Jennifer B. Tufts
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jennifer B. Tufts has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Michelle R. Molis
Portland VA Medical Center National Center for Rehabilitative Auditory Research 3710 SW US Veterans Hospital Road, Portland, Oregon 97207
3 shared publicationsLynne Marshall
Naval Submarine Medical Research Laboratory, Groton, Connecticut, USA
2 shared publications- Lynne Marshall
Naval Submarine Medical Research Laboratory, Box 900, Subase NLON, Box 900, Groton, Connecticut 06349-5900
2 shared publications - Siyuan Chen
Department of Speech, Language, and Hearing Sciences, University of Connecticut , 850 Bolton Road, Unit 1085, Storrs, Connecticut 06269
2 shared publications AmandaJ Ucci
1 shared publicationChristian Giguère
B Audiology and Speech-Language Pathology Program , University of Ottawa , Ottawa , Canada
1 shared publication
Latest Publications
- 1 March 2018
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 143 (3_Suppleme) , 1780
Development and implementation of a military auditory fitness-for-duty test battery
Hearing loss is prevalent throughout the active duty military forces. However, there are no validated standards for assessing a service member’s functional hearing ability and how it relates to his or her ability to accomplish the mission. In many cases, hearing-critical tasks take place in non-optimal environments with background noise or competing speech from multiple sources. Presently, hearing abilities are primarily assessed via pure-tone audiometry, without regard for the hearing-critical needs and noise environment of the individual. The development of a test battery to evaluate functional hearing ability is a highly sought-after goal. With support from the Department of Defense, Creare LLC and the University of Connecticut are developing the MILSINT, a new sound-recognition-in-noise test geared specifically for active duty personnel. The MILSINT is one component of an auditory fitness-for-duty test battery that at present also includes the Military HINT, a version of the Hearing In Noise Test (HINT) that uses military-specific phrases. The MILSINT and Military HINT are administered using a tablet interface and wireless sound-attenuating headset developed by Creare, LLC., making these tests highly portable and versatile. This presentation will describe the development of the test battery, its physical implementation, and performance data gathered to date.
- 1 March 2018
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 143 (3_Suppleme) , 1780
Development and implementation of a military auditory fitness-for-duty test battery
Hearing loss is prevalent throughout the active duty military forces. However, there are no validated standards for assessing a service member’s functional hearing ability and how it relates to his or her ability to accomplish the mission. In many cases, hearing-critical tasks take place in non-optimal environments with background noise or competing speech from multiple sources. Presently, hearing abilities are primarily assessed via pure-tone audiometry, without regard for the hearing-critical needs and noise environment of the individual. The development of a test battery to evaluate functional hearing ability is a highly sought-after goal. With support from the Department of Defense, Creare LLC and the University of Connecticut are developing the MILSINT, a new sound-recognition-in-noise test geared specifically for active duty personnel. The MILSINT is one component of an auditory fitness-for-duty test battery that at present also includes the Military HINT, a version of the Hearing In Noise Test (HINT) that uses military-specific phrases. The MILSINT and Military HINT are administered using a tablet interface and wireless sound-attenuating headset developed by Creare, LLC., making these tests highly portable and versatile. This presentation will describe the development of the test battery, its physical implementation, and performance data gathered to date.
- 5 January 2018
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 57 (sup1) , S1-S2
The River of Aural Serenity: selected papers from the 2017 Annual Conference of the National Hearing Conservation Association
(2018). The River of Aural Serenity: selected papers from the 2017 Annual Conference of the National Hearing Conservation Association. International Journal of Audiology: Vol. 57, The River of Aural Serenity, pp. S1-S2.
- 5 January 2018
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 57 (sup1) , S1-S2
The River of Aural Serenity: selected papers from the 2017 Annual Conference of the National Hearing Conservation Association
(2018). The River of Aural Serenity: selected papers from the 2017 Annual Conference of the National Hearing Conservation Association. International Journal of Audiology: Vol. 57, The River of Aural Serenity, pp. S1-S2.
