Manabu Sato
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Manabu Sato has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
Izumi Nishidate
Tokyo University of Agriculture and Technology
11 shared publications- Izumi Nishidate
Graduate School of Bio-Applications and Systems Engineering, Tokyo University of Agriculture and Technology, Tokyo, Japan
6 shared publications - Shunichi Sato
National Defense Medical College Research Institute, Division of Bioinformation and Therapeutic Systems, Saitama, Japan
5 shared publications Junpei Masuta
Yamagata University
4 shared publicationsNaohiro Tanno
The authors are with Yamagata University, 4-3-16 Johnan, Yonezawa 992-8510, Japan
4 shared publications- Satoko Kawauchi
National Defense Medical College (Japan)
4 shared publications
Latest Publications
- 22 August 2022
- Published by Springer Nature in Optical Review
- Vol. 29 (4) , 1
Preface
- 20 July 2021
- Published by Optica Publishing Group in Applied Optics
- Vol. 60 (21) , 6290-6301
Improvement of frequency resolution using a sub-bin structure in the discrete Fourier transform
To improve frequency resolution, assignments of sub-bins within the bin interval of the conventional discrete Fourier transform are proposed by decreasing the number of sampled data. The simulated and experimental results of the basic sub-bin spectrum characteristics are presented. Using a signal oscillator, digital oscilloscope, and PC, the sub-bin line spectrum between two conventional bins is measured, and nine line spectra of sub-bins corresponding to the simulated results are measured. The linearity of the sub-bin spectrum intensity for amplitudes of 0.001–10 V of the input signal is also measured. The Doppler signals from the optical interferometer using a He–Ne laser are measured using a mixer to tune the frequency. A sub-bin spectrum of 104.89 kHz between two bin frequencies of 104.49 and 105.47 kHz is measured using 256 data points at a sampling frequency of 250 kHz and an acquisition time of 1.024 ms. The precision of displacement for the acquisition time is improved by one order to 32 nm for a full displacement of 2.342 µm. The sub-bins, as a composition of bin structure, are applicable to various fields.
- 20 July 2021
- Published by Optica Publishing Group in Applied Optics
- Vol. 60 (21) , 6290-6301
Improvement of frequency resolution using a sub-bin structure in the discrete Fourier transform
To improve frequency resolution, assignments of sub-bins within the bin interval of the conventional discrete Fourier transform are proposed by decreasing the number of sampled data. The simulated and experimental results of the basic sub-bin spectrum characteristics are presented. Using a signal oscillator, digital oscilloscope, and PC, the sub-bin line spectrum between two conventional bins is measured, and nine line spectra of sub-bins corresponding to the simulated results are measured. The linearity of the sub-bin spectrum intensity for amplitudes of 0.001–10 V of the input signal is also measured. The Doppler signals from the optical interferometer using a He–Ne laser are measured using a mixer to tune the frequency. A sub-bin spectrum of 104.89 kHz between two bin frequencies of 104.49 and 105.47 kHz is measured using 256 data points at a sampling frequency of 250 kHz and an acquisition time of 1.024 ms. The precision of displacement for the acquisition time is improved by one order to 32 nm for a full displacement of 2.342 µm. The sub-bins, as a composition of bin structure, are applicable to various fields.
- 20 November 2020
- Published by Optica Publishing Group in Applied Optics
- Vol. 59 (33) , 10512-10522
Differential phase imaging in full-field optical coherence microscopy using a short multimode fiber probe
We demonstrate phase imaging that reduces the common phase noise in full-field optical coherence microscopy using a short multimode fiber (SMMF) probe. Using a cover glass, phase images of the SMMF and sample surfaces were measured simultaneously. Subtracting the phase of the SMMF surface as a reference, the phase drifts in the sample region are reduced. The axial and lateral resolutions were 2.3 µm and < 4.4 µ m , respectively. The standard deviation of the time variation in the phase decreased from 14.3 deg to 9.2 deg and was reduced by 64% when in contact with the polymer film at the SMMF. In quantitative evaluations, the measured phases closely correspond to the phases changed by a piezoelectric device.
