Simona Ben-Haim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Simona Ben-Haim has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
Elite Arnon
Rambam Health Care Campus
3 shared publicationsJamshed Bomanji
Institute of Nuclear Medicine, University College London and UCL Hospitals, NHS Trust, London, United Kingdom
3 shared publicationsLudmila Guralnik
Technion-Israel Institute of Technology
3 shared publicationsOra Israel
Rambam Health Care Campus
3 shared publicationsRayjanah Allie
Institute of Nuclear Medicine, University College London and UCL Hospitals, NHS Trust, London, United Kingdom
3 shared publicationsThida Win
University College London
3 shared publications
Latest Publications
- Open Access
- 14 March 2018
- Published by Springer Nature in EJNMMI Physics
- Vol. 5 (1) , 1-12
Feasibility study of a novel general purpose CZT-based digital SPECT camera: initial clinical results
The performance of a prototype novel digital single-photon emission computed tomography (SPECT) camera with multiple pixelated CZT detectors and high sensitivity collimators (Digital SPECT; Valiance X12 prototype, Molecular Dynamics) was evaluated in various clinical settings. Images obtained in the prototype system were compared to images from an analog camera fitted with high-resolution collimators. Clinical feasibility, image quality, and diagnostic performance of the prototype were evaluated in 36 SPECT studies in 35 patients including bone (n = 21), brain (n = 5), lung perfusion (n = 3), and parathyroid (n = 3) and one study each of sentinel node and labeled white blood cells. Images were graded on a scale of 1–4 for sharpness, contrast, overall quality, and diagnostic confidence. Digital CZT SPECT provided a statistically significant improvement in sharpness and contrast in clinical cases (mean score of 3.79 ± 0.61 vs. 3.26 ± 0.50 and 3.92 ± 0.29 vs. 3.34 ± 0.47 respectively, p < 0.001 for both). Overall image quality was slightly higher for the digital SPECT but not statistically significant (3.74 vs. 3.66). CZT SPECT provided significantly improved image sharpness and contrast compared to the analog system in the clinical settings evaluated. Further studies will evaluate the diagnostic performance of the system in large patient cohorts in additional clinical settings.
- 14 March 2018
- Published by Springer Nature in EJNMMI Physics
- Vol. 5 (1) , 1-12
Open AccessFeasibility study of a novel general purpose CZT-based digital SPECT camera: initial clinical results
The performance of a prototype novel digital single-photon emission computed tomography (SPECT) camera with multiple pixelated CZT detectors and high sensitivity collimators (Digital SPECT; Valiance X12 prototype, Molecular Dynamics) was evaluated in various clinical settings. Images obtained in the prototype system were compared to images from an analog camera fitted with high-resolution collimators. Clinical feasibility, image quality, and diagnostic performance of the prototype were evaluated in 36 SPECT studies in 35 patients including bone (n = 21), brain (n = 5), lung perfusion (n = 3), and parathyroid (n = 3) and one study each of sentinel node and labeled white blood cells. Images were graded on a scale of 1–4 for sharpness, contrast, overall quality, and diagnostic confidence. Digital CZT SPECT provided a statistically significant improvement in sharpness and contrast in clinical cases (mean score of 3.79 ± 0.61 vs. 3.26 ± 0.50 and 3.92 ± 0.29 vs. 3.34 ± 0.47 respectively, p < 0.001 for both). Overall image quality was slightly higher for the digital SPECT but not statistically significant (3.74 vs. 3.66). CZT SPECT provided significantly improved image sharpness and contrast compared to the analog system in the clinical settings evaluated. Further studies will evaluate the diagnostic performance of the system in large patient cohorts in additional clinical settings.
- 20 December 2017
- Published by Springer Nature in European Radiology
- Vol. 28 (6) , 2264-2272
Fat necrosis after abdominal surgery: A pitfall in interpretation of FDG-PET/CT
We describe FDG-PET/CT findings of postoperative fat necrosis in patients following abdominal surgery, and evaluate their changes in size and FDG uptake over time.
