HSHamdi Shukor

Hamdi Shukor

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hamdi Shukor has a total of 99 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Interfacial Microstructure and Mechanical Properties of SCh100 Cast Iron–St3sp Steel Macrocomposites via Lost-Foam Casting

    by Іvan Nebozhak, Adit Sharma, Oleg Shinsky, Volodymyr Doroshenko, Dmytro Verbylo, Ruslan A. Sergiienko, Valentyn Veis, Mariia Naumenko, Igor Khoroshko, Hamdi Shukor

    Gray cast iron offers excellent castability, machinability, and damping capacity; however, its tensile performance is limited by the stress-concentrating effect of flake graphite. This study investigates the interfacial microstructure and mechanical response of SCh100 gray cast iron macro-composites reinforced with two distinct St3sp steel configurations produced by lost-foam casting: a continuous Zn-coated wire and a perforated steel plate. Bulk chemical analysis, optical metallography, tensile testing, three-point bending, and Brinell hardness measurements were conducted. The wire-reinforced composite exhibited continuous matrix-reinforcement contact under optical examination and a distinct interfacial transition region approximately 140-160 μm thick, accompanied by a broader microstructurally modified region extending into the steel reinforcement. In contrast, the plate-reinforced composite exhibited localized matrix-plate gaps ranging from approximately 5 to 200 μm in the examined cross-sections. The ultimate tensile strength increased from 82.9 MPa for the control casting to 99.5 MPa and 88.7 MPa for the wire-reinforced and plate-reinforced composites, respectively. Similarly, the maximum flexural stress increased from 137.3 MPa for the control material to 239.5 MPa and 197.2 MPa for the wire-reinforced and plate-reinforced composites, respectively. These findings demonstrate a clear association between reinforcement configuration, interfacial contact quality, local microstructural modification, and macroscopic mechanical performance. The continuous Zn-coated wire architecture established a seamless metallurgical bond via transient interfacial fluxing and controlled carbon diffusion. This yielded a 20.0% enhancement in ultimate tensile strength (99.5 MPa) and a 74.4% increase in maximum flexural stress (239.5 MPa) compared to unreinforced SCh100 gray cast iron

  • Open Access

    Microalloying and Cryomilling Effects on Phase Stability and Magnetostructural Transitions in Melt-Spun Mn₅₂Al₄₅V₃ Ribbons

    by Adit Sharma, Mikhail Gorshenkov, K.S. Nechaev, Dmitriy Karpenkov, Anastasiya Fortuna, N.M. Vazhinskii, Aleksey V. Maksimkin, Hamdi Shukor

    Metastable Mn52Al45V3 ribbons were synthesized via melt spinning, followed by controlled annealing and cryomilling, to investigate the synergistic interplay of microalloying, defect engineering, and phase transformation kinetics. Quantitative Rietveld refinement revealed that the as-spun ribbon contained 43.6 ± 2.2 vol.% ferromagnetic τ-phase (L1₀) and 56.4 ± 2.2 vol.% metastable ε-phase. Isothermal annealing at 450 °C for 30 min promoted a diffusion-controlled ε → τ transformation, increasing the τ-phase fraction to 68.1 ± 1.6 vol.% while achieving a maximum magnetization (Mmax) of 74 emu/g at 20 kOe and a coercivity (Hc) of 0.75 kOe. High-energy cryomilling at 30 Hz induced significant lattice strain and mechanical amorphization, driving the stress-induced decomposition of L1₀ τ-phase into non-magnetic β-Mn (59.1 ± 2.1 vol.%) and γ₂ phases, which reduced Mmax below 20 emu/g. Thermomagnetic analysis revealed an anomalous apparent thermal hysteresis of ΔT = 136 °C during the initial heating cycle, driven by single-stage, irreversible defect annihilation and microstrain relaxation. Following structural relaxation, a reversible first-order magnetostructural transition was stabilized with a narrow thermal hysteresis of ΔT ≈ 1 °C. Transmission electron microscopy identified coherent nanoscale ε'-phase domains (5–15 nm), providing the atomic-scale origin of the phase metastability. These results establish a framework for defect-tailored processing of rare-earth-free permanent magnetic materials.

