Bernd E. Winkler
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Bernd E. Winkler has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Andreas Koch
2 shared publicationsC.-M. Muth
Department of Anaesthesiology , University of Ulm , Prittwitzstrasse 43, 89073 Ulm , Germany
2 shared publicationsClaus-Martin Muth
2 shared publications- Andreas Koch
German Naval Medical Institute, 24119 Kiel, Germany
1 shared publication Anna Magdalena Eff
1 shared publicationClaus‐Martin Muth
Department of Anaesthesiology, University of Ulm, Ulm, Germany
1 shared publication
Latest Publications
- 1 August 2013
- Published by Elsevier in Resuscitation
- Vol. 84 (8) , 1137-1142
Efficacy of ventilation and ventilation adjuncts during in-water-resuscitation—A randomized cross-over trial
- 1 August 2013
- Published by Elsevier in Resuscitation
- Vol. 84 (8) , 1137-1142
Efficacy of ventilation and ventilation adjuncts during in-water-resuscitation—A randomized cross-over trial
- 21 May 2013
- Vol. 40 (2) , 155-63
Physical exercise might influence the risk of oxygen-induced acute neurotoxicity.
Hyperoxia can induce acute neurotoxicity with generalized seizures. Hyperoxia-induced reduction in cerebral blood flow velocity (CBFV) might be protective. It is unclear whether dynamic exercise during hyperoxia can overcome CBFV-reduction and thus possibly increase the risk of neurotoxicity. We studied CBFV with both-sided transcranial Doppler with fixed transducer-position and heart rate under increasing hyperoxic conditions in nine professional military oxygen divers. The divers performed dynamic exercise on a bicycle-ergometer in a hyperbaric chamber (ergometries I-III, 21kPa, 100kPa, 150kPa pO2), with continuous blood pressure (ergometries I, II), end-tidal CO2 (PetCO2; ergometry I) being measured. Systolic (CBFVsyst) and diastolic CBFV (CBFVdiast) readings at rest decreased with increasing pO2. During exercise, CBFVsyst and CBFVdiast significantly increased in parallel with increasing pO2, despite reduced flow velocities at rest. CBFVsyst increased from 65.0 +/- 11.3 cm/second at rest to 80.2 +/- 23.4cm/s during maximum workload (n.s.), diastolic from 14.5 +/- 4.1 cm/second to 15.6 +/- 7.5 cm/s (n.s.). PetCO2 increased from 43.4 +/- 7.8mmHg to 50.0 +/- 7.5mmHg. CBFVsyst increased from 58.2 +/- 16.5 cm/second to 99.7 +/- 17.0 cm/s (p<0.001), diastolic from 14.0 +/- 10.7 cm/second to 29.4 +/- 11.1 cm/second (p<0.01). CBFVsyst increased from 54.4 +/-15.0cm/second to 109.4 +/- 22.3cm/s (p<0.001), diastolic from 14.7 +/- 10.4 cm/second to 35.5 +/- 9.3 cm/second (p<0.01). Physical exercise overrules the decrease in CBFV during hyperoxia and leads to even higher CBFV-increases with increasing pO2. A tendency towards CO2 retainment with elevated PetCOz may be causative and thus heighten the risk of oxygen-induced neurotoxicity.
- 21 May 2013
- Vol. 40 (2) , 155-63
Physical exercise might influence the risk of oxygen-induced acute neurotoxicity.
