Naoya Kakimoto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Naoya Kakimoto has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
- Shumei Murakami
Department of Oral and Maxillofacial Radiology, Osaka University Graduate School of Dentistry, Osaka, Japan
6 shared publications Souhei Furukawa
6 shared publications- Souhei Furukawa
Department of Oral and Maxillofacial Radiology, Osaka University Graduate School of Dentistry, Osaka, Japan
6 shared publications Jira Chindasombatjaroen
Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Mahidol University, Bangkok, Thailand
5 shared publicationsShumei Murakami
5 shared publicationsMitsunobu Kishino
4 shared publications
Latest Publications
- 1 April 2017
- Published by Wiley in Journal of Dental Education
- Vol. 81 (4) , 450-457
Stereoscopy in Dental Education: An Investigation
The aim of this study was to investigate whether stereoscopy can play a meaningful role in dental education. The study used an anaglyph technique in which two images were presented separately to the left and right eyes (using red/cyan filters), which, combined in the brain, give enhanced depth perception. A positional judgment task was performed to assess whether the use of stereoscopy would enhance depth perception among dental students at Osaka University in Japan. Subsequently, the optimum angle was evaluated to obtain maximum ability to discriminate among complex anatomical structures. Finally, students completed a questionnaire on a range of matters concerning their experience with stereoscopic images including their views on using stereoscopy in their future careers. The results showed that the students who used stereoscopy were better able than students who did not to appreciate spatial relationships between structures when judging relative positions. The maximum ability to discriminate among complex anatomical structures was between 2 and 6 degrees. The students' overall experience with the technique was positive, and although most did not have a clear vision for stereoscopy in their own practice, they did recognize its merits for education. These results suggest that using stereoscopic images in dental education can be quite valuable as stereoscopy greatly helped these students' understanding of the spatial relationships in complex anatomical structures.
- 1 April 2017
- Published by Wiley in Journal of Dental Education
- Vol. 81 (4) , 450-457
Stereoscopy in Dental Education: An Investigation
The aim of this study was to investigate whether stereoscopy can play a meaningful role in dental education. The study used an anaglyph technique in which two images were presented separately to the left and right eyes (using red/cyan filters), which, combined in the brain, give enhanced depth perception. A positional judgment task was performed to assess whether the use of stereoscopy would enhance depth perception among dental students at Osaka University in Japan. Subsequently, the optimum angle was evaluated to obtain maximum ability to discriminate among complex anatomical structures. Finally, students completed a questionnaire on a range of matters concerning their experience with stereoscopic images including their views on using stereoscopy in their future careers. The results showed that the students who used stereoscopy were better able than students who did not to appreciate spatial relationships between structures when judging relative positions. The maximum ability to discriminate among complex anatomical structures was between 2 and 6 degrees. The students' overall experience with the technique was positive, and although most did not have a clear vision for stereoscopy in their own practice, they did recognize its merits for education. These results suggest that using stereoscopic images in dental education can be quite valuable as stereoscopy greatly helped these students' understanding of the spatial relationships in complex anatomical structures.
- 1 October 2016
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 45 (8) , 20160094
A standardized evaluation of artefacts from metallic compounds during fast MR imaging
Objective:Metallic compounds present in the oral and maxillofacial regions (OMR) cause large artifacts during MR scanning. We quantitatively assessed these artifacts embedded within a phantom according to standards set by the American Society for Testing and Materials (ASTM).Materials and Methods:Seven metallic dental materials (each of which was a 10mm3 cube embedded within a phantom) were scanned (i.e. Al, Ag, Au, Au-Pd-Ag, Ti, NC and CC) and compared to a reference image. Sequences included GRE, FSE, GRASS, SPGR, FSPGR, FIESTA and EPI (axial/sagittal planes). Artifact areas were determined according to the ASTM-F2119 standard and artifact volumes were assessed using OsiriX MD softwareResults:Tukey-Kramer post-hoc tests were used for statistical comparisons. For most materials, scanning sequences eliciting artifact volumes in the following (ascending) order FSE-T1/FSE-T2 < FSPGR/SPGR < GRASS/GRE < FIESTA < EPI. For all scanning sequences, artifact volumes containing Au, Al, Ag and Au-Pd-Ag, were signifi...
