CSChristine H. Shadle

Christine H. Shadle

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Christine H. Shadle has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The [s -- > ʃ] sound change in /str-/ contexts: how temporal changes in the acoustic spectrum affect fricative percept

    by Christine H. Shadle, Laura L. Koenig, Wei-Rong Chen

    Studies have documented a sound change in some English dialects whereby /s/ in the context /strV/ surfaces as [ʃtrV]. This can be interpreted as /s/ rounding for the rhotic being re-analyzed as [ʃ]. We recently measured F;M, the frequency of the main peak in mid-fricative spectra, in seven adults producing words with /s/ and /ʃ/ across phonetic contexts and compared the acoustics to perceptual rankings on an [ʃ] to [s] scale. One speaker exhibited a perceived sound change; two, partial sound changes. It was shown that F;M was correlated with the perceptual rankings for /strV/ words. However, in all speakers, lowered F;M for /s/ in labial contexts did not affect percepts. The time course of lip rounding and tongue-tip retraction in /strV/ could help differentiate coarticulation versus a phonemic change. Interestingly, however, X-Ray Microbeam data [Iskarous, K. et al. (2011) Articulatory-acoustic kinematics of /s/, J. Acoust. Soc. Am. 129, 944-954] showed that / s/ constriction location was constant over time except in /str-/ context. This study will assess the amount and timing of F;M lowering, its perceptual consequences and likely articulatory causes, to gain more insight into the [strV] -- > [ʃtrV] sound change.

  • Open Access

    The [s → ʃ] sound change in /str-/ contexts: Acoustic and perceptual results

    by Christine H. Shadle, Laura Koenig, Wei-Rong Chen

    Since 1995 [Shapiro, M. A case of distant assimilation: /str/ → /ʃ tr/. American Speech, 70, 101–107], many studies have noted a sound change occurring in some dialects of English with /s/ in the context /strV/ surfacing as [ʃ trV]. At first the phenomenon was restricted to certain contexts, though studies disagree on which; increasingly, those who produce the change do so in all contexts. Is the fricative is truly identical to / ʃ / as produced by the same speaker? Or is it acoustically on a continuum, though perhaps perceived as one category or the other? In a corpus of real words, speaker W1 was perceived as exhibiting the sound change, and her /s/ spectra in /str/ context were distinctly different from her /s/ spectra in other contexts. However, speaker M1, though not perceived as exhibiting the sound change, showed spectral differences similar to W1’s. Here, acoustic measures that we have developed to characterize the [s → ʃ] difference will be applied to a more extensive corpus, and will also be related to results of formal perception tasks for multiple listeners. It is anticipated that a continuum will emerge, with perceptual classification into categories resulting in the reported sound change.

  • Open Access

    F0-induced formant measurement errors result in biased variabilities

    by Wei-Rong Chen, D. H. Whalen, Christine H. Shadle

    Many developmental studies attribute reduction of acoustic variability to increasing motor control. However, linear prediction-based formant measurements are known to be biased toward the nearest harmonic of F0, especially at high F0s. Thus, the amount of reported formant variability generated by changes in F0 is unknown. Here, 470 000 vowels were synthesized, mimicking statistics reported in four developmental studies, to estimate the proportion of formant variability that can be attributed to F0 bias, as well as other formant measurement errors. Results showed that the F0-induced formant measurements errors are large and systematic, and cannot be eliminated by a large sample size.


  • How much formant variability in linear prediction-based measurements can be explained by F0 variability?

    by Wei-Rong Chen, D. H. Whalen, Christine H. Shadle

    Previous studies have used speech variability as a measure of speech development; for instance, children reduce the variability in their formant frequencies as they grow, indicating increases in speech motor control. However, formant measurements in most of these studies are computed using variants of linear prediction coding (LPC), which is known to exhibit a bias towards the nearest harmonic of F0, especially at high F0 [Shadle et al. (2016). JASA. 139(2), 713–727]. The proportion of the reported formant variabilities that can be attributed to changes in F0 is still unknown; thus, the true variability in formant frequency is also unknown. Therefore, we used published values of formant and F0 variabilities for /a/ produced by children (age range: 4~19 + yrs), and, for each age group, we synthesized 1000 vowels with the same formants (F1~F3) fixed at the reported group means, but randomly varied F0 using a normal distribution (μ = F0 group mean, σ = F0 standard deviation (SD)). We then measured formants in those synthesized vowels using LPC; the SDs of the measured formants were considered to be the F0-biased formant variability (true formant SD = 0). A ratio of F0-biased SD to reported formant SD for each age group indicates how much of the reported formant variability can be explained by F0 changing in children’s speech. The results show, on average, that the purported formant variabilities in previous studies that can be explained by F0 bias are 82.2 % for F1, 31.1% for F2, and 17.4% for F3.

