Renato Tozzoli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Renato Tozzoli has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Danilo Villalta
Immunologia e Allergologia, Ospedale. S.Maria degli Angeli, Pordenone, Italy
4 shared publications - Nicola Bizzaro
Laboratorio di Patologia Clinica, Ospedale Civile, S. Donà di Piave, Italy
4 shared publications E Tonutti
3 shared publicationsF Manoni
3 shared publicationsA Piazza
2 shared publicationsD Bassetti
2 shared publications
Latest Publications
- Open Access
- 13 July 2012
- Published by Springer Nature in Autoimmunity Highlights
- Vol. 3 (2) , 59-65
Automation in indirect immunofluorescence testing: a new step in the evolution of the autoimmunology laboratory
Indirect immunofluorescence (IIF) plays an important role in immunological and immunometric assays for detecting and measuring autoantibodies. This technology was the first multiplex method used to detect cardinal autoantibodies for the diagnosis of autoimmune diseases. Over the last 20 years, research has enabled the progressive identification of cell and tissue autoantigens which are the target of autoantibodies originally detected by IIF. Accordingly, newer immunometric methods, capable of measuring concentrations of specific autoantibodies directed against these autoantigens, allowed for a gradual replacement of the IIF method in the autoimmunology laboratory. Currently, IIF remains the method of choice only in selected fields of autoimmune diagnostics. Following the recent statement by the American College of Rheumatology that the IIF technique should be considered as the standard screening method for the detection of ANA, the biomedical industry has developed technological solutions which significantly improve automation of the procedure, not only in the preparation of substrates and slides, but also in microscope reading. This review summarizes the general and specific features of new available commercial systems (Aklides, Medipan; Nova View, Inova; Zenit G Sight, A. Menarini Diagnostics; Europattern, Euroimmun; Helios, Aesku.Diagnostics; Image Navigator, Immuno Concepts; Cytospot, Autoimmun Diagnostika) for automation of the IIF method. The expected advantages of automated IIF are the reduction in frequency of false negative and false positive results, the reduction of intra- and inter-laboratory variability, the improvement of correlation of staining patterns with corresponding autoantibody reactivities, and higher throughput in the laboratory workflow.
- 13 July 2012
- Published by Springer Nature in Autoimmunity Highlights
- Vol. 3 (2) , 59-65
Open AccessAutomation in indirect immunofluorescence testing: a new step in the evolution of the autoimmunology laboratory
Indirect immunofluorescence (IIF) plays an important role in immunological and immunometric assays for detecting and measuring autoantibodies. This technology was the first multiplex method used to detect cardinal autoantibodies for the diagnosis of autoimmune diseases. Over the last 20 years, research has enabled the progressive identification of cell and tissue autoantigens which are the target of autoantibodies originally detected by IIF. Accordingly, newer immunometric methods, capable of measuring concentrations of specific autoantibodies directed against these autoantigens, allowed for a gradual replacement of the IIF method in the autoimmunology laboratory. Currently, IIF remains the method of choice only in selected fields of autoimmune diagnostics. Following the recent statement by the American College of Rheumatology that the IIF technique should be considered as the standard screening method for the detection of ANA, the biomedical industry has developed technological solutions which significantly improve automation of the procedure, not only in the preparation of substrates and slides, but also in microscope reading. This review summarizes the general and specific features of new available commercial systems (Aklides, Medipan; Nova View, Inova; Zenit G Sight, A. Menarini Diagnostics; Europattern, Euroimmun; Helios, Aesku.Diagnostics; Image Navigator, Immuno Concepts; Cytospot, Autoimmun Diagnostika) for automation of the IIF method. The expected advantages of automated IIF are the reduction in frequency of false negative and false positive results, the reduction of intra- and inter-laboratory variability, the improvement of correlation of staining patterns with corresponding autoantibody reactivities, and higher throughput in the laboratory workflow.
- 1 December 2008
- Published by Elsevier in Autoimmunity Reviews
- Vol. 8 (2) , 112-115
Infections and autoimmune thyroid diseases: Parallel detection of antibodies against pathogens with proteomic technology
- 1 December 2008
- Published by Elsevier in Autoimmunity Reviews
- Vol. 8 (2) , 112-115
Infections and autoimmune thyroid diseases: Parallel detection of antibodies against pathogens with proteomic technology
- 1 January 2008
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 46 (5) , 577-587
The diagnostic role of autoantibodies in the prediction of organ-specific autoimmune diseases
Due to their pathogenetic role, many serum autoantibodies can be detected a long time before the clinical onset and during the course of organ-specific autoimmune diseases. For these reasons, autoantibodies can be used as predictive markers of an ongoing disease (in healthy subjects) and of disease activity and severity (in ill patients). The new multiplex diagnostic technologies introduced recently in laboratory medicine allow the simultaneous detection of several different autoantibodies and can be used for screening purposes in open populations or high-risk groups. This review examines the various autoantibodies of demonstrated predictive role in organ-specific autoimmune diseases and it introduces the state-of-the-art in the detection of multiple autoantibodies with proteomic systems.
