JLJuin-Yih Lai

Juin-Yih Lai

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Juin-Yih Lai has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Preparation of Immunotherapy Liposomal-Loaded Thermal-Responsive Hydrogel Carrier in the Local Treatment of Breast Cancer

    by Hsieh-Chih Tsai, Hsiao-Ying Chou, Shun-Hao Chuang, Juin-Yih Lai, Yi-Shu Chen, Yu-Han Wen, Lu-Yi Yu, Chun-Liang Lo

    To reduce the side effects of immune drugs and the sustainable release of immune drugs on local parts, we have designed an injectable thermal-sensitive hydrogel containing an imiquimod-loaded liposome system. In the extracellular environment of tumor tissues (pH 6.4), 50% of the drug was released from the carrier, which could be a result of the morphological changes of the liposomal microstructure in the acidic environment. According to the results in animals, the drug-containing liposomes combined with hydrogel can be effectively applied in breast cancer therapy to delay the growth of tumors as well as to dramatically reduce the death rate of mice.


  • Open Access

    Synthesis of “Dahlia-Like” Hydrophilic Fluorescent Carbon Nanohorn as a Bio-Imaging PROBE

    by Perumalswamy Sekar Parasuraman, Vijaya Rohini Parasuraman, Rajeshkumar Anbazhagan, Hsieh-Chih Tsai, Juin-Yih Lai

    Carbon nanohorns (CNH) were synthesized by a simple conventional hydrothermal method in this study. The CNHs were prepared by the chemical oxidation from the carbonation of Nafion (catalyst) with heparin (carbon resource). The formation of CNH involved two major steps, as described followed. First, the formation of carbon nanorice (CNR) was achieved by carbonation and self-assembly of heparin inside the Nafion structure. Second, the further oxidation of CNR resulted the heterogeneous and porous micelle domains showed at the outer layer of the CNR particles. These porous domains exhibited hydrophobic carbon and resulted self-assembly of the CNR to form the structure of CNHs. The resulting CNHs aggregated into a “dahlia-like” morphology with fluorescence in a diameter of 50–200 nm. The “dahlia-like” CNH showed better fluorescence (450nm) than CNR particles because of the presence of more structural defect. These findings suggest that the hydrophilic fluorescent carbon nanohorns (HFCNHs) synthesized in this study have the potential to be used for in vitro bio-imaging


  • Open Access

    Correlating PSf Support Physicochemical Properties with the Formation of Piperazine-Based Polyamide and Evaluating the Resultant Nanofiltration Membrane Performance

    by Micah Belle Marie Yap Ang, Victor Jr. Lau, Yan-Li Ji, Shu-Hsien Huang, Quan-Fu An, Alvin R. Caparanga, Hui-An Tsai, Wei-Song Hung, Chien-Chieh Hu, Kueir-Rarn Lee, et al.

    Membrane support properties influence the performance of thin-film composite nanofiltration membranes. We fabricated several polysulfone (PSf) supports. The physicochemical properties of PSf were altered by adding polyethylene glycol (PEG) of varying molecular weights (200–35,000 g/mol). This alteration facilitated the formation of a thin polyamide layer on the PSf surface during the interfacial polymerization reaction involving an aqueous solution of piperazine containing 4-aminobenzoic acid and an organic solution of trimesoyl chloride. Attenuated total reflectance-Fourier transform infrared validated the presence of PEG in the membrane support. Scanning electron microscopy and atomic force microscopy illustrated that the thin-film polyamide layer morphology transformed from a rough to a smooth surface. A cross-flow filtration test indicated that a thin-film composite polyamide membrane comprising a PSf support (TFC-PEG20k) with a low surface porosity, small pore size, and suitable hydrophilicity delivered the highest water flux and separation efficiency (J = 81.1 ± 6.4 L·m−2·h−1, RNa2SO4 = 91.1% ± 1.8%, and RNaCl = 35.7% ± 3.1% at 0.60 MPa). This membrane had a molecular weight cutoff of 292 g/mol and also a high rejection for negatively charged dyes. Therefore, a PSf support exhibiting suitable physicochemical properties endowed a thin-film composite polyamide membrane with high performance.