  • F.V. Hunt and my travels with fricative consonants

    by Christine H. Shadle

    My training as an electrical engineer aligned well with the way acoustics of speech was modeled, as I learned when working at Bell Laboratories and then in Ken Stevens’ lab at MIT. However, fricative consonants require turbulence noise for their production; studying them for my Ph.D. led me toward aeroacoustics and testing whether circuit models really were adequate for modeling fricatives. The 1984–1985 Hunt and the NATO 1985–1986 postdoctoral fellowships gave me two years in which to learn more. I studied flow measurement methods at MIT’s Mechanical Engineering Department (supervised by Prof. Richard Lyon), then used them in experiments on mechanical models of fricatives and of vocal folds at the Institute of Sound and Vibration Research (ISVR) at the University of Southampton, UK (supervised by Dr. Stephen Elliott and Dr. Phil Nelson). At the Department of Speech Communication and Music Acoustics at KTH, Stockholm, Sweden, supervised by Prof. Gunnar Fant, I analyzed human speech and experimented with vocal tract imaging. As academic staff at the University of Southampton I collaborated with ISVR and KTH colleagues and others on the aeroacoustic aspects of speech, vocal tract imaging and speech analysis methods; since 2004 I have continued this research at Haskins Laboratories.

  • Use of H1-H2 to quantify formant tuning for notes and portions of the vibrato cycle in the second passaggio of a professional female singer

    by Richard C. Lissemore, Christine H. Shadle, Kevin Roon, D. H. Whalen

    Singing voice pedagogy emphasizes that an acoustic change occurs in standard, classical, techniqued soprano voice between the musical notes D5♮ (587 Hz) and F5♮ (698 Hz). For low vowels, this involves a transition from tuning of the second resonance to the second harmonic (F2/H2) to tuning of the first resonance to the fundamental (F1/F0). In this single-subject study, we quantified the acoustics of this transition as the amplitude difference between the first and second harmonics (H1-H2). Results showed a clear and substantial change from negative to positive H1-H2 values at a pivot point between E5♭ and E5♮, implying the resonance tuning. Non-techniqued singing, with the same singer, showed no such change. F0 fluctuation (vibrato) of ±90 cent at the pivot point resulted in positive H1-H2 values at vibrato maxima and negative ones at vibrato minima. Additionally, H1-H2 values were consistently higher at vibrato maxima than minima throughout the transition area. Potential explanations for the latter result are: (i) vocal tract resonances are located just above the sung F0, or (ii) the vibrato cycle is accompanied by an articulatory change, possibly laryngeal movement. This illustrates the intricacies of formant tuning and suggests future possibilities for numerical assessment of vocal technique.

  • Aeroacoustic consequences of tongue troughs in labiodentals

    by Christine H. Shadle, Hosung Nam, A. Katsika, Mark Tiede, D. H. Whalen

    It has long been accepted that the main constriction for fricatives /f, v/ is formed by the lower lip pressing against the upper teeth, thus allowing the tongue to freely coarticulate with preceding and following segments. Here, electromagnetic articulometry data were obtained from 5 subjects in a study of tongue troughs, defined as a discontinuity in anticipatory coarticulation, such as when the tongue drops during a bilabial consonant in /ii/ context. The corpus included /f/ and /v/ in VC(C)V contexts, where V = /i/ for C= /v/, and V = {/i a u/} for C= /f/. The tongue moved down and back for /f/ in all vowel contexts; in /iC(C)i/ context, the troughs were deeper for long (VCCV) than short labial consonants, as predicted, and deeper for /f/ than for /p, b, v, m/, which was unexpected. There seems to be a secondary gesture specifying that the tongue be down during labiodental fricatives. Our hypothesis is that lowering the tongue for /f/ ensures that the airflow resistance will be due only to the labiodental constriction, thus providing an aeroacoustic advantage for the onset of turbulence. This is supported by comparison of asymmetric vowel contexts (e.g., /uffi/-/iffu/ tokens); tongue dorsum and blade sensors show the tongue moving quickly away from /i/ to /f/ position, in contrast to movement from /u/ to /f/. Aerodynamic considerations thus appear to be actively incorporated into the speech motor plan. [Work supported by NIH grant DC-002717.]