- 24 November 2017
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 57 (sup1) , S20-S27
Examining the noisy life of the college musician: weeklong noise dosimetry of music and non-music activities
Objective: To examine the contribution of all daily activities, including non-music activities, to the overall noise exposure of college student musicians, and to compare their “noise lives” with those of non-musician college students. Design: Continuous week-long dosimetry measurements were collected on student musicians and non-musicians. During the measurement period, participants recorded their daily activities in journals. Study sample: 22 musicians and 40 non-musicians, all students (aged 18–24 years) at the University of Connecticut. Results: On every day of the week, musicians experienced significantly higher average exposure levels than did non-musicians. Nearly half (47%) of the musicians’ days exceeded a daily dose of 100%, compared with 10% of the non-musicians’ days. When the exposure due to music activities was removed, musicians still led noisier lives, largely due to participation in noisier social activities. For some musicians, non-music activities contributed a larger share of their total weekly noise exposure than did their music activities. Conclusions: Compared with their non-musician peers, college student musicians are at higher risk for noise-induced hearing loss (NIHL). On a weekly basis, non-music activities may pose a greater risk to some musicians than music activities. Thus, hearing health education for musicians should include information about the contribution of lifestyle factors outside of music to NIHL risk.
- 24 November 2017
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 57 (sup1) , S20-S27
Examining the noisy life of the college musician: weeklong noise dosimetry of music and non-music activities
Objective: To examine the contribution of all daily activities, including non-music activities, to the overall noise exposure of college student musicians, and to compare their “noise lives” with those of non-musician college students. Design: Continuous week-long dosimetry measurements were collected on student musicians and non-musicians. During the measurement period, participants recorded their daily activities in journals. Study sample: 22 musicians and 40 non-musicians, all students (aged 18–24 years) at the University of Connecticut. Results: On every day of the week, musicians experienced significantly higher average exposure levels than did non-musicians. Nearly half (47%) of the musicians’ days exceeded a daily dose of 100%, compared with 10% of the non-musicians’ days. When the exposure due to music activities was removed, musicians still led noisier lives, largely due to participation in noisier social activities. For some musicians, non-music activities contributed a larger share of their total weekly noise exposure than did their music activities. Conclusions: Compared with their non-musician peers, college student musicians are at higher risk for noise-induced hearing loss (NIHL). On a weekly basis, non-music activities may pose a greater risk to some musicians than music activities. Thus, hearing health education for musicians should include information about the contribution of lifestyle factors outside of music to NIHL risk.
- 1 May 2013
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 133 (6) , EL446-EL451
Attenuation as a function of the canal length of custom-molded earplugs: A pilot study
Custom-molded earplugs (CMEPs) whose canal segments extend beyond the second bend of the ear canal can provide excellent attenuation but can sometimes be uncomfortable. Attenuation was measured for CMEPs whose canal segments were shortened in 2-mm increments. The within-subjects design permitted illustration of the form of the function relating attenuation to canal segment length for individuals. Reduction of attenuation due to canal segment shortening was generally more pronounced for frequencies ≤1000 Hz. Some regions of the canal segments were more critical than others in maintaining attenuation. The relationship between comfort and canal segment length was not straightforward.
- 1 May 2013
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 133 (6) , EL446-EL451
Attenuation as a function of the canal length of custom-molded earplugs: A pilot study
Custom-molded earplugs (CMEPs) whose canal segments extend beyond the second bend of the ear canal can provide excellent attenuation but can sometimes be uncomfortable. Attenuation was measured for CMEPs whose canal segments were shortened in 2-mm increments. The within-subjects design permitted illustration of the form of the function relating attenuation to canal segment length for individuals. Reduction of attenuation due to canal segment shortening was generally more pronounced for frequencies ≤1000 Hz. Some regions of the canal segments were more critical than others in maintaining attenuation. The relationship between comfort and canal segment length was not straightforward.
