ABAnthony J. Brammer

Anthony J. Brammer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Anthony J. Brammer has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Tony F. W. Embleton in the Acoustics Section, Physics Division, of the National Research Council of Canada (NRCC)

    by Anthony J. Brammer, Gilles Daigle, Michael Stinson, Floyd Toole

    Tony completed his PhD in three years at Imperial College (London) studying under Dr. R.W.B. Stephens. He then joined George Thiessen and Edgar Shaw at NRCC to form the core of what became arguably the most influential and productive research group in acoustics in Canada from the 1960s to the 1980s. An important activity was service to industry, a role Tony embraced by collaborating with industry associations, participating in committees and directing his research activities. Working with George Thiessen, he succeeded in reducing the noise of couch rolls, a major source of noise in paper making, by randomizing the pattern of holes through which air was sucked to dry the paper. Other successful noise control projects included staggered stator blades for gas turbine engines and mufflers for rock drills. Tony made seminal contributions to outdoor sound propagation and refined condenser microphone calibration. In addition to his research and outreach, he found time for professional service to the ASA and CAA, including serving as founding editor of what is now Canadian Acoustics, and to develop standards and mentor younger scientists, He is remembered for his cheerfulness and willingness to provide advice and engage in conversation on any and all topics.

  • Open Access

    Nancy Workshop 2023 on Hand-Transmitted Shock and High-Frequency Vibration

    by Hans Lindell, Paul Pitts, Anthony Brammer, Ronnie Lundstrom

    Since its initial publication in 1986, ISO 5439 has been unclear on the evaluation of isolated and repeated shock vibration. In 2015, an expert’s workshop was held in conjunction with the 13th International Conference that identified features of a vibration signal that may be important for predicting health outcomes, including high-frequency vibration and shock. Since then, ISO standards have been drafted on the measurement of shock and measurement of high-frequency vibrations, and in the European Union, a proposed revision of machinery supply legislation will require manufacturers to provide information on the average peak amplitude of acceleration. The Nancy Workshop introduced the issue of hand-transmitted (mechanical) shock (HTS) and work currently active within International Standards groups, and discussed options for defining HTS measurement. The workshop concluded that HTS is likely to present different risks to those of continuous hand–arm vibration, and that, therefore, there is a need for different metrics, and that high-frequency vibration is an important component of many HTS sources, e.g., impact wrenches, nail guns, riveting hammers, etc.; therefore, HTS evaluation should include higher frequencies of vibration, possibly up to 10 kHz.


  • Open Access

    Relating Occupational Exposure to Persistent Health Effects

    by Anthony J. Brammer, Magdalena F. Scholz

    The objectives of the Workshop are addressed using epidemiologic data from population groups in occupations involving exposure to hand-transmitted vibration and/or shocks. Pooled analyses demonstrate the limitations of the exposure–response relation in ISO 5349-1:2001, and that A(8) is inappropriate for calculating the daily exposure to shocks as well as to continuous vibration. Alternative frequency weightings and metrics for daily exposure are explored.


  • Open Access

    Onset of Vibration-Induced White Finger: Insight Derived from a Meta-Analysis of Exposed Workers

    by Magdalena F. Scholz, Anthony J. Brammer, Steffen Marburg

    A pooled analysis has been performed of population groups whose hands have been occupationally exposed to vibration to study exposure evaluation, using epidemiologic data selected from a published meta-analysis. While the analysis cannot confirm the accuracy of the exposure-response relation in ISO 5349-1:2001, it suggests that the relation provides a conservative estimate for the onset of vibration-induced white finger. The analysis also demonstrates that the procedures for calculating vibration exposure in the international standard may need revision.