  • Stability of the main resonance frequency of fricatives despite changes in the first spectral moment

    by Christine H. Shadle, Wei-Rong Chen, D. H. Whalen

    Spectral moments have been taken as the primary measurements of fricatives, but resonances are evident as well. To contrast the two, the X-ray Microbeam Database (XRMB) was used to investigate acoustic and articulatory behavior in [s] for 10 /sVd/ words and 9 /sCV*/ words for 24 subjects as in a previous study [Iskarous et al., JASA 129:2, 2011]. Spectral parameters were adapted from analysis of an acoustic corpus of adolescents’ [s] production [Koenig et al., JSLHR 56, Aug. 2013]. The time series of the frequency of the main resonance (FM) and the first spectral moment (M1) were compared to the constriction location estimated from the most anterior tongue pellet T1. FM quickly settles into a constant value largely determined by the position of T1; vowel context affects FM throughout [s] for some subjects. M1 however rises and then falls during [s], matching jaw-raising behavior (as estimated by the y-component of the jaw pellet) and correlated with an estimate of high-frequency energy. The results show that some aspects of the fricative acoustics behave differently over time and by context. It remains to be seen what the perceptual consequences of these differences are. [Work supported by NIH NIDCD-DC-002717.]


  • An electromagnetic articulometer study of tongue and lip troughs

    by Christine H. Shadle, Hosung Nam, Argyro Katsika, Mark Tiede, D H Whalen

    Troughs, which are a discontinuity in anticipatory coarticulation (Perkell 1968), have been shown to occur in the tongue body in /ipi/ and lips in /usu/. An electromagnetic articulometer (EMA) study of a single subject reported previously showed that intraoral pressure during the consonant could not be solely responsible for the downwards tongue body movement observed during the labial consonants (/p, b, m, f, v/); results supported the hypothesis of a secondary tongue gesture during the consonant. Lip troughs during /s/ in rounded contexts were more ambiguous, possibly because of inconsistencies in corpus design. Six new subjects have been recorded using a WAVE EMA system and a revised corpus. Tongue trough magnitudes decreased in the order /f, v/ > /p, b/ > /m/, serving to disprove the aerodynamic hypothesis; they were deeper for long than short consonants (e.g., [iffi] > [ifi]), and converged to the same point in asymmetric vowel contexts. The same type of convergence during the consonant was observed for lip aperture during V1C(C)V2 combinations, where C = {/s, ʃ/}. These recent results thus support both tongue and lip troughs being caused by secondary gestures of consonants. [Work supported by NIH NIDCD-DC-02717.]

  • Comparing measurement errors for formants in synthetic and natural vowels

    by Christine H. Shadle, Hosung Nam, D. H. Whalen

    The measurement of formant frequencies of vowels is among the most common measurements in speech studies, but measurements are known to be biased by the particular fundamental frequency (F0) exciting the formants. Approaches to reducing the errors were assessed in two experiments. In the first, synthetic vowels were constructed with five different first formant (F1) values and nine different F0 values; formant bandwidths, and higher formant frequencies, were constant. Input formant values were compared to manual measurements and automatic measures using the linear prediction coding-Burg algorithm, linear prediction closed-phase covariance, the weighted linear prediction-attenuated main excitation (WLP-AME) algorithm [Alku, Pohjalainen, Vainio, Laukkanen, and Story (2013). J. Acoust. Soc. Am. 134(2), 1295–1313], spectra smoothed cepstrally and by averaging repeated discrete Fourier transforms. Formants were also measured manually from pruned reassigned spectrograms (RSs) [Fulop (2011). Speech Spectrum Analysis (Springer, Berlin)]. All but WLP-AME and RS had large errors in the direction of the strongest harmonic; the smallest errors occur with WLP-AME and RS. In the second experiment, these methods were used on vowels in isolated words spoken by four speakers. Results for the natural speech show that F0 bias affects all automatic methods, including WLP-AME; only the formants measured manually from RS appeared to be accurate. In addition, RS coped better with weaker formants and glottal fry.