Pat Sandra
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Pat Sandra has a total of 98 co-authors. Here are the top co-authors by number of shared publications:
- Frédéric Lynen
Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, Ghent B-9000, Belgium
13 shared publications Frank David
Research Institute for Chromatography, Kennedypark 26, 8500 Kortrijk, Belgium
10 shared publicationsGerd Vanhoenacker
Research Institute for Chromatography, Kennedypark 26, B-8500 Kortrijk, Belgium
7 shared publications- André de Villiers
Department of Chemistry and Polymer Science, Stellenbosch University, Private Bag X1, Matieland 7602, South Africa
6 shared publications Bart Tienpont
Research Institute for Chromatography, Kortrijk, Belgium. Fax: +32-56-204859
5 shared publicationsF. David
Research Institute for Chromatography
4 shared publications
Latest Publications
- 26 April 2024
- Published by Elsevier in Journal of Chromatography A
- Vol. 1726, 464947
Multidimensional LC-MS with 1D multi-method option and parallel middle-up and bottom-up MS acquisition for in-depth characterization of antibodies
- 26 April 2024
- Published by Elsevier in Journal of Chromatography A
- Vol. 1726, 464947
Multidimensional LC-MS with 1D multi-method option and parallel middle-up and bottom-up MS acquisition for in-depth characterization of antibodies
- 19 February 2024
- Published by Elsevier in Journal of Chromatography A
- Vol. 1719, 464756
Evaluation of size-exclusion chromatography, multi-angle light scattering detection and mass photometry for the characterization of mRNA
- 19 February 2024
- Published by Elsevier in Journal of Chromatography A
- Vol. 1719, 464756
Evaluation of size-exclusion chromatography, multi-angle light scattering detection and mass photometry for the characterization of mRNA
- 7 September 2016
- Published by Springer Nature
- p. 1-16
Reversed-Phase Liquid Chromatography Mass Spectrometry (RP-LC-MS) in Lipidomics
- 7 September 2016
- Published by Springer Nature
- p. 1-16
Reversed-Phase Liquid Chromatography Mass Spectrometry (RP-LC-MS) in Lipidomics
- Open Access
- 1 September 2014
- Published by Elsevier in Journal of Chromatography A
- Vol. 1358, 240-251
Multidimensional gas chromatography in combination with accurate mass, tandem mass spectrometry, and element-specific detection for identification of sulfur compounds in tobacco smoke
- 1 September 2014
- Published by Elsevier in Journal of Chromatography A
- Vol. 1358, 240-251
Open AccessMultidimensional gas chromatography in combination with accurate mass, tandem mass spectrometry, and element-specific detection for identification of sulfur compounds in tobacco smoke
- 27 August 2013
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 406 (2) , 401-407
Solid-phase extraction based on hydrophilic interaction liquid chromatography with acetone as eluent for eliminating matrix effects in the analysis of biological fluids by LC-MS
Analysis of drugs and metabolites in biological matrices such as blood or plasma by LC-MS is routinely challenged by the presence of large quantities of competing molecules for ionization in soft ionization sources, such as proteins and phospholipids. While the former can easily be removed by protein precipitation, pre-analytical extraction of the latter is necessary because they show very high retention in reversed-phase LC resulting in long analysis times or in ion suppression effects when not eluted before the next runs. A novel HILIC-based SPE approach, making use of silica cartridges and of acetone as organic solvent, is introduced as a potent alternative to current commercial methods for phospholipid removal. The methodology was developed and tested for a broad polarity range of pharmaceutical solutes (log P from 0 to 6.6) and broad applicability can therefore be envisaged.
- 27 August 2013
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 406 (2) , 401-407
Solid-phase extraction based on hydrophilic interaction liquid chromatography with acetone as eluent for eliminating matrix effects in the analysis of biological fluids by LC-MS
Analysis of drugs and metabolites in biological matrices such as blood or plasma by LC-MS is routinely challenged by the presence of large quantities of competing molecules for ionization in soft ionization sources, such as proteins and phospholipids. While the former can easily be removed by protein precipitation, pre-analytical extraction of the latter is necessary because they show very high retention in reversed-phase LC resulting in long analysis times or in ion suppression effects when not eluted before the next runs. A novel HILIC-based SPE approach, making use of silica cartridges and of acetone as organic solvent, is introduced as a potent alternative to current commercial methods for phospholipid removal. The methodology was developed and tested for a broad polarity range of pharmaceutical solutes (log P from 0 to 6.6) and broad applicability can therefore be envisaged.
