Michala Rampichová
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Michala Rampichová has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Jiří Chvojka
Department of Nonwovens and Nanofibrous Materials, Faculty of Textile, Technical University of Liberec, 461 17 Liberec, Czech Republic
3 shared publications - David Lukas
Technical University of Liberec
2 shared publications E. Amler
A University Center for Energy Efficient Buildings (UCEEB), Czech Technical University in Prague , Buštěhrad , Czech Republic
2 shared publicationsE. Prosecká
B Laboratory of Tissue Engineering, Institute of Experimental Medicine, Czech Academy of Sciences , Prague , Czech Republic
2 shared publications- Eva Filová
Institute of Experimental Medicine of the Czech Academy of Sciences, Videnska 1083, 142 20 Prague, Czech Republic
2 shared publications - Matej Buzgo
Respilon Membranes s.r.o., Nové sady 988/2, Staré Brno, 602 00 Brno, Czech Republic
2 shared publications
Latest Publications
- 13 November 2017
- Published by Taylor & Francis in Cell Adhesion & Migration
- Vol. 12 (3) , 271-285
Composite 3D printed scaffold with structured electrospun nanofibers promotes chondrocyte adhesion and infiltration
Additive manufacturing, also called 3D printing, is an effective method for preparing scaffolds with defined structure and porosity. The disadvantage of the technique is the excessive smoothness of the printed fibers, which does not support cell adhesion. In the present study, a 3D printed scaffold was combined with electrospun classic or structured nanofibers to promote cell adhesion. Structured nanofibers were used to improve the infiltration of cells into the scaffold. Electrospun layers were connected to 3D printed fibers by gluing, thus enabling the fabrication of scaffolds with unlimited thickness. The composite 3D printed/nanofibrous scaffolds were seeded with primary chondrocytes and tested in vitro for cell adhesion, proliferation and differentiation. The experiment showed excellent cell infiltration, viability, and good cell proliferation. On the other hand, partial chondrocyte dedifferentiation was shown. Other materials supporting chondrogenic differentiation will be investigated in future studies.
- 13 November 2017
- Published by Taylor & Francis in Cell Adhesion & Migration
- Vol. 12 (3) , 271-285
Composite 3D printed scaffold with structured electrospun nanofibers promotes chondrocyte adhesion and infiltration
Additive manufacturing, also called 3D printing, is an effective method for preparing scaffolds with defined structure and porosity. The disadvantage of the technique is the excessive smoothness of the printed fibers, which does not support cell adhesion. In the present study, a 3D printed scaffold was combined with electrospun classic or structured nanofibers to promote cell adhesion. Structured nanofibers were used to improve the infiltration of cells into the scaffold. Electrospun layers were connected to 3D printed fibers by gluing, thus enabling the fabrication of scaffolds with unlimited thickness. The composite 3D printed/nanofibrous scaffolds were seeded with primary chondrocytes and tested in vitro for cell adhesion, proliferation and differentiation. The experiment showed excellent cell infiltration, viability, and good cell proliferation. On the other hand, partial chondrocyte dedifferentiation was shown. Other materials supporting chondrogenic differentiation will be investigated in future studies.
- Open Access
- 1 January 2013
- Published by Taylor & Francis in Cell Adhesion & Migration
- Vol. 8 (1) , 36-41
Cell penetration to nanofibrous scaffolds
Cell infiltration is a critical parameter for the successful development of 3D matrices for tissue engineering. Application of electrospun nanofibers in tissue engineering has recently attracted much attention. Notwithstanding several of their advantages, small pore size and small thickness of the electrospun layer limit their application for development of 3D scaffolds. Several methods for the pore size and/or electrospun layer thickness increase have been recently developed. Nevertheless, tissue engineering still needs emerging of either novel nanofiber-enriched composites or new techniques for 3D nanofiber fabrication. Forcespinning(®) seems to be a promising alternative. The potential of the Forcespinning(®) method is illustrated in preliminary experiment with mesenchymal stem cells.
- 1 January 2013
- Published by Taylor & Francis in Cell Adhesion & Migration
- Vol. 8 (1) , 36-41
Open AccessCell penetration to nanofibrous scaffolds
Cell infiltration is a critical parameter for the successful development of 3D matrices for tissue engineering. Application of electrospun nanofibers in tissue engineering has recently attracted much attention. Notwithstanding several of their advantages, small pore size and small thickness of the electrospun layer limit their application for development of 3D scaffolds. Several methods for the pore size and/or electrospun layer thickness increase have been recently developed. Nevertheless, tissue engineering still needs emerging of either novel nanofiber-enriched composites or new techniques for 3D nanofiber fabrication. Forcespinning(®) seems to be a promising alternative. The potential of the Forcespinning(®) method is illustrated in preliminary experiment with mesenchymal stem cells.
