TSTsutomu Sugimoto

Tsutomu Sugimoto

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tsutomu Sugimoto has a total of 43 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Case of Giant Unruptured Left Coronary Sinus of Valsalva Aneurysm

    by Fuyuki Asami, Kazuo Yamamoto, Tsutomu Sugimoto, Yuuki Okamoto, Mitsuhiro Kimura, Ayako Nagasawa, Satoru Shiraiwa, Shinpei Yoshii

    • 1 November 2015
      • Vol. 68  (11) , 888-93

    [Early and Late Outcomes of Valve Surgery in Active Infective Endocarditis Patients with Cerebral Complications].

    by Yuki Okamoto, Kazuo Yamamoto, Tsutomu Sugimoto, Fuyuki Asami, Mitsuhiro Kimura, Ayako Nagasawa, Satoru Shiraiwa, Shinpei Yoshii

    We carried out a retrospective evaluation of the early and late outcomes of valve surgery for acute endocarditis patients with cerebrovascular disease. Between January 2002 and August 2014, a total of 17 patients (early group, n=10;delayed group, n=7) underwent valve surgery with or without an additional procedure. Craniotomy was performed in 1 patient in the early group and 2 patients in the delayed group before valve surgery. There was 1 in-hospital death due to acute respiratory distress syndrome in the early group and 1 death due to intestinal bleeding in the delayed group. Postoperative deterioration was observed in 1 in the delayed group. Overall survival in the early group was 90% and was not significantly different from survival in the delayed group (86%). In conclusion, our study demonstrated good early and mid-term outcomes for valve surgery in active endocarditis patients with cerebrovascular disease. There was no postoperative deterioration in the early group. Thus, an early operation for these patients may be acceptable.

    • 1 September 2013
      • Vol. 66  (10) , 861-9

    [Early and mid-term outcomes of aortic valve replacement for aortic stenosis in hemodialysis patients].

    by Yuki Okamoto, Kazuo Yamamoto, Tsutomu Sugimoto, Takashi Wakabayashi, Kaori Kato, Sinya Mimura, Shinpei Yoshii

    We carried out a retrospective evaluation of the early and mid-term outcomes of aortic valve replacement (AVR) for aortic stenosis in hemodialysis patients. Between 2004 and 2012, a total of 40 dialysis patients underwent AVR with or without an additional procedure. Hemodialysis was performed routinely the day before and during the operation. At surgery, decalcification was performed using a cavitron ultrasonic surgical aspirator(CUSA) and a high performance mechanical valve was then implanted, with the exception of elderly patients or those in whom use of oral anticoagulation is contraindicated. A mechanical valve was used in 33 patients and a bioprosthetic valve in 7 patients. Hemodialysis was resumed on the 2nd postoperative day in the majority of patients. There was no intra-operative death and in-hospital mortality was 5%, due to sepsis and intestinal ischemia in 2 of the 40 patients. The mean follow-up period was 33 months. There was no structural valve deterioration in patients with the bioprosthetic valve. Of the 8 late deaths, the reason for deaths was cardiac in 4 patients. Overall survival in the 40 patients was 92%, 79%, and 54% at 1, 3, and 5 years, respectively. Our study demonstrated good early and mid-term outcomes for aortic valve replacement in hemodialysis patients. CUSA was useful for patients with a calcified valve and annulus. A bioprosthetic valve was acceptable for use in elderly patients.


    • 1 May 2013
      • Vol. 66  (5) , 360-5

    [Simplified aortic root replacement in the era of complex operation].

    by Tsutomu Sugimoto, Kazuo Yamamoto, Yuki Okamoto, Takashi Wakabayashi, Kaori Kato, Shinya Mimura, Shinpei Yoshii