Hyperoxia can induce acute neurotoxicity with generalized seizures. Hyperoxia-induced reduction in cerebral blood flow velocity (CBFV) might be protective. It is unclear whether dynamic exercise during hyperoxia can overcome CBFV-reduction and thus possibly increase the risk of neurotoxicity. We studied CBFV with both-sided transcranial Doppler with fixed transducer-position and heart rate under increasing hyperoxic conditions in nine professional military oxygen divers. The divers performed dynamic exercise on a bicycle-ergometer in a hyperbaric chamber (ergometries I-III, 21kPa, 100kPa, 150kPa pO2), with continuous blood pressure (ergometries I, II), end-tidal CO2 (PetCO2; ergometry I) being measured. Systolic (CBFVsyst) and diastolic CBFV (CBFVdiast) readings at rest decreased with increasing pO2. During exercise, CBFVsyst and CBFVdiast significantly increased in parallel with increasing pO2, despite reduced flow velocities at rest. CBFVsyst increased from 65.0 +/- 11.3 cm/second at rest to 80.2 +/- 23.4cm/s during maximum workload (n.s.), diastolic from 14.5 +/- 4.1 cm/second to 15.6 +/- 7.5 cm/s (n.s.). PetCO2 increased from 43.4 +/- 7.8mmHg to 50.0 +/- 7.5mmHg. CBFVsyst increased from 58.2 +/- 16.5 cm/second to 99.7 +/- 17.0 cm/s (p<0.001), diastolic from 14.0 +/- 10.7 cm/second to 29.4 +/- 11.1 cm/second (p<0.01). CBFVsyst increased from 54.4 +/-15.0cm/second to 109.4 +/- 22.3cm/s (p<0.001), diastolic from 14.7 +/- 10.4 cm/second to 35.5 +/- 9.3 cm/second (p<0.01). Physical exercise overrules the decrease in CBFV during hyperoxia and leads to even higher CBFV-increases with increasing pO2. A tendency towards CO2 retainment with elevated PetCOz may be causative and thus heighten the risk of oxygen-induced neurotoxicity.
- Open Access
- 18 September 2012
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 109 (6) , 907-910
N-terminal prohormone of brain natriuretic peptide: a useful tool for the detection of acute pulmonary artery embolism in post-surgical patients
Acute pulmonary embolism (APE) is an important clinical problem in patients after major surgery and often remains a difficult diagnosis because of unspecific clinical symptoms. Therefore, we investigated the role of N-terminal prohormone of brain natriuretic peptide (NT-proBNP) for the detection of APE. In 44 patients with suspected APE referred to the intensive care unit after major surgery, serum NT-proBNP, troponin-I, and D-dimers were measured according to the standard hospital protocol. To definitively confirm or exclude APE, all patients underwent an angiographic CT scan of the thorax. APE was confirmed in 28 and excluded in 16 patients by CT scan. NT-proBNP was significantly (P−1] compared with those without [283 (sd 327; range 13–1133) pg ml−1]. The sensitivity of the NT-proBNP screening was 93%, specificity 63%, positive predictive value 81%, and negative predictive value 83%. There were no significant (P = 0.96) differences in D-dimers between subjects with and without APE [confirmed APE: 511 (sd 207; range 83–750) μg litre−1; excluded APE: 509 (sd 170; range 230–750) μg litre−1]. Troponin-I levels were not elevated in 32% of the patients with APE. D-dimer levels are frequently elevated in post-surgical patients and not applicable for confirmation or exclusion of APE. In contrast, NT-proBNP appears to be a useful biomarker for APE diagnosis in the postoperative setting. In the case of NT-proBNP levels below the upper reference limit, haemodynamically relevant APE is unlikely. Troponin-I in contrast is not considered to be helpful.