- 1 January 2013
- Published by Acoustical Society of America (ASA) in Proceedings of Meetings on Acoustics
Attenuation as a function of the canal length of custom-molded earplugs
The fit of a custom-molded earplug (CMEP) and the amount of attenuation it provides can be affected by variables related to the original earmold impression and the subsequent manufacturing process. One variable thought to affect the amount of attenuation is the length of the canal portion of the CMEP. In this pilot study, we systematically examined the relationship between CMEP canal length and attenuation in four human subjects. Two men and two women were fitted with CMEPs extending past the second bend of the ear canal. The attenuation provided by the CMEPs was measured over four visits to the laboratory. Prior to each visit, the canal portion of the subject's test CMEP was shortened by 2mm. As expected, attenuation decreased as canal length decreased for all subjects. However, the rate and pattern of decrease varied markedly. Anecdotal reports of comfort as a function of canal length also varied markedly. Results suggest that the critical region/s in the ear canal for maintaining a good acoustic seal may vary from person to person. Implications for future study will be discussed.
- 1 January 2013
- Published by Acoustical Society of America (ASA) in Proceedings of Meetings on Acoustics
Attenuation as a function of the canal length of custom-molded earplugs
The fit of a custom-molded earplug (CMEP) and the amount of attenuation it provides can be affected by variables related to the original earmold impression and the subsequent manufacturing process. One variable thought to affect the amount of attenuation is the length of the canal portion of the CMEP. In this pilot study, we systematically examined the relationship between CMEP canal length and attenuation in four human subjects. Two men and two women were fitted with CMEPs extending past the second bend of the ear canal. The attenuation provided by the CMEPs was measured over four visits to the laboratory. Prior to each visit, the canal portion of the subject's test CMEP was shortened by 2mm. As expected, attenuation decreased as canal length decreased for all subjects. However, the rate and pattern of decrease varied markedly. Anecdotal reports of comfort as a function of canal length also varied markedly. Results suggest that the critical region/s in the ear canal for maintaining a good acoustic seal may vary from person to person. Implications for future study will be discussed.
- Open Access
- 24 December 2012
- Published by Oxford University Press (OUP) in Annals of Occupational Hygiene
- Vol. 57 (5) , 571-580
Consistency of Attenuation across Multiple Fittings of Custom and Non-custom Earplugs
Hearing protection devices (HPDs) play a significant role in protecting workers from occupational noise-induced hearing loss. Individual HPD fit-testing estimates the amount of protection, or attenuation, that an individual achieves from a given HPD as it is worn. Results from a single fit-test may not be representative of real-world HPD performance over time, however, due to inconsistency in how the individual fits the HPD from time to time. In this study, the effects of HPD type and user training on the consistency of attenuation achieved across multiple fittings were evaluated in a within-subjects design. Attenuation measurements using a real-ear attenuation at threshold procedure were obtained on 30 participants wearing custom-molded and non-custom earplugs. The subjects were initially naive to proper earplug insertion techniques and later received one-on-one training for the second half of the attenuation measurements. Consistency, or reliability, of fit was assessed using (i) the standard deviation of the ‘distance to ear mean attenuation’, a measure of fitting uncertainty, and (ii) the standard deviation of the attenuation values across multiple fit-tests for each subject. The custom earplug provided statistically significantly better consistency of attenuation than the non-custom earplug at 500, 1000, and 2000 Hz. Training effects were statistically significant at 250, 500, and 1000 Hz and at the Personal Attenuation Rating. No interactions were statistically significant. These results indicate that, in general, subjects obtained more consistent attenuation with the custom earplugs than with the non-custom earplugs and that consistency improved with training for both earplug types.
- 24 December 2012
- Published by Oxford University Press (OUP) in Annals of Occupational Hygiene
- Vol. 57 (5) , 571-580
Open AccessConsistency of Attenuation across Multiple Fittings of Custom and Non-custom Earplugs
Hearing protection devices (HPDs) play a significant role in protecting workers from occupational noise-induced hearing loss. Individual HPD fit-testing estimates the amount of protection, or attenuation, that an individual achieves from a given HPD as it is worn. Results from a single fit-test may not be representative of real-world HPD performance over time, however, due to inconsistency in how the individual fits the HPD from time to time. In this study, the effects of HPD type and user training on the consistency of attenuation achieved across multiple fittings were evaluated in a within-subjects design. Attenuation measurements using a real-ear attenuation at threshold procedure were obtained on 30 participants wearing custom-molded and non-custom earplugs. The subjects were initially naive to proper earplug insertion techniques and later received one-on-one training for the second half of the attenuation measurements. Consistency, or reliability, of fit was assessed using (i) the standard deviation of the ‘distance to ear mean attenuation’, a measure of fitting uncertainty, and (ii) the standard deviation of the attenuation values across multiple fit-tests for each subject. The custom earplug provided statistically significantly better consistency of attenuation than the non-custom earplug at 500, 1000, and 2000 Hz. Training effects were statistically significant at 250, 500, and 1000 Hz and at the Personal Attenuation Rating. No interactions were statistically significant. These results indicate that, in general, subjects obtained more consistent attenuation with the custom earplugs than with the non-custom earplugs and that consistency improved with training for both earplug types.
