David Mitton
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
David Mitton has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
W. Skalli
Arts et Metiers ParisTech, LBM , 151 bd de l'hopital, 75013 , Paris , France
6 shared publications- A. Baudoin
Laboratoire de Biomécanique (UMR CNRS 8005), ENSAM-CNRS, 151, Boulevard de l'hôpital, 75013, Paris, France
3 shared publications - Jacques A. de Guise
École de Technologie Supérieure (Canada)
2 shared publications - Sébastien Laporte
Arts et Métiers Institute of Technology EPF Engineering School IBHGC- Institut de Biomécanique Université Sorbonne Paris Nord Humaine Georges Charpak F-75013 Paris France
2 shared publications Wafa Skalli
Laboratoire de Biomécanique, ENSAM-CNRS UMR 8005, 75013 Paris, France
2 shared publicationsA. Badina
Service d'Orthopédie Pédiatrique, Faculté de Médecine, Hôpital Necker, Université Paris Descartes , 149 rue de Sèvre, 75015 , Paris , France
1 shared publication
Latest Publications
- 26 September 2012
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 15 (sup1) , 277-278
Geometric variability of ribs, costal cartilages and sternums from childhood to teenage
- 26 September 2012
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 15 (sup1) , 277-278
Geometric variability of ribs, costal cartilages and sternums from childhood to teenage
- 24 August 2011
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 14 (sup1) , 257-259
First application of an axial speed of sound measurement technique in the monitoring of tendon healing
- 24 August 2011
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 14 (sup1) , 257-259
First application of an axial speed of sound measurement technique in the monitoring of tendon healing
- 31 December 2008
- Published by Elsevier in Journal of Biomechanics
- Vol. 41 (3) , 706-710
3D reconstruction of the ribs from lateral and frontal X-rays in comparison to 3D CT-scan reconstruction
- 31 December 2008
- Published by Elsevier in Journal of Biomechanics
- Vol. 41 (3) , 706-710
3D reconstruction of the ribs from lateral and frontal X-rays in comparison to 3D CT-scan reconstruction
- 10 June 2008
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 46 (8) , 799-805
Parametric subject-specific model for in vivo 3D reconstruction using bi-planar X-rays: application to the upper femoral extremity
Although feasibility of accurate 3D reconstruction of the proximal epiphysis of the femur from biplanar X-rays (frontal and lateral) has been assessed, in vivo application is limited due to bone superposition. The aim of this study was to propose a specific algorithm to get accurate and reproducible, low dose in vivo 3D reconstruction. To achieve this goal, a parametric subject-specific model was introduced as a priori knowledge. This geometric model was based on a database based on proximal epiphysis of 60 femurs. The accuracy was estimated using comparisons to CT scans on 13 cadaveric femurs, then in vivo intra- and inter- observer reproducibility was assessed using a set of 23 femurs. The mean for the relative difference was 0.2 mm for the in vitro 3D accuracy. The mean error was 1.0 mm with maximum value of 5.1 mm in ideal conditions (in vitro). The confidence interval for the inter-observer reproducibility was within +/-2.2 mm. This method gave us a reproducible tool in order to get in vivo 3D reconstructions of the femur proximal epiphysis from biplanar X-rays.
- 10 June 2008
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 46 (8) , 799-805
Parametric subject-specific model for in vivo 3D reconstruction using bi-planar X-rays: application to the upper femoral extremity
Although feasibility of accurate 3D reconstruction of the proximal epiphysis of the femur from biplanar X-rays (frontal and lateral) has been assessed, in vivo application is limited due to bone superposition. The aim of this study was to propose a specific algorithm to get accurate and reproducible, low dose in vivo 3D reconstruction. To achieve this goal, a parametric subject-specific model was introduced as a priori knowledge. This geometric model was based on a database based on proximal epiphysis of 60 femurs. The accuracy was estimated using comparisons to CT scans on 13 cadaveric femurs, then in vivo intra- and inter- observer reproducibility was assessed using a set of 23 femurs. The mean for the relative difference was 0.2 mm for the in vitro 3D accuracy. The mean error was 1.0 mm with maximum value of 5.1 mm in ideal conditions (in vitro). The confidence interval for the inter-observer reproducibility was within +/-2.2 mm. This method gave us a reproducible tool in order to get in vivo 3D reconstructions of the femur proximal epiphysis from biplanar X-rays.
- 5 June 2008
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 11 (3) , 257-262
3D Evaluation of the acetabular coverage assessed by biplanar X-rays or single anteroposterior X-ray compared with CT-scan
Considering the increasing development of three dimensional (3D) imaging, the 3D assessment of the acetabular coverage is to become the most interesting tool for the detection of acetabular pathologies. Biplanar X-rays based methods allow a 3D reconstruction of the hip with a reduced radiation dose. This study proposes a 3D assessment method of the acetabular coverage from biplanar X-rays or from an anteroposterior X-ray (conventional clinical imaging). An in vitro evaluation of the method was performed on six hip joints in comparison with computed tomography. The global coverage, the local coverage and the acetabular rim orientation were estimated in 3D. The mean global acetabular coverage was 40% with an estimated mean accuracy of 1.3% for the biplanar X-rays based method. This study evaluated a 3D assessment method of the acetabular coverage from biplanar X-rays or anteroposterior X-ray and open the way for clinical in vivo applications.