  • Evolution of Iron-Based Metallic Glass Composite Coating with Enhanced Corrosion Resistance and Biocompatibility

    by Mahmoud Z. Ibrahim, A. A. D. Sarhan, T. Y. Kuo, Farazila Yusof, M. Hamdi, C. P. Chang, T. M. Lee, C. S. Chien


  • In-vitro viability of laser cladded Fe-based metallic glass as a promising bioactive material for improved osseointegration of orthopedic implants

    by Mahmoud Z. Ibrahim, Ahmed Halilu, Ahmed A.D. Sarhan, T.Y. Kuo, Farazila Yusuf, M.O. Shaikh, M. Hamdi

    The commonly used metallic biomaterials fail to prove durability for orthopedics due to their lack of biocompatibility and poor bioactivity which weakens the bonding to bones. Metallic glasses (MGs) have attracted attention as an alternative biomaterial for orthopedics owing to their superior mechanical properties and acceptable biocompatibility. Nevertheless, their uses are limited due to geometrical constraints and brittleness. In this research, the in-vitro bioactivity of laser cladded FeCrMoCB MG on nickel-free stainless-steel was investigated. The proposed MG coating exhibited a remarkable in-vitro bioactivity behavior without prior treatment after immersion in simulated body fluid which is a key factor for better osseointegration. The surface morphology showed that apatite nucleated from the first day and completely covered the surface after 21 days. The energy dispersive spectroscopy spectra showed an increase in the Ca/P ratio from 0.51 at 3 days to 1.61 at 21 days, thus approaching the stoichiometric ratio of bone apatite. The infra-red examination revealed the existence of Ca+2, PO4-2 and OH- indicating the nucleation of brushite and B-type apatite. Additionally, the X-ray diffraction examination revealed the existence of amorphous and nanocrystalline calcium phosphates. These results show the potential of FeCrMoCB MGs as a promising bioactive coating for excellent osseointegration of metallic implants with bone tissue.


  • Open Access

    In vitro evaluation of novel low-pressure spark plasma sintered HA–BG composite scaffolds for bone tissue engineering

    by Muhammad Rizwan, Krishnamurithy Genasan, Malliga Raman Murali, Hanumantha Rao Balaji Raghavendran, Rodianah Alias, Yi Ying Cheok, Won Fen Wong, Azura Mansor, M. Hamdi, Wan Jeffrey Basirun, et al.

    The low-pressure spark plasma sintering (SPS) technique is adopted to fabricate hydroxyapatite–bioglass (HA–BG) scaffolds while maintaining the physical properties of both components, including their bulk and relative density and hardness. However, prior to their orthopaedic and dental applications, these scaffolds must be validated via pre-clinical assessments. In the present study, scaffolds with different ratios of HA : BG, namely, 100 : 0 (HB 0 S), 90 : 10 (HB 10 S), 80 : 20 (HB 20 S) and 70 : 30 (HB 30 S) were fabricated. These scaffolds were characterized by investigating their physicochemical properties (X-ray diffraction (XRD) and surface wettability), bioactivity in a simulated body fluid (SBF) (field emission scanning electron microscopy (FESEM), Fourier-transform infrared spectroscopy (FTIR) and calcium dissolution), antimicrobial properties, biocompatibility and osteoinduction of human bone marrow-derived mesenchymal stromal cells (hBMSCs) and human monocyte immune cell response. The XRD and surface wettability results confirmed no formation of undesirable phases and the enhanced surface hydrophilicity of the scaffolds, respectively. The bioactivity in SBF indicated the formation of bone-like apatite on the surface of the scaffolds, corresponding to an increase in BG%, which was confirmed through FTIR spectra and the increasing trend of calcium release in SBF. The scaffolds showed inhibition properties against Staphylococcus aureus and Staphylococcus epidermidis. The scanning electron microscopy (SEM) micrographs and Alamar Blue proliferation assay indicated the good attachment and significant proliferation, respectively, of hBMSCs on the scaffolds. Alizarin Red S staining confirmed that the scaffolds supported the mineralisation of hBMSCs. The osteogenic protein secretion (bone morphogenetic protein-2 (BMP2), type-I collagen (COL1) and osterix (OSX)) was significant on the HB 30 S-seeded hBMSCs when compared with that of HB 0 S. The monocyte migration was significantly halted in response to HA–BG-conditioned media when compared with the positive control (monocyte chemoattractant protein-1: MCP-1). In conclusion, the HB 30 S composite scaffold has a greater potential to substitute bone grafts in orthopaedic and dental applications.


  • Effect of focused ion beam process parameter on Tin-Nickel-Copper micropillars microfabrication

    by N. Syahira M. Annuar, Reza Mahmoodian, Mohd Hamdi Abd Shukor

    In this work, the mechanism of focused ion beam (FIB) milling as an advanced manufacturing technique is studied to pattern micropillars at different diameter sizes of 5, 10 and 20 μm. Under the same type of ion source which is Ga ion, the main ion beam parameters that influenced the FIB machining to produce micropillars are the ion beam scanning, dose, profile, and incident angle. The mathematical modeling is presented to describe the micropillars’ production by crater sputtering of the FIB milling. The effect of sputtering and redeposition on the final geometrical micropillars suggest the arrangement of the multilayer sample (Sn/Ni/Cu) that close to the ion irradiation gets highly sputtered and redeposited despite the surface binding energy and sputtering yield, ϒ of each element is known. Results show that the highest aspect ratio values are derived from the lowest diameter size of the micropillars produced from the FIB machining.


