Pierre E. Wallemacq
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Pierre E. Wallemacq has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
Roger Vanbinst
Clinical Chemistry Department, UHSL
3 shared publicationsA Hassoun
2 shared publicationsAlexandre Hassoun
Clin. Chem., Kidney Transplant., and Hepatic Transplant., University Hosp. St Luc, Univ. of Louvain, 10 Hippocrate Ave., B-1200 Brussels, Belgium
2 shared publicationsJ B Otte
2 shared publicationsTeresinha Leal
Clin. Chem., Kidney Transplant., and Hepatic Transplant., University Hosp. St Luc, Univ. of Louvain, 10 Hippocrate Ave., B-1200 Brussels, Belgium
2 shared publicationsA Ferrant
1 shared publication
Latest Publications
- Open Access
- 25 October 2006
- Published by Springer Nature in Respiratory Research
- Vol. 7 (1) , 134
Azithromycin reduces spontaneous and induced inflammation in ΔF508 cystic fibrosis mice
Inflammation plays a critical role in lung disease development and progression in cystic fibrosis. Azithromycin is used for the treatment of cystic fibrosis lung disease, although its mechanisms of action are poorly understood. We tested the hypothesis that azithromycin modulates lung inflammation in cystic fibrosis mice. We monitored cellular and molecular inflammatory markers in lungs of cystic fibrosis mutant mice homozygous for the ΔF508 mutation and their littermate controls, either in baseline conditions or after induction of acute inflammation by intratracheal instillation of lipopolysaccharide from Pseudomonas aeruginosa, which would be independent of interactions of bacteria with epithelial cells. The effect of azithromycin pretreatment (10 mg/kg/day) given by oral administration for 4 weeks was evaluated. In naive cystic fibrosis mice, a spontaneous lung inflammation was observed, characterized by macrophage and neutrophil infiltration, and increased intra-luminal content of the pro-inflammatory cytokine macrophage inflammatory protein-2. After induced inflammation, cystic fibrosis mice combined exaggerated cellular infiltration and lower anti-inflammatory interleukin-10 production. In cystic fibrosis mice, azithromycin attenuated cellular infiltration in both baseline and induced inflammatory condition, and inhibited cytokine (tumor necrosis factor-α and macrophage inflammatory protein-2) release in lipopolysaccharide-induced inflammation. Our findings further support the concept that inflammatory responses are upregulated in cystic fibrosis. Azithromycin reduces some lung inflammation outcome measures in cystic fibrosis mice. We postulate that some of the benefits of azithromycin treatment in cystic fibrosis patients are due to modulation of lung inflammation.
- 25 October 2006
- Published by Springer Nature in Respiratory Research
- Vol. 7 (1) , 134
Open AccessAzithromycin reduces spontaneous and induced inflammation in ΔF508 cystic fibrosis mice
Inflammation plays a critical role in lung disease development and progression in cystic fibrosis. Azithromycin is used for the treatment of cystic fibrosis lung disease, although its mechanisms of action are poorly understood. We tested the hypothesis that azithromycin modulates lung inflammation in cystic fibrosis mice. We monitored cellular and molecular inflammatory markers in lungs of cystic fibrosis mutant mice homozygous for the ΔF508 mutation and their littermate controls, either in baseline conditions or after induction of acute inflammation by intratracheal instillation of lipopolysaccharide from Pseudomonas aeruginosa, which would be independent of interactions of bacteria with epithelial cells. The effect of azithromycin pretreatment (10 mg/kg/day) given by oral administration for 4 weeks was evaluated. In naive cystic fibrosis mice, a spontaneous lung inflammation was observed, characterized by macrophage and neutrophil infiltration, and increased intra-luminal content of the pro-inflammatory cytokine macrophage inflammatory protein-2. After induced inflammation, cystic fibrosis mice combined exaggerated cellular infiltration and lower anti-inflammatory interleukin-10 production. In cystic fibrosis mice, azithromycin attenuated cellular infiltration in both baseline and induced inflammatory condition, and inhibited cytokine (tumor necrosis factor-α and macrophage inflammatory protein-2) release in lipopolysaccharide-induced inflammation. Our findings further support the concept that inflammatory responses are upregulated in cystic fibrosis. Azithromycin reduces some lung inflammation outcome measures in cystic fibrosis mice. We postulate that some of the benefits of azithromycin treatment in cystic fibrosis patients are due to modulation of lung inflammation.