- 20 November 2020
- Published by Optica Publishing Group in Applied Optics
- Vol. 59 (33) , 10512-10522
Differential phase imaging in full-field optical coherence microscopy using a short multimode fiber probe
We demonstrate phase imaging that reduces the common phase noise in full-field optical coherence microscopy using a short multimode fiber (SMMF) probe. Using a cover glass, phase images of the SMMF and sample surfaces were measured simultaneously. Subtracting the phase of the SMMF surface as a reference, the phase drifts in the sample region are reduced. The axial and lateral resolutions were 2.3 µm and < 4.4 µ m , respectively. The standard deviation of the time variation in the phase decreased from 14.3 deg to 9.2 deg and was reduced by 64% when in contact with the polymer film at the SMMF. In quantitative evaluations, the measured phases closely correspond to the phases changed by a piezoelectric device.
- Open Access
- 15 April 2020
- Published by Japan Society for Laser Surgery and Medicine in THE JOURNAL OF JAPAN SOCIETY FOR LASER SURGERY AND MEDICINE
- Vol. 41 (1) , 9-17
Sectional Imaging of in vivo Rat Brain Using Short Multimode Fiber Probe
直径125 μm,長さ7.4 mmの光通信用ファイバーをOCM(optical coherence microscopy)のイメージプローブに用いて,in vivoラット脳の断層画像を測定した.深さ分解能,横方向分解能は,それぞれ2.14 μm,2.3 μmである.SMMFを最大4 mmまで挿入して視野直径47 μm,SMMF端面から深さ147 μmまで測定を行った.深さ20~90 μmで,粒状や5 μm~10 μmの繊維状の形態情報が得られた.三次元の繊維形態が51.5 μm × 51.5 μm × 深さ104 μmの領域で確認され,さらに,内部の14.9 μm × 12.4 μm × 深さ8.1 μmの領域でも,繊維の接続や屈曲状態が確認された.また,OCM画像信号の積算値が灰白質の底部で最大値を取っており,神経線維の断層画像が測定された.今後,再生医療やがん診断,また腹腔鏡ロボットなどの分野で応用が考えられる.
- 15 April 2020
- Published by Japan Society for Laser Surgery and Medicine in THE JOURNAL OF JAPAN SOCIETY FOR LASER SURGERY AND MEDICINE
- Vol. 41 (1) , 9-17
Open AccessSectional Imaging of in vivo Rat Brain Using Short Multimode Fiber Probe
直径125 μm,長さ7.4 mmの光通信用ファイバーをOCM(optical coherence microscopy)のイメージプローブに用いて,in vivoラット脳の断層画像を測定した.深さ分解能,横方向分解能は,それぞれ2.14 μm,2.3 μmである.SMMFを最大4 mmまで挿入して視野直径47 μm,SMMF端面から深さ147 μmまで測定を行った.深さ20~90 μmで,粒状や5 μm~10 μmの繊維状の形態情報が得られた.三次元の繊維形態が51.5 μm × 51.5 μm × 深さ104 μmの領域で確認され,さらに,内部の14.9 μm × 12.4 μm × 深さ8.1 μmの領域でも,繊維の接続や屈曲状態が確認された.また,OCM画像信号の積算値が灰白質の底部で最大値を取っており,神経線維の断層画像が測定された.今後,再生医療やがん診断,また腹腔鏡ロボットなどの分野で応用が考えられる.
- Open Access
- 9 January 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (2) , 216
In Vivo Rat Brain Imaging through Full-Field Optical Coherence Microscopy Using an Ultrathin Short Multimode Fiber Probe
We demonstrate full-field optical coherence microscopy (OCM) using an ultrathin forward-imaging short multimode fiber (SMMF) probe with a core diameter of 50 μm, outer diameter of 125 μm, and length of 7.4 mm, which is a typical graded-index multimode fiber used for optical communications. The axial and lateral resolutions were measured to be 2.14 μm and 2.3 μm, respectively. By inserting the SMMF 4 mm into the cortex of an in vivo rat brain, scanning was performed to a depth of 147 μm from the SMMF facet with a field of view of 47 μm. Three-dimensional (3D) OCM images were obtained at depths ranging from approximately 20 μm to 90 μm. Based on the morphological information of the resliced 3D images and the dependence of the integration of the OCM image signal on the insertion length, the obtained 3D information of nerve fibers has been presented.
