Vaclav Baca
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Vaclav Baca has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Jiri Marvan
Department of Orthopedics and Traumatology, Third Faculty of Medicine, Charles University, Ruska 87, 10000 Prague, Czech Republic
3 shared publications- Valer Dzupa
Centrum pro integrované studium pánve 3. LF UK, Praha
3 shared publications David Kachlik
Department of Health Care Studies, Colleague of Polytechnics Jihlava, Tolsteho 16, 586 01, Jihlava, Czech Republic
2 shared publications- David Kachlik
Department of Anatomy, Second Faculty of Medicine Charles University Prague Czech Republic
2 shared publications David Kachlík
2 shared publicationsRadek Bartoska
Department of Orthopaedy and Traumatology, Third Faculty of Medicine, Charles University in Prague and University Hospital Kralovske Vinohrady, Prague, Czech Republic
2 shared publications
Latest Publications
- 1 January 2017
- Vol. 19 (1) , 33-39
Fixation of distal fibular fractures: A biomechanical study of plate fixation techniques.
Ankle fractures are complex injuries with variable prognoses that depend upon many factors. The aim of the treatment is to restore the ankle joint biomechanical stability with maximum range of motion. Most ankle fractures are fibular fractures, which have a typical oblique fracture line in the distal fibula located in the area of the tibiofibular syndesmosis. The aim of this study was to simulate numerically several fixation techniques of the distal fibular fractures, evaluate their stability, determine their impact on surrounding tissue load, and correlate the results to clinical treatment experience. The following three models of fibular fracture fixation were used: (a) plate fixation with three screws attached above/below and lag screws, (b) plate fixation with two screws attached above/below and lag screws, and (c) three lag screws only. All three fracture fixation models were analyzed according to their use in both healthy physiological bone and osteoporotic bone tissue. Based on the results of Finite Element Analysis for these simulations, we found that the most appropriate fixation method for Weber-B1 fibular fractures was an unlocked plate fixation using six screws and lag screws, both in patients with physiological and osteoporotic bone tissue. Conversely, the least appropriate fixation method was an unlocked plate fixation with four screws and lag screws. Although this fixation method reduces the stress on patients during surgery, it greatly increased loading on the bone and, thus, the risk of fixation failure. The final fixation model with three lag screws only was found to be appropriate only for very limited indications.
- 1 January 2017
- Vol. 19 (1) , 33-39
Fixation of distal fibular fractures: A biomechanical study of plate fixation techniques.
Ankle fractures are complex injuries with variable prognoses that depend upon many factors. The aim of the treatment is to restore the ankle joint biomechanical stability with maximum range of motion. Most ankle fractures are fibular fractures, which have a typical oblique fracture line in the distal fibula located in the area of the tibiofibular syndesmosis. The aim of this study was to simulate numerically several fixation techniques of the distal fibular fractures, evaluate their stability, determine their impact on surrounding tissue load, and correlate the results to clinical treatment experience. The following three models of fibular fracture fixation were used: (a) plate fixation with three screws attached above/below and lag screws, (b) plate fixation with two screws attached above/below and lag screws, and (c) three lag screws only. All three fracture fixation models were analyzed according to their use in both healthy physiological bone and osteoporotic bone tissue. Based on the results of Finite Element Analysis for these simulations, we found that the most appropriate fixation method for Weber-B1 fibular fractures was an unlocked plate fixation using six screws and lag screws, both in patients with physiological and osteoporotic bone tissue. Conversely, the least appropriate fixation method was an unlocked plate fixation with four screws and lag screws. Although this fixation method reduces the stress on patients during surgery, it greatly increased loading on the bone and, thus, the risk of fixation failure. The final fixation model with three lag screws only was found to be appropriate only for very limited indications.