- 15 March 2006
- Published by Oxford University Press (OUP) in American Journal of Health-System Pharmacy
- Vol. 63 (6) , 547-556
Permeability of 13 different gloves to 13 cytotoxic agents under controlled dynamic conditions
Purpose. The permeability of 13 different gloves to 13 cytotoxic agents under controlled dynamic conditions is described.
- 15 March 2006
- Published by Oxford University Press (OUP) in American Journal of Health-System Pharmacy
- Vol. 63 (6) , 547-556
Permeability of 13 different gloves to 13 cytotoxic agents under controlled dynamic conditions
Purpose. The permeability of 13 different gloves to 13 cytotoxic agents under controlled dynamic conditions is described.
- 1 June 2004
- Published by Wolters Kluwer Health in Therapeutic Drug Monitoring
- Vol. 26 (3) , 258-262
Plasma and Tissue Determination of 4-Methylpyrazole for Pharmacokinetic Analysis in Acute Adult and Pediatric Methanol/Ethylene Glycol Poisoning
Methanol and ethylene glycol poisoning may result in severe intoxication. The inhibition of alcohol dehydrogenase by ethanol or 4-methylpyrazole (4-MP, fomepizole) is fundamental to their treatment. 4-MP presents several advantages over ethanol therapy and has been recently approved as a specific antidote for both intoxications. The authors have developed a simple gas chromatographic method to determine blood and tissue 4-MP concentrations. This method has been validated for its reproducibility (between-day CV < 6.3%), sensitivity (LOD 0.2 microg/mL), and linearity. It has been used in 4 adult patients intoxicated by methanol and 1 child accidentally intoxicated by ethylene glycol. 4-MP was used for each patient, and its blood levels were monitored every 4 hours over 2-3 days for pharmacokinetics purposes. In the population studied, after repeated administration of 10 mg/kg fomepizole, plasma 4-MP concentrations ranged from 1.4 to 21.6 microg/mL, always above the active level of 0.8 microg/mL. The mean peak concentration observed in the 4 adult patients was 18.5 +/- 2.6 microg/mL and in the child was 18.9 +/- 2.2 microg/mL. Even though 4-MP is characterized by a dose-dependent kinetic profile, under our conditions of dosage and blood sampling, its elimination better fitted a first-order kinetic model. At steady state and without any concomitant therapies, the mean apparent elimination half-life was 14.5 +/- 3 hours. Elimination seemed faster in the child. A trend toward a progessive enhancement of the 4-MP elimination rate is suggested in the pediatric case, with the duration of the treatment resulting in a t(1/2) below 5 hours after 48 hours. One patient died, and samples of blood and hepatic tissue were removed simultaneously during autopsy for 4-MP analysis. Interestingly, when the plasma concentration was subtherapeutic (<1 microg/mL) the tissue concentration observed was still significant with 12 microg/g, supporting an intermittent scheme of administration.
