Manh Hoang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Manh Hoang has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Zongli Xie
CSIRO Manufacturing, Private Bag 10, Clayton South, VIC 3169, Australia
4 shared publications Anita J. Hill
CSIRO Material Science and Engineering, Clayton, Australia
2 shared publications- Derrick Ng
CSIRO Manufacturing Clayton South Australia
2 shared publications Feng Hua She
Institute for Frontier Materials, Deakin University, Waurn Ponds, Australia
2 shared publications- Juan Zhang
Institute for Polymer Composites, Jiangsu University of Technology, Changzhou 213001, China
2 shared publications - Lingxue Kong
Institute for Frontier Materials, Deakin University, Waurn Ponds, Geelong, Vic 3216, Australia
2 shared publications
Latest Publications
- Open Access
- 3 September 2018
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 15 (9) , 1913
Study of Hybrid PVA/MA/TEOS Pervaporation Membrane and Evaluation of Energy Requirement for Desalination by Pervaporation
Desalination by pervaporation is a membrane process that is yet to be realized for commercial application. To investigate the feasibility and viability of scaling up, a process engineering model was developed to evaluate the energy requirement based on the experimental study of a hybrid polyvinyl alcohol/maleic acid/tetraethyl orthosilicate (PVA/MA/TEOS) Pervaporation Membrane. The energy consumption includes the external heating and cooling required for the feed and permeate streams, as well as the electrical power associated with pumps for re-circulating feed and maintaining vacuum. The thermal energy requirement is significant (e.g., up to 2609 MJ/m3 of thermal energy) and is required to maintain the feed stream at 65 °C in recirculation mode. The electrical energy requirement is very small (3 of required at 65 °C feed temperature at steady state) with the vacuum pump contributing to the majority of the electrical energy. The energy required for the pervaporation process was also compared to other desalination processes such as Reverse Osmosis (RO), Multi-stage Flash (MSF), and Multiple Effect Distillation (MED). The electrical energy requirement for pervaporation is the lowest among these desalination technologies. However, the thermal energy needed for pervaporation is significant. Pervaporation may be attractive when the process is integrated with waste heat and heat recovery option and used in niche applications such as RO brine concentration or salt recovery.
- 3 September 2018
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 15 (9) , 1913
Open AccessStudy of Hybrid PVA/MA/TEOS Pervaporation Membrane and Evaluation of Energy Requirement for Desalination by Pervaporation
Desalination by pervaporation is a membrane process that is yet to be realized for commercial application. To investigate the feasibility and viability of scaling up, a process engineering model was developed to evaluate the energy requirement based on the experimental study of a hybrid polyvinyl alcohol/maleic acid/tetraethyl orthosilicate (PVA/MA/TEOS) Pervaporation Membrane. The energy consumption includes the external heating and cooling required for the feed and permeate streams, as well as the electrical power associated with pumps for re-circulating feed and maintaining vacuum. The thermal energy requirement is significant (e.g., up to 2609 MJ/m3 of thermal energy) and is required to maintain the feed stream at 65 °C in recirculation mode. The electrical energy requirement is very small (3 of required at 65 °C feed temperature at steady state) with the vacuum pump contributing to the majority of the electrical energy. The energy required for the pervaporation process was also compared to other desalination processes such as Reverse Osmosis (RO), Multi-stage Flash (MSF), and Multiple Effect Distillation (MED). The electrical energy requirement for pervaporation is the lowest among these desalination technologies. However, the thermal energy needed for pervaporation is significant. Pervaporation may be attractive when the process is integrated with waste heat and heat recovery option and used in niche applications such as RO brine concentration or salt recovery.
- 10 May 2017
- Published by Springer Nature in Polymer Bulletin
- Vol. 75 (2) , 581-595
Effects of a volatile solvent with low surface tension combining with the silica network reinforcement on retention of LLC structure in polymer matrix
- 10 May 2017
- Published by Springer Nature in Polymer Bulletin
- Vol. 75 (2) , 581-595
Effects of a volatile solvent with low surface tension combining with the silica network reinforcement on retention of LLC structure in polymer matrix
- Open Access
- 29 December 2011
- Published by Canadian Center of Science and Education in Journal of Materials Science Research
- Vol. 1 (1) , 37
Effect of Membrane Properties on Performance of Membrane Distillation for Ammonia Removal
Membrane distillation (MD) has received much attention in recent years as an alternative technology for the removal of volatile compounds from industrial waters. The microporous hydrophobic membrane utilised in MD allows only vapour passing through and the process selectivity is essentially determined by the liquid-vapour equilibrium conditions existing at the liquid-membrane interface. In this study, a series of asymmetrically structured polyvinylidene fluoride (PVDF) hollow fibre membranes were fabricated and tested for the removal of ammonia from simulated industrial wastewater. The asymmetric membranes contain very thin skin layer with macrovoids supported underneath. Hollow fibre MD modules with membrane area of 0.06 m 2 have been assembled and tested for dilute aqueous solutions containing ammonia at concentrations 90% ammonia removal could be achieved. The results from the MD experiments were compared and the effect of membranes characteristics was discussed.
- 29 December 2011
- Published by Canadian Center of Science and Education in Journal of Materials Science Research
- Vol. 1 (1) , 37
Open AccessEffect of Membrane Properties on Performance of Membrane Distillation for Ammonia Removal
Membrane distillation (MD) has received much attention in recent years as an alternative technology for the removal of volatile compounds from industrial waters. The microporous hydrophobic membrane utilised in MD allows only vapour passing through and the process selectivity is essentially determined by the liquid-vapour equilibrium conditions existing at the liquid-membrane interface. In this study, a series of asymmetrically structured polyvinylidene fluoride (PVDF) hollow fibre membranes were fabricated and tested for the removal of ammonia from simulated industrial wastewater. The asymmetric membranes contain very thin skin layer with macrovoids supported underneath. Hollow fibre MD modules with membrane area of 0.06 m 2 have been assembled and tested for dilute aqueous solutions containing ammonia at concentrations 90% ammonia removal could be achieved. The results from the MD experiments were compared and the effect of membranes characteristics was discussed.