- 8 December 2015
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 38 (5) , 577-585
The importance of intramedullary hip nail positioning during implantation for stable pertrochanteric fractures: biomechanical analysis
Purpose Proximal femoral fractures are among the most commonly sustained fractures. The current treatment of stable proximal femoral fractures located in trochanteric region primarily involves the use of two systems: extramedullary dynamic hip screws and intramedullary hip nails. Given that these fractures are mainly found in the elderly population, the necessity of a repeat, due to failure of the first, may jeopardize the patient’s life. Decisive factors contributing to the healing of a fracture (or the failure thereof) include fracture pattern, technical implementation of the operation (i.e., position of the implant), implant’s properties and its changes in relation to the surrounding bone tissue during loading. Each screw insertion variant results in damage to various load-bearing bone structures, which can be expected to influence healing quality and stability of newly formed bone. Method With the aid of a numerical model and finite element methods, the authors analyzed several different positions of IMHN/PFH-nails in the proximal femur, with the objective of determining positions with an increased risk of failure. Results and conclusion In model situations, it has been shown that in stable fractures results do not depend on absolutely precise positioning and small deflections in the nails and neck screws positions do not significantly increase the risk of failure for the entire fixation. Damage to load-bearing structures relative to various implant placements does not impact the resultant overall fixation stability. Therefore, it is not necessary to re-introduce implants in the ideal position, which can lead to reduced patient radiation doses during surgery.
- 8 December 2015
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 38 (5) , 577-585
The importance of intramedullary hip nail positioning during implantation for stable pertrochanteric fractures: biomechanical analysis
Purpose Proximal femoral fractures are among the most commonly sustained fractures. The current treatment of stable proximal femoral fractures located in trochanteric region primarily involves the use of two systems: extramedullary dynamic hip screws and intramedullary hip nails. Given that these fractures are mainly found in the elderly population, the necessity of a repeat, due to failure of the first, may jeopardize the patient’s life. Decisive factors contributing to the healing of a fracture (or the failure thereof) include fracture pattern, technical implementation of the operation (i.e., position of the implant), implant’s properties and its changes in relation to the surrounding bone tissue during loading. Each screw insertion variant results in damage to various load-bearing bone structures, which can be expected to influence healing quality and stability of newly formed bone. Method With the aid of a numerical model and finite element methods, the authors analyzed several different positions of IMHN/PFH-nails in the proximal femur, with the objective of determining positions with an increased risk of failure. Results and conclusion In model situations, it has been shown that in stable fractures results do not depend on absolutely precise positioning and small deflections in the nails and neck screws positions do not significantly increase the risk of failure for the entire fixation. Damage to load-bearing structures relative to various implant placements does not impact the resultant overall fixation stability. Therefore, it is not necessary to re-introduce implants in the ideal position, which can lead to reduced patient radiation doses during surgery.
- 1 September 2015
- Published by Elsevier in Annals of Anatomy - Anatomischer Anzeiger
- Vol. 201, 8-16
Terminologia Anatomica after 17 years: Inconsistencies, mistakes and new proposals
- 1 September 2015
- Published by Elsevier in Annals of Anatomy - Anatomischer Anzeiger
- Vol. 201, 8-16
Terminologia Anatomica after 17 years: Inconsistencies, mistakes and new proposals
- 30 April 2013
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 35 (10) , 957-962
The correlation between muscles insertions and topography of break lines in pertrochanteric fractures: a comprehensive anatomical approach of complex proximal femur injuries
Purpose The purpose of our work was to verify the hypothesis that muscle insertions and ligament attachments have an impact on the course of typical break lines in the area of the trochanteric massif, i.e., to provide a more detailed description of the origins and insertions of the musculo-ligamentous apparatus on the surface of the proximal femur, and to find a potential morphological correlate between muscle insertions and ligament attachments to the proximal femur and the course of the break line in a typical pertrochanteric fracture. Methods A detailed dissection of areas of trochanter major et minor, linea et crista intertrochanterica was performed in 50 anatomical preparations of the proximal femur, and the insertions of the muscular-ligamentous structures were described. The set of 600 radiographs were used to obtain projections of typical break lines on the proximal femur, and corresponding areas of exposed bone surface were identified in the anatomical preparations based on the projections and on 15 real specimens of patients after the pertrochanteric fracture osteosynthesis. Results and conclusion Bone covered only with the periosteum, with no reinforcing elements of the origin or insertions of muscles or attachments of ligaments, represents the locus minoris resistentiae for beginning of fractures. Variability in the sizes and shapes of pertrochanteric fracture fragments also depends on variability of the locations and sizes of soft tissue attachment areas at specified sites on the proximal femur.