- 1 June 2004
- Published by Wolters Kluwer Health in Therapeutic Drug Monitoring
- Vol. 26 (3) , 258-262
Plasma and Tissue Determination of 4-Methylpyrazole for Pharmacokinetic Analysis in Acute Adult and Pediatric Methanol/Ethylene Glycol Poisoning
Methanol and ethylene glycol poisoning may result in severe intoxication. The inhibition of alcohol dehydrogenase by ethanol or 4-methylpyrazole (4-MP, fomepizole) is fundamental to their treatment. 4-MP presents several advantages over ethanol therapy and has been recently approved as a specific antidote for both intoxications. The authors have developed a simple gas chromatographic method to determine blood and tissue 4-MP concentrations. This method has been validated for its reproducibility (between-day CV < 6.3%), sensitivity (LOD 0.2 microg/mL), and linearity. It has been used in 4 adult patients intoxicated by methanol and 1 child accidentally intoxicated by ethylene glycol. 4-MP was used for each patient, and its blood levels were monitored every 4 hours over 2-3 days for pharmacokinetics purposes. In the population studied, after repeated administration of 10 mg/kg fomepizole, plasma 4-MP concentrations ranged from 1.4 to 21.6 microg/mL, always above the active level of 0.8 microg/mL. The mean peak concentration observed in the 4 adult patients was 18.5 +/- 2.6 microg/mL and in the child was 18.9 +/- 2.2 microg/mL. Even though 4-MP is characterized by a dose-dependent kinetic profile, under our conditions of dosage and blood sampling, its elimination better fitted a first-order kinetic model. At steady state and without any concomitant therapies, the mean apparent elimination half-life was 14.5 +/- 3 hours. Elimination seemed faster in the child. A trend toward a progessive enhancement of the 4-MP elimination rate is suggested in the pediatric case, with the duration of the treatment resulting in a t(1/2) below 5 hours after 48 hours. One patient died, and samples of blood and hepatic tissue were removed simultaneously during autopsy for 4-MP analysis. Interestingly, when the plasma concentration was subtherapeutic (<1 microg/mL) the tissue concentration observed was still significant with 12 microg/g, supporting an intermittent scheme of administration.
- 1 January 2004
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 42 (11) , 1204-11
Therapeutic monitoring of immunosuppressant drugs. Where are we?
The emergence of specific immunosuppressive drugs (cyclosporine, tacrolimus, mycophenolate mofetil and sirolimus) during the last two decades has contributed dramatically to the success of organ transplantation. However, optimum balance between therapeutic efficacy and the occurrence of side effects has been a real challenge for physicians, mainly due to inter- and intra-patient variability arising from pharmacokinetic, pharmacogenetic and pharmacodynamic individual properties. Therapeutic drug monitoring, defined as the measurement and interpretation of concentrations of these drugs in biological fluids, with as a final objective the prediction of organ responses, became an integral part of transplant protocols. New analytical techniques became available with different performances in terms of specificity and sensitivity. In addition, there has been progress in understanding the mechanisms of action of these drugs that have implications for the development of better monitoring strategies and for their coprescription. The purpose of this review is to examine the current strategies in use for the therapeutic drug monitoring of immunosuppressant drugs and to discuss some of the factors that impinge on the monitoring of these drugs.
- 1 January 2004
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 42 (11) , 1204-11
Therapeutic monitoring of immunosuppressant drugs. Where are we?
The emergence of specific immunosuppressive drugs (cyclosporine, tacrolimus, mycophenolate mofetil and sirolimus) during the last two decades has contributed dramatically to the success of organ transplantation. However, optimum balance between therapeutic efficacy and the occurrence of side effects has been a real challenge for physicians, mainly due to inter- and intra-patient variability arising from pharmacokinetic, pharmacogenetic and pharmacodynamic individual properties. Therapeutic drug monitoring, defined as the measurement and interpretation of concentrations of these drugs in biological fluids, with as a final objective the prediction of organ responses, became an integral part of transplant protocols. New analytical techniques became available with different performances in terms of specificity and sensitivity. In addition, there has been progress in understanding the mechanisms of action of these drugs that have implications for the development of better monitoring strategies and for their coprescription. The purpose of this review is to examine the current strategies in use for the therapeutic drug monitoring of immunosuppressant drugs and to discuss some of the factors that impinge on the monitoring of these drugs.
