Etienne C. H. J. Michielsen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Etienne C. H. J. Michielsen has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
Will K.W.H. Wodzig
University Hospital Maastricht
4 shared publicationsJart H.C. Diris
2 shared publicationsJart Hc Diris
Department of Clinical Chemistry, University Hospital Maastricht, Maastricht, The Netherlands
2 shared publicationsMarja P Van Dieijen-Visser
2 shared publicationsMarja P. Van Dieijen-Visser
University Hospital Maastricht
2 shared publications- Marja P. van Dieijen-Visser
Department of Clinical Chemistry
2 shared publications
Latest Publications
- 11 February 2011
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 49 (5) , 923-925
False positive troponin result caused by a true macrotroponin
Background: A 35-year-old female presented with complaints of tiredness, shortness of breath and recent onset of chest pain. The cardiac troponin I (cTnI) concentration was elevated at 6.4 μg/L (Abbott Architect reference value: Methods: Use of different troponin assays, dilutions with assay diluent, addition of mouse serum, polyethylene glycol (PEG) precipitation and gel filtration chromatography (GFC) were used to investigate possible interference. Results: Troponin concentrations were below the level of detection when measured using all other troponin immunoassays. Serial dilutions of sample and addition of mouse serum did not alter the results. However, PEG precipitation and GFC showed the presence of a high molecular weight immunoreactive protein. Using GFC and protein-A IgG precipitation, the interference could be identified as a macrocomplex containing IgG and (fragments of) cTnI. Conclusions: We report a false positive cTnI result caused by a true macrotroponin, containing IgG and (fragments of) cTnI. This macrotroponin was only immunoreactive in the Abbott Architect cTnI immunoassay. Clinicians should be aware of analytical interference when troponin results are constantly elevated in the absence of (non)coronary causes of an increased troponin.
- 11 February 2011
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 49 (5) , 923-925
False positive troponin result caused by a true macrotroponin
Background: A 35-year-old female presented with complaints of tiredness, shortness of breath and recent onset of chest pain. The cardiac troponin I (cTnI) concentration was elevated at 6.4 μg/L (Abbott Architect reference value: Methods: Use of different troponin assays, dilutions with assay diluent, addition of mouse serum, polyethylene glycol (PEG) precipitation and gel filtration chromatography (GFC) were used to investigate possible interference. Results: Troponin concentrations were below the level of detection when measured using all other troponin immunoassays. Serial dilutions of sample and addition of mouse serum did not alter the results. However, PEG precipitation and GFC showed the presence of a high molecular weight immunoreactive protein. Using GFC and protein-A IgG precipitation, the interference could be identified as a macrocomplex containing IgG and (fragments of) cTnI. Conclusions: We report a false positive cTnI result caused by a true macrotroponin, containing IgG and (fragments of) cTnI. This macrotroponin was only immunoreactive in the Abbott Architect cTnI immunoassay. Clinicians should be aware of analytical interference when troponin results are constantly elevated in the absence of (non)coronary causes of an increased troponin.
- 1 January 2009
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 55 (1) , 101-108
Reference Population and Marathon Runner Sera Assessed by Highly Sensitive Cardiac Troponin T and Commercial Cardiac Troponin T and I Assays
Background: Endurance exercise can increase cardiac troponin (cTn) concentrations as high as those seen in cases of minor myocardial infarction. The inability of most cTn assays to reliably quantify cTn at very low concentrations complicates a thorough data analysis, and the clinical implications of such increases remain unclear. The application of recently developed highly sensitive cTn immunoassays may help resolve these problems. Methods: We evaluated the precommercial highly sensitive cardiac troponin T (hs-cTnT) assay from Roche Diagnostics and the Architect cardiac troponin I (cTnI-Architect) assay from Abbott Diagnostics by testing samples from a reference population of 546 individuals and a cohort of 85 marathon runners. We also measured the samples with the current commercial cTnT assay for comparison. Results: Although the hs-cTnT and cTnI-Architect assays were capable of measuring cTn concentrations at low concentrations (<0.01 μg/L), only the hs-cTnT assay demonstrated a CV of <10% at the 99th percentile of the reference population and a near-gaussian distribution of the measurements. After a marathon, 86% of the runners had cTnT concentrations greater than the 99th percentile with the hs-cTnT assay, whereas only 45% of the runners showed increased concentrations with the current cTnT assay. cTn concentrations remained significantly increased the day after the marathon. A multiple regression analysis demonstrated marathon experience and age to be significant predictors of postmarathon cTn concentrations (P < 0.05). Conclusions: The hs-cTnT assay was the only assay tested with a performance capability sufficient to detect cTn concentrations in healthy individuals. The number of runners with increased cTn concentrations after a marathon depends highly on an assay’s limit of detection (LOD). The assay with the lowest LOD, the hs-cTnT assay, showed that almost all runners had increased cTn concentrations. The clinical implications of these findings require further investigation.
