Matthias C. M. Klotz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Matthias C. M. Klotz has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Thomas Dreher
Clinic for Orthopedic and Trauma Surgery, University Hospital Heidelberg, Heidelberg, Germany
9 shared publications - Sebastian Immanuel Wolf
Clinic for Orthopedics, Heidelberg University Hospital, Heidelberg, Germany
8 shared publications - Daniel Walter Werner Heitzmann
Heidelberg University Clinics
5 shared publications - Michael W. Maier
Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Schlierbacher Landstrasse 200a, 69118, Heidelberg, Germany.
4 shared publications - Mirjam Niklasch
Clinic for Orthopaedic and Trauma Surgery, University Hospital Heidelberg, Heidelberg, Germany
4 shared publications - Felix Zeifang
Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Schlierbacher Landstraße 200a, D-69118, Heidelberg, Germany
3 shared publications
Latest Publications
- Open Access
- 1 September 2018
- Published by Elsevier in New Microbes and New Infections
- Vol. 25, 14-15
First isolation of Mycoplasma canis from human tissue samples after a dog bite
- 1 September 2018
- Published by Elsevier in New Microbes and New Infections
- Vol. 25, 14-15
Open AccessFirst isolation of Mycoplasma canis from human tissue samples after a dog bite
- 28 August 2018
- Published by Elsevier in Gait & Posture
- Vol. 66, 172-180
How do children with bilateral spastic cerebral palsy manage walking on inclines?
- 28 August 2018
- Published by Elsevier in Gait & Posture
- Vol. 66, 172-180
How do children with bilateral spastic cerebral palsy manage walking on inclines?
- 1 March 2018
- Published by Elsevier in Gait & Posture
- Vol. 61, 183-187
Long-term development of overcorrection after femoral derotation osteotomy in children with cerebral palsy
- 1 March 2018
- Published by Elsevier in Gait & Posture
- Vol. 61, 183-187
Long-term development of overcorrection after femoral derotation osteotomy in children with cerebral palsy
- 1 February 2018
- Published by Elsevier in Gait & Posture
- Vol. 60, 217-224
Does additional patella tendon shortening influence the effects of multilevel surgery to correct flexed knee gait in cerebral palsy: A randomized controlled trial
- 1 February 2018
- Published by Elsevier in Gait & Posture
- Vol. 60, 217-224
Does additional patella tendon shortening influence the effects of multilevel surgery to correct flexed knee gait in cerebral palsy: A randomized controlled trial
- 23 December 2016
- Published by Springer Nature in World Journal of Pediatrics
- Vol. 13 (4) , 353-359
Distal femoral extension and shortening osteotomy as a part of multilevel surgery in children with cerebral palsy
Background There are several reports describing an increase in anterior pelvic tilt after hamstring lengthening in children with cerebral palsy (CP). Distal femoral extension and shortening osteotomy (DFESO) is an alternative treatment for correction of flexed knee gait, but investigations analyzing outcome and influence on adjacent joint are few in the literature. The purpose of this study was to analyze the influence of DFESO on knee and pelvis in children with CP. Furthermore, it was of interest if an additional patellar tendon advancement (PA) influences outcome. Methods In this retrospective study, 31 limbs of 22 children (GMFCS I-III; mean age: 12.1±3.1 years), who received DFESO were included and kinematic parameters (knee, pelvis) measured by 3-D-gait analysis were compared before and at least 1 year after surgery (mean follow-up period: 15.6 months). Results After surgery, during stance phase minimum knee flexion improved significantly by 20.5° (PP=0.045). In 16 limbs, the postoperative increase in maximum anterior pelvic tilt was more than 5°. Limbs who received an additional PA showed the biggest increase in anterior pelvic tilt. Conclusions DFESO is an effective method for correction of flexed knee gait in children with CP. Furthermore, the results of this study indicate that DFESO may lead to an increase in anterior pelvic tilt, which may lead to a recurrence of flexed knee gait. In this context, PA seemed to aggravate the effect on the pelvis.