- 9 January 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (2) , 216
Open AccessIn Vivo Rat Brain Imaging through Full-Field Optical Coherence Microscopy Using an Ultrathin Short Multimode Fiber Probe
We demonstrate full-field optical coherence microscopy (OCM) using an ultrathin forward-imaging short multimode fiber (SMMF) probe with a core diameter of 50 μm, outer diameter of 125 μm, and length of 7.4 mm, which is a typical graded-index multimode fiber used for optical communications. The axial and lateral resolutions were measured to be 2.14 μm and 2.3 μm, respectively. By inserting the SMMF 4 mm into the cortex of an in vivo rat brain, scanning was performed to a depth of 147 μm from the SMMF facet with a field of view of 47 μm. Three-dimensional (3D) OCM images were obtained at depths ranging from approximately 20 μm to 90 μm. Based on the morphological information of the resliced 3D images and the dependence of the integration of the OCM image signal on the insertion length, the obtained 3D information of nerve fibers has been presented.
- 3 December 2018
- Published by Optica Publishing Group in Applied Optics
- Vol. 57 (35) , 10083-10091
Depolarization characteristics of spatial modes in imaging probe using short multimode fiber
Optical coherence tomography is one of the standard imaging modalities at present, widely used in the medical and biological fields to obtain three-dimensional (3D) images with high spatial resolution. However, the depth up to which the 3D images can be directly obtained is limited to within 3 mm. Therefore, the suitability of many kinds of catheters and needles has been considered for minimally invasive imaging. We have examined the utility of a short multimode fiber (SMMF) using graded index optical fibers for minimal invasive imaging of deeper areas, up to 6–8 mm. The diameter and length of the SMMF are 125 μm and 6–8 mm, respectively. In the core of the SMMF, scattering and multirefraction occur due to small variations in the refractive index to generate deformations and depolarization of images. In order to investigate the depolarization characteristics, the images reflected at the facet of the SMMF were measured by changing the angle of the polarizer, using an LED as the light source. The reflection image almost corresponds to that obtained with combined linearly polarized modes with the ratio of equal to . Comparing the measured results with simulations in the simple model, the depolarization ratio was estimated at 0.7 in the core. The degrees of polarization were measured to be 0.15 around the center and increased to 0.90 at the periphery.- 3 December 2018
- Published by Optica Publishing Group in Applied Optics
- Vol. 57 (35) , 10083-10091
Depolarization characteristics of spatial modes in imaging probe using short multimode fiber
Optical coherence tomography is one of the standard imaging modalities at present, widely used in the medical and biological fields to obtain three-dimensional (3D) images with high spatial resolution. However, the depth up to which the 3D images can be directly obtained is limited to within 3 mm. Therefore, the suitability of many kinds of catheters and needles has been considered for minimally invasive imaging. We have examined the utility of a short multimode fiber (SMMF) using graded index optical fibers for minimal invasive imaging of deeper areas, up to 6–8 mm. The diameter and length of the SMMF are 125 μm and 6–8 mm, respectively. In the core of the SMMF, scattering and multirefraction occur due to small variations in the refractive index to generate deformations and depolarization of images. In order to investigate the depolarization characteristics, the images reflected at the facet of the SMMF were measured by changing the angle of the polarizer, using an LED as the light source. The reflection image almost corresponds to that obtained with combined linearly polarized modes with the ratio of equal to . Comparing the measured results with simulations in the simple model, the depolarization ratio was estimated at 0.7 in the core. The degrees of polarization were measured to be 0.15 around the center and increased to 0.90 at the periphery.- 5 November 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10815, 108150S
RGB camera-based functional imaging of in vivo biological tissues
We investigated a rapid imaging method to monitor the spatial distribution of total hemoglobin concentration (CHbT), the tissue oxygen saturation (StO2), and the scattering power b in the expression of musp=a(lambda)^-b as the scattering parameters in cerebral cortex using a digital red-green-blue camera. In the method, Monte Carlo simulation (MCS) for light transport in brain tissue is used to specify a relation among the RGB-values and the concentration of oxygenated hemoglobin (CHbO), that of deoxygenated hemoglobin (CHbR), and the scattering power b. The results in this study indicate potential of the method to evaluate the physiology and loss of tissue viability in biological tissues.