- 1 January 2008
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 46 (5) , 577-587
The diagnostic role of autoantibodies in the prediction of organ-specific autoimmune diseases
Due to their pathogenetic role, many serum autoantibodies can be detected a long time before the clinical onset and during the course of organ-specific autoimmune diseases. For these reasons, autoantibodies can be used as predictive markers of an ongoing disease (in healthy subjects) and of disease activity and severity (in ill patients). The new multiplex diagnostic technologies introduced recently in laboratory medicine allow the simultaneous detection of several different autoantibodies and can be used for screening purposes in open populations or high-risk groups. This review examines the various autoantibodies of demonstrated predictive role in organ-specific autoimmune diseases and it introduces the state-of-the-art in the detection of multiple autoantibodies with proteomic systems.
- 5 June 2007
- Vol. 25 (2) , 268-74
Antiprothrombin antibodies: a comparative analysis of homemade and commercial methods. A collaborative study by the Forum Interdisciplinare per la Ricerca nelle Malattie Autoimmuni (FIRMA).
Prothrombin (PT) is a target for antibodies with lupus anticoagulant (LA) activity, suggesting the possible application of anti-prothrombin antibody (aPT) assays in patients with antiphospholipid syndrome (APS). Different methods - both homemade and commercial - for the detection of aPT are available, but they seem to produce conflicting results. The purpose of this study was to compare the performance of different assays on a set of well-characterized serum samples. Sera were gathered from 4 FIRMA institutions, and distributed to 15 participating centres. Forty-five samples were from patients positive for LA and/or anticardiolipin antibodies (aCL) with or without APS, and 15 were from rheumatoid arthritis (RA) patients negative for antiphospholipid antibodies. The samples were evaluated for IgG and IgM antibodies using a homemade direct aPT assay (method 1), a homemade phosphatidylserine-dependent aPT assay (aPS/PT, method 2), and two different commercial kits (methods 3 and 4). In addition, a commercial kit for the detection of IgG-A-M aPT (method 5) was used. Inter-laboratory results for the 5 methods were not always comparable when different methods were used. Good inter-assay concordance was found for IgG antibodies evaluated using methods 1, 3, and 4 (Cohen k > 0.4), while the IgM results were discordant between assays. In patients with thrombosis and pregnancy losses, method 5 performed better than the others. While aPT and aPS/PT assays could be of interest from a clinical perspective, their routine performance cannot yet be recommended because of problems connected with the reproducibility and interpretation of the results.
- 5 June 2007
- Vol. 25 (2) , 268-74
Antiprothrombin antibodies: a comparative analysis of homemade and commercial methods. A collaborative study by the Forum Interdisciplinare per la Ricerca nelle Malattie Autoimmuni (FIRMA).
Prothrombin (PT) is a target for antibodies with lupus anticoagulant (LA) activity, suggesting the possible application of anti-prothrombin antibody (aPT) assays in patients with antiphospholipid syndrome (APS). Different methods - both homemade and commercial - for the detection of aPT are available, but they seem to produce conflicting results. The purpose of this study was to compare the performance of different assays on a set of well-characterized serum samples. Sera were gathered from 4 FIRMA institutions, and distributed to 15 participating centres. Forty-five samples were from patients positive for LA and/or anticardiolipin antibodies (aCL) with or without APS, and 15 were from rheumatoid arthritis (RA) patients negative for antiphospholipid antibodies. The samples were evaluated for IgG and IgM antibodies using a homemade direct aPT assay (method 1), a homemade phosphatidylserine-dependent aPT assay (aPS/PT, method 2), and two different commercial kits (methods 3 and 4). In addition, a commercial kit for the detection of IgG-A-M aPT (method 5) was used. Inter-laboratory results for the 5 methods were not always comparable when different methods were used. Good inter-assay concordance was found for IgG antibodies evaluated using methods 1, 3, and 4 (Cohen k > 0.4), while the IgM results were discordant between assays. In patients with thrombosis and pregnancy losses, method 5 performed better than the others. While aPT and aPS/PT assays could be of interest from a clinical perspective, their routine performance cannot yet be recommended because of problems connected with the reproducibility and interpretation of the results.
- 1 June 2007
- Published by Elsevier in Autoimmunity Reviews
- Vol. 6 (6) , 334-340
Recent advances in diagnostic technologies and their impact in autoimmune diseases
- 1 June 2007
- Published by Elsevier in Autoimmunity Reviews
- Vol. 6 (6) , 334-340
Recent advances in diagnostic technologies and their impact in autoimmune diseases
- 1 October 2001
- Vol. 92 (10) , 609-17
[Laboratory diagnosis of autoimmune thyroid disease].