- 3 September 2012
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 51 (10) , 730-738
Measurements of earplug attenuation under supra-aural and circumaural headphones
Objective: Supra-aural audiometric headphones are generally not recommended for use in measuring the attenuation of earplugs, because contact between the headphone and pinna and/or earplug could alter the attenuation obtained, and because of concerns of non-comparability between modes of excitation from supra-aural headphones and the sound-field procedure required by the standardized method. In this study, we compared measurements of earplug attenuation obtained under Telephonics TDH-50P supra-aural headphones with measurements obtained under circumaural headphones designed expressly for such testing. Design: The attenuation of three types of earplugs (foam, premolded quadruple-flange, and custom-molded) was measured in a repeated-measures design. Study sample: The study sample comprised 42 normal-hearing adults (21 females, 21 males). Results: With the foam earplugs, nearly all of the attenuation measurements under the supra-aural headphones fell within 10 dB of the measurements under the circumaural headphones. With the flange and custom earplugs, approximately 10% of individuals obtained spuriously high attenuation under the supra-aural headphones. Conclusions: We conclude that standard supra-aural audiometric headphones are suitable for measuring the attenuation provided by foam earplugs. However, supra-aural headphones should not be used to measure the attenuation of flange or custom-molded earplugs. The potential exists for substantial over-estimation of attenuation, especially of custom plugs.
- 3 September 2012
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 51 (10) , 730-738
Measurements of earplug attenuation under supra-aural and circumaural headphones
Objective: Supra-aural audiometric headphones are generally not recommended for use in measuring the attenuation of earplugs, because contact between the headphone and pinna and/or earplug could alter the attenuation obtained, and because of concerns of non-comparability between modes of excitation from supra-aural headphones and the sound-field procedure required by the standardized method. In this study, we compared measurements of earplug attenuation obtained under Telephonics TDH-50P supra-aural headphones with measurements obtained under circumaural headphones designed expressly for such testing. Design: The attenuation of three types of earplugs (foam, premolded quadruple-flange, and custom-molded) was measured in a repeated-measures design. Study sample: The study sample comprised 42 normal-hearing adults (21 females, 21 males). Results: With the foam earplugs, nearly all of the attenuation measurements under the supra-aural headphones fell within 10 dB of the measurements under the circumaural headphones. With the flange and custom earplugs, approximately 10% of individuals obtained spuriously high attenuation under the supra-aural headphones. Conclusions: We conclude that standard supra-aural audiometric headphones are suitable for measuring the attenuation provided by foam earplugs. However, supra-aural headphones should not be used to measure the attenuation of flange or custom-molded earplugs. The potential exists for substantial over-estimation of attenuation, especially of custom plugs.
- Open Access
- 1 January 2011
- Published by Medknow in Noise and Health
- Vol. 13 (50) , 26-36
Evaluation by industrial workers of passive and level-dependent hearing protection devices
Level-dependent hearing protection devices (HPDs) provide protection from intense sound, while offering amplification for speech and other signals in lower levels of noise. These HPDs have been developed in response to the communication and operational needs of noise-exposed persons in industry and the military. This study was conducted to examine industrial workers' perceptions of the performance of two level-dependent HPDs (one with integrated radio communication capability and one without it) and their customary passive HPDs. This research took place at a plastic film manufacturing plant in Rhode Island, USA, following a mixed-measures design. Fifteen maintenance technicians at the plant evaluated the two level-dependent HPDs, plus their customary passive HPDs, in three separate trial periods. Data were collected via a questionnaire designed for this purpose. Mixed-model analyses of variance were performed on all dependent measures. Linear and quadratic effect sizes were assessed with eta. Results revealed that the two level-dependent HPDs offered better perceived communication and situational awareness than the workers' customary passive HPDs. However, the level-dependent HPDs were rated lower than the passive HPDs in terms of usability and comfort. To increase workers' acceptance of level-dependent HPDs, usability issues must be addressed by the HPD manufacturers.
