Sigrid Pillen
Sigrid Pillen has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Nens Van Alfen
Department of Neurology, Radboud university medical center, Nijmegen, The Netherlands
4 shared publicationsNens van Alfen
Radboud University Nijmegen Medical Center
2 shared publicationsAad Verrips
Department of Neurology Canisius Wilhelmina Hospital Nijmegen The Netherlands
1 shared publicationAndrea Boon
Department of Physical Medicine and Rehabilitation and Department of Neurology, Mayo Clinic, Rochester, MN, USA
1 shared publicationAnjo J.W.M. Janssen
Department of Rehabilitation, Pediatric Physical Therapy, Radboud University Medical Center Nijmegen, the Netherlands
1 shared publicationAnnet Van Royen‐Kerkhof
Department of Pediatric Rheumatology, Wilhelmina Children's Hospital, University Medical Center Utrecht, the Netherlands
1 shared publication
Latest Publications
- 20 February 2015
- Published by Wiley in Muscle & Nerve
- Vol. 52 (3) , 319-320
Muscle ultrasound from diagnostic tool to outcome measure—Quantification is the challenge
- 20 February 2015
- Published by Wiley in Muscle & Nerve
- Vol. 52 (3) , 319-320
Muscle ultrasound from diagnostic tool to outcome measure—Quantification is the challenge
- 30 December 2014
- Published by Wiley in Muscle & Nerve
- Vol. 52 (4) , 540-546
Quantitative muscle ultrasonography in the follow‐up of juvenile dermatomyositis
Introduction: We explored the use of quantitative muscle ultrasonography (QMUS) for follow‐up of juvenile dermatomyositis (JDM). Methods: Seven JDM patients were evaluated at diagnosis and 1, 3, 6, 12, and 24 months using the Childhood Myositis Assessment Scale (CMAS) and QMUS. Muscle thickness (MT) and quantitative muscle echo intensity (EI) were assessed with QMUS in 4 muscles. Results: Six patients experienced a monocyclic course. At diagnosis EI was slightly increased, and MT was relatively normal. After start of treatment MT first decreased and EI increased, with normalization of EI within 6–12 months (n = 4). One patient had higher EIs at diagnosis and slower normalization, indicating fibrosis, despite early normalization of CMAS. One patient experienced a chronic course, with high EIs and atrophy during follow‐up. Conclusions: QMUS can provide additional information for follow‐up of JDM regarding disease severity and residual muscle damage, particularly after normalization of CMAS. Muscle Nerve 52: 540–546, 2015
- 30 December 2014
- Published by Wiley in Muscle & Nerve
- Vol. 52 (4) , 540-546
Quantitative muscle ultrasonography in the follow‐up of juvenile dermatomyositis
Introduction: We explored the use of quantitative muscle ultrasonography (QMUS) for follow‐up of juvenile dermatomyositis (JDM). Methods: Seven JDM patients were evaluated at diagnosis and 1, 3, 6, 12, and 24 months using the Childhood Myositis Assessment Scale (CMAS) and QMUS. Muscle thickness (MT) and quantitative muscle echo intensity (EI) were assessed with QMUS in 4 muscles. Results: Six patients experienced a monocyclic course. At diagnosis EI was slightly increased, and MT was relatively normal. After start of treatment MT first decreased and EI increased, with normalization of EI within 6–12 months (n = 4). One patient had higher EIs at diagnosis and slower normalization, indicating fibrosis, despite early normalization of CMAS. One patient experienced a chronic course, with high EIs and atrophy during follow‐up. Conclusions: QMUS can provide additional information for follow‐up of JDM regarding disease severity and residual muscle damage, particularly after normalization of CMAS. Muscle Nerve 52: 540–546, 2015
- 10 May 2014
- Published by Wiley in Muscle & Nerve
- Vol. 51 (1) , 35-41
Ultrasound of the cervical roots and brachial plexus in neonates
Introduction: In this exploratory study we investigated whether ultrasound can visualize the neonatal cervical roots and brachial plexus. Methods: In 12 healthy neonates Results: The C5–C8 nerve roots and brachial plexus could be imaged with sufficient delineation of the root exits to assess their integrity. The brachial plexus was more difficult to discern from the surrounding area in neonates compared with adults, especially in the interscalene region because of the smaller amount of connective tissue in and surrounding muscles and nerves. In addition, the large deposits of brown fat make for a different ultrasound appearance of the neonatal neck compared with adults. Conclusions: Ultrasound of the neonatal cervical nerve roots is feasible and may be used as a non‐invasive screening technique to assess nerve root integrity in obstetric brachial plexus injury. Muscle Nerve 51: 35–41, 2015
- 10 May 2014
- Published by Wiley in Muscle & Nerve
- Vol. 51 (1) , 35-41
Ultrasound of the cervical roots and brachial plexus in neonates
Introduction: In this exploratory study we investigated whether ultrasound can visualize the neonatal cervical roots and brachial plexus. Methods: In 12 healthy neonates Results: The C5–C8 nerve roots and brachial plexus could be imaged with sufficient delineation of the root exits to assess their integrity. The brachial plexus was more difficult to discern from the surrounding area in neonates compared with adults, especially in the interscalene region because of the smaller amount of connective tissue in and surrounding muscles and nerves. In addition, the large deposits of brown fat make for a different ultrasound appearance of the neonatal neck compared with adults. Conclusions: Ultrasound of the neonatal cervical nerve roots is feasible and may be used as a non‐invasive screening technique to assess nerve root integrity in obstetric brachial plexus injury. Muscle Nerve 51: 35–41, 2015