- 21 January 2003
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 41 (7) , 921-5
High-Throughput Liquid Chromatography-Tandem Mass Spectrometric Analysis of Sirolimus in Whole Blood
Sirolimus appears as a new potent immunosuppressive agent taking advantage of therapeutic drug monitoring to optimize its use in organ transplantation. In the absence of any available commercial immunoassay it was mandatory to develop chromatographic assays. Some methods have already been proposed to quantify sirolimus in whole blood, based either on HPLC-UV, liquid chromatography-mass spectrometry (LC-MS) or liquid chromatography-tandem mass spectrometry (LC-MS/MS). We have developed a new faster and simpler LC-MS/MS method to quantify sirolimus in blood using ascomycin as an internal standard and multiple reaction monitoring (MRM) acquisition mode. This method displays a limit of detection of 0.3 microg/l, and the intra-assay reproducibility ranges from 4.1-7.9%. The pre-analytical preparation steps are quite similar to those required for semi-automated immunoassays. Ascomycin and sirolimus present retention times of 0.89 and 0.93 min, respectively, and the turnaround time for a result (2.5 min) is also similar to that observed using a clinical analyzer. The comparison performed between HPLC-UV and LC-MS/MS displays good correlation (r = 0.949). The LC-MS/MS method described above has been used routinely for more than 2000 patient blood specimens and may present several advantages over existing methods, e.g., specificity with sufficient sensitivity, rapidity, and small blood sampling (10 microl), making it particularly adapted for routine clinical use.
- 21 January 2003
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 41 (7) , 921-5
High-Throughput Liquid Chromatography-Tandem Mass Spectrometric Analysis of Sirolimus in Whole Blood
Sirolimus appears as a new potent immunosuppressive agent taking advantage of therapeutic drug monitoring to optimize its use in organ transplantation. In the absence of any available commercial immunoassay it was mandatory to develop chromatographic assays. Some methods have already been proposed to quantify sirolimus in whole blood, based either on HPLC-UV, liquid chromatography-mass spectrometry (LC-MS) or liquid chromatography-tandem mass spectrometry (LC-MS/MS). We have developed a new faster and simpler LC-MS/MS method to quantify sirolimus in blood using ascomycin as an internal standard and multiple reaction monitoring (MRM) acquisition mode. This method displays a limit of detection of 0.3 microg/l, and the intra-assay reproducibility ranges from 4.1-7.9%. The pre-analytical preparation steps are quite similar to those required for semi-automated immunoassays. Ascomycin and sirolimus present retention times of 0.89 and 0.93 min, respectively, and the turnaround time for a result (2.5 min) is also similar to that observed using a clinical analyzer. The comparison performed between HPLC-UV and LC-MS/MS displays good correlation (r = 0.949). The LC-MS/MS method described above has been used routinely for more than 2000 patient blood specimens and may present several advantages over existing methods, e.g., specificity with sufficient sensitivity, rapidity, and small blood sampling (10 microl), making it particularly adapted for routine clinical use.
- 1 January 2001
- Published by Springer Nature in Clinical Pharmacokinetics
- Vol. 40 (4) , 283-295
Comparative Clinical Pharmacokinetics of Tacrolimus in Paediatric and Adult Patients
Tacrolimus is a potent immunosuppressive agent used to prevent allograft rejection. The pharmacokinetics of tacrolimus have been studied in healthy volunteers and transplant recipients, mostly by...
- 1 January 2001
- Published by Springer Nature in Clinical Pharmacokinetics
- Vol. 40 (4) , 283-295
Comparative Clinical Pharmacokinetics of Tacrolimus in Paediatric and Adult Patients
Tacrolimus is a potent immunosuppressive agent used to prevent allograft rejection. The pharmacokinetics of tacrolimus have been studied in healthy volunteers and transplant recipients, mostly by...