- 1 January 2011
- Published by Medknow in Noise and Health
- Vol. 13 (50) , 26-36
Open AccessEvaluation by industrial workers of passive and level-dependent hearing protection devices
Level-dependent hearing protection devices (HPDs) provide protection from intense sound, while offering amplification for speech and other signals in lower levels of noise. These HPDs have been developed in response to the communication and operational needs of noise-exposed persons in industry and the military. This study was conducted to examine industrial workers' perceptions of the performance of two level-dependent HPDs (one with integrated radio communication capability and one without it) and their customary passive HPDs. This research took place at a plastic film manufacturing plant in Rhode Island, USA, following a mixed-measures design. Fifteen maintenance technicians at the plant evaluated the two level-dependent HPDs, plus their customary passive HPDs, in three separate trial periods. Data were collected via a questionnaire designed for this purpose. Mixed-model analyses of variance were performed on all dependent measures. Linear and quadratic effect sizes were assessed with eta. Results revealed that the two level-dependent HPDs offered better perceived communication and situational awareness than the workers' customary passive HPDs. However, the level-dependent HPDs were rated lower than the passive HPDs in terms of usability and comfort. To increase workers' acceptance of level-dependent HPDs, usability issues must be addressed by the HPD manufacturers.
- Open Access
- 26 March 2010
- Published by Scandinavian Journal of Work, Environment and Health in Scandinavian Journal of Work, Environment & Health
- Vol. 36 (3) , 242-249
Modeling the Unites States government’s economic cost of noise-induced hearing loss for a military population
Objective The purpose of this paper is to demonstrate the feasibility and utility of developing economic cost models for noise-induced hearing loss (NIHL). First, we outline an economic model of NIHL for a population of US Navy sailors with an “industrial”-type noise exposure. Next, we describe the effect on NIHL-related cost of varying the two central model inputs – the noise-exposure level and the duration of exposure. Such an analysis can help prioritize promising areas, to which limited resources to reduce NIHL-related costs should be devoted. Methods NIHL-related costs borne by the US government were computed on a yearly basis using a finite element approach that took into account varying levels of susceptibility to NIHL. Predicted hearing thresholds for the population were computed with ANSI S3.44–1996 and then used as the basis for the calculation of NIHL-related costs. Annual and cumulative costs were tracked. Noise-exposure level and duration were systematically varied to determine their effects on the expected lifetime NIHL-related cost of a specific US Navy sailor population. Results Our nominal noise-exposure case [93 dB(A) for six years] yielded a total expected lifetime cost of US$13 472 per sailor, with plausible lower and upper bounds of US$2500 and US$26 000. Starting with the nominal case, a decrease of 50% in exposure level or duration would yield cost savings of approximately 23% and 19%, respectively. We concluded that a reduction in noise level would be more somewhat more cost-effective than the same percentage reduction in years of exposure. Conclusion Our economic cost model can be used to estimate the changes in NIHL-related costs that would result from changes in noise-exposure level and/or duration for a single military population. Although the model is limited at present, suggestions are provided for adapting it to civilian populations.