    The purpose of the present study is to assess the clinical results of aortic root replacement using the Carbo-Seal composite graft( CS) compared with the other type of homemade composite grafts. Fifty-nine patients who underwent aortic root replacement between January 1998 to December 2010 were retrospectively analyzed. Twenty-six received homemade composite graft( group 1;1998 ~ 2005) and 33 received CS( group 2;2005 ~ 2010). The duration of operation was longer in group 1:469.2±143.5 min versus 380.3±153.9 min (p=0.03). Although there was no statistically significant difference, group 2 had a higher complex operation rate compared with group1(23.1% versus 45.5%, p=0.07). Overall hospital mortality was 11.5% in group1 versus 3.0% in group2. Prevalence of major complication was significantly lower in group 2 (46.2% versus 18.2%, p=0.02).Requirement of intraoperative blood transfusion (group 1;1,130.8±854.7 ml versus group 2;598.2±836.4 ml) and amount of blood loss in the 1st 12 hours post operation (group 1;628.3±474.6 ml versus group 2;447.8±253.2 ml) were significantly lower in group 2. By univariate analysis, duration of operation, duration of cardio-pulmonary bypass (CPB), blood transfusion, acute dissection were independent risk factors and CS use was negative risk factor for major events. Aortic root replacement with use of CS can be performed with a relatively low early mortality and morbidity. Because a complicated operation is increasing in recent years, use of CS graft may simplify a Bentall operation.

    • 1 January 2012
      • Vol. 65  (1) , 81-5

    [Single-stage procedure for multiple dissected aortic aneurysms with coagulopathy in an elderly patient].

    by Hiroki Satoh, Kazuo Yamamoto, Satoshi Takahashi, Takashi Wakabayashi, Koki Takizawa, Tsutomu Sugimoto, Sinpei Yoshii, Kazuhiko Hanzawa

    An 86-year-old man was admitted for abdominal pain. Dissected descending thoracic aortic aneurysm and infrarenal abdominal aortic aneurysm were observed under computed tomographic (CT) scan. Hematologic studies revealed low platelet count and an increase in fibrin degradation products (FDP), and disseminated intravascular coagulation( DIC) associated with dissecting aortic aneurysm was highly suspected. Platelet transfusion was performed and gabexate mesilate was administered, however, no improvement of DIC could be obtained. An increase in aortic diameter was observed under CT scan and surgery was performed. The infrarenal aneurysm was replaced with a bifurcated prosthetic graft under open repair. Simultaneously, an endovascular stent-graft was delivered from the left limb of the abdominal graft and implanted into the descending thoracic aorta. The postoperative recovery was uneventful but platelet count did not improve in this case.

  • Open Access

    A Modified Infarct Exclusion Repair of Posterior Postinfarction Ventricular Perforation: Triple-patch Technique for Postinfarction Ventricular Septal Perforation in 2 Female Patients

    by Tsutomu Sugimoto, Shinpei Yoshii, Kazuo Yamamoto, Kouki Takizawa, Akifumi Uehara, Masahiro Satoh, Sigetaka Kasuya

    We describe a new technique for the early surgical repair of a posterior postinfarction ventricular septal perforation (VSP) in two consecutive female patients. The occurrence of a posterior VSP is rare, and its repair is technically difficult because the posteromedial papillary muscle is located adjacent to the intraventricular septum. This modification appears to prevent leaks to the right ventricle through the VPS with a single direct patch and the use of two equine pericardial patches to form a single endocardial pouch. The women were 77 and 62 years old, and the time between the onset of acute MI and surgery was 3 and 6 days. On preoperative catheterization, Qp/Qs was 4.18 and 4.01. Neither operative death nor residual shunting was observed.


    • 1 August 2010
      • Vol. 16  (1) , 57-9

    Severe aortic regurgitation resulting from a downward displacement of anterior aortic annulus and fibrous strands in the bicuspid aortic valve.

    by Takehito Mishima, Kazuo Yamamoto, Tsutomu Sugimoto, Kenji Sakakibara, Akifumi Uehara, Shinpei Yoshii

    Aortic regurgitation is occasionally caused by fibrous strands and more rarely by downward displacement of the aortic annulus. The present report describes an 18-year-old man with aortic regurgitation resulting from an anterior-posterior type of bicuspid aortic valve with fibrous strands and downward displacement of the anterior aortic annulus. A pair of fibrous strands at the anterior cusp of the bicuspid valve lifted the free margin of the cusp, and the anterior cusp originated from the intraventricular septum. We considered that the aortic regurgitation was due to poor coaptation of the cusps because of these two conditions. After resection of the cusps and the strands, the aortic valve was replaced at the intra-annular position.