- 18 September 2012
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 109 (6) , 907-910
Open AccessN-terminal prohormone of brain natriuretic peptide: a useful tool for the detection of acute pulmonary artery embolism in post-surgical patients
Acute pulmonary embolism (APE) is an important clinical problem in patients after major surgery and often remains a difficult diagnosis because of unspecific clinical symptoms. Therefore, we investigated the role of N-terminal prohormone of brain natriuretic peptide (NT-proBNP) for the detection of APE. In 44 patients with suspected APE referred to the intensive care unit after major surgery, serum NT-proBNP, troponin-I, and D-dimers were measured according to the standard hospital protocol. To definitively confirm or exclude APE, all patients underwent an angiographic CT scan of the thorax. APE was confirmed in 28 and excluded in 16 patients by CT scan. NT-proBNP was significantly (P−1] compared with those without [283 (sd 327; range 13–1133) pg ml−1]. The sensitivity of the NT-proBNP screening was 93%, specificity 63%, positive predictive value 81%, and negative predictive value 83%. There were no significant (P = 0.96) differences in D-dimers between subjects with and without APE [confirmed APE: 511 (sd 207; range 83–750) μg litre−1; excluded APE: 509 (sd 170; range 230–750) μg litre−1]. Troponin-I levels were not elevated in 32% of the patients with APE. D-dimer levels are frequently elevated in post-surgical patients and not applicable for confirmation or exclusion of APE. In contrast, NT-proBNP appears to be a useful biomarker for APE diagnosis in the postoperative setting. In the case of NT-proBNP levels below the upper reference limit, haemodynamically relevant APE is unlikely. Troponin-I in contrast is not considered to be helpful.
- 16 July 2012
- Published by BMJ in Emergency Medicine Journal
- Vol. 30 (7) , 579-582
Oxylator and SCUBA dive regulators: useful utilities for in-water resuscitation
Introduction In water resuscitation has been reported to enhance the outcome of drowning victims. Mouth-to-mouth ventilation during swimming is challenging. Therefore, the efficacy of ventilation utilities was evaluated. Methods Ventilation was assessed with the Oxylator ventilator, as well as the consecutive self-contained underwater breathing apparatus (SCUBA) regulators using an anaesthetic test lung: Poseidon Cyklon 5000, Poseidon XStream, Apeks TX 100, Spiro Arctic, Scubapro Air2 and Buddy AutoAir. Results Oxylator, Apeks TX 100, Arctic and Buddy AutoAir delivered reliable peak pressures and tidal volumes. In contrast, the ventilation parameters remarkably depended on duration and depth of pressing the purge button in Poseidon Cyklon 5000, Poseidon XStream and Scubapro Air2. Critical peak pressures occurred during ventilation with all these three regulators. Discussion The use of Poseidon Cyklon 5000, Poseidon XStream and Scubapro Air2 regulators is consequently not recommended for in-water ventilation. With the limitation that the devices were tested with a test lung and not in a human field study, Apeks TX 100, Spiro Arctic and Buddy AutoAir might be used for emergency ventilation and probably ease in-water resuscitation for the dive buddy of the victim. Professional rescue divers could be equipped with the Oxylator and an oxygen tank to achieve an early onset of efficient in-water ventilation in drowning victims.
- 16 July 2012
- Published by BMJ in Emergency Medicine Journal
- Vol. 30 (7) , 579-582
Oxylator and SCUBA dive regulators: useful utilities for in-water resuscitation
Introduction In water resuscitation has been reported to enhance the outcome of drowning victims. Mouth-to-mouth ventilation during swimming is challenging. Therefore, the efficacy of ventilation utilities was evaluated. Methods Ventilation was assessed with the Oxylator ventilator, as well as the consecutive self-contained underwater breathing apparatus (SCUBA) regulators using an anaesthetic test lung: Poseidon Cyklon 5000, Poseidon XStream, Apeks TX 100, Spiro Arctic, Scubapro Air2 and Buddy AutoAir. Results Oxylator, Apeks TX 100, Arctic and Buddy AutoAir delivered reliable peak pressures and tidal volumes. In contrast, the ventilation parameters remarkably depended on duration and depth of pressing the purge button in Poseidon Cyklon 5000, Poseidon XStream and Scubapro Air2. Critical peak pressures occurred during ventilation with all these three regulators. Discussion The use of Poseidon Cyklon 5000, Poseidon XStream and Scubapro Air2 regulators is consequently not recommended for in-water ventilation. With the limitation that the devices were tested with a test lung and not in a human field study, Apeks TX 100, Spiro Arctic and Buddy AutoAir might be used for emergency ventilation and probably ease in-water resuscitation for the dive buddy of the victim. Professional rescue divers could be equipped with the Oxylator and an oxygen tank to achieve an early onset of efficient in-water ventilation in drowning victims.