- Open Access
- 1 March 1999
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 45 (3) , 432-435
Evaluation of the New AxSYM Cyclosporine Assay: Comparison with TDx Monoclonal Whole Blood and Emit Cyclosporine Assays
Cyclosporine (CsA) is a cyclic undecapeptide that has potent immunosuppressive activity, but its narrow therapeutic range and variable pharmacokinetics in humans make monitoring of CsA mandatory (1). The generally accepted whole-blood therapeutic ranges of CsA (with specific assay) are 100–200 μg/L for renal transplant patients and 150–250 μg/L for cardiac, hepatic, and pancreatic transplant patients during the maintenance phase (2)(3), whereas slightly higher ranges are recommended during the induction phase. The CsA metabolites arising from oxidative pathways (4) cross-react in immunoassays (5)(6), leading to results higher than those by HPLC. Trough concentrations of metabolite AM1, the major metabolite in human blood (1)(4), can exceed those of the parent drug (1). For metabolites AM1, AM9, and AM4N, immunosuppressive activity is <10% of that observed for CsA (7)(8), and at least in rats, various CsA metabolites are not nephrotoxic (9). Thus CsA itself, rather than its metabolites, is the major pharmacologically active substance (10), and specific analytical methods are recommended (3)(11)(12). HPLC is specific but time-consuming and labor-intensive; it also displays the highest between-center CV (1). Three major immunoassays based on different CsA monoclonal antibodies were developed by Abbott, IncStar, and Syva Laboratories: a fluorescence polarization immunoassay (FPIA; for the TDx analyzer), a Cyclo-Trac RIA, and an Emit, respectively (13)(14). All of these immunoassays yield slightly higher concentrations than does HPLC, with FPIA concentrations high by 20–30% (15). The results can be summarized as HPLC < Emit < RIA < TDx.
- 1 March 1999
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 45 (3) , 432-435
Open AccessEvaluation of the New AxSYM Cyclosporine Assay: Comparison with TDx Monoclonal Whole Blood and Emit Cyclosporine Assays
Cyclosporine (CsA) is a cyclic undecapeptide that has potent immunosuppressive activity, but its narrow therapeutic range and variable pharmacokinetics in humans make monitoring of CsA mandatory (1). The generally accepted whole-blood therapeutic ranges of CsA (with specific assay) are 100–200 μg/L for renal transplant patients and 150–250 μg/L for cardiac, hepatic, and pancreatic transplant patients during the maintenance phase (2)(3), whereas slightly higher ranges are recommended during the induction phase. The CsA metabolites arising from oxidative pathways (4) cross-react in immunoassays (5)(6), leading to results higher than those by HPLC. Trough concentrations of metabolite AM1, the major metabolite in human blood (1)(4), can exceed those of the parent drug (1). For metabolites AM1, AM9, and AM4N, immunosuppressive activity is <10% of that observed for CsA (7)(8), and at least in rats, various CsA metabolites are not nephrotoxic (9). Thus CsA itself, rather than its metabolites, is the major pharmacologically active substance (10), and specific analytical methods are recommended (3)(11)(12). HPLC is specific but time-consuming and labor-intensive; it also displays the highest between-center CV (1). Three major immunoassays based on different CsA monoclonal antibodies were developed by Abbott, IncStar, and Syva Laboratories: a fluorescence polarization immunoassay (FPIA; for the TDx analyzer), a Cyclo-Trac RIA, and an Emit, respectively (13)(14). All of these immunoassays yield slightly higher concentrations than does HPLC, with FPIA concentrations high by 20–30% (15). The results can be summarized as HPLC < Emit < RIA < TDx.
- 1 January 1999
- p. 74-8
Simultaneous detection and quantification of acidic and basic drugs in serum toxicological screening: use of ion-pairing technique in liquid-liquid extraction.