    • 1 July 2010
      • Vol. 63  (7) , 531-5

    [Assessment of pulse wave velocity as a marker of post-operative cardiovascular risk in off-pump coronary artery bypass grafting patients].

    by Tsutomu Sugimoto, Kazuo Yamamoto, Koki Takizawa, Akifumi Uehara, Masahiro Sato, Hiroki Sato, Shinpei Yoshii, Shigetaka Kasuya

    Pulse wave velocity is widely used as an index of arterial stiffness. The aim of this study is to assess the usefulness of pulse wave velocity as a risk factor in patients who underwent off-pump coronary artery bypass grafting (CABG) [OPCAB]. Arterial stiffness was measured by brachial-ankle pulse wave velocity (baPWV) and the ratio of patient's baPWV to age-matched normal value was calculated in 90 OPCAB patients. The mean age and male/female ratio were 69.1 years old and 68/22, respectively. baPWV was higher in CABG patients (1,891 +/- 511 cm/s) than that in age-matched normal value (p<0.01). Preoperatively, baPWV ratio did not correlate to the severity of coronary artery diseases. There were 1 (1.1%) in-hospital death and 48 incidences of postoperative complication in 38 patients. The baPWV ratio in the group with postoperative major complications except atrial fibrillation tended to be higher than that in the non-complication group (1.38 +/- 0.36 vs 1.26 +/- 0.30, p = 0.09). The elevated baPWV may be a useful predictor of operative risk in patients who undergo CABG.


  • Vacuum-Assisted Closure Technique to Avoid Abdominal Compartment Syndrome and Infection: A Successful Treatment of an Infected Abdominal Aortic and Left Common Iliac Aneurysms Complicated by MSSA Psoas Abscess

    by Akifumi Uehara, Masahiro Sato, Hiroki Sato, Koki Takizawa, Tsutomu Sugimoto, Kazuo Yamamoto, Shinpei Yoshii, Shigetaka Kasuya

    症例は68歳,女性.腰部から左側腹部,左鼠径部にかけての激痛および高熱を主訴に前医を受診した.CTで左腸腰筋膿瘍と腹部大動脈終末部周囲の低濃度領域を認めた.炎症所見高値で血液培養でMSSAが検出され,抗菌薬加療を行うが,経過中腹部大動脈終末部に仮性瘤を認めたため,当院に搬送となった.MSSA腸腰筋膿瘍を契機とする感染性腹部大動脈瘤+左総腸骨動脈瘤と診断し,右腋窩-両側大腿動脈バイパス後,腹部大動脈,両側総腸骨動脈の離断・結紮,および左腸腰筋膿瘍腔内大網充填術を行った.腸管および腸間膜浮腫が著明で閉腹不可能であったためvacuum assisted closure(VAC)療法とし,42日後6回目の手術で閉腹できた.経過中腹腔内感染は生じなかった.腸腰筋膿瘍に伴う感染性動脈瘤は非常に稀であり,また致死率の高い疾患である.VAC療法はabdominal compartment syndrome(ACS)回避だけでなく腹腔内感染回避にも有効である.


    • 1 May 2009
      • Vol. 62  (5) , 373-5

    [Exposure for harvesting gastroepiploic artery graft].

    by Tsutomu Sugimoto, K Yamamoto, K Takizawa, A Uehara, T Mishima, M Sato, S Yoshii, S Kasuya

    We present out technique for harvesting the gastroepiploic artery (GEA). We use a Universal Stabilizer Arm and an assistant attachment to push the liver against the diaphragm, giving en enough working space to harvest the graft. Between January and December 2007, 99 isolated coronary artery bypass grafting (CABG)s were performed, and in 36 (36.4%) patients the GEA was harvested using this technique. The mean operation time was 251.1 +/- 40.5 minutes and the mean number of distal anastomosis was 3.6 +/- 0.8. The early patency rate of the GEA graft was 95%. Combined use of a Universal Stabilizer Arm and an assistant attachment provide good exposure for harvesting the GEA.