Assay of the anti-thyroperoxidase (TPO), anti-thyroglobulin (Tg), and anti-TSH receptor antibodies constitutes the basis of the laboratory diagnostic work-up for autoimmune thyroid diseases. However, although these antibodies have been routinely assayed in serum for more than 40 years with increasingly reliable methods, it still exists a wide analytical variability that influences their correct diagnostic use. We analysed the biochemical, physiopathological and clinical aspects of the thyroid antigen-anti body systems, and propose the following guidelines for using autoantibody tests and analytical assay methods: a) assay of anti-TPO with third generation ultrasensitive method should constitute the main test for the diagnosis of autoimmune thyroid diseases. Assay of anti-M antibodies should be considered obsolete because even purified microsome preparations contain traces of contaminants (Tg and other antigens) that make the test aspecific; b) assay of anti-Tg antibodies may be limited to patients with suspect AITD and negative for anti-TPO antibodies, and patients undergoing thyroglobulin assay, because anti-Tg autoantibodies may interfere in the assay of the molecule in the immunometric test; c) assay of the anti-TSH receptor antibodies is used to diagnose Basedow's disease, and atrophic chronic thyroiditis; d) it is appropriate to use normal reference values adjusted for age and gender.
- 1 October 2001
- Vol. 92 (10) , 609-17
[Laboratory diagnosis of autoimmune thyroid disease].
Assay of the anti-thyroperoxidase (TPO), anti-thyroglobulin (Tg), and anti-TSH receptor antibodies constitutes the basis of the laboratory diagnostic work-up for autoimmune thyroid diseases. However, although these antibodies have been routinely assayed in serum for more than 40 years with increasingly reliable methods, it still exists a wide analytical variability that influences their correct diagnostic use. We analysed the biochemical, physiopathological and clinical aspects of the thyroid antigen-anti body systems, and propose the following guidelines for using autoantibody tests and analytical assay methods: a) assay of anti-TPO with third generation ultrasensitive method should constitute the main test for the diagnosis of autoimmune thyroid diseases. Assay of anti-M antibodies should be considered obsolete because even purified microsome preparations contain traces of contaminants (Tg and other antigens) that make the test aspecific; b) assay of anti-Tg antibodies may be limited to patients with suspect AITD and negative for anti-TPO antibodies, and patients undergoing thyroglobulin assay, because anti-Tg autoantibodies may interfere in the assay of the molecule in the immunometric test; c) assay of the anti-TSH receptor antibodies is used to diagnose Basedow's disease, and atrophic chronic thyroiditis; d) it is appropriate to use normal reference values adjusted for age and gender.
- 1 October 2000
- Vol. 46 (10) , 1681-5
Sensitivity and specificity of immunological methods for the detection of anti-topoisomerase I (Scl70) autoantibodies: results of a multicenter study. The Italian Society of Laboratory Medicine Study Group on the Diagnosis of Autoimmune diseases.
The ability of immunometric methods to identify anti-topoisomerase I (Scl70) antibodies is controversial. We wished to quantify the performance of the currently available commercial systems for the assay of anti-topoisomerase I antibodies in a large multicenter study. Fifty Italian clinical laboratories analyzed 36 serum samples: 27 from individuals with scleroderma/systemic sclerosis, and 9 from a control group. The scleroderma/systemic sclerosis samples were positive in our laboratories by both ELISA and immunoblot (IB), and the control samples were negative. The laboratories used 42 immunoenzymatic (ELISA), 21 IB, 3 counterimmunoelectrophoresis, and 2 dot-blot methods, produced by 23 different manufacturers. We obtained 2389 results. The ELISA methods showed 99.2% specificity and 97.2% sensitivity for detection of anti-Scl70 antibodies. For IB methods, specificity was 97.6% and sensitivity was 96.1%. The Western-blot method had poor analytical specificity (27% false positives for anti-extractable nuclear antigen antibodies other than anti-Scl70). Excluding Western blots, commercial ELISA and IB reagents as used in clinical laboratories have a sensitivity and a specificity >95% for determination of anti-Scl70 antibodies.
- 1 October 2000
- Vol. 46 (10) , 1681-5
Sensitivity and specificity of immunological methods for the detection of anti-topoisomerase I (Scl70) autoantibodies: results of a multicenter study. The Italian Society of Laboratory Medicine Study Group on the Diagnosis of Autoimmune diseases.