The toxicological screening, using the combination of high performance liquid chromatography with diode array ultraviolet detector and ion-pairing technique in liquid-liquid extraction, is an effective tool in the identification and quantification of the acidic and basic substances in a single run. The use of an ion-pairing technique in the conventional extraction shows the co-extraction of the uncharged and charged form of the analytes present in a serum sample. The stationary phase used is C-18-bonded phase. The mobile phase is acetonitrile--phosphate buffer (pH 3; 25 mM) containing 25 mM triethylammonium as ion-pairing agent. The analytical validation shows reproducible recoveries, good day-to-day repeatability and sensible results compatible with clinical and forensic use.
- 1 January 1999
- p. 74-8
Simultaneous detection and quantification of acidic and basic drugs in serum toxicological screening: use of ion-pairing technique in liquid-liquid extraction.
The toxicological screening, using the combination of high performance liquid chromatography with diode array ultraviolet detector and ion-pairing technique in liquid-liquid extraction, is an effective tool in the identification and quantification of the acidic and basic substances in a single run. The use of an ion-pairing technique in the conventional extraction shows the co-extraction of the uncharged and charged form of the analytes present in a serum sample. The stationary phase used is C-18-bonded phase. The mobile phase is acetonitrile--phosphate buffer (pH 3; 25 mM) containing 25 mM triethylammonium as ion-pairing agent. The analytical validation shows reproducible recoveries, good day-to-day repeatability and sensible results compatible with clinical and forensic use.
- Open Access
- 1 October 1997
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 43 (10) , 1989-1991
IMx Tacrolimus II vs IMx Tacrolimus Microparticle Enzyme Immunoassay Evaluated in Renal and Hepatic Transplant Patients
In 1992, an automated whole-blood microparticle enzyme immunoassay was developed (Abbott Labs.) for the measurement of tacrolimus concentrations (TAC I) on the IMx analyzer (1). This method involves the antitacrolimus monoclonal antibody developed by Fujisawa Pharmaceutical, the company producing the immunosuppressant tacrolimus (2). The assay requires 100 μL of whole blood, and 24 samples can be analyzed in ∼40 min after a rapid organic extraction (200 μL of precipitation reagent: ZnSO4 solution in methanol and ethylene glycol). The capture reagent consists of latex microparticles to which tacrolimus antibodies are attached, the enzyme is tacrolimus-conjugated alkaline phosphatase, and the substrate is 4-methylumbelliferyl phosphate. This method yields CVs of ∼10% (11.8% and 9.6% at concentrations of 15 and 25 μg/L, respectively) (1), but is limited by the detection limit of 5 μg/L. Because in current clinical practice a nonnegligible percentage of transplant patients display low tacrolimus concentrations (<6 μg/L), the immunoassay has recently been modified. A new assay, IMx tacrolimus II (TAC II), with a lower detection limit, has been developed, requiring 150 μL of whole blood and 150 μL of precipitation reagent. Whereas the TAC I has a dynamic range of quantification from 5 to 60 μg/L, the TAC II assay has a range from 1 to 30 μg/L, better corresponding to the therapeutic range of tacrolimus (5–15 μg/L) (3). Because this new assay will replace the TAC I, we have evaluated and compared the two assays in terms of their analytical performances, and their correlation in clinical blood specimens obtained from kidney and liver transplant patients.