- 26 March 2010
- Published by Scandinavian Journal of Work, Environment and Health in Scandinavian Journal of Work, Environment & Health
- Vol. 36 (3) , 242-249
Open AccessModeling the Unites States government’s economic cost of noise-induced hearing loss for a military population
Objective The purpose of this paper is to demonstrate the feasibility and utility of developing economic cost models for noise-induced hearing loss (NIHL). First, we outline an economic model of NIHL for a population of US Navy sailors with an “industrial”-type noise exposure. Next, we describe the effect on NIHL-related cost of varying the two central model inputs – the noise-exposure level and the duration of exposure. Such an analysis can help prioritize promising areas, to which limited resources to reduce NIHL-related costs should be devoted. Methods NIHL-related costs borne by the US government were computed on a yearly basis using a finite element approach that took into account varying levels of susceptibility to NIHL. Predicted hearing thresholds for the population were computed with ANSI S3.44–1996 and then used as the basis for the calculation of NIHL-related costs. Annual and cumulative costs were tracked. Noise-exposure level and duration were systematically varied to determine their effects on the expected lifetime NIHL-related cost of a specific US Navy sailor population. Results Our nominal noise-exposure case [93 dB(A) for six years] yielded a total expected lifetime cost of US$13 472 per sailor, with plausible lower and upper bounds of US$2500 and US$26 000. Starting with the nominal case, a decrease of 50% in exposure level or duration would yield cost savings of approximately 23% and 19%, respectively. We concluded that a reduction in noise level would be more somewhat more cost-effective than the same percentage reduction in years of exposure. Conclusion Our economic cost model can be used to estimate the changes in NIHL-related costs that would result from changes in noise-exposure level and/or duration for a single military population. Although the model is limited at present, suggestions are provided for adapting it to civilian populations.
- 1 October 2009
- Published by American Academy of Audiology in Journal of the American Academy of Audiology
- Vol. 20 (9) , 539-557
Auditory Fitness for Duty: A Review
Background: Auditory fitness for duty (AFFD) refers to the possession of hearing abilities sufficient for safe and effective job performance. In jobs such as law enforcement and piloting, where the ability to hear is critical to job performance and safety, hearing loss can decrease performance, even to the point of being hazardous to self and others. Tests of AFFD should provide an employer with a valid assessment of an employee's ability to perform the job safely, without discriminating against the employee purely on the basis of hearing loss. Purpose: The purpose of this review is to provide a basic description of the functional hearing abilities required in hearing-critical occupations, and a summary of current practices in AFFD evaluation. In addition, we suggest directions for research and standardization to ensure best practices in the evaluation of AFFD in the future. Research Design: We conducted a systematic review of the English-language peer-reviewed literature in AFFD. “Popular” search engines were consulted for governmental regulations and trade journal articles. We also contacted professionals with expertise in AFFD regarding research projects, unpublished material, and current standards. Results: The literature review provided information regarding the functional hearing abilities required to perform hearing-critical tasks, the development of and characteristics of AFFD protocols, and the current implementation of AFFD protocols. Conclusions: This review paper provides evidence of the need to institute job-specific AFFD protocols, move beyond the pure-tone audiogram, and establish the validity of test protocols. These needs are arguably greater now than in times past.
- 1 October 2009
- Published by American Academy of Audiology in Journal of the American Academy of Audiology
- Vol. 20 (9) , 539-557
Auditory Fitness for Duty: A Review
Background: Auditory fitness for duty (AFFD) refers to the possession of hearing abilities sufficient for safe and effective job performance. In jobs such as law enforcement and piloting, where the ability to hear is critical to job performance and safety, hearing loss can decrease performance, even to the point of being hazardous to self and others. Tests of AFFD should provide an employer with a valid assessment of an employee's ability to perform the job safely, without discriminating against the employee purely on the basis of hearing loss. Purpose: The purpose of this review is to provide a basic description of the functional hearing abilities required in hearing-critical occupations, and a summary of current practices in AFFD evaluation. In addition, we suggest directions for research and standardization to ensure best practices in the evaluation of AFFD in the future. Research Design: We conducted a systematic review of the English-language peer-reviewed literature in AFFD. “Popular” search engines were consulted for governmental regulations and trade journal articles. We also contacted professionals with expertise in AFFD regarding research projects, unpublished material, and current standards. Results: The literature review provided information regarding the functional hearing abilities required to perform hearing-critical tasks, the development of and characteristics of AFFD protocols, and the current implementation of AFFD protocols. Conclusions: This review paper provides evidence of the need to institute job-specific AFFD protocols, move beyond the pure-tone audiogram, and establish the validity of test protocols. These needs are arguably greater now than in times past.