- 30 April 2013
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 35 (10) , 957-962
The correlation between muscles insertions and topography of break lines in pertrochanteric fractures: a comprehensive anatomical approach of complex proximal femur injuries
Purpose The purpose of our work was to verify the hypothesis that muscle insertions and ligament attachments have an impact on the course of typical break lines in the area of the trochanteric massif, i.e., to provide a more detailed description of the origins and insertions of the musculo-ligamentous apparatus on the surface of the proximal femur, and to find a potential morphological correlate between muscle insertions and ligament attachments to the proximal femur and the course of the break line in a typical pertrochanteric fracture. Methods A detailed dissection of areas of trochanter major et minor, linea et crista intertrochanterica was performed in 50 anatomical preparations of the proximal femur, and the insertions of the muscular-ligamentous structures were described. The set of 600 radiographs were used to obtain projections of typical break lines on the proximal femur, and corresponding areas of exposed bone surface were identified in the anatomical preparations based on the projections and on 15 real specimens of patients after the pertrochanteric fracture osteosynthesis. Results and conclusion Bone covered only with the periosteum, with no reinforcing elements of the origin or insertions of muscles or attachments of ligaments, represents the locus minoris resistentiae for beginning of fractures. Variability in the sizes and shapes of pertrochanteric fracture fragments also depends on variability of the locations and sizes of soft tissue attachment areas at specified sites on the proximal femur.
- 15 March 2007
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 29 (3) , 201-207
The course of osteons in the compact bone of the human proximal femur with clinical and biomechanical significance
The aim of the study was to analyze the structure and course of osteons in the compact bone of individual regions of the upper end of the femur and to consider the possible association with the course of typical peritrochanteric fracture lines. The issue of the architecture of this region has been dealt with by a number of authors since the first half of the nineteenth century, but until the present structural analysis it has been examined only by a few authors. We analyzed the structure of bones on specimens prepared by the method of repeated grinding, impregnating and polishing of the bone surface. We grounded and subsequently evaluated the bone in 20 dry specimens of the proximal femur, where the courses of the central vascular canals were described in the region of the femoral neck, the lesser trochanter, the greater trochanter, the intertrochanteric crest and line. The osteons were incorporated into a biomechanical model of the proximal femur and compared with the FEM model and correlation with the distribution of surface stresses was described. Certain areas were identified in the region of the trochanters where the course of osteons coincided with the course of the typical fracture lines of peritrochanteric fractures with typical fragments.
- 15 March 2007
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 29 (3) , 201-207
The course of osteons in the compact bone of the human proximal femur with clinical and biomechanical significance
The aim of the study was to analyze the structure and course of osteons in the compact bone of individual regions of the upper end of the femur and to consider the possible association with the course of typical peritrochanteric fracture lines. The issue of the architecture of this region has been dealt with by a number of authors since the first half of the nineteenth century, but until the present structural analysis it has been examined only by a few authors. We analyzed the structure of bones on specimens prepared by the method of repeated grinding, impregnating and polishing of the bone surface. We grounded and subsequently evaluated the bone in 20 dry specimens of the proximal femur, where the courses of the central vascular canals were described in the region of the femoral neck, the lesser trochanter, the greater trochanter, the intertrochanteric crest and line. The osteons were incorporated into a biomechanical model of the proximal femur and compared with the FEM model and correlation with the distribution of surface stresses was described. Certain areas were identified in the region of the trochanters where the course of osteons coincided with the course of the typical fracture lines of peritrochanteric fractures with typical fragments.