- 20 December 2017
- Published by Springer Nature in European Radiology
- Vol. 28 (6) , 2264-2272
Fat necrosis after abdominal surgery: A pitfall in interpretation of FDG-PET/CT
We describe FDG-PET/CT findings of postoperative fat necrosis in patients following abdominal surgery, and evaluate their changes in size and FDG uptake over time.
- 29 October 2017
- Published by Springer Nature
- p. 639-684
Diagnostic Applications of Nuclear Medicine: Lung and Mediastinal Tumors
- 29 October 2017
- Published by Springer Nature
- p. 639-684
Diagnostic Applications of Nuclear Medicine: Lung and Mediastinal Tumors
- 1 August 2017
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 24 (4) , 1347-1349
What are the necessary corrections for dynamic cardiac SPECT?
- 1 August 2017
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 24 (4) , 1347-1349
What are the necessary corrections for dynamic cardiac SPECT?
- 5 July 2017
- Published by Springer Nature
- p. 1-46
Diagnostic Applications of Nuclear Medicine: Lung and Mediastinal Tumors
- 5 July 2017
- Published by Springer Nature
- p. 1-46
Diagnostic Applications of Nuclear Medicine: Lung and Mediastinal Tumors
- 10 November 2016
- Published by Springer Nature
- p. 1-46
Lung and Mediastinal Tumors
- 1 July 2016
- Published by Elsevier in Seminars in Nuclear Medicine
- Vol. 46 (4) , 273-285
Novel Cadmium Zinc Telluride Devices for Myocardial Perfusion Imaging—Technological Aspects and Clinical Applications
- 1 July 2016
- Published by Elsevier in Seminars in Nuclear Medicine
- Vol. 46 (4) , 273-285
Novel Cadmium Zinc Telluride Devices for Myocardial Perfusion Imaging—Technological Aspects and Clinical Applications
- 1 April 2016
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 23 (2) , 301-310
Pitfalls and artifacts using the D-SPECT dedicated cardiac camera
- 1 April 2016
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 23 (2) , 301-310
Pitfalls and artifacts using the D-SPECT dedicated cardiac camera
- 1 June 2014
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 21 (3) , 478-485
Clinical value of supine and upright myocardial perfusion imaging in obese patients using the D-SPECT camera
- 1 June 2014
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 21 (3) , 478-485
Clinical value of supine and upright myocardial perfusion imaging in obese patients using the D-SPECT camera
- Open Access
- 11 April 2013
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 54 (6) , 873-879
Quantification of Myocardial Perfusion Reserve Using Dynamic SPECT Imaging in Humans: A Feasibility Study
Myocardial perfusion imaging (MPI) is well established in the diagnosis and workup of patients with known or suspected coronary artery disease (CAD); however, it can underestimate the extent of obstructive CAD. Quantification of myocardial perfusion reserve with PET can assist in the diagnosis of multivessel CAD. We evaluated the feasibility of dynamic tomographic SPECT imaging and quantification of a retention index to describe global and regional myocardial perfusion reserve using a dedicated solid-state cardiac camera. Methods: Ninety-five consecutive patients (64 men and 31 women; median age, 67 y) underwent dynamic SPECT imaging with 99mTc-sestamibi at rest and at peak vasodilator stress, followed by standard gated MPI. The dynamic images were reconstructed into 60–70 frames, 3–6 s/frame, using ordered-subsets expectation maximization with 4 iterations and 32 subsets. Factor analysis was used to estimate blood-pool time–activity curves, used as input functions in a 2-compartment kinetic model. K1 values (99mTc-sestamibi uptake) were calculated for the stress and rest images, and K2 values (99mTc-sestamibi washout) were set to zero. Myocardial perfusion reserve (MPR) index was calculated as the ratio of the stress and rest K1 values. Standard MPI was evaluated semiquantitatively, and total perfusion deficit (TPD) of at least 5% was defined as