- 27 September 2012
- Published by Wiley in Muscle & Nerve
- Vol. 47 (6) , 856-863
Quantitative muscle ultrasound and muscle force in healthy children: A 4‐year follow‐up study
Introduction: No longitudinal data on the normal development of muscle thickness (MT), quantitative muscle ultrasound echo intensity (EI), and muscle force (MF) in healthy children are yet available.Methods: Reference values of MT, EI, and MF of 4 muscles from infancy to age 16 years were established during a 4‐year follow‐up period and correlated with age and growth.Results: For most muscles, MT and MF correlated with growth and aging, with almost equal influences of weight and height. EI increased only slightly (1% per year) with height, weight, and age.Conclusions: To use these reference values for repeated measurements, MF and MT can be corrected for either weight or height. It does not seem necessary to correct EI for these factors during follow‐up of a few years. These results provide a basis for more precise detection of changes in muscle structure or force in neuromuscular disorders. Muscle Nerve 47: 856–863, 2013
- 27 September 2012
- Published by Wiley in Muscle & Nerve
- Vol. 47 (6) , 856-863
Quantitative muscle ultrasound and muscle force in healthy children: A 4‐year follow‐up study
Introduction: No longitudinal data on the normal development of muscle thickness (MT), quantitative muscle ultrasound echo intensity (EI), and muscle force (MF) in healthy children are yet available.Methods: Reference values of MT, EI, and MF of 4 muscles from infancy to age 16 years were established during a 4‐year follow‐up period and correlated with age and growth.Results: For most muscles, MT and MF correlated with growth and aging, with almost equal influences of weight and height. EI increased only slightly (1% per year) with height, weight, and age.Conclusions: To use these reference values for repeated measurements, MF and MT can be corrected for either weight or height. It does not seem necessary to correct EI for these factors during follow‐up of a few years. These results provide a basis for more precise detection of changes in muscle structure or force in neuromuscular disorders. Muscle Nerve 47: 856–863, 2013
- 1 December 2011
- Published by Taylor & Francis in Neurological Research
- Vol. 33 (10) , 1016-1024
Skeletal muscle ultrasound
Muscle ultrasound is a convenient technique to visualize normal and pathological muscle tissue as it is non-invasive and real-time. Neuromuscular disorders give rise to structural muscle changes that can be visualized with ultrasound: atrophy can be objectified by measuring muscle thickness, while infiltration of fat and fibrous tissue increases muscle echo intensity, i.e. the muscles become whiter on the ultrasound image. Muscle echo intensity needs to be quantified to correct for age-related increase in echo intensity and differences between individual muscles. This can be done by gray scale analysis, a method that can be easily applied in daily clinical practice. Using this technique, it is possible to detect neuromuscular disorders with predictive values of 90%. Only in young children and metabolic myopathies the sensitivity is lower. Ultrasound is a dynamic technique and therefore capable of visualizing normal and pathological muscle movements. Fasciculations can easily be differentiated from other muscle movements. Ultrasound appeared to be even more sensitive in detecting fasciculations compared to Electromyography (EMG) and clinical observations, because it can visualize a large muscle area and deeper located muscles. With improving resolution and frame rate it has recently become clear that also smaller scale spontaneous muscle activity such as fibrillations can be detected by ultrasound. This opens the way to a broader use of muscle ultrasound in the diagnosis of peripheral nerve and muscle disorders.
- 1 December 2011
- Published by Taylor & Francis in Neurological Research
- Vol. 33 (10) , 1016-1024
Skeletal muscle ultrasound
Muscle ultrasound is a convenient technique to visualize normal and pathological muscle tissue as it is non-invasive and real-time. Neuromuscular disorders give rise to structural muscle changes that can be visualized with ultrasound: atrophy can be objectified by measuring muscle thickness, while infiltration of fat and fibrous tissue increases muscle echo intensity, i.e. the muscles become whiter on the ultrasound image. Muscle echo intensity needs to be quantified to correct for age-related increase in echo intensity and differences between individual muscles. This can be done by gray scale analysis, a method that can be easily applied in daily clinical practice. Using this technique, it is possible to detect neuromuscular disorders with predictive values of 90%. Only in young children and metabolic myopathies the sensitivity is lower. Ultrasound is a dynamic technique and therefore capable of visualizing normal and pathological muscle movements. Fasciculations can easily be differentiated from other muscle movements. Ultrasound appeared to be even more sensitive in detecting fasciculations compared to Electromyography (EMG) and clinical observations, because it can visualize a large muscle area and deeper located muscles. With improving resolution and frame rate it has recently become clear that also smaller scale spontaneous muscle activity such as fibrillations can be detected by ultrasound. This opens the way to a broader use of muscle ultrasound in the diagnosis of peripheral nerve and muscle disorders.