- 1 October 2016
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 45 (8) , 20160094
A standardized evaluation of artefacts from metallic compounds during fast MR imaging
Objective:Metallic compounds present in the oral and maxillofacial regions (OMR) cause large artifacts during MR scanning. We quantitatively assessed these artifacts embedded within a phantom according to standards set by the American Society for Testing and Materials (ASTM).Materials and Methods:Seven metallic dental materials (each of which was a 10mm3 cube embedded within a phantom) were scanned (i.e. Al, Ag, Au, Au-Pd-Ag, Ti, NC and CC) and compared to a reference image. Sequences included GRE, FSE, GRASS, SPGR, FSPGR, FIESTA and EPI (axial/sagittal planes). Artifact areas were determined according to the ASTM-F2119 standard and artifact volumes were assessed using OsiriX MD softwareResults:Tukey-Kramer post-hoc tests were used for statistical comparisons. For most materials, scanning sequences eliciting artifact volumes in the following (ascending) order FSE-T1/FSE-T2 < FSPGR/SPGR < GRASS/GRE < FIESTA < EPI. For all scanning sequences, artifact volumes containing Au, Al, Ag and Au-Pd-Ag, were signifi...
- Open Access
- 17 April 2014
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 35 (7) , 1412-1417
Comparison of the T2 Relaxation Time of the Temporomandibular Joint Articular Disk between Patients with Temporomandibular Disorders and Asymptomatic Volunteers
BACKGROUND AND PURPOSE: T2 relaxation time is a quantitative MR imaging parameter used to detect degenerated cartilage in the knee and lumbar intervertebral disks. We measured the T2 relaxation time of the articular disk of the temporomandibular joint in patients with temporomandibular disorders and asymptomatic volunteers to demonstrate an association between T2 relaxation time and temporomandibular disorder MR imaging findings. MATERIALS AND METHODS: One hundred forty-four patients with temporomandibular disorders and 17 volunteers were enrolled in this study. An 8-echo spin-echo sequence for measuring the T2 relaxation times was performed in the closed mouth position, and the T2 relaxation time of the entire articular disk was measured. Patients were classified according to the articular disk location and function, articular disk configuration, presence of joint effusion, osteoarthritis, and bone marrow abnormalities. RESULTS: The T2 relaxation time of the entire articular disk was 29.3 ± 3.8 ms in the volunteer group and 30.7 ± 5.1 ms in the patient group (P = .177). When subgroups were analyzed, however, the T2 relaxation times of the entire articular disk in the anterior disk displacement without reduction group, the marked or extensive joint effusion group, the osteoarthritis-positive group, and the bone marrow abnormality–positive group were significantly longer than those in the volunteer group (P < .05). CONCLUSIONS: The T2 relaxation times of the articular disk of the temporomandibular joint in patients with progressive temporomandibular disorders were longer than those of healthy volunteers.
- 17 April 2014
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 35 (7) , 1412-1417
Open AccessComparison of the T2 Relaxation Time of the Temporomandibular Joint Articular Disk between Patients with Temporomandibular Disorders and Asymptomatic Volunteers
BACKGROUND AND PURPOSE: T2 relaxation time is a quantitative MR imaging parameter used to detect degenerated cartilage in the knee and lumbar intervertebral disks. We measured the T2 relaxation time of the articular disk of the temporomandibular joint in patients with temporomandibular disorders and asymptomatic volunteers to demonstrate an association between T2 relaxation time and temporomandibular disorder MR imaging findings. MATERIALS AND METHODS: One hundred forty-four patients with temporomandibular disorders and 17 volunteers were enrolled in this study. An 8-echo spin-echo sequence for measuring the T2 relaxation times was performed in the closed mouth position, and the T2 relaxation time of the entire articular disk was measured. Patients were classified according to the articular disk location and function, articular disk configuration, presence of joint effusion, osteoarthritis, and bone marrow abnormalities. RESULTS: The T2 relaxation time of the entire articular disk was 29.3 ± 3.8 ms in the volunteer group and 30.7 ± 5.1 ms in the patient group (P = .177). When subgroups were analyzed, however, the T2 relaxation times of the entire articular disk in the anterior disk displacement without reduction group, the marked or extensive joint effusion group, the osteoarthritis-positive group, and the bone marrow abnormality–positive group were significantly longer than those in the volunteer group (P < .05). CONCLUSIONS: The T2 relaxation times of the articular disk of the temporomandibular joint in patients with progressive temporomandibular disorders were longer than those of healthy volunteers.