  • Study the effect of thermal annealing on adhesion strength of Silver-Tantalum Oxide thin film deposited by reactive magnetron sputtering

    by Rodianah Alias, Reza Mahmoodian, Muhammad Rizwan, Mohd Hamdi Abd Shukor

    Stainless steel (SS) are extensively used for healthcare, hygiene and surgical applications due to their excellent corrosion resistance and adequate mechanical strength. Among this class SS 316 L is employed most widely, due to highest corrosion resistance, good mechanical properties, resistance to sensitization and ease of fabrication. To incorporate antimicrobial characteristic in SS 316 L based surgical tools a nanocomposite layer comprising of Silver (Ag) and Tantalum oxide (TaxOx) has been deposited by using Physical Vapor Deposition (PVD) magnetron sputtering. Delamination of ceramic layers on SS 316 L substrate is one of the major limitation arising from insufficient crystallization and poor adhesion strength. PVD magnetron sputtering has been employed to develop 5.49 µm thick Ag-TaxOx nanocomposite layer on SS 316 L. Substantially improved adhesion strength has been achieved by controlling thermal treatment. The microstructure, surface and phase analysis of as-sputtered and annealed thin films has been carried out to determine the characteristics of the developed layer. A nanocomposite layer on SS 316 L substrate comprising of Ag and TaxOx has been achieved by releasing O2 during deposition. Thermal treatment was performed at 300, 400, 500 and 600 °C which progressively increased the crystallinity and segregation of Ag at the surface. Highest adhesion strength was achieved by annealing the coated samples at 400 °C, which exhibited four-fold increased adhesion strength when compared to as-deposited layer. The precipitation of a new phase Silver tantalum oxide (AgTaO3) was observed for the samples annealed at temperature above 400 °C, which may be responsible for the decrease in adhesion strength.


  • Open Access

    Effects of Sample and Indenter Configurations of Nanoindentation Experiment on the Mechanical Behavior and Properties of Ductile Materials

    by Seyed Saeid Rahimian Koloor, Atefeh Karimzadeh, Mohd Nasir Tamin, Mohd Hamdi Abd Shukor

    The nanoindentation test is frequently used as an alternate method to obtain the mechanical properties of ductile materials. However, due to the lack of information about the effects of the sample and indenter physical configurations, the accuracy of the extracted material properties in nanoindentation tests requires further evaluation that has been considered in this study. In this respect, a demonstrator ductile material, aluminum 1100, was tested using the Triboscope nanoindenter system with the Berkovich indenter. A 3D finite element simulation of the nanoindentation test was developed and validated through exact prediction of the structural response with measured data. The validated model was then employed to examine the effects of various test configurations on the load–displacement response of the sample material. These parameters were the different indenter edge-tip radii, different indentation depths, different sample tilts, and different friction conditions between the indenter and the material surface. Within the range of the indenter edge-tip radii examined, the average elastic modulus and hardness were 78.34 ± 14.58 and 1.6 ± 0.24 GPa, respectively. The different indentation depths resulted in average values for the elastic modulus and hardness of 77.03 ± 6.54 and 1.58 ± 0.17 GPa, respectively. The uneven surface morphology, as described by the inclination of the local indentation plane, indicated an exponential increase in the extracted values of elastic modulus and hardness, ranging from 71.83 and 1.47 GPa (for the reference case, θ = 0°) to 243.39 and 5.05 GPa at θ = 12°. The mechanical properties that were obtained through nanoindentation on the surface with 6° tilt or higher were outside the range for aluminum properties. The effect of friction on the resulting mechanical response and the properties of the material was negligible.


  • Surface modification of valve metals using plasma electrolytic oxidation for antibacterial applications: A review

    by Muhammad Rizwan, Rodianah Alias, Umi Zhalilah Zaidi, Reza Mahmoodian, Mohd Hamdi

    Plasma electrolytic oxidation (PEO) is an advance technique to develop porous oxidation layer on light metals, primarily to enhance corrosion and wear resistance. The oxidation layer can also offer a wide variety of mechanical, biomedical, tribological, and antibacterial properties through the incorporation of several ions and particles. Due to the increasing need of antimicrobial surfaces for biomedical implants, antibacterial PEO coatings have been developed through the incorporation of antibacterial agents. Metallic nanoparticles that have been employed most widely as antibacterial agents are reported to demonstrate serious health and environmental threats. To overcome the current limitations of these coatings, there is a significant need to develop antibacterial surfaces that are not harmful for patient's health and environment. Attention of the readers has been directed to utilize bioactive glasses as antibacterial agents for PEO coatings. Bioactive glasses are well known for their excellent bioactivity, biocompatibility, and antibacterial character. PEO coatings incorporated with bioactive glasses can provide environment‐friendly antimicrobial surfaces with exceptional bioactivity, biocompatibility, and osseointegration. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 590–605, 2018.