Jussi Timonen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jussi Timonen has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
- Andrei V. Rybin
Department of Physics, P.O. Box 35, FIN-40014, University of Jyväskylä, Finland
3 shared publications - Marja Siitari-Kauppi
Department of Chemistry University of Helsinki Helsinki Finland
3 shared publications - T. Turpeinen
Department of Physics, University of Jyväskylä, FI-40014 Jyväskylä, Finland
3 shared publications - Andrei Rybin
Department of Physics, University of Jyväskylä, P.O. box 35, FIN-40351 Jyväskylä, Finland
2 shared publications G G Varzugin
2 shared publications- Georgii P. Miroshnichenko
St. Petersburg State University of Information Technologies, Mechanics, and Optics
2 shared publications
Latest Publications
- 1 June 2009
- Published by IOP Publishing in Journal of Statistical Mechanics: Theory and Experiment
- Vol. 2009 (06) , P06010
Impact states and energy dissipation in bouncing and non-bouncing droplets
- 1 June 2009
- Published by IOP Publishing in Journal of Statistical Mechanics: Theory and Experiment
- Vol. 2009 (06) , P06010
Impact states and energy dissipation in bouncing and non-bouncing droplets
- 1 May 2008
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 123 (5_Suppleme) , 3634
Array transducer applied to low-frequency guided wave ultrasonography: An in vivo study on human radius and tibia
Velocity (V FAS ) of a first arriving signal for f < 0.5 MHz is expected to have an enhanced sensitivity to endosteal osteoporotic changes as compared to using higher frequencies. In this study a group of males and females (aged 10‐87 years) was measured by using a new array probe (f c = 0.4 MHz) on the radius and tibia. In addition, peripheral quantitative computed tomography was used to assess the bone mineral density (BMD) and cortical thickness (CTh) at the same bone locations. Initial results (n=57) showed that the repeatability error of the V FAS data (CV rms ) was 0.5%. When V FAS data for the radius was plotted by age it characterized well, yet better than BMD or CTh, the typical growth and loss curve of bone. V FAS for the radius was strongly correlated with total BMD (r = 0.84, p < 0.001), cortical BMD (r = 0.77, p < 0.001), subcortical BMD (r = 0.66, p < 0.001) and CTh (r = 0.59, p < 0.001). Corresponding results for the tibia were similar but clearly weaker than those for the radius. In conclusion, the low‐frequency V FAS had good accuracy and it predicted well both the geometry and material properties throughout the cortex.
- 1 May 2008
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 123 (5_Suppleme) , 3634
Array transducer applied to low-frequency guided wave ultrasonography: An in vivo study on human radius and tibia
Velocity (V FAS ) of a first arriving signal for f < 0.5 MHz is expected to have an enhanced sensitivity to endosteal osteoporotic changes as compared to using higher frequencies. In this study a group of males and females (aged 10‐87 years) was measured by using a new array probe (f c = 0.4 MHz) on the radius and tibia. In addition, peripheral quantitative computed tomography was used to assess the bone mineral density (BMD) and cortical thickness (CTh) at the same bone locations. Initial results (n=57) showed that the repeatability error of the V FAS data (CV rms ) was 0.5%. When V FAS data for the radius was plotted by age it characterized well, yet better than BMD or CTh, the typical growth and loss curve of bone. V FAS for the radius was strongly correlated with total BMD (r = 0.84, p < 0.001), cortical BMD (r = 0.77, p < 0.001), subcortical BMD (r = 0.66, p < 0.001) and CTh (r = 0.59, p < 0.001). Corresponding results for the tibia were similar but clearly weaker than those for the radius. In conclusion, the low‐frequency V FAS had good accuracy and it predicted well both the geometry and material properties throughout the cortex.
- 1 January 2008
- Published by Springer Nature in MRS Proceedings
- Vol. 1124
Physical Rock Matrix Characterization: Structural and Mineralogical Heterogeneities in Granite
Evaluation of the transport and retardation properties of rock matrices that serve as host rock for nuclear waste repositories necessitates their thorough pore-space characterization. Relevant properties to be quantified include the diffusion depth and volume adjacent to water conducting features. The bulk values of these quantities are not sufficient due to the heterogeneity of mineral structure on the scale of the expected transport/interaction distances. In this work the 3D pore structure of altered granite samples with porosities of 5 to 15%, taken next to water conducting fractures at 180 200 m depth in Sievi, Finland, was studied. Characterization of diffusion pathways and porosity were based on quantitative autoradiography of rock sections impregnated with C14-labelled polymethylmethacrylate (PMMA). Construction of 3D structure from PMMA autoradiographs was tested. The PMMA method was augmented by field emission scanning electron microscopy and energy-dispersive X-ray analyses (FESEM/EDAX) in order to study small pore-aperture regions in more detail and to identify the corresponding minerals. The 3D distribution of minerals and their abundances were determined by X-ray microtomography. Combining the mineral specific porosity found by the PMMA method with these distributions provided us with a 3D porosity distribution in the rock matrix.