- 19 May 2010
- Published by Wiley in Journal of Separation Science
- Vol. 33 (10) , 1504-1512
Considerations on comprehensive and off‐line supercritical fluid chromatography×reversed‐phase liquid chromatography for the analysis of triacylglycerols in fish oil
The separation of the triacylglycerols in fish oil was performed by comprehensive and off‐line supercritical fluid chromatography combined with RP‐LC. The first dimension consisted of two serially coupled silver‐ion (SI)‐loaded columns operated with a supercritical mobile phase (supercritical fluid chromatography, SFC) in both the cases, whereas the second dimension was performed in non‐aqueous RP mode (NARP‐LC) on a 10‐cm monolithic octadecyl silica (ODS) or a 45‐cm long ODS column packed with 1.8 μm particles for the comprehensive and off‐line separations, respectively. Despite the outstanding performance of the SI‐SFC×NARP‐LC interface, the high complexity of the sample rendered the online separation far from complete. The off‐line approach gave much better separation mainly because of the higher peak capacity of the second‐dimension column, but even in this case, the use of MS was mandatory to elucidate the different triacylglycerols in fish oil. The disadvantage of the off‐line procedure was the long analysis time.
- 19 May 2010
- Published by Wiley in Journal of Separation Science
- Vol. 33 (10) , 1504-1512
Considerations on comprehensive and off‐line supercritical fluid chromatography×reversed‐phase liquid chromatography for the analysis of triacylglycerols in fish oil
The separation of the triacylglycerols in fish oil was performed by comprehensive and off‐line supercritical fluid chromatography combined with RP‐LC. The first dimension consisted of two serially coupled silver‐ion (SI)‐loaded columns operated with a supercritical mobile phase (supercritical fluid chromatography, SFC) in both the cases, whereas the second dimension was performed in non‐aqueous RP mode (NARP‐LC) on a 10‐cm monolithic octadecyl silica (ODS) or a 45‐cm long ODS column packed with 1.8 μm particles for the comprehensive and off‐line separations, respectively. Despite the outstanding performance of the SI‐SFC×NARP‐LC interface, the high complexity of the sample rendered the online separation far from complete. The off‐line approach gave much better separation mainly because of the higher peak capacity of the second‐dimension column, but even in this case, the use of MS was mandatory to elucidate the different triacylglycerols in fish oil. The disadvantage of the off‐line procedure was the long analysis time.
- 7 May 2010
- Published by Elsevier in Journal of Chromatography A
- Vol. 1217 (19) , 3217-3222
Evaluation of a new polymeric stationary phase with reversed-phase properties for high temperature liquid chromatography
- 7 May 2010
- Published by Elsevier in Journal of Chromatography A
- Vol. 1217 (19) , 3217-3222
Evaluation of a new polymeric stationary phase with reversed-phase properties for high temperature liquid chromatography
- 1 March 2010
- Published by Wiley in Journal of Separation Science
- Vol. 33 (6-7) , 834-837
Green hydrophilic interaction chromatography using ethanol–water–carbon dioxide mixtures
In hydrophilic interaction chromatography (HILIC), best results are obtained with high concentrations of acetonitrile. In the framework of green chromatography, different concentrations of carbon dioxide were added to the mobile phases acetonitrile–water and ethanol–water and the impact on retention and separation in HILIC using bare silica as stationary phase was explored. The features of HILIC using enhanced‐fluidity mobile phases are illustrated with the analysis of the nucleobases and a mixture containing the nucleobases and cortisol, flurbiprofen, theophylline and caffeine. For both organic constituents, the elution window is widened in function of the carbon dioxide concentration and selectivity changes. At high concentrations of carbon dioxide in ethanol, separations were similar to those obtained with acetonitrile without carbon dioxide addition.
- 1 March 2010
- Published by Wiley in Journal of Separation Science
- Vol. 33 (6-7) , 834-837
Green hydrophilic interaction chromatography using ethanol–water–carbon dioxide mixtures
In hydrophilic interaction chromatography (HILIC), best results are obtained with high concentrations of acetonitrile. In the framework of green chromatography, different concentrations of carbon dioxide were added to the mobile phases acetonitrile–water and ethanol–water and the impact on retention and separation in HILIC using bare silica as stationary phase was explored. The features of HILIC using enhanced‐fluidity mobile phases are illustrated with the analysis of the nucleobases and a mixture containing the nucleobases and cortisol, flurbiprofen, theophylline and caffeine. For both organic constituents, the elution window is widened in function of the carbon dioxide concentration and selectivity changes. At high concentrations of carbon dioxide in ethanol, separations were similar to those obtained with acetonitrile without carbon dioxide addition.
- 16 November 2009
- Published by Springer Nature in Chromatographia
- Vol. 71 (1-2) , 1-6
Thermoresponsive Poly(N-vinylcaprolactam) as Stationary Phase for Aqueous and Green Liquid Chromatography
- 16 November 2009
- Published by Springer Nature in Chromatographia
- Vol. 71 (1-2) , 1-6
Thermoresponsive Poly(N-vinylcaprolactam) as Stationary Phase for Aqueous and Green Liquid Chromatography