- 5 June 2008
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 11 (3) , 257-262
3D Evaluation of the acetabular coverage assessed by biplanar X-rays or single anteroposterior X-ray compared with CT-scan
Considering the increasing development of three dimensional (3D) imaging, the 3D assessment of the acetabular coverage is to become the most interesting tool for the detection of acetabular pathologies. Biplanar X-rays based methods allow a 3D reconstruction of the hip with a reduced radiation dose. This study proposes a 3D assessment method of the acetabular coverage from biplanar X-rays or from an anteroposterior X-ray (conventional clinical imaging). An in vitro evaluation of the method was performed on six hip joints in comparison with computed tomography. The global coverage, the local coverage and the acetabular rim orientation were estimated in 3D. The mean global acetabular coverage was 40% with an estimated mean accuracy of 1.3% for the biplanar X-rays based method. This study evaluated a 3D assessment method of the acetabular coverage from biplanar X-rays or anteroposterior X-ray and open the way for clinical in vivo applications.
- 1 May 2008
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 123 (5_Suppleme) , 3633
Monitoring of trabecular bone induced microdamage using a nonlinear wave-coupling technique
Bone tissue contains microcracks which may affect its mechanical properties as well as the whole trabecular structure. The relationship between crack density and bone strength is nevertheless poorly understood. Efficient nonlinear (NL) ultrasound methods have been widely developed for nondestructive testing and geophysical applications to detect microdamage. Moreover it has been reported that elastic nonlinearities increase with induced damage. We propose to monitor trabecular bone microdamage using a NL wave coupling technique. Ultrasonic short bursts times of flight (TOF) are modulated as result of NL interaction with a low-frequency (LF) wave in the medium. TOF modulation (TOFM), or propagation velocity variations, are directly related to NL elasticity variations. This technique allows measuring the instantaneous TOFM as a function of the LF pressure. It is thus possible to analyze separately elasticity variations in tension and in compression, and to distinguish the tension to compression phase from the compression to tension phase (hysteresis). In several trabecular bone samples, different TOFM amplitudes in tension and in compression are observed, probably due to microdamage. For increasing damage levels progressively induced by quasi-static compression testing, linear and nonlinear ultrasound parameters are compared to biomechanical parameters.
- 1 May 2008
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 123 (5_Suppleme) , 3633
Monitoring of trabecular bone induced microdamage using a nonlinear wave-coupling technique
Bone tissue contains microcracks which may affect its mechanical properties as well as the whole trabecular structure. The relationship between crack density and bone strength is nevertheless poorly understood. Efficient nonlinear (NL) ultrasound methods have been widely developed for nondestructive testing and geophysical applications to detect microdamage. Moreover it has been reported that elastic nonlinearities increase with induced damage. We propose to monitor trabecular bone microdamage using a NL wave coupling technique. Ultrasonic short bursts times of flight (TOF) are modulated as result of NL interaction with a low-frequency (LF) wave in the medium. TOF modulation (TOFM), or propagation velocity variations, are directly related to NL elasticity variations. This technique allows measuring the instantaneous TOFM as a function of the LF pressure. It is thus possible to analyze separately elasticity variations in tension and in compression, and to distinguish the tension to compression phase from the compression to tension phase (hysteresis). In several trabecular bone samples, different TOFM amplitudes in tension and in compression are observed, probably due to microdamage. For increasing damage levels progressively induced by quasi-static compression testing, linear and nonlinear ultrasound parameters are compared to biomechanical parameters.
- 31 December 2007
- Published by Elsevier in Journal of Biomechanics
- Vol. 40, S161
Parametric subject-specific model for in vivo 3D reconstruction using bi-planar X-rays: Application to the upper femoral extremity
- 31 December 2007
- Published by Elsevier in Journal of Biomechanics
- Vol. 40, S161
Parametric subject-specific model for in vivo 3D reconstruction using bi-planar X-rays: Application to the upper femoral extremity
- 1 February 2006
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 9 (1) , 1-5
3D reconstruction of the pelvis from bi-planar radiography
3D personalized models are more and more requested for clinical and biomechanical studies. Techniques based on bi-planar X-rays present the advantage of a low radiation dose for the patient. However, up to now, such techniques have shown limited accuracy in the case of pelvis reconstruction. This study proposes and validates a method providing accurate 3D personalized model of the pelvis from bi-planar X-rays. The algorithm is based on the fast computation of an initial solution followed by local deformations based on 2D anatomical points and contours that are digitized in both radiographs. Results were close to CT-scan reconstructions (mean difference 1.6 mm and differences under 4.3 mm for 95% of the points). Moreover, 3D morphometry of the pelvis could be obtained with an accuracy of 5%. This technique provides 3D patient specific model with a low radiation dose.
- 1 February 2006
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 9 (1) , 1-5
3D reconstruction of the pelvis from bi-planar radiography
3D personalized models are more and more requested for clinical and biomechanical studies. Techniques based on bi-planar X-rays present the advantage of a low radiation dose for the patient. However, up to now, such techniques have shown limited accuracy in the case of pelvis reconstruction. This study proposes and validates a method providing accurate 3D personalized model of the pelvis from bi-planar X-rays. The algorithm is based on the fast computation of an initial solution followed by local deformations based on 2D anatomical points and contours that are digitized in both radiographs. Results were close to CT-scan reconstructions (mean difference 1.6 mm and differences under 4.3 mm for 95% of the points). Moreover, 3D morphometry of the pelvis could be obtained with an accuracy of 5%. This technique provides 3D patient specific model with a low radiation dose.
- 14 June 2005
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 15 (4) , 264-269
Effect of a supercritical CO2 based treatment on mechanical properties of human cancellous bone
- 14 June 2005
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 15 (4) , 264-269
Effect of a supercritical CO2 based treatment on mechanical properties of human cancellous bone