- 1 January 2008
- Published by Springer Nature in MRS Proceedings
- Vol. 1124
Physical Rock Matrix Characterization: Structural and Mineralogical Heterogeneities in Granite
Evaluation of the transport and retardation properties of rock matrices that serve as host rock for nuclear waste repositories necessitates their thorough pore-space characterization. Relevant properties to be quantified include the diffusion depth and volume adjacent to water conducting features. The bulk values of these quantities are not sufficient due to the heterogeneity of mineral structure on the scale of the expected transport/interaction distances. In this work the 3D pore structure of altered granite samples with porosities of 5 to 15%, taken next to water conducting fractures at 180 200 m depth in Sievi, Finland, was studied. Characterization of diffusion pathways and porosity were based on quantitative autoradiography of rock sections impregnated with C14-labelled polymethylmethacrylate (PMMA). Construction of 3D structure from PMMA autoradiographs was tested. The PMMA method was augmented by field emission scanning electron microscopy and energy-dispersive X-ray analyses (FESEM/EDAX) in order to study small pore-aperture regions in more detail and to identify the corresponding minerals. The 3D distribution of minerals and their abundances were determined by X-ray microtomography. Combining the mineral specific porosity found by the PMMA method with these distributions provided us with a 3D porosity distribution in the rock matrix.
- 1 March 2007
- Published by American Physical Society (APS) in Physical Review E
- Vol. 75 (3) , 036301
Intrusion of nonwetting liquid in paper
The saturation curve of a sample of paper board was measured with mercury-intrusion porosimetry, and the three-dimensional structure of its pore space was determined by x-ray tomographic imaging. Ab initio numerical simulation of intrusion on the tomographic reconstruction, based on the lattice-Boltzmann method, was in excellent agreement with the measured saturation curve. A numerical invasion-percolation simulation in the same tomographic reconstruction showed good agreement with the lattice-Boltzmann simulation. The access function of the sample, determined from the saturation curve and the pore-throat distribution determined from the tomographic reconstruction, indicated that the ink-bottle effect is significant in paperlike materials.
- 1 March 2007
- Published by American Physical Society (APS) in Physical Review E
- Vol. 75 (3) , 036301
Intrusion of nonwetting liquid in paper
The saturation curve of a sample of paper board was measured with mercury-intrusion porosimetry, and the three-dimensional structure of its pore space was determined by x-ray tomographic imaging. Ab initio numerical simulation of intrusion on the tomographic reconstruction, based on the lattice-Boltzmann method, was in excellent agreement with the measured saturation curve. A numerical invasion-percolation simulation in the same tomographic reconstruction showed good agreement with the lattice-Boltzmann simulation. The access function of the sample, determined from the saturation curve and the pore-throat distribution determined from the tomographic reconstruction, indicated that the ink-bottle effect is significant in paperlike materials.
- 1 October 2004
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 116 (4_Suppleme) , 2492
In vitro comparative study of three devices based on ultrasonic axial transmission
In the axial transmission technique the velocity of waves propagating in the direction of bone axis is used to characterize cortical bone (radius, tibia, etc.). Corresponding clinically used devices are based on a long wavelength approach (typical frequency around 200 kHz) or shorter wavelength (typical frequency around 1 MHz) compared to bone thickness. They differ also by the methods of wave velocity evaluation. The aim of this study is to compare the sensitivity to bone properties of three representative devices using an in vitro investigation of the same specimens coupled with x‐ray determination of bone properties. The moderate correlation between velocities suggests an important impact of site‐matching. Among higher frequency devices, the one associated to the bidirectional probe provided generally higher correlation with bone properties than conventional axial transmission. The high‐frequency devices are less sensitive to cortical thickness, CSA and trabecular BMD than the low‐frequency device because high‐frequency waves interrogate a thinner cortical layer than low‐frequency waves. Our results suggest that different axial transmission approaches reflect different bone properties. Therefore, a multi‐frequency technique might be useful in probing different bone properties at the same time (e.g., cortical thickness and BMD).
- 1 October 2004
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 116 (4_Suppleme) , 2492
In vitro comparative study of three devices based on ultrasonic axial transmission
In the axial transmission technique the velocity of waves propagating in the direction of bone axis is used to characterize cortical bone (radius, tibia, etc.). Corresponding clinically used devices are based on a long wavelength approach (typical frequency around 200 kHz) or shorter wavelength (typical frequency around 1 MHz) compared to bone thickness. They differ also by the methods of wave velocity evaluation. The aim of this study is to compare the sensitivity to bone properties of three representative devices using an in vitro investigation of the same specimens coupled with x‐ray determination of bone properties. The moderate correlation between velocities suggests an important impact of site‐matching. Among higher frequency devices, the one associated to the bidirectional probe provided generally higher correlation with bone properties than conventional axial transmission. The high‐frequency devices are less sensitive to cortical thickness, CSA and trabecular BMD than the low‐frequency device because high‐frequency waves interrogate a thinner cortical layer than low‐frequency waves. Our results suggest that different axial transmission approaches reflect different bone properties. Therefore, a multi‐frequency technique might be useful in probing different bone properties at the same time (e.g., cortical thickness and BMD).
- 1 May 2004
- Published by IOP Publishing in Journal of Optics B: Quantum and Semiclassical Optics
- Vol. 6 (5) , S392-S396
Collapse in the symmetric Gross–Pitaevskii equation
- 1 May 2004
- Published by IOP Publishing in Journal of Optics B: Quantum and Semiclassical Optics
- Vol. 6 (5) , S392-S396
Collapse in the symmetric Gross–Pitaevskii equation
- 12 February 2004
- Published by American Physical Society (APS) in Physical Review A
- Vol. 69 (2) , 023607
Singularity formation in the Gross-Pitaevskii equation and collapse in Bose-Einstein condensates
We study the mechanisms of collapse of the condensate wave function in the Gross-Pitaevskii theory with attractive interparticle interaction. We reformulate the Gross-Pitaevskii equation as Newton’s equations for a flux of particles, and introduce the collapsing fraction of particles. We assume that this collapsing fraction is expelled from the condensate due to dissipation. Using this hypothesis we analyze the dependence of the collapse behavior on the initial conditions. We find that, for a properly chosen negative scattering length, the remnant fraction of atoms becomes larger when the initial aspect ratio of the condensate is increased.
- 12 February 2004
- Published by American Physical Society (APS) in Physical Review A
- Vol. 69 (2) , 023607
Singularity formation in the Gross-Pitaevskii equation and collapse in Bose-Einstein condensates
We study the mechanisms of collapse of the condensate wave function in the Gross-Pitaevskii theory with attractive interparticle interaction. We reformulate the Gross-Pitaevskii equation as Newton’s equations for a flux of particles, and introduce the collapsing fraction of particles. We assume that this collapsing fraction is expelled from the condensate due to dissipation. Using this hypothesis we analyze the dependence of the collapse behavior on the initial conditions. We find that, for a properly chosen negative scattering length, the remnant fraction of atoms becomes larger when the initial aspect ratio of the condensate is increased.
- 7 November 2003
- Published by American Physical Society (APS) in Physical Review E
- Vol. 68 (5) , 051103
Effect of a columnar defect on the shape of slow-combustion fronts
We report experimental results for the behavior of slow-combustion fronts in the presence of a columnar defect with enhanced or reduced driving, and compare them with those of mean-field theory. We also compare them with simulation results for an analogous problem of driven flow of particles with hard-core repulsion (ASEP) and a single defect bond with a different hopping probability. The difference in the shape of the front profiles for enhanced vs reduced driving in the defect clearly demonstrates the existence of a Kardar-Parisi-Zhang-type nonlinear term in the effective evolution equation for the slow-combustion fronts. We also find that slow-combustion fronts display a faceted form for large enough enhanced driving, and that there is a corresponding increase then in the average front speed. This increase in the average front speed disappears at a nonzero enhanced driving in agreement with the simulated behavior of the ASEP model.
- 7 November 2003
- Published by American Physical Society (APS) in Physical Review E
- Vol. 68 (5) , 051103
Effect of a columnar defect on the shape of slow-combustion fronts
We report experimental results for the behavior of slow-combustion fronts in the presence of a columnar defect with enhanced or reduced driving, and compare them with those of mean-field theory. We also compare them with simulation results for an analogous problem of driven flow of particles with hard-core repulsion (ASEP) and a single defect bond with a different hopping probability. The difference in the shape of the front profiles for enhanced vs reduced driving in the defect clearly demonstrates the existence of a Kardar-Parisi-Zhang-type nonlinear term in the effective evolution equation for the slow-combustion fronts. We also find that slow-combustion fronts display a faceted form for large enough enhanced driving, and that there is a corresponding increase then in the average front speed. This increase in the average front speed disappears at a nonzero enhanced driving in agreement with the simulated behavior of the ASEP model.