- 1 January 2009
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 55 (1) , 101-108
Reference Population and Marathon Runner Sera Assessed by Highly Sensitive Cardiac Troponin T and Commercial Cardiac Troponin T and I Assays
Background: Endurance exercise can increase cardiac troponin (cTn) concentrations as high as those seen in cases of minor myocardial infarction. The inability of most cTn assays to reliably quantify cTn at very low concentrations complicates a thorough data analysis, and the clinical implications of such increases remain unclear. The application of recently developed highly sensitive cTn immunoassays may help resolve these problems. Methods: We evaluated the precommercial highly sensitive cardiac troponin T (hs-cTnT) assay from Roche Diagnostics and the Architect cardiac troponin I (cTnI-Architect) assay from Abbott Diagnostics by testing samples from a reference population of 546 individuals and a cohort of 85 marathon runners. We also measured the samples with the current commercial cTnT assay for comparison. Results: Although the hs-cTnT and cTnI-Architect assays were capable of measuring cTn concentrations at low concentrations (<0.01 μg/L), only the hs-cTnT assay demonstrated a CV of <10% at the 99th percentile of the reference population and a near-gaussian distribution of the measurements. After a marathon, 86% of the runners had cTnT concentrations greater than the 99th percentile with the hs-cTnT assay, whereas only 45% of the runners showed increased concentrations with the current cTnT assay. cTn concentrations remained significantly increased the day after the marathon. A multiple regression analysis demonstrated marathon experience and age to be significant predictors of postmarathon cTn concentrations (P < 0.05). Conclusions: The hs-cTnT assay was the only assay tested with a performance capability sufficient to detect cTn concentrations in healthy individuals. The number of runners with increased cTn concentrations after a marathon depends highly on an assay’s limit of detection (LOD). The assay with the lowest LOD, the hs-cTnT assay, showed that almost all runners had increased cTn concentrations. The clinical implications of these findings require further investigation.
- Open Access
- 1 December 2008
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 54 (12) , 2078-2079
Time-Dependent Instability of Cardiac Troponins in Human Plasma Spiked with NIST Reference Material 2921
- 1 December 2008
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 54 (12) , 2078-2079
Open AccessTime-Dependent Instability of Cardiac Troponins in Human Plasma Spiked with NIST Reference Material 2921
- 1 October 2008
- Published by Elsevier in Experimental and Molecular Pathology
- Vol. 85 (2) , 90-95
Release kinetics of intact and degraded troponin I and T after irreversible cell damage
- 1 October 2008
- Published by Elsevier in Experimental and Molecular Pathology
- Vol. 85 (2) , 90-95
Release kinetics of intact and degraded troponin I and T after irreversible cell damage
- Open Access
- 1 July 2008
- Published by SAGE Publications in Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
- Vol. 45 (4) , 389-394
The diagnostic value of serum and urinary NT-proBNP for heart failure
Background: Serum B-type natriuretic peptide (BNP) and the amino-terminal cleavage product of the prohormone (NT-proBNP) have been shown to be valuable parameters for the diagnosis of heart failure (HF) in the general population. Urinary BNP and NT-proBNP have also been suggested for diagnosis of HF. The present study investigated the diagnostic value of both serum and urinary NT-proBNP in selected groups of controls and patients diagnosed with HF. Methods: Creatinine clearance and serum and urinary NT-proBNP were measured in 76 controls and in 47 patients diagnosed with HF (NYHA III and IV). Echocardiography was used to exclude cardiac dysfunction in the control population by the combined normality of left ventricular ejection fraction (LVEF), E/A ratio (echocardiographic early [E] and late, or atrial [A] phases of ventricular filling), deceleration time and LV mass index. All patients diagnosed with HF had LVEF <40%. Results: NT-proBNP measurements in urine samples are subject to high variability. Receiver-operating characteristic area under the curve (AUC) for serum, urinary NT-proBNP and their products were 0.94, 0.72 and 0.93, respectively. Correction of urinary NT-proBNP for urinary creatinine content improved the AUC from 0.72 to 0.80. Negative predictive values for ruling out HF were 0.94, 0.67 and 0.89, respectively. Linear regression analysis revealed that creatinine clearance was more important in determining serum NT-proBNP concentrations than age. Conclusions: Serum NT-proBNP is the best parameter to rule out HF. The product of the serum and urinary concentrations has equal value. Urinary NT-proBNP alone performs rather poorly. Renal function influences NT-proBNP concentrations more than age in this selected population.