- 1 October 1997
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 43 (10) , 1989-1991
Open AccessIMx Tacrolimus II vs IMx Tacrolimus Microparticle Enzyme Immunoassay Evaluated in Renal and Hepatic Transplant Patients
In 1992, an automated whole-blood microparticle enzyme immunoassay was developed (Abbott Labs.) for the measurement of tacrolimus concentrations (TAC I) on the IMx analyzer (1). This method involves the antitacrolimus monoclonal antibody developed by Fujisawa Pharmaceutical, the company producing the immunosuppressant tacrolimus (2). The assay requires 100 μL of whole blood, and 24 samples can be analyzed in ∼40 min after a rapid organic extraction (200 μL of precipitation reagent: ZnSO4 solution in methanol and ethylene glycol). The capture reagent consists of latex microparticles to which tacrolimus antibodies are attached, the enzyme is tacrolimus-conjugated alkaline phosphatase, and the substrate is 4-methylumbelliferyl phosphate. This method yields CVs of ∼10% (11.8% and 9.6% at concentrations of 15 and 25 μg/L, respectively) (1), but is limited by the detection limit of 5 μg/L. Because in current clinical practice a nonnegligible percentage of transplant patients display low tacrolimus concentrations (<6 μg/L), the immunoassay has recently been modified. A new assay, IMx tacrolimus II (TAC II), with a lower detection limit, has been developed, requiring 150 μL of whole blood and 150 μL of precipitation reagent. Whereas the TAC I has a dynamic range of quantification from 5 to 60 μg/L, the TAC II assay has a range from 1 to 30 μg/L, better corresponding to the therapeutic range of tacrolimus (5–15 μg/L) (3). Because this new assay will replace the TAC I, we have evaluated and compared the two assays in terms of their analytical performances, and their correlation in clinical blood specimens obtained from kidney and liver transplant patients.
- Open Access
- 1 July 1997
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 43 (7) , 1238-1240
Topical Application of Eosin to Burns Produces Interference in Measurement of Serum Vancomycin by Fluorescence Polarization Immunoassay
Vancomycin, a gram-positive bactericidal agent, represents the drug of choice for infections caused by methicilin-resistant Staphylococcus aureus, common microorganisms implicated in infections and systemic sepsis in burned patients. Even though the toxicity of the current method of preparation of vancomycin has been reduced by an improved purification method (1), the concentration of vancomycin in the blood should be monitored closely in burned patients to maintain adequate anti-infective concentrations in patients with particularly high total body clearance and volume of distribution. This monitoring can be performed by determining the peak and trough serum concentrations of vancomycin. For this purpose, different analytical techniques are available, mainly immunoassays such as the fluorescence polarization immunoassay (FPIA) developed by Abbott Diagnostic Laboratories (Chicago, IL) (2) on the TDx analyzer and the enzyme-multiplied immunotechnique assay (Emit) developed by Syva–Behring Laboratories (San Jose, CA). FPIA is a fast, reliable, and automated technique frequently used in large laboratories. However, in a few selected situations some interferences may occur. One possible interference has been reported to be due to accumulating vancomycin degradation products in renal failure (3)(4), which could result in overestimated concentrations. However, a recent study conducted in patients with renal dysfunction did not report any substantial differences in the vancomycin concentrations obtained by FPIA and Emit during the first week after the onset of the treatment (5).
- 1 July 1997
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 43 (7) , 1238-1240
Open AccessTopical Application of Eosin to Burns Produces Interference in Measurement of Serum Vancomycin by Fluorescence Polarization Immunoassay
Vancomycin, a gram-positive bactericidal agent, represents the drug of choice for infections caused by methicilin-resistant Staphylococcus aureus, common microorganisms implicated in infections and systemic sepsis in burned patients. Even though the toxicity of the current method of preparation of vancomycin has been reduced by an improved purification method (1), the concentration of vancomycin in the blood should be monitored closely in burned patients to maintain adequate anti-infective concentrations in patients with particularly high total body clearance and volume of distribution. This monitoring can be performed by determining the peak and trough serum concentrations of vancomycin. For this purpose, different analytical techniques are available, mainly immunoassays such as the fluorescence polarization immunoassay (FPIA) developed by Abbott Diagnostic Laboratories (Chicago, IL) (2) on the TDx analyzer and the enzyme-multiplied immunotechnique assay (Emit) developed by Syva–Behring Laboratories (San Jose, CA). FPIA is a fast, reliable, and automated technique frequently used in large laboratories. However, in a few selected situations some interferences may occur. One possible interference has been reported to be due to accumulating vancomycin degradation products in renal failure (3)(4), which could result in overestimated concentrations. However, a recent study conducted in patients with renal dysfunction did not report any substantial differences in the vancomycin concentrations obtained by FPIA and Emit during the first week after the onset of the treatment (5).