- 23 December 2016
- Published by Springer Nature in World Journal of Pediatrics
- Vol. 13 (4) , 353-359
Distal femoral extension and shortening osteotomy as a part of multilevel surgery in children with cerebral palsy
Background There are several reports describing an increase in anterior pelvic tilt after hamstring lengthening in children with cerebral palsy (CP). Distal femoral extension and shortening osteotomy (DFESO) is an alternative treatment for correction of flexed knee gait, but investigations analyzing outcome and influence on adjacent joint are few in the literature. The purpose of this study was to analyze the influence of DFESO on knee and pelvis in children with CP. Furthermore, it was of interest if an additional patellar tendon advancement (PA) influences outcome. Methods In this retrospective study, 31 limbs of 22 children (GMFCS I-III; mean age: 12.1±3.1 years), who received DFESO were included and kinematic parameters (knee, pelvis) measured by 3-D-gait analysis were compared before and at least 1 year after surgery (mean follow-up period: 15.6 months). Results After surgery, during stance phase minimum knee flexion improved significantly by 20.5° (PP=0.045). In 16 limbs, the postoperative increase in maximum anterior pelvic tilt was more than 5°. Limbs who received an additional PA showed the biggest increase in anterior pelvic tilt. Conclusions DFESO is an effective method for correction of flexed knee gait in children with CP. Furthermore, the results of this study indicate that DFESO may lead to an increase in anterior pelvic tilt, which may lead to a recurrence of flexed knee gait. In this context, PA seemed to aggravate the effect on the pelvis.
- 1 January 2016
- Published by Elsevier in Research in Developmental Disabilities
- Vol. 48, 186-192
The influence of timing of knee recurvatum on surgical outcome in cerebral palsy
- 1 January 2016
- Published by Elsevier in Research in Developmental Disabilities
- Vol. 48, 186-192
The influence of timing of knee recurvatum on surgical outcome in cerebral palsy
- Open Access
- 1 October 2015
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 16 (1) , 1-7
Are there differences between stemless and conventional stemmed shoulder prostheses in the treatment of glenohumeral osteoarthritis?
Conventional stemmed anatomical shoulder prostheses are widely used in the treatment of glenohumeral osteoarthritis. The stemless shoulder prosthesis, in contrast, is a new concept, and fewer outcome studies are available. Therefore, the purpose of the study was to investigate the early functional outcome and postoperative proprioception of a stemless prosthesis in comparison with a standard stemmed anatomic shoulder prosthesis. Twelve patients (mean age 68.3 years [SD ± 5.4]; 5 female, 7 male) with primary glenohumeral osteoarthritis of the shoulder were enrolled, who underwent total shoulder arthroplasty (TSA) with a stemless total shoulder prosthesis, Total Evolution Shoulder System (TESS®; Biomed, France). The control group consisted of twelve (age and gender matched) patients (mean age 67.8 years; [SD ± 7.1]; 9 female, 3 male), getting a TSA with a standard anatomic stemmed prosthesis, Aequalis® Shoulder (Tournier, Lyon, France). Patients were examined the day before and six months after surgery. The pre- and postoperative Constant Score (CS) was evaluated and proprioception was measured in a 3D video motion analysis study using an active angle-reproduction (AAR) test. Comparing the postoperative CS, there was no significant difference between the groups treated with the TESS® prosthesis (48.0 ± 13.8 points) and the Aequalis® prosthesis (49.3 ± 8.6 points; p = 0.792). There was no significant difference in postoperative proprioception between the TESS® group (7.2° [SD ± 2.8]) and the Aequalis® group(8.7° [SD ± 2.7]; p = 0.196), either. Comparison of in the results of CS and AAR test pre- and postoperatively showed no significant differences between the groups. In patients with glenohumeral osteoarthritis, treated with TSA, the functional and the proprioceptive outcome is comparable between a stemless and a standard stemmed anatomic shoulder prosthesis at early followup. Further follow-up is necessary regarding the long-term performance of this prosthesis. Current Controlled Trials DRKS 00007528 . Registered 17 November 2014
- 1 October 2015
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 16 (1) , 1-7
Open AccessAre there differences between stemless and conventional stemmed shoulder prostheses in the treatment of glenohumeral osteoarthritis?
Conventional stemmed anatomical shoulder prostheses are widely used in the treatment of glenohumeral osteoarthritis. The stemless shoulder prosthesis, in contrast, is a new concept, and fewer outcome studies are available. Therefore, the purpose of the study was to investigate the early functional outcome and postoperative proprioception of a stemless prosthesis in comparison with a standard stemmed anatomic shoulder prosthesis. Twelve patients (mean age 68.3 years [SD ± 5.4]; 5 female, 7 male) with primary glenohumeral osteoarthritis of the shoulder were enrolled, who underwent total shoulder arthroplasty (TSA) with a stemless total shoulder prosthesis, Total Evolution Shoulder System (TESS®; Biomed, France). The control group consisted of twelve (age and gender matched) patients (mean age 67.8 years; [SD ± 7.1]; 9 female, 3 male), getting a TSA with a standard anatomic stemmed prosthesis, Aequalis® Shoulder (Tournier, Lyon, France). Patients were examined the day before and six months after surgery. The pre- and postoperative Constant Score (CS) was evaluated and proprioception was measured in a 3D video motion analysis study using an active angle-reproduction (AAR) test. Comparing the postoperative CS, there was no significant difference between the groups treated with the TESS® prosthesis (48.0 ± 13.8 points) and the Aequalis® prosthesis (49.3 ± 8.6 points; p = 0.792). There was no significant difference in postoperative proprioception between the TESS® group (7.2° [SD ± 2.8]) and the Aequalis® group(8.7° [SD ± 2.7]; p = 0.196), either. Comparison of in the results of CS and AAR test pre- and postoperatively showed no significant differences between the groups. In patients with glenohumeral osteoarthritis, treated with TSA, the functional and the proprioceptive outcome is comparable between a stemless and a standard stemmed anatomic shoulder prosthesis at early followup. Further follow-up is necessary regarding the long-term performance of this prosthesis. Current Controlled Trials DRKS 00007528 . Registered 17 November 2014
- 1 April 2015
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- Vol. 101 (2) , 191-196
Can reverse shoulder arthroplasty in post-traumatic revision surgery restore the ability to perform activities of daily living?