- 1 July 2008
- Published by SAGE Publications in Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
- Vol. 45 (4) , 389-394
Open AccessThe diagnostic value of serum and urinary NT-proBNP for heart failure
Background: Serum B-type natriuretic peptide (BNP) and the amino-terminal cleavage product of the prohormone (NT-proBNP) have been shown to be valuable parameters for the diagnosis of heart failure (HF) in the general population. Urinary BNP and NT-proBNP have also been suggested for diagnosis of HF. The present study investigated the diagnostic value of both serum and urinary NT-proBNP in selected groups of controls and patients diagnosed with HF. Methods: Creatinine clearance and serum and urinary NT-proBNP were measured in 76 controls and in 47 patients diagnosed with HF (NYHA III and IV). Echocardiography was used to exclude cardiac dysfunction in the control population by the combined normality of left ventricular ejection fraction (LVEF), E/A ratio (echocardiographic early [E] and late, or atrial [A] phases of ventricular filling), deceleration time and LV mass index. All patients diagnosed with HF had LVEF <40%. Results: NT-proBNP measurements in urine samples are subject to high variability. Receiver-operating characteristic area under the curve (AUC) for serum, urinary NT-proBNP and their products were 0.94, 0.72 and 0.93, respectively. Correction of urinary NT-proBNP for urinary creatinine content improved the AUC from 0.72 to 0.80. Negative predictive values for ruling out HF were 0.94, 0.67 and 0.89, respectively. Linear regression analysis revealed that creatinine clearance was more important in determining serum NT-proBNP concentrations than age. Conclusions: Serum NT-proBNP is the best parameter to rule out HF. The product of the serum and urinary concentrations has equal value. Urinary NT-proBNP alone performs rather poorly. Renal function influences NT-proBNP concentrations more than age in this selected population.
- 1 January 2008
- Published by Springer Nature in Sports Medicine
- Vol. 38 (5) , 425-435
Cardiac Troponin T Release after Prolonged Strenuous Exercise
Over the past 2 decades, there has been a large interest in cardiac troponin T (cTnT) elevations, which are often seen following endurance sport events. There have been many reports on this topic,...
- 1 January 2008
- Published by Springer Nature in Sports Medicine
- Vol. 38 (5) , 425-435
Cardiac Troponin T Release after Prolonged Strenuous Exercise
Over the past 2 decades, there has been a large interest in cardiac troponin T (cTnT) elevations, which are often seen following endurance sport events. There have been many reports on this topic,...
- 1 January 2008
- Published by Elsevier in Clinica Chimica Acta
- Vol. 387 (1-2) , 59-65
A specific immunoprecipitation method for isolating isoforms of insulin-like growth factor binding protein-3 from serum
- 1 January 2008
- Published by Elsevier in Clinica Chimica Acta
- Vol. 387 (1-2) , 59-65
A specific immunoprecipitation method for isolating isoforms of insulin-like growth factor binding protein-3 from serum
- 1 August 2007
- Published by Elsevier in Clinical Biochemistry
- Vol. 40 (12) , 851-855
Investigation of release and degradation of cardiac troponin T in patients with acute myocardial infarction
- 1 August 2007
- Published by Elsevier in Clinical Biochemistry
- Vol. 40 (12) , 851-855
Investigation of release and degradation of cardiac troponin T in patients with acute myocardial infarction
- Open Access
- 1 December 2006
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 52 (12) , 2306-2307
Size-Exclusion Chromatography of Circulating Cardiac Troponin T
- 1 December 2006
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 52 (12) , 2306-2307
Open AccessSize-Exclusion Chromatography of Circulating Cardiac Troponin T
- 1 January 2006
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 44 (12) , 1422-7
Interpretation of cardiac troponin T behaviour in size-exclusion chromatography
Clin Chem Lab Med 2006;44:1422–7.
- 1 January 2006
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 44 (12) , 1422-7
Interpretation of cardiac troponin T behaviour in size-exclusion chromatography
Clin Chem Lab Med 2006;44:1422–7.