  • Open Access

    Polymer Inclusion Membranes with Strip Dispersion

    by Yueh-Hsien Li, Da-Ming Wang, Tzu-Yang Hsien, Kuan-Ying Chan, Juin-Yih Lai

    The present work investigated the permeation of indium ions through a polymer inclusion membrane (PIM), prepared with cellulose triacetate (CTA) as the base polymer, tris(2-butoxyethyl) phosphate (TBEP) as the plasticizer and di-(2-ethylhexyl)phosphoric acid (D2EHPA) as the extractant. With 5 M HCl aqueous solution as the strip solution, we observed an initial indium permeability of 2.4 × 10−4 m/min. However, the permeability decreases with time, dropping to about 3.4 × 10−5 m/min after 200 min of operation. Evidence was obtained showing that hydrolysis of CTA occurred, causing a dramatic decrease in the feed pH (protons transported from strip to feed solutions) and a loss of extractant and plasticizer from the membrane, and then leading to the loss of indium permeability. To alleviate the problem of hydrolysis, we proposed an operation scheme called polymer inclusion membranes with strip dispersion: dispersing the strip solution in extractant-containing oil and then bringing the dispersion to contact with the polymer membrane. Since the strong acid was dispersed in oil, the membrane did not directly contact the strong acid at all times, and membrane hydrolysis was thus alleviated and the loss of indium permeability was effectively prevented. With the proposed scheme, a stable indium permeability of 2.5 × 10−4 m/min was obtained during the whole time period of the permeation experiment.


  • Non-destructive means of probing a composite polyamide membrane for characteristic free volume, void, and chemical composition

    by Wei-Song Hung, Quan-Fu An, Chien-Chieh Hu, Kueir-Rarn Lee, Yan-Ching Jean, Juin-Yih Lai

    Positron annihilation spectroscopy measures free volume in membranes at the sub-nanometer scale (0.1–1 nm). In this study, we used positron annihilation age–momentum correlation (AMOC) spectroscopy coupled to a variable mono-energy slow positron beam; our objectives were to measure not only free volume but also voids that are bigger than 1 nm and to estimate the chemical composition of a composite polyamide membrane. To crosscheck these data, we also used conventional techniques: scanning electron microscopy, transmission electron microscopy, and quantum chemical calculations (QCC). AMOC showed that the free volume diameters and intensities in a polyamide layer were in the range of 0.42–0.68 nm and 9–3%, respectively, and that the void diameters and intensities were 7.2–14.1 nm and 12–18%, respectively, with the size distribution of the voids ranging from 5 to 20 nm. These results were consistent with those from TEM, indicating that the polyamide layer structure consisted of discrete voids distributed throughout a continuously dense phase. QCC validated the S parameter data taken from AMOC, which showed that a highly electronegative environment in the polyamide layer could inhibit the formation of positronium.


  • Effects of the polymerization and pervaporation operating conditions on the dehydration performance of interfacially polymerized thin‐film composite membranes

    by Shu‐Hsien Huang, George J. Jiang, Der‐Jang Liaw, Chi‐Lan Li, Chien‐Chieh Hu, Kueir‐Rarn Lee, Juin‐Yih Lai

    The disadvantage of dense polyamide membranes when applied in the pervaporation separation process is their low permeation rates. To improve the pervaporation performance, polyamide thin‐film composite membranes were prepared via the interfacial polymerization reaction between ethylenediamine (EDA) and trimesoyl chloride (TMC) on the surface of modified polyacrylonitrile (mPAN) membranes. These composite membranes were applied in the pervaporation separation of alcohol aqueous solutions. On the basis of the best pervaporation performance, the desired polymerization conditions for preparing the polyamide thin‐film composite membranes (EDA–TMC/mPAN) were as follows: (1) the respective concentration and contact time of the EDA aqueous solution were 5 wt % and 30 min and (2) the respective concentration of and immersion time in the TMC organic solution were 1 wt % and 3 min. The polyamide thin‐film composite membranes (EDA–TMC/mPAN) exhibited membrane durability when applied in the pervaporation separation of a 90 wt % isopropyl alcohol aqueous solution at 70°C, which indicated that the polyamide thin film composite (TFC) membranes were suitable for the pervaporation separation process at a high operating temperature. © 2009 Wiley Periodicals, Inc. J Appl Polym Sci, 2009


  • Polyvinyl Alcohol γ-Ray Grafted Nylon 4 Membrane for Pervaporation and Evapomeation

    by Juin-Yih Lai, Rong-Yuh Chen, Kueir Rarn Lee

    Nylon 4, which possesses high mechanical strength and good affinity for water, can be considered as a liquid separation membrane. To improve the hydrophilicity of a Nylon 4 membrane for pervaporation and evapomeation processes, and to overcome the hydrolysis of polyvinyl alcohol (PVA), this study attempts to prepare a PVA-g-Nylon 4 membrane by γ-ray irradiation grafting of vinyl acetate (VAc) onto Nylon 4 membrane, followed by hydrolysis treatment. The effects of down-stream pressure, irradiation dose, VAc monomer concentration, degree of grafting, feed composition, and size of alcohols on the separation of water–alcohol mixtures were studied. The surface properties of the prepared membrane were characterized by FTIR, ESCA, and a contact angle meter. A separation factor of 13.8 and a permeation rate of 0.352 kg/m2·h can be obtained for a PVA-g-Nylon 4 membrane with a degree of grafting of 21.2% for a 90-wt% ethanol feed concentration. Compared to the pervaporation process, the evapomeation process has a significantly increased separation factor with a decreased permeation rate for the same PVA-g-Nylon 4 membrane.