- 7 December 2012
- Published by Wiley in Cell Proliferation
- Vol. 46 (1) , 23-37
Elastic three‐dimensional poly (ε‐caprolactone) nanofibre scaffold enhances migration, proliferation and osteogenic differentiation of mesenchymal stem cells
Objectives: We prepared 3D poly (ε‐caprolactone) (PCL) nanofibre scaffolds and tested their use for seeding, proliferation, differentiation and migration of mesenchymal stem cell (MSCs).Materials and methods: 3D nanofibres were prepared using a special collector for common electrospinning; simultaneously, a 2D PCL nanofibre layer was prepared using a classic plain collector. Both scaffolds were seeded with MSCs and biologically tested. MSC adhesion, migration, proliferation and osteogenic differentiation were investigated.Results: The 3D PCL scaffold was characterized by having better biomechanical properties, namely greater elasticity and resistance against stress and strain, thus this scaffold will be able to find broad applications in tissue engineering. Clearly, while nanofibre layers of the 2D scaffold prevented MSCs from migrating through the conformation, cells infiltrated freely through the 3D scaffold. MSC adhesion to the 3D nanofibre PCL layer was also statistically more common than to the 2D scaffold (P < 0.05), and proliferation and viability of MSCs 2 or 3 weeks post‐seeding, were also greater on the 3D scaffold. In addition, the 3D PCL scaffold was also characterized by displaying enhanced MSC osteogenic differentiation.Conclusions: We draw the conclusion that all positive effects observed using the 3D PCL nanofibre scaffold are related to the larger fibre surface area available to the cells. Thus, the proposed 3D structure of the nanofibre layer will find a wide array of applications in tissue engineering and regenerative medicine.
- 7 December 2012
- Published by Wiley in Cell Proliferation
- Vol. 46 (1) , 23-37
Elastic three‐dimensional poly (ε‐caprolactone) nanofibre scaffold enhances migration, proliferation and osteogenic differentiation of mesenchymal stem cells
Objectives: We prepared 3D poly (ε‐caprolactone) (PCL) nanofibre scaffolds and tested their use for seeding, proliferation, differentiation and migration of mesenchymal stem cell (MSCs).Materials and methods: 3D nanofibres were prepared using a special collector for common electrospinning; simultaneously, a 2D PCL nanofibre layer was prepared using a classic plain collector. Both scaffolds were seeded with MSCs and biologically tested. MSC adhesion, migration, proliferation and osteogenic differentiation were investigated.Results: The 3D PCL scaffold was characterized by having better biomechanical properties, namely greater elasticity and resistance against stress and strain, thus this scaffold will be able to find broad applications in tissue engineering. Clearly, while nanofibre layers of the 2D scaffold prevented MSCs from migrating through the conformation, cells infiltrated freely through the 3D scaffold. MSC adhesion to the 3D nanofibre PCL layer was also statistically more common than to the 2D scaffold (P < 0.05), and proliferation and viability of MSCs 2 or 3 weeks post‐seeding, were also greater on the 3D scaffold. In addition, the 3D PCL scaffold was also characterized by displaying enhanced MSC osteogenic differentiation.Conclusions: We draw the conclusion that all positive effects observed using the 3D PCL nanofibre scaffold are related to the larger fibre surface area available to the cells. Thus, the proposed 3D structure of the nanofibre layer will find a wide array of applications in tissue engineering and regenerative medicine.
- 31 May 2007
- p. S61-8
Biomechanical characterization of cartilages by a novel approach of blunt impact testing.
The present article introduces a novel method of characterizing the macromechanical cartilage properties based on dynamic testing. The proposed approach of instrumented impact testing shows the possibility of more detailed investigation of the acting dynamic forces and corresponding deformations within the wide range of strain rates and loads, including the unloading part of stress-strain curves and hysteresis loops. The presented results of the unconfined compression testing of both the native joint cartilage tissues and potential substitute materials outlined the opportunity to measure the dissipation energy and thus to identify the initial mechanical deterioration symptoms and to introduce a better definition of material damage. Based on the analysis of measured specimen deformation, the intact and pathologically changed cartilage tissue can be distinguished and the differences revealed.
- 31 May 2007
- p. S61-8
Biomechanical characterization of cartilages by a novel approach of blunt impact testing.
The present article introduces a novel method of characterizing the macromechanical cartilage properties based on dynamic testing. The proposed approach of instrumented impact testing shows the possibility of more detailed investigation of the acting dynamic forces and corresponding deformations within the wide range of strain rates and loads, including the unloading part of stress-strain curves and hysteresis loops. The presented results of the unconfined compression testing of both the native joint cartilage tissues and potential substitute materials outlined the opportunity to measure the dissipation energy and thus to identify the initial mechanical deterioration symptoms and to introduce a better definition of material damage. Based on the analysis of measured specimen deformation, the intact and pathologically changed cartilage tissue can be distinguished and the differences revealed.