The ability of immunometric methods to identify anti-topoisomerase I (Scl70) antibodies is controversial. We wished to quantify the performance of the currently available commercial systems for the assay of anti-topoisomerase I antibodies in a large multicenter study. Fifty Italian clinical laboratories analyzed 36 serum samples: 27 from individuals with scleroderma/systemic sclerosis, and 9 from a control group. The scleroderma/systemic sclerosis samples were positive in our laboratories by both ELISA and immunoblot (IB), and the control samples were negative. The laboratories used 42 immunoenzymatic (ELISA), 21 IB, 3 counterimmunoelectrophoresis, and 2 dot-blot methods, produced by 23 different manufacturers. We obtained 2389 results. The ELISA methods showed 99.2% specificity and 97.2% sensitivity for detection of anti-Scl70 antibodies. For IB methods, specificity was 97.6% and sensitivity was 96.1%. The Western-blot method had poor analytical specificity (27% false positives for anti-extractable nuclear antigen antibodies other than anti-Scl70). Excluding Western blots, commercial ELISA and IB reagents as used in clinical laboratories have a sensitivity and a specificity >95% for determination of anti-Scl70 antibodies.
- 1 November 1999
- Vol. 90 (11) , 579-84
[Detection of anti-ENA autoantibodies in patients with systemic connective tissue diseases. Analytical variability and diagnostic sensitivity of 4 methods].
This study was designed to assess the analytical sensitivity and rate of agreement between commercial methods and reagents, among the most used in Italy for the detection of autoantibodies to extractable nuclear antigens (ENA). Sixty-eight serum samples from patients with clinically diagnosed systemic rheumatic diseases were aliquoted and distributed to 4 hospital laboratories; three ELISA (Elias, Shield, Inova) and 1 immunoblot method (Euroimmun) were used. Overall agreement between the test reagents, for each anti-ENA specificity, was 69.1% for Ro/SSA, 83.3% for La/SSB, 70.6% for RNP, 73.5% for Sm, 91.1% for Jo1, and 82.3% for Scl70. Lack of specificity (i.e., false positive reactions) was the most important cause of low concordance. When the data were analysed according to the clinical diagnosis, total agreement and specificity improved. However, a significant difference in terms of sensitivity was observed in the SLE group (30 sera) for RNP (positivity ranged from 20% to 43%) and for Sm (from 7% to 37%), and in the Sjögren's syndrome group (13 sera) for anti-La/SSB (from 8% to 38%). Comparable data were obtained for anti-Ro/SSA (from 70% to 77%) both in the SLE and the Sjögren's syndrome group. Sensitivity of all 4 reagents was good in detecting anti-Scl70 autoantibodies in the 8 patients with diffuse systemic sclerosis, as well as anti-Jo1 autoantibody in the 5 polymyositis patients, with a 100% and a 95% agreement, respectively. These data suggest the need of a better standardization of commercial reagents and analytical procedures, and the opportunity that every laboratory should perform anti-ENA determination by at least two different methods, since none of the methods tested was completely reliable in detecting all anti-ENA autoantibody specificities.
- 1 November 1999
- Vol. 90 (11) , 579-84
[Detection of anti-ENA autoantibodies in patients with systemic connective tissue diseases. Analytical variability and diagnostic sensitivity of 4 methods].
This study was designed to assess the analytical sensitivity and rate of agreement between commercial methods and reagents, among the most used in Italy for the detection of autoantibodies to extractable nuclear antigens (ENA). Sixty-eight serum samples from patients with clinically diagnosed systemic rheumatic diseases were aliquoted and distributed to 4 hospital laboratories; three ELISA (Elias, Shield, Inova) and 1 immunoblot method (Euroimmun) were used. Overall agreement between the test reagents, for each anti-ENA specificity, was 69.1% for Ro/SSA, 83.3% for La/SSB, 70.6% for RNP, 73.5% for Sm, 91.1% for Jo1, and 82.3% for Scl70. Lack of specificity (i.e., false positive reactions) was the most important cause of low concordance. When the data were analysed according to the clinical diagnosis, total agreement and specificity improved. However, a significant difference in terms of sensitivity was observed in the SLE group (30 sera) for RNP (positivity ranged from 20% to 43%) and for Sm (from 7% to 37%), and in the Sjögren's syndrome group (13 sera) for anti-La/SSB (from 8% to 38%). Comparable data were obtained for anti-Ro/SSA (from 70% to 77%) both in the SLE and the Sjögren's syndrome group. Sensitivity of all 4 reagents was good in detecting anti-Scl70 autoantibodies in the 8 patients with diffuse systemic sclerosis, as well as anti-Jo1 autoantibody in the 5 polymyositis patients, with a 100% and a 95% agreement, respectively. These data suggest the need of a better standardization of commercial reagents and analytical procedures, and the opportunity that every laboratory should perform anti-ENA determination by at least two different methods, since none of the methods tested was completely reliable in detecting all anti-ENA autoantibody specificities.