- 8 December 2011
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 8 (7) , 2087-2094
Structure retention in cross-linked poly(ethylene glycol) diacrylate hydrogel templated from a hexagonal lyotropic liquid crystal by controlling the surface tension
Retaining hexagonal lyotropic liquid crystal (LLC) structures in polymers after surfactant removal and drying is particularly challenging, as the surface tension existing during the drying processes tends to change the morphology. In this study, cross-linked poly(ethylene glycol) diacrylate (PEGDA) hydrogels were prepared in LLC hexagonal phases formed from a dodecyltrimethylammonium bromide (DTAB)/water system. The retention of the hexagonal LLC structures was examined by controlling the surface tension. Polarized light microscopy, X-ray diffraction and small angle X-ray scattering results indicate that the hexagonal LLC structure was successfully formed before polymerization and well retained after polymerization and after surfactant removal when the surface tension forces remained neutral. Controlling the surface tension during the drying process can retain the nanostructures templated from lyotropic liquid crystals which will result in the formation of materials with desired nanostructures.
- 8 December 2011
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 8 (7) , 2087-2094
Structure retention in cross-linked poly(ethylene glycol) diacrylate hydrogel templated from a hexagonal lyotropic liquid crystal by controlling the surface tension
Retaining hexagonal lyotropic liquid crystal (LLC) structures in polymers after surfactant removal and drying is particularly challenging, as the surface tension existing during the drying processes tends to change the morphology. In this study, cross-linked poly(ethylene glycol) diacrylate (PEGDA) hydrogels were prepared in LLC hexagonal phases formed from a dodecyltrimethylammonium bromide (DTAB)/water system. The retention of the hexagonal LLC structures was examined by controlling the surface tension. Polarized light microscopy, X-ray diffraction and small angle X-ray scattering results indicate that the hexagonal LLC structure was successfully formed before polymerization and well retained after polymerization and after surfactant removal when the surface tension forces remained neutral. Controlling the surface tension during the drying process can retain the nanostructures templated from lyotropic liquid crystals which will result in the formation of materials with desired nanostructures.
- 24 June 2010
- Published by Pleiades Publishing Ltd in Kinetics and Catalysis
- Vol. 51 (3) , 398-403
A kinetic study of oxidative dehydrogenation of isobutane to isobutylene over chromium oxide supported on lanthanum carbonate
Kinetics of oxidative dehydrogenation of isobutane to isobutylene over chromium oxide supported on lanthanum carbonate was studied. The formation rate of isobutylene was found to be first order in...
- 24 June 2010
- Published by Pleiades Publishing Ltd in Kinetics and Catalysis
- Vol. 51 (3) , 398-403
A kinetic study of oxidative dehydrogenation of isobutane to isobutylene over chromium oxide supported on lanthanum carbonate
Kinetics of oxidative dehydrogenation of isobutane to isobutylene over chromium oxide supported on lanthanum carbonate was studied. The formation rate of isobutylene was found to be first order in...
- 1 December 2008
- Published by IWA Publishing in Water Practice & Technology
- Vol. 3 (4)
Fouling Development in Full-Scale Reverse Osmosis Process
The fouling of a reverse osmosis membrane after one year of service in a brackish water treatment plant was investigated. It has been found that the extent of fouling was uneven across the membrane surface with regions underneath or near the strands of the feed spacer being more severely affected. This is attributed to the local variations in the hydrodynamic conditions, partly due to the effect of the feed spacer. Microscopic examination of the cross-sections of the fouled membrane revealed that the fouling developed through different stages as suggested by the multi-layered structure of the surface deposits. In particular, the initial fouling stage involved the formation of a surface layer less than about 7 μm thick which consisted of an amorphous matrix comprising organic–Al–P complexes with embedded particulate matter, mostly aluminium silicates. Subsequent fouling involved the deposition of further amorphous material on top of the existing fouling layer. This secondary amorphous material did not seem to contain any particulate matter nor any inorganic elements, and is suggested to include extracellular polymeric substances. As the fouling proceeded further, aluminium silicate crystals started to grow exclusively on top of the secondary amorphous material in the absence of other foulants.
- 1 December 2008
- Published by IWA Publishing in Water Practice & Technology
- Vol. 3 (4)
Fouling Development in Full-Scale Reverse Osmosis Process
The fouling of a reverse osmosis membrane after one year of service in a brackish water treatment plant was investigated. It has been found that the extent of fouling was uneven across the membrane surface with regions underneath or near the strands of the feed spacer being more severely affected. This is attributed to the local variations in the hydrodynamic conditions, partly due to the effect of the feed spacer. Microscopic examination of the cross-sections of the fouled membrane revealed that the fouling developed through different stages as suggested by the multi-layered structure of the surface deposits. In particular, the initial fouling stage involved the formation of a surface layer less than about 7 μm thick which consisted of an amorphous matrix comprising organic–Al–P complexes with embedded particulate matter, mostly aluminium silicates. Subsequent fouling involved the deposition of further amorphous material on top of the existing fouling layer. This secondary amorphous material did not seem to contain any particulate matter nor any inorganic elements, and is suggested to include extracellular polymeric substances. As the fouling proceeded further, aluminium silicate crystals started to grow exclusively on top of the secondary amorphous material in the absence of other foulants.