MKMyung K. Kim

Myung K. Kim

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Myung K. Kim has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Top Cited Papers

    Principles and techniques of digital holographic microscopy

    by Myung K. Kim

    Digital holography is an emerging field of new paradigm in general imaging applications. We present a review of a subset of the research and development activities in digital holography, with emphasis on microscopy techniques and applications. First, the basic results from the general theory of holography, based on the scalar diffraction theory, are summarized, and a general description of the digital holographic microscopy process is given, including quantitative phase microscopy. Several numerical diffraction methods are described and compared, and a number of representative configurations used in digital holography are described, including off-axis Fresnel, Fourier, image plane, in-line, Gabor, and phase-shifting digital holographies. Then we survey numerical techniques that give rise to unique capabilities of digital holography, including suppression of dc and twin image terms, pixel resolution control, optical phase unwrapping, aberration compensation, and others. A survey is also given of representative application areas, including biomedical microscopy, particle field holography, micrometrology, and holographic tomography, as well as some of the special techniques, such as holography of total internal reflection, optical scanning holography, digital interference holography, and heterodyne holography. The review is intended for students and new researchers interested in developing new techniques and exploring new applications of digital holography.


  • Open Access

    Movies of cellular and sub-cellular motion by digital holographic microscopy

    by Christopher J Mann, Lingfeng Yu, Myung K Kim

    Background: Many biological specimens, such as living cells and their intracellular components, often exhibit very little amplitude contrast, making it difficult for conventional bright field microscopes to distinguish them from their surroundings. To overcome this problem phase contrast techniques such as Zernike, Normarsky and dark-field microscopies have been developed to improve specimen visibility without chemically or physically altering them by the process of staining. These techniques have proven to be invaluable tools for studying living cells and furthering scientific understanding of fundamental cellular processes such as mitosis. However a drawback of these techniques is that direct quantitative phase imaging is not possible. Quantitative phase imaging is important because it enables determination of either the refractive index or optical thickness variations from the measured optical path length with sub-wavelength accuracy. Digital holography is an emergent phase contrast technique that offers an excellent approach in obtaining both qualitative and quantitative phase information from the hologram. A CCD camera is used to record a hologram onto a computer and numerical methods are subsequently applied to reconstruct the hologram to enable direct access to both phase and amplitude information. Another attractive feature of digital holography is the ability to focus on multiple focal planes from a single hologram, emulating the focusing control of a conventional microscope. Methods: A modified Mach-Zender off-axis setup in transmission is used to record and reconstruct a number of holographic amplitude and phase images of cellular and sub-cellular features. Results: Both cellular and sub-cellular features are imaged with sub-micron, diffraction-limited resolution. Movies of holographic amplitude and phase images of living microbes and cells are created from a series of holograms and reconstructed with numerically adjustable focus, so that the moving object can be accurately tracked with a reconstruction rate of 300ms for each hologram. The holographic movies show paramecium swimming among other microbes as well as displaying some of their intracellular processes. A time lapse movie is also shown for fibroblast cells in the process of migration. Conclusion: Digital holography and movies of digital holography are seen to be useful new tools for visualization of dynamic processes in biological microscopy. Phase imaging digital holography is a promising technique in terms of the lack of coherent noise and the precision with which the optical thickness of a sample can be profiled, which can lead to images with an axial resolution of a few nanometres.


  • Digital holographic microscopy with dual-wavelength phase unwrapping

    by Daniel Parshall, Myung K. Kim

    We apply the techniques of digital holography to obtain microscopic three-dimensional images of biological cells. The optical system is capable of microscopic holography with diffraction-limited resolution by projecting a magnified image of a microscopic hologram plane onto a CCD plane. Two-wavelength phase-imaging digital holography is applied to produce unwrapped phase images of biological cells. The method of three-wavelength phase imaging is proposed to extend the axial range and reduce the effect of phase noise. These results demonstrate the effectiveness of digital holography in high-resolution biological microscopy.


  • Full-color three-dimensional microscopy using white-light interference on a color camera

    by Lingfeng Yu, Myung K. Kim

    We present experimental demonstration of a novel full-color three-dimensional microscopy method. A white-light high-brightness LED illuminates a Michelson interferometer. A color CCD camera records the color image of an object in superposition with the reference beam. The short-coherence interferometric process is applied to each of the three color channels to extract tomographic contour images of the object. The set of three images are recombined as RGB channels to construct a color tomographic image of a section of the object. The reference mirror is scanned over a range of axial distances to construct a three-dimensional tomographic image of the object with full natural color representation. The technique is applied to imaging of artificial color objects as well as colorful biological objects with about 10 um axial resolution, about 100 ~ 200 um penetration depth, and 50 ~ 60 db dynamic range. In contrast to most existing three-dimensional microscopy methods, the present technique allows monitoring of tissue structures close to its natural color, which may be useful in various physiological and pathological applications.

  • Wavelength scanning digital interference holography for variable tomographic scanning

    by Lingfeng Yu, Myung K. Kim

    Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.


  • Microscopic three-dimensional imaging by digital interference holography

    by Aaron Dakoff, James Gass, Myung K. Kim

    Digital interference holography (DIH) is being developed as a novel method of microscopic 3-D imaging. A number of holographic fields are numerically calculated from optically recorded holograms using a range of wavelengths. Numerical superposition of these fields results in a tomographic representation of the object with narrow axial resolution. We demonstrate the practicality of DIH in microscopic imaging with a set of preliminary experiments, yielding approximately 3 μm of lateral resolution and 10 μm of axial resolution, using a simple optical setup and straightforward numerical algorithms. © 2003 SPIE and IS&T.


  • Top Cited Papers

    Phase imaging without 2π ambiguity by multiwavelength digital holography

    by J. Gass, A. Dakoff, M. K. Kim

    We present a phase-imaging method with an axial range that can in principle be arbitrarily large compared to the wavelength and does not involve the usual phase unwrapping by detection of phase discontinuity. The method consists of the generation and combination of two phase maps in a digital holography system by use of two separate wavelengths. For example, we reconstructed the surface of a spherical mirror with ∼10‐nm axial resolution and an axial range of ∼3 µm.