- 23 January 2012
- Published by Wiley in Acta Paediatrica
- Vol. 101 (5) , 472-478
Should children dive with self‐contained underwater breathing apparatus (SCUBA)?
Diving with self‐contained underwater breathing apparatus (SCUBA) has become a popular recreational activity in children and adolescents. This article provides an extensive review of the current literature.Conclusions: Medical contraindications to SCUBA diving for adults apply to children and adolescents, too, but must be adapted. Additional restrictions to the fitness to dive must apply to both, children and adolescents. Children should always be accompanied by a trained adult when diving.
- 23 January 2012
- Published by Wiley in Acta Paediatrica
- Vol. 101 (5) , 472-478
Should children dive with self‐contained underwater breathing apparatus (SCUBA)?
Diving with self‐contained underwater breathing apparatus (SCUBA) has become a popular recreational activity in children and adolescents. This article provides an extensive review of the current literature.Conclusions: Medical contraindications to SCUBA diving for adults apply to children and adolescents, too, but must be adapted. Additional restrictions to the fitness to dive must apply to both, children and adolescents. Children should always be accompanied by a trained adult when diving.
- 30 July 2010
- Published by Georg Thieme Verlag KG in International Journal of Sports Medicine
- Vol. 31 (10) , 724-730
Pulmonary Function in Children After Open Water SCUBA Dives
An increasing number of children and adolescents is diving with Self-Contained Underwater Breathing Apparatus (SCUBA). SCUBA diving is associated with health risks such as pulmonary barotrauma, especially in children and in individuals with airflow limitation. As no data has been published on the effects of open-water diving on pulmonary function in children, the objective of this study was to evaluate the effects of SCUBA dives on airflow in children. 16 healthy children aged 10–13 years underwent spirometry and a cycle-exercise challenge while breathing cold air. They subsequently performed dives to 1-m and 8-m depth in random order. Pulmonary function was measured before and after the exercise challenge and the dives. There were statistically significant decreases in FEV1, FVC, FEV1/FVC, MEF25 and MEF50 after the cold-air exercise challenge and the dives. Changes in lung function following the exercise challenge did not predict the responses to SCUBA diving. In 3 children the post-dive decrements in FEV1 exceeded 10%. These children had a lower body weight and BMI percentile. SCUBA diving in healthy children may be associated with relevant airflow limitation. A low body mass might contribute to diving-associated bronchoconstriction. In the majority of subjects, no clinically relevant airway obstruction could be observed.
- 30 July 2010
- Published by Georg Thieme Verlag KG in International Journal of Sports Medicine
- Vol. 31 (10) , 724-730
Pulmonary Function in Children After Open Water SCUBA Dives
An increasing number of children and adolescents is diving with Self-Contained Underwater Breathing Apparatus (SCUBA). SCUBA diving is associated with health risks such as pulmonary barotrauma, especially in children and in individuals with airflow limitation. As no data has been published on the effects of open-water diving on pulmonary function in children, the objective of this study was to evaluate the effects of SCUBA dives on airflow in children. 16 healthy children aged 10–13 years underwent spirometry and a cycle-exercise challenge while breathing cold air. They subsequently performed dives to 1-m and 8-m depth in random order. Pulmonary function was measured before and after the exercise challenge and the dives. There were statistically significant decreases in FEV1, FVC, FEV1/FVC, MEF25 and MEF50 after the cold-air exercise challenge and the dives. Changes in lung function following the exercise challenge did not predict the responses to SCUBA diving. In 3 children the post-dive decrements in FEV1 exceeded 10%. These children had a lower body weight and BMI percentile. SCUBA diving in healthy children may be associated with relevant airflow limitation. A low body mass might contribute to diving-associated bronchoconstriction. In the majority of subjects, no clinically relevant airway obstruction could be observed.