abnormal. Results: Global MPR index was higher in patients with normal MPI (n = 51) than in patients with abnormal MPI (1.61 [interquartile range (IQR), 1.33–2.03] vs. 1.27 [IQR, 1.12–1.61], P = 0.0002). By multivariable regression analysis, global MPR index was associated with global stress TPD, age, and smoking. Regional MPR index was associated with the same variables and with regional stress TPD. Sixteen patients undergoing invasive coronary angiography had 20 vessels with stenosis of at least 50%. The MPR index was 1.11 (IQR, 1.01–1.21) versus 1.30 (IQR, 1.12–1.67) in territories supplied by obstructed and nonobstructed arteries, respectively (P = 0.02). MPR index showed a stepwise reduction with increasing extent of obstructive CAD (P = 0.02). Conclusion: Dynamic tomographic imaging and quantification of a retention index describing global and regional perfusion reserve are feasible using a solid-state camera. Preliminary results show that the MPR index is lower in patients with perfusion defects and in regions supplied by obstructed coronary arteries. Further studies are needed to establish the clinical role of this technique as an aid to semiquantitative analysis of MPI.
- 11 April 2013
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 54 (6) , 873-879
Open AccessQuantification of Myocardial Perfusion Reserve Using Dynamic SPECT Imaging in Humans: A Feasibility Study
Myocardial perfusion imaging (MPI) is well established in the diagnosis and workup of patients with known or suspected coronary artery disease (CAD); however, it can underestimate the extent of obstructive CAD. Quantification of myocardial perfusion reserve with PET can assist in the diagnosis of multivessel CAD. We evaluated the feasibility of dynamic tomographic SPECT imaging and quantification of a retention index to describe global and regional myocardial perfusion reserve using a dedicated solid-state cardiac camera. Methods: Ninety-five consecutive patients (64 men and 31 women; median age, 67 y) underwent dynamic SPECT imaging with 99mTc-sestamibi at rest and at peak vasodilator stress, followed by standard gated MPI. The dynamic images were reconstructed into 60–70 frames, 3–6 s/frame, using ordered-subsets expectation maximization with 4 iterations and 32 subsets. Factor analysis was used to estimate blood-pool time–activity curves, used as input functions in a 2-compartment kinetic model. K1 values (99mTc-sestamibi uptake) were calculated for the stress and rest images, and K2 values (99mTc-sestamibi washout) were set to zero. Myocardial perfusion reserve (MPR) index was calculated as the ratio of the stress and rest K1 values. Standard MPI was evaluated semiquantitatively, and total perfusion deficit (TPD) of at least 5% was defined as abnormal. Results: Global MPR index was higher in patients with normal MPI (n = 51) than in patients with abnormal MPI (1.61 [interquartile range (IQR), 1.33–2.03] vs. 1.27 [IQR, 1.12–1.61], P = 0.0002). By multivariable regression analysis, global MPR index was associated with global stress TPD, age, and smoking. Regional MPR index was associated with the same variables and with regional stress TPD. Sixteen patients undergoing invasive coronary angiography had 20 vessels with stenosis of at least 50%. The MPR index was 1.11 (IQR, 1.01–1.21) versus 1.30 (IQR, 1.12–1.67) in territories supplied by obstructed and nonobstructed arteries, respectively (P = 0.02). MPR index showed a stepwise reduction with increasing extent of obstructive CAD (P = 0.02). Conclusion: Dynamic tomographic imaging and quantification of a retention index describing global and regional perfusion reserve are feasible using a solid-state camera. Preliminary results show that the MPR index is lower in patients with perfusion defects and in regions supplied by obstructed coronary arteries. Further studies are needed to establish the clinical role of this technique as an aid to semiquantitative analysis of MPI.