- 5 November 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10815, 108150S
RGB camera-based functional imaging of in vivo biological tissues
We investigated a rapid imaging method to monitor the spatial distribution of total hemoglobin concentration (CHbT), the tissue oxygen saturation (StO2), and the scattering power b in the expression of musp=a(lambda)^-b as the scattering parameters in cerebral cortex using a digital red-green-blue camera. In the method, Monte Carlo simulation (MCS) for light transport in brain tissue is used to specify a relation among the RGB-values and the concentration of oxygenated hemoglobin (CHbO), that of deoxygenated hemoglobin (CHbR), and the scattering power b. The results in this study indicate potential of the method to evaluate the physiology and loss of tissue viability in biological tissues.
- Open Access
- 6 February 2018
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 19 (2) , 491
In Vivo Evaluation of Cerebral Hemodynamics and Tissue Morphology in Rats during Changing Fraction of Inspired Oxygen Based on Spectrocolorimetric Imaging Technique
During surgical treatment for cerebrovascular diseases, cortical hemodynamics are often controlled by bypass graft surgery, temporary occlusion of arteries, and surgical removal of veins. Since the brain is vulnerable to hypoxemia and ischemia, interruption of cerebral blood flow reduces the oxygen supply to tissues and induces irreversible damage to cells and tissues. Monitoring of cerebral hemodynamics and alteration of cellular structure during neurosurgery is thus crucial. Sequential recordings of red-green-blue (RGB) images of in vivo exposed rat brains were made during hyperoxia, normoxia, hypoxia, and anoxia. Monte Carlo simulation of light transport in brain tissue was used to specify relationships among RGB-values and oxygenated hemoglobin concentration (CHbO), deoxygenated hemoglobin concentration (CHbR), total hemoglobin concentration (CHbT), hemoglobin oxygen saturation (StO2), and scattering power b. Temporal courses of CHbO, CHbR, CHbT, and StO2 indicated physiological responses to reduced oxygen delivery to cerebral tissue. A rapid decrease in light scattering power b was observed after respiratory arrest, similar to the negative deflection of the extracellular direct current (DC) potential in so-called anoxic depolarization. These results suggest the potential of this method for evaluating pathophysiological conditions and loss of tissue viability.
- 6 February 2018
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 19 (2) , 491
Open AccessIn Vivo Evaluation of Cerebral Hemodynamics and Tissue Morphology in Rats during Changing Fraction of Inspired Oxygen Based on Spectrocolorimetric Imaging Technique
During surgical treatment for cerebrovascular diseases, cortical hemodynamics are often controlled by bypass graft surgery, temporary occlusion of arteries, and surgical removal of veins. Since the brain is vulnerable to hypoxemia and ischemia, interruption of cerebral blood flow reduces the oxygen supply to tissues and induces irreversible damage to cells and tissues. Monitoring of cerebral hemodynamics and alteration of cellular structure during neurosurgery is thus crucial. Sequential recordings of red-green-blue (RGB) images of in vivo exposed rat brains were made during hyperoxia, normoxia, hypoxia, and anoxia. Monte Carlo simulation of light transport in brain tissue was used to specify relationships among RGB-values and oxygenated hemoglobin concentration (CHbO), deoxygenated hemoglobin concentration (CHbR), total hemoglobin concentration (CHbT), hemoglobin oxygen saturation (StO2), and scattering power b. Temporal courses of CHbO, CHbR, CHbT, and StO2 indicated physiological responses to reduced oxygen delivery to cerebral tissue. A rapid decrease in light scattering power b was observed after respiratory arrest, similar to the negative deflection of the extracellular direct current (DC) potential in so-called anoxic depolarization. These results suggest the potential of this method for evaluating pathophysiological conditions and loss of tissue viability.