- 1 January 2013
- Published by Elsevier in Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology
- Vol. 115 (1) , 104-113
Contrast-enhanced multidetector computerized tomography for odontogenic cysts and cystic-appearing tumors of the jaws: is it useful?
- 1 January 2013
- Published by Elsevier in Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology
- Vol. 115 (1) , 104-113
Contrast-enhanced multidetector computerized tomography for odontogenic cysts and cystic-appearing tumors of the jaws: is it useful?
- 1 July 2012
- Published by Springer Nature in Oral Radiology
- Vol. 28 (2) , 115-120
Effects of cepharanthine with or without Z-100 against leukopenia during radiation therapy for oral cancer
- 1 July 2012
- Published by Springer Nature in Oral Radiology
- Vol. 28 (2) , 115-120
Effects of cepharanthine with or without Z-100 against leukopenia during radiation therapy for oral cancer
- 31 May 2012
- Published by Elsevier in Oral Oncology
- Vol. 48 (5) , 463-468
Electron beam radiotherapy for tongue cancer using an intra-oral cone
- 31 May 2012
- Published by Elsevier in Oral Oncology
- Vol. 48 (5) , 463-468
Electron beam radiotherapy for tongue cancer using an intra-oral cone
- 1 September 2011
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 35 (5) , 662-665
Correlation Between Pixel Values in a Cone-Beam Computed Tomographic Scanner and the Computed Tomographic Values in a Multidetector Row Computed Tomographic Scanner
Objectives: The study's objectives were to investigate the correlation between pixel values obtained from a cone-beam computed tomographic (CBCT) scanner and the computed tomographic (CT) values from a multidetector row CT scanner and to determine whether they have a linear relationship at various tube voltages and tube currents. Methods: A phantom with different concentrations of contrast medium at the center of a multidetector row CT and a CBCT scanner was scanned at various imaging parameters. Computed tomographic values and pixel values were measured using ImageJ. Regression analysis was performed, as well as correlation tests with a Pearson correlation coefficient. Results: A significant correlation between pixel values and the CT values of the same specimen was observed (P < 0.0001), and a linear relationship was found between the values from the 2 scanners at each parameter. Conclusions: A high correlation and linear relationship between the CT values and pixel values were found at each parameter. Therefore, linear functions can be used to convert a pixel value from the CBCT machine used in this study to the CT values.
- 1 September 2011
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 35 (5) , 662-665
Correlation Between Pixel Values in a Cone-Beam Computed Tomographic Scanner and the Computed Tomographic Values in a Multidetector Row Computed Tomographic Scanner
Objectives: The study's objectives were to investigate the correlation between pixel values obtained from a cone-beam computed tomographic (CBCT) scanner and the computed tomographic (CT) values from a multidetector row CT scanner and to determine whether they have a linear relationship at various tube voltages and tube currents. Methods: A phantom with different concentrations of contrast medium at the center of a multidetector row CT and a CBCT scanner was scanned at various imaging parameters. Computed tomographic values and pixel values were measured using ImageJ. Regression analysis was performed, as well as correlation tests with a Pearson correlation coefficient. Results: A significant correlation between pixel values and the CT values of the same specimen was observed (P < 0.0001), and a linear relationship was found between the values from the 2 scanners at each parameter. Conclusions: A high correlation and linear relationship between the CT values and pixel values were found at each parameter. Therefore, linear functions can be used to convert a pixel value from the CBCT machine used in this study to the CT values.
- 30 June 2011
- Published by Springer Nature in Oral Radiology
- Vol. 27 (2) , 114-120
Quantitative analysis of metallic artifacts caused by dental metals: comparison of cone-beam and multi-detector row CT scanners
- 30 June 2011
- Published by Springer Nature in Oral Radiology
- Vol. 27 (2) , 114-120
Quantitative analysis of metallic artifacts caused by dental metals: comparison of cone-beam and multi-detector row CT scanners