitoring the Glaucomatous Patient: Wait-and-See Approach

    by David P. Crabb, David F. Garway-Heath

    Purpose.: Published recommendations suggest three visual field (VF) tests per year are required to identify rapid progression in a newly diagnosed glaucomatous patient over 2 years. This report aims to determine if identification of progression would be improved by clustering tests at the beginning and end of the 2-year period. Methods.: Computer-simulated “patients” were given a rapid VF (mean deviation [MD]) loss of −2 dB/year with added MD measurement variability. Linear regression of MD against time was used to estimate progression. One group of “patients” was measured every 6 months, another every 4 months, whereas the wait-and-see group were measured either 2 or 3 times at both baseline and at the end of a 2-year period. Stable “patients” (0 dB/year) were generated to examine the effect of the follow-up patterns on false-positive (FP) progression identification. Results.: By 2 years, 58% and 82% of rapidly progressing patients were correctly detected using evenly spaced 6- and 4-month VFs, respectively. This power of detection significantly improved to 62% and 95% with the wait-and-see approach (P < 0.001). When compared with evenly spaced VFs, the rate of MD loss was better estimated by the wait-and-see approach, but average detection time was slightly slower. Evenly spaced testing incurred a significantly higher FP rate: up to 5.9% compared with only 0.4% in wait-and-see (P < 0.001). Conclusions.: Compared with an evenly spaced follow-up, wait-and-see identifies more “patients” with rapid VF progression with fewer FPs, making it particularly applicable to clinical trials. Modeling experiments, as reported here, are useful for investigating and optimizing follow-up schemes.


  • Open Access

    Predicting Visual Function from the Measurements of Retinal Nerve Fiber Layer Structure

    by Haogang Zhu, David P. Crabb, Patricio G. Schlottmann, Hans G. Lemij, Nicolaas J. Reus, Paul R. Healey, Paul Mitchell, Tuan Ho, David F. Garway-Heath

    Purpose.: To develop and validate a method of predicting visual function from retinal nerve fiber layer (RNFL) structure in glaucoma. Methods.: RNFL thickness (RNFLT) measurements from scanning laser polarimetry (SLP) and visual field (VF) sensitivity from standard automated perimetry were made available for 535 eyes from three centers. In a training dataset, structure–function relationships were characterized by using linear regression and a type of neural network: radial basis function customized under a Bayesian framework (BRBF). These two models were used in a test dataset to (1) predict sensitivity at individual VF locations from RNFLT measurements and (2) predict the spatial relationship between VF locations and positions at a peripapillary RNFLT measurement annulus. Predicted spatial relationships were compared with a published anatomic structure–function map. Results.: Compared with linear regression, BRBF yielded a nearly twofold improvement (P < 0.001; paired t-test) in performance of predicting VF sensitivity in the test dataset (mean absolute prediction error of 2.9 dB [SD 3.7] versus 4.9 dB [SD 4.0]). The predicted spatial structure–function relationship showed better agreement (P < 0.001; paired t-test) with anatomic prior knowledge when the BRBF was compared with the linear regression (median absolute angular difference of 15° vs. 62°). Conclusions.: The BRBF generates clinically useful relationships that relate topographical maps of RNFL measurement to VF locations and allows the VF sensitivity to be predicted from structural measurements. This method may allow clinicians to evaluate structural and functional measures in the same domain. It could also be generalized to use other structural measures.


  • Evaluating the effect of the new alignment algorithm for longitudinal series of Heidelberg retina tomography images

    by Ciara Bergin, David F. Garway‐Heath, David P. Crabb

    To evaluate the impact of a new image-alignment algorithm on the repeatability of longitudinal measurements obtained from Heidelberg retina tomograph (HRT) images. HRTI and HRTII image series from 124 patients with glaucoma or ocular hypertension were made available from previously reported studies and were reprocessed with the old and new image-alignment algorithms. Improvements afforded by the new alignment algorithm were examined by considering statistically significant improvement in repeatability of specific stereometric parameters (SP), namely rim area (RA), rim volume (RV), cup volume (CV) and cup shape measure (CSM). A further comparison was made by examining reduction in the variability of pixel-by-pixel height measures within image series. In some HRT image series, the new algorithm automatically corrected obvious misalignment events that occurred with the previous algorithm. However, average improvement in repeatability of the SP in HRTI image series was not statistically significant (P = 0.13) and there was no statistically significant reduction in pixel-by-pixel height measurement variability (P =0.73). In HRTII image series, there was evidence of improvement, on average, in the repeatability of some parameters (RA, P = 0.01; RV, P = 0.02; CSM, P = 0.05), but not in CV (P = 0.22). There was a large reduction in pixel-by-pixel variability in HRTII image series (P < 0.001). There was no evidence to show that the new algorithm improved repeatability, on average, in HRTI images. However, the application of the new algorithm to HRTII image series marginally improved repeatability in stereometric measures and yielded a significant reduction in pixel-by-pixel variability.