- 18 April 2017
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10251, 102510
In vivo imaging of spontaneous low-frequency oscillations in cerebral hemodynamics with a digital red-green-blue camera
Nervous system relies on a continuous and adequate supply of blood flow, bringing the nutrients that it needs and removing the waste products of metabolism. Failure of these mechanisms is found in a number of devastating cerebral diseases, including stroke, vascular dementia, brain injury and trauma. Vasomotion which is the spontaneous low-frequency oscillation derived by the contraction and relaxation of arterioles and appears to be an intrinsic property of the cerebral vasculature, is important for monitoring the cerebral flow, tissue metabolism and health status of brain tissue. In the present study, we investigated a method to visualize the spontaneous low-frequency oscillation of cerebral blood volume based on the sequential RGB images of exposed brain. © (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
- 18 April 2017
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10251, 102510
In vivo imaging of spontaneous low-frequency oscillations in cerebral hemodynamics with a digital red-green-blue camera
Nervous system relies on a continuous and adequate supply of blood flow, bringing the nutrients that it needs and removing the waste products of metabolism. Failure of these mechanisms is found in a number of devastating cerebral diseases, including stroke, vascular dementia, brain injury and trauma. Vasomotion which is the spontaneous low-frequency oscillation derived by the contraction and relaxation of arterioles and appears to be an intrinsic property of the cerebral vasculature, is important for monitoring the cerebral flow, tissue metabolism and health status of brain tissue. In the present study, we investigated a method to visualize the spontaneous low-frequency oscillation of cerebral blood volume based on the sequential RGB images of exposed brain. © (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
- 8 February 2017
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10050, 100500
In vivo imaging of tissue scattering parameter and cerebral hemodynamics in rat brain with a digital red-green-blue camera
We propose a rapid imaging method to monitor the spatial distribution of total hemoglobin concentration (CHbT), the tissue oxygen saturation, and the scattering power b in the expression of μs’=aλ-b as the scattering parameters in cerebral cortex using a digital red-green-blue camera. In the method, the RGB-values are converted into the tristimulus values in CIEXYZ color space which is compatible with the common RGB working spaces. Monte Carlo simulation (MCS) for light transport in tissue is used to specify a relation among the tristimulus XYZ-values and the concentration of oxygenated hemoglobin, that of deoxygenated hemoglobin, and the scattering power b. In the present study, we performed sequential recordings of RGB images of in vivo exposed rat brain during the cortical spreading depolarization evoked by the topical application of KCl. Changes in the total hemoglobin concentration and the tissue oxygen saturation imply the temporary change in cerebral blood flow during CSD. Decrease in the scattering power b was observed before the profound increase in the total hemoglobin concentration, which is indicative of the reversible morphological changes in brain tissue during CSD. The results in this study indicate potential of the method to evaluate the pathophysiological conditions in brain tissue with a digital red-green-blue camera. © (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
- 8 February 2017
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10050, 100500
In vivo imaging of tissue scattering parameter and cerebral hemodynamics in rat brain with a digital red-green-blue camera
We propose a rapid imaging method to monitor the spatial distribution of total hemoglobin concentration (CHbT), the tissue oxygen saturation, and the scattering power b in the expression of μs’=aλ-b as the scattering parameters in cerebral cortex using a digital red-green-blue camera. In the method, the RGB-values are converted into the tristimulus values in CIEXYZ color space which is compatible with the common RGB working spaces. Monte Carlo simulation (MCS) for light transport in tissue is used to specify a relation among the tristimulus XYZ-values and the concentration of oxygenated hemoglobin, that of deoxygenated hemoglobin, and the scattering power b. In the present study, we performed sequential recordings of RGB images of in vivo exposed rat brain during the cortical spreading depolarization evoked by the topical application of KCl. Changes in the total hemoglobin concentration and the tissue oxygen saturation imply the temporary change in cerebral blood flow during CSD. Decrease in the scattering power b was observed before the profound increase in the total hemoglobin concentration, which is indicative of the reversible morphological changes in brain tissue during CSD. The results in this study indicate potential of the method to evaluate the pathophysiological conditions in brain tissue with a digital red-green-blue camera. © (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.