  • Understanding speech when wearing communication headsets and hearing protectors with subband processing

    by Anthony J. Brammer, Gongqiang Yu, Eric R. Bernstein, Martin G. Cherniack, Donald R. Peterson, Jennifer B. Tufts

    An adaptive, delayless, subband feed-forward control structure is employed to improve the speech signal-to-noise ratio (SNR) in the communication channel of a circumaural headset/hearing protector (HPD) from 90 Hz to 11.3 kHz, and to provide active noise control (ANC) from 50 to 800 Hz to complement the passive attenuation of the HPD. The task involves optimizing the speech SNR for each communication channel subband, subject to limiting the maximum sound level at the ear, maintaining a speech SNR preferred by users, and reducing large inter-band gain differences to improve speech quality. The performance of a proof-of-concept device has been evaluated in a pseudo-diffuse sound field when worn by human subjects under conditions of environmental noise and speech that do not pose a risk to hearing, and by simulation for other conditions. For the environmental noises employed in this study, subband speech SNR control combined with subband ANC produced greater improvement in word scores than subband ANC alone, and improved the consistency of word scores across subjects. The simulation employed a subject-specific linear model, and predicted that word scores are maintained in excess of 90% for sound levels outside the HPD of up to ∼115 dBA.


  • Augmented warning sound detection for hearing protectors

    by Eric R. Bernstein, Anthony J. Brammer, Gongqiang Yu

    Perception of warning sounds, such as vehicle backup alarms, is reduced when hearing protection devices (HPDs) are worn. A cross-correlation approach is employed to detect a pre-selected warning sound and enable it to bypass the attenuation of the HPD while still attenuating the environmental noise. Computer simulation shows that the algorithm can detect the specified alarm at signal-to-environmental-noise ratios as low as −30 dB. Human subject testing of the algorithm, implemented on a modified commercial HPD, confirms the minimum detection threshold obtained in simulation, and demonstrates a 7 dB improvement in detection threshold compared with the unmodified HPD.


  • Open Access

    Frequency Weighting for Vibration-induced White Finger Compatible with Exposure-response Models

    by Anthony J. Brammer, Paul M. Pitts

    An analysis has been performed to derive a frequency weighting for the development of vibration-induced white finger (VWF). It employs a model to compare health risks for pairs of population groups that are selected to have similar health outcomes from operating power tools or machines with markedly different acceleration spectra (rock drills, chain saws, pavement breakers and motorcycles). The model defines the Relative Risk, RRf(trial), which is constructed from the ratio of daily exposures and includes a trial frequency weighting that is applied to the acceleration spectra. The trial frequency weighting consists of a frequency-independent primary frequency range, and subordinate frequency ranges in which the response to vibration diminishes, with cut-off frequencies that are changed to influence the magnitude of RRf(trial). The frequency weighting so derived when RRf(trial) = 1 is similar to those obtained by other methods (Whf, WhT). It consists of a frequency independent range from about 25 Hz to 500 Hz (–3 dB frequencies), with an amplitude cut-off rate of 12 dB/octave below 25 Hz and above 500 Hz. The range is compatible with studies of vasoconstriction in persons with VWF. The results provide further evidence that the ISO frequency weighting may be inappropriate for assessing the risk of developing VWF.


  • Henning E. von Gierke and human biodynamics

    by Anthony J. Brammer

    In addition to his well‐known involvement in protecting humans from exposure to excessive noise, Dr. Henning E. von Gierke was deeply involved in protecting humans from exposure to excessive mechanical shocks, impacts and vibration. From exploring the limits of survivability during the landing phase of space and aircraft capsules to the more everyday issues of occupational exposure to vibration, he provided scientific insight into problems and leadership in developing solutions. While most of Henning's contributions are buried in past literature, the spirit of his efforts lives on in a review chapter published in Harris' Shock and Vibration Handbook that I have had the privilege to co‐author with him through two editions, now extending back more than a decade. The challenge of encompassing the original content of his contribution while introducing the results of more recent research has, so far, yielded a composition that he has endorsed. Henning's involvement and interests in human biodynamics will be illustrated by examples taken from this work.