- 1 April 2015
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- Vol. 101 (2) , 191-196
Can reverse shoulder arthroplasty in post-traumatic revision surgery restore the ability to perform activities of daily living?
- Open Access
- 13 November 2014
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 9 (1) , 109
Bone quality assessment for total hip arthroplasty with intraoperative trabecular torque measurements
In cases of poor bone quality, intraoperative torque measurement might be an alternative to preoperative dual-energy X-ray absorptiometry (DXA) to assess bone quality in total hip arthroplasty (THA). Trabecular peak torque measurement was applied in 14 paired fresh frozen human femurs. Here, a 6.5 × 23 mm wingblade was inserted into the proximal femur without harming the lateral cortical bone. Further tests of the proximal femur also evaluated bone strength (DXA, micro-computed tomography (μCT), monoaxial compression test), and the results were compared to the trabecular torque measurement. Student's t-test was used to compare the values of the groups. Pearson product–moment was applied to correlate the values of the peak torque measurement with the bone strength measured by DXA, μCT, and monoaxial compression test. In the femoral head, the mean trabecular peak torque was 4.38 ± 1.86 Nm. These values showed a strong correlation with the values of the DXA, the μCT, and the biomechanical load test (Pearson′s product–moment: DXA: 0.86, μCT-BMD: 0.80, load test: 0.85). Furthermore, the torque measurement showed a more pronounced correlation with the biomechanical load test compared to the DXA. The use of this method provides highly diagnostic information about bone quality. Since the approach was adjusted for THA, no harm of the lateral bone stock will result from this measurement during surgery. The results of this initial study employing small sample sizes indicate that this new method is as sensitive as DXA in predicting bone quality and may function as an intraoperative alternative to DXA in THA. Nevertheless, before this method will turn into clinical use, more research and clinical trials are necessary.
- 13 November 2014
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 9 (1) , 109
Open AccessBone quality assessment for total hip arthroplasty with intraoperative trabecular torque measurements
In cases of poor bone quality, intraoperative torque measurement might be an alternative to preoperative dual-energy X-ray absorptiometry (DXA) to assess bone quality in total hip arthroplasty (THA). Trabecular peak torque measurement was applied in 14 paired fresh frozen human femurs. Here, a 6.5 × 23 mm wingblade was inserted into the proximal femur without harming the lateral cortical bone. Further tests of the proximal femur also evaluated bone strength (DXA, micro-computed tomography (μCT), monoaxial compression test), and the results were compared to the trabecular torque measurement. Student's t-test was used to compare the values of the groups. Pearson product–moment was applied to correlate the values of the peak torque measurement with the bone strength measured by DXA, μCT, and monoaxial compression test. In the femoral head, the mean trabecular peak torque was 4.38 ± 1.86 Nm. These values showed a strong correlation with the values of the DXA, the μCT, and the biomechanical load test (Pearson′s product–moment: DXA: 0.86, μCT-BMD: 0.80, load test: 0.85). Furthermore, the torque measurement showed a more pronounced correlation with the biomechanical load test compared to the DXA. The use of this method provides highly diagnostic information about bone quality. Since the approach was adjusted for THA, no harm of the lateral bone stock will result from this measurement during surgery. The results of this initial study employing small sample sizes indicate that this new method is as sensitive as DXA in predicting bone quality and may function as an intraoperative alternative to DXA in THA. Nevertheless, before this method will turn into clinical use, more research and clinical trials are necessary.
- 1 November 2014
- Published by Elsevier in Research in Developmental Disabilities
- Vol. 35 (11) , 2950-2957
Motion analysis of the upper extremity in children with unilateral cerebral palsy—An assessment of six daily tasks
- 1 November 2014
- Published by Elsevier in Research in Developmental Disabilities
- Vol. 35 (11) , 2950-2957
Motion analysis of the upper extremity in children with unilateral